IKCP0-GCF-WTSI-35-002 INTERCONNECTION WIRING DIAGRAM FOR WTS - ÷+S+÷-Ñ +
IKCP0-GCF-WTSI-35-002 INTERCONNECTION WIRING DIAGRAM FOR WTS - ÷+S+÷-Ñ +
IKCP0-GCF-WTSI-35-002 INTERCONNECTION WIRING DIAGRAM FOR WTS - ÷+S+÷-Ñ +
1 1 1 DRAWING INDEX 6
2 2 1 GENERAL NOTE 6
3 3~9 7 INVERTOR PANEL ---------- PLC PANEL 6
4 10 ~ 46 37 MCC PANEL ---------- PLC PANEL 6
5 47 ~ 50 4 PKG. PANEL ---------- PLC PANEL 6
6 51 ~ 72 22 FIELD ---------- PLC PANEL 6
7 73 ~ 99 27 SOL. PANEL ---------- PLC PANEL 6
8 100~102 3 PLC PANEL ---------- DCS PANEL 6
9 103 1 FIELD ---------- FIELD 6
10 104 1 CONTROL ROOM ---------- PLC PANEL 6
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
107 7 7 50
2. CABLE NUMBERING SYSTEM IS: Individual/Overall Shield for Pair or Triad Cable
2.1 KKS of feeding Switchgear/ Distribution or Instruments and control Signals. Voltage Level: 6.6kV(For MV), 0,6/1kV (For Others)
As per SLD or KKS code with the signal functions identifying the instrumentation and control signals 4. IDENTIFICATION OF MULTI-CORE & MULTIPAIR CABLES
Multi Core : Number(1 to 30) coded on individual core(Black) with words
2.2 Cubicle No. Multi Pair : Number(1 to 50 each) coded on individual cores(Black, Red) of each pair
Multi Triad : Number(1 to 15 each) coded on individual cores(Black, Red, Blue) of each triad
Cubicle No. of switchgear (if available) Multi-quad : Number(1 to 15 each) coded on individual cores(Black, Red, Bluem Orange) of each quad
5. EQUIPMENT ABBREVIATION
2.3 Service Level Code SWGR : SWITCHGEAR
X : Instrumentation and Analog, Communication cables, Computer input cables 6. JUMPER CABLE
EXTERNAL
2.4 Serial No. TERMINAL
TERM BLOCK
The serial number shall be used 0000 to 9999. NO. NO.
Note: Serial No. will start again for the follow cubicle. 1,3 TB2
: TERMINAL 1,3 AND 5 WILL BE JUMPERED
5
MV INV. PANEL #1 9 B1 B1 04
HIGH TDS SWRO HIGH PRESSURE PUMP - A PLC PANEL
-X13 10 W1 W1 05 TB80
(00GCK41AP001 FEEDBACK) 00GCK41GH001-X0001 00GCY00GH001
00GCK41GH001 SHIELD 06
0.6/1kV CU/PVC/PVC/IS 3px1.5
MV INV. PANEL #1 1 B2 B2 01
HIGH TDS SWRO HIGH PRESSURE PUMP - A PLC PANEL
-X13 2 W2 W2 02 TB99
(00GCK41AP001 CONTROL) 00GCY00GH001
00GCK41GH001 SHIELD 03
1p SP 1p SP
O'SHIELD SG
COM -X12 21 W1 W1 21
[NOTE]
END
FIELD
CONTINUED
MV INV. PANEL #2 9 B1 B1 01
HIGH TDS SWRO HIGH PRESSURE PUMP - B PLC PANEL
-X13 10 W1 W1 02 TB82
(00GCK42AP001 FEEDBACK) 00GCK42GH001-X0001 00GCY00GH001
00GCK42GH001 SHIELD 03
0.6/1kV CU/PVC/PVC/IS 3px1.5
MV INV. PANEL #2 1 B2 B2 04
HIGH TDS SWRO HIGH PRESSURE PUMP - B PLC PANEL
-X13 2 W2 W2 05 TB99
(00GCK42AP001 CONTROL) 00GCY00GH001
00GCK42GH001 SHIELD 06
1p SP 1p SP
O'SHIELD SG
COM -X12 21 W1 W1 31
TB09
MV INV. PANEL #2 REM 14 W2 W2 32
HIGH TDS SWRO STOPPED 15 W3 00GCK42GH001-C0003 W3 02
HIGH PRESSURE -X14
PUMP - B RUNNING 13 W4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 W4 04 PLC PANEL
TB10
(00GCK42AP001 FAULT 16 W5 W5 06 00GCY00GH001
REM/STOP/RUN/FAUL
T STATUS) EMER STOPPED -X12 22 W6 W6 08
00GCK42GH001 1C SP 1C SP
[NOTE]
END
FIELD
CONTINUED
O'SHIELD SG
COM 5 W1 W1 05
LOW TDS INV, PANEL REM 6 W2 W2 06
#1 00GCK31GH001-C0003
LOW TDS SWRO STOPPED DTB01 10 W3 W3 08 TB09
0.6/1kV CU/PVC/PVC/OS 7Cx1.5
HIGH PRESSURE RUNNING 8 W4 W4 10 PLC PANEL
PUMP - A
(00GCK31AP001 FAULT 12 W5 W5 12 00GCY00GH001
REM/STOP/RUN/FAUL 2C SP 2C SP
T STATUS)
00GCK31GH001
COM 1 W1 W1 06
#1 00GCK31GH001-C0004
LOW TDS SWRO RUN DTB01 2 W2 W2 05 TB66
HIGH PRESSURE 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 PLC PANEL
STOP 4 W3 W3 08
PUMP - A 00GCY00GH001
(00GCK31AP001 2C SP 2C SP
RUN/STOP COMMAND)
00GCK31GH001
SHIELD SG
[NOTE]
END
FIELD
CONTINUED
O'SHIELD SG
COM 5 W1 W1 17
LOW TDS INV, PANEL REM 6 W2 W2 18
#2 00GCK32GH001-C0003
LOW TDS SWRO STOPPED DTB01 10 W3 W3 20 TB10
0.6/1kV CU/PVC/PVC/OS 7Cx1.5
HIGH PRESSURE RUNNING 8 W4 W4 22 PLC PANEL
PUMP - B
(00GCK32AP001 FAULT 12 W5 W5 24 00GCY00GH001
REM/STOP/RUN/FAUL 2C SP 2C SP
T STATUS)
00GCK32GH001
COM 1 W1 W1 10
#2 00GCK32GH001-C0004
LOW TDS SWRO RUN DTB01 2 W2 W2 09 TB67
HIGH PRESSURE 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 PLC PANEL
STOP 4 W3 W3 12
PUMP - B 00GCY00GH001
(00GCK32AP001 2C SP 2C SP
RUN/STOP COMMAND)
00GCK32GH001
SHIELD SG
[NOTE]
END
FIELD
CONTINUED
04 B1 B1 01
INV, PANEL #1
PLC PANEL
DRIVEN UNIT FOR CLARIFIER WT - A (00GBD10AM001 FEEDBACK) 05 W1 W1 02 TB79
00GDB21GH001
00GCY00GH001
SHIELD 03
TB03
01 B2 B2 01
INV, PANEL #1
PLC PANEL
DRIVEN UNIT FOR CLARIFIER WT - A (00GBD10AM001 CONTROL) 02 W2 W2 02 TB98
00GDB21GH001 00GDB21GH001-X0004 00GCY00GH001
SHIELD 03
0.6/1kV CU/PVC/PVC/IS 6px1.5
04 B3 B3 07
INV, PANEL #1
PLC PANEL
DRIVEN UNIT FOR CLARIFIER WT - C (00GBD12AM001FEEDBACK) 05 W3 W3 08 TB79
00GDB21GH001
00GCY00GH001
SHIELD 09
TB09
01 B4 B4 07
INV, PANEL #1
PLC PANEL
DRIVEN UNIT FOR CLARIFIER WT - C (00GBD12AM001 CONTROL) 02 W4 W4 08 TB98
00GDB21GH001
00GCY00GH001
SHIELD 09
2p SP 2p SP
O'SHIELD SG
04 B1 B1 04
INV, PANEL #1
PLC PANEL
DRIVEN UNIT FOR CLARIFIER WT -B (00GBD11AM001 FEEDBACK) 05 W1 W1 05 TB79
00GDB21GH001
00GCY00GH001
SHIELD 06
TB06
01 B2 B2 04
INV, PANEL #1
PLC PANEL
DRIVEN UNIT FOR CLARIFIER WT - B (00GBD11AM001 CONTROL) 02 W2 W2 05 TB98
00GDB21GH001 00GDB21GH001-X0005 00GCY00GH001
SHIELD 06
0.6/1kV CU/PVC/PVC/IS 6px1.5
04 B3 B3 10
INV, PANEL #1
PLC PANEL
01 B4 B4 10
INV, PANEL #1
PLC PANEL
DRIVEN UNIT FOR CLARIFIER WT - D (00GBD13AM001 CONTROL) 02 W4 W4 11 TB98
00GDB21GH001
00GCY00GH001
SHIELD 12
2p SP 2p SP
O'SHIELD SG
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
INV, PANEL #2 04 B1 B1 19
REGENERATION PUMP - A
05 W1 W1 20 TB79
(00GCP21AP001 FEEDBACK) 00GCP21GH001-X0001
00GCP21GH001 SHIELD 21
TB03
INV, PANEL #2 01 B2 0.6/1kV CU/PVC/PVC/IS 3px1.5 B2 07
REGENERATION PUMP - A
02 W2 W2 08 TB99
(00GCP21AP001 CONTROL) 1p SP
00GCP21GH001 SHIELD 09
1p SP
O'SHIELD SG
INV, PANEL #2 04 B1 B1 22
REGENERATION PUMP - B
05 W1 W1 23 TB79
(00GCP22AP001 FEEDBACK) 00GCP21GH001-X0002 PLC PANEL
00GCP21GH001 SHIELD 24
TB06 00GCY00GH001
INV, PANEL #2 01 B2 0.6/1kV CU/PVC/PVC/IS 3px1.5 B2 10
REGENERATION PUMP - B
02 W2 W2 11 TB99
(00GCP22AP001 CONTROL) 1p SP
00GCP21GH001 SHIELD 12
1p SP
O'SHIELD SG
SHIELD SG
INV, PANEL #2
COM 07 W1 00GCP21GH001-C0006 W1 10
REGENERATION PUMP - A
(00GCP21AP001 RUN TB01 08 W2 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W2 09 TB68
RUN/STOP COMMAND)
00GCP21GH001
STOP 06 W3 W3 12
2C SP
SHIELD SG PLC PANEL
INV, PANEL #2 00GCY00GH001
COM 07 W1 00GCP21GH001-C0008 W1 46
REGENERATION PUMP - B
(00GCP22AP001 RUN TB04 08 W2 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W2 45 TB69
RUN/STOP COMMAND)
00GCP21GH001
STOP 06 W3 W3 48
2C SP
SHIELD SG
[NOTE]
END
FIELD
CONTINUED
COM 55 W1 W1 01
52 W1 W1 49
FILTER BACKWASH RUN
51 W2 04BJD04FD-C0004 W2 50
PUMP - A TB65 PLC PANEL
(RUN/STOP 04BJD03FE 53 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 51
STOP 00GCY00GH001
COMMAND) -XM2 54 W4 W4 52
00GCK21AP001
MCC-04BJD04FD 1C SP 1C SP
SHIELD SG
COM 65 W1 W1 09
SHIELD SG
62 W1 W1 45
FILTER BACKWASH RUN
61 W2 04BJD04FE-C0004 W2 46
PUMP - B TB64 PLC PANEL
(RUN/STOP 04BJD03FE 63 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 47
STOP 00GCY00GH001
COMMAND) -XM2 64 W4 W4 48
00GCK22AP001
MCC-04BJD04FE 1C SP 1C SP
SHIELD SG
COM 5 W1 W1 17
SWRO FEEDWATER REM 9 W2 W2 18
PUMP - A 04BJD05FD 04BJD05FB-C0003
(REM/STOP/RUN/FAUL STOPPED 7 W3 W3 20 TB07 PLC PANEL
-XM3 0.6/1kV CU/PVC/PVC/OS 7Cx1.5
T STATUS) RUNNING 6 W4 W4 22 00GCY00GH001
00GCK11AP001
MCC-04BJD05FB NO FAULT 8 W5 W5 24
2C SP 2C SP
2 W1 W1 41
SWRO FEEDWATER RUN
1 W2 04BJD05FB-C0004 W2 42
PUMP - A TB65 PLC PANEL
(RUN/STOP 04BJD05FD 3 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 43
STOP 00GCY00GH001
COMMAND) -XM3 4 W4 W4 44
00GCK11AP001
MCC-04BJD05FB 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 15 W1 W1 25
12 W1 W1 41
SWRO FEEDWATER RUN
11 W2 04BJD05FC-C0004 W2 42
PUMP - B TB64 PLC PANEL
(RUN/STOP 04BJD05FD 13 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 43
STOP 00GCY00GH001
COMMAND) -XM3 14 W4 W4 44
00GCK12AP001
MCC-04BJD05FC 1C SP 1C SP
SHIELD SG
COM 11 W1 W1 25
SHIELD SG
SLUDGE TRANSFER 8 W1 W1 25
RUN
PUMP - A 7 W2 04BJD02FA-C0004 W2 26
(RUN/STOP TB64 PLC PANEL
04BJD01FB 9 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 27
COMMAND) STOP 00GCY00GH001
00GBS11AP001 -XM1 10 W4 W4 28
MCC-04BJD02FA 1C SP 1C SP
SHIELD SG
COM 21 W1 W1 25
18 W1 W1 29
SLUDGE TRANSFER RUN
17 W2 04BJD02FB-C0004 W2 30
PUMP - B TB64 PLC PANEL
(RUN/STOP 04BJD01FB 19 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 31
STOP 00GCY00GH001
COMMAND) -XM1 20 W4 W4 32
00GBS12AP001
MCC-04BJD02FB 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 31 W1 W1 01
28 W1 W1 33
SLUDGE TRANSFER RUN
27 W2 04BJD02FC-C0004 W2 34
PUMP - C TB64 PLC PANEL
(RUN/STOP 04BJD01FB 29 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 35
STOP 00GCY00GH001
COMMAND) -XM1 30 W4 W4 36
00GBS13AP001
MCC-04BJD02FC 1C SP 1C SP
SHIELD SG
COM 5 W1 W1 09
SHIELD SG
2 W1 W1 29
SLUDGE TRANSFER RUN
1 W2 04BJD03FB-C0004 W2 30
PUMP - D TB65 PLC PANEL
(RUN/STOP 04BJD03FE 3 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 31
STOP 00GCY00GH001
COMMAND) -XM2 4 W4 W4 32
00GBS14AP001
MCC-04BJD03FB 1C SP 1C SP
SHIELD SG
COM 15 W1 W1 17
12 W1 W1 45
SLUDGE TRANSFER RUN
11 W2 04BJD03FC-C0004 W2 46
PUMP - E TB65 PLC PANEL
(RUN/STOP 04BJD03FE 13 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 47
STOP 00GCY00GH001
COMMAND) -XM2 14 W4 W4 48
00GBS15AP001
MCC-04BJD03FC 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 25 W1 W1 25
22 W1 W1 53
SLUDGE TRANSFER RUN
21 W2 04BJD03FD-C0004 W2 54
PUMP - F TB65 PLC PANEL
(RUN/STOP 04BJD03FE 23 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 55
STOP 00GCY00GH001
COMMAND) -XM2 24 W4 W4 56
00GBS16AP001
MCC-04BJD03FD 1C SP 1C SP
SHIELD SG
COM 41 W1 W1 09
BWRO FEEDWATER REM 45 W2 W2 10
PUMP - A 04BJD01FB 04BJD01RA-C0003
(REM/STOP/RUN/FAUL STOPPED 43 W3 W3 12 TB10 PLC PANEL
-XM1 0.6/1kV CU/PVC/PVC/OS 7Cx1.5
T STATUS) RUNNING 42 W4 W4 14 00GCY00GH001
00GCK61AP001
SHIELD SG
38 W1 W1 21
BWRO FEEDWATER RUN
37 W2 04BJD01RA-C0004 W2 22
PUMP - A TB66 PLC PANEL
(RUN/STOP 04BJD01FB 39 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 23
STOP 00GCY00GH001
COMMAND) -XM1 40 W4 W4 24
00GCK61AP001
MCC-04BJD01RA 1C SP 1C SP
SHIELD SG
COM 51 W1 W1 13
BWRO FEEDWATER REM 55 W2 W2 14
PUMP - B 04BJD01FB 04BJD01RB-C0003
(REM/STOP/RUN/FAUL STOPPED 53 W3 W3 16 TB09 PLC PANEL
-XM1 0.6/1kV CU/PVC/PVC/OS 7Cx1.5
T STATUS) RUNNING 52 W4 W4 18 00GCY00GH001
00GCK62AP001
MCC-04BJD01RB NO FAULT 54 W5 W5 20
2C SP 2C SP SG
SHIELD
48 W1 W1 25
BWRO FEEDWATER RUN
47 W2 04BJD01RB-C0004 W2 26
PUMP - B TB67 PLC PANEL
(RUN/STOP 04BJD01FB 49 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 27
STOP 00GCY00GH001
COMMAND) -XM1 50 W4 W4 28
00GCK62AP001
MCC-04BJD01RB 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 115 W1 W1 25
112 W1 W1 45
MBP FEEDWATER RUN
111 W2 04BJD04RF-C0004 W2 46
PUMP - A TB66 PLC PANEL
(RUN/STOP 04BJD03FE 113 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 47
STOP 00GCY00GH001
COMMAND) -XM2 114 W4 W4 48
00GCK81AP001
MCC-04BJD04RF 1C SP 1C SP
SHIELD SG
COM 125 W1 W1 01
SHIELD SG
122 W1 W1 49
MBP FEEDWATER RUN
121 W2 04BJD04RG-C0004 W2 50
PUMP - B TB66 PLC PANEL
(RUN/STOP 04BJD03FE 123 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 51
STOP 00GCY00GH001
COMMAND) -XM2 124 W4 W4 52
00GCK82AP001
MCC-04BJD04RG 1C SP 1C SP
SPARE
SHIELD SG
COM 45 W1 W1 09
42 W1 W1 05
RUN
CIP PUMP - A 41 W2 04BJD06FD-C0004 W2 06
TB67 PLC PANEL
(RUN/STOP 43 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 07
04BJD05FD
COMMAND) STOP 00GCY00GH001
-XM3 44 W4 W4 08
00GCB11AP001
MCC-04BJD06FD 1C SP 1C SP
SPARE
SHIELD SG
END
MCC ROOM
CONTINUED
COM 55 W1 W1 17
REM 59 W2 W2 18
CIP PUMP - B 04BJD05FD 04BJD06FE-C0003
STOPPED 57 W3 W3 20 TB14
(REM/STOP/RUN/FAUL XM3 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
T STATUS) RUNNING 56 W4 W4 22
00GCB12AP001
00GCY00GH001
NO FAULT 58 W5 W5 24
MCC-04BJD06FE
2C SP 2C SP
SHIELD SG
52 W1 W1 09
RUN
CIP PUMP - B 51 W2 04BJD06FE-C0004 W2 10
(RUN/STOP PLC PANEL
04BJD05FD 53 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 11 TB66
COMMAND) STOP 00GCY00GH001
-XM3 54 W4 W4 12
00GCB12AP001
MCC-04BJD06FE 1C SP 1C SP
SHIELD SG
COM 65 W1 W1 09
ELECTRIC HEATER REM 69 W2 W2 10
FOR HOT WATER 04BJD07FF 04BJD08FD-C0003
STOPPED 67 W3 W3 12 TB16
TANK XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 66 W4 W4 14
00GCY00GH001
SHIELD SG
62 W1 W1 53
RUN
ELECTRIC HEATER 61 W2 04BJD08FD-C0004 W2 54
TB67 PLC PANEL
FOR HOT WATER 63 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 55
04BJD07FF 00GCY00GH001
TANK (RUN/STOP CMD) STOP
-XM4 64 W4 W4 56
00GCP30AH001
MCC-04BJD08FD 1C SP 1C SP
SHIELD SG
COM 5 W1 W1 17
CAUSTIC DOSING REM 9 W2 W2 18
PUMP -A FOR 04BJD07FF 04BJD07FB-C0003
STOPPED 7 W3 W3 20 TB05
CLARIFIER FOR WT XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 6 W4 W4 22
T STATUS)
00GCY00GH001
NO FAULT 8 W5 W5 24
00GBN31AP001
MCC-04BJD07FB 2C SP 2C SP
SHIELD SG
2 W1 W1 09
CAUSTIC DOSING RUN
PUMP -A FOR 1 W2 04BJD07FB-C0004 W2 10
TB65 PLC PANEL
CLARIFIER FOR WT 3 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 11
04BJD07FF
(RUN/STOP STOP 00GCY00GH001
-XM4 4 W4 W4 12
COMMAND)
00GBN31AP001 1C SP 1C SP
MCC-04BJD07FB
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 15 W1 W1 25
CAUSTIC DOSING REM 19 W2 W2 26
PUMP -B FOR 04BJD07FF 04BJD07FC-C0003
STOPPED 17 W3 W3 28 TB06
CLARIFIER FOR WT XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 16 W4 W4 30
T STATUS)
00GCY00GH001
NO FAULT 18 W5 W5 32
00GBN32AP001
MCC-04BJD07FC 2C SP 2C SP
SHIELD SG
12 W1 W1 13
CAUSTIC DOSING RUN
PUMP -B FOR 11 W2 04BJD07FC-C0004 W2 14
TB64 PLC PANEL
CLARIFIER FOR WT 13 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 15
04BJD07FF 00GCY00GH001
(RUN/STOP STOP
-XM4 14 W4 W4 16
COMMAND)
00GBN32AP001 1C SP 1C SP
MCC-04BJD07FC
SHIELD SG
COM 25 W1 W1 09
SHIELD SG
22 W1 W1 53
AIR BLOWER -A FOR RUN
21 W2 04BJD06FB-C0004 W2 54
NEUTRALIZATION TB66 PLC PANEL
(RUN/STOP 04BJD05FD 23 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 55
STOP 00GCY00GH001
COMMAND) -XM3 24 W4 W4 56
00GCC11AN001
MCC-04BJD06FB 1C SP 1C SP
SHIELD SG
COM 35 W1 W1 17
32 W1 W1 61
AIR BLOWER -B FOR RUN
31 W2 04BJD06FC-C0004 W2 62
NEUTRALIZATION TB67 PLC PANEL
(RUN/STOP 04BJD05FD 33 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 63
STOP 00GCY00GH001
COMMAND) -XM3 34 W4 W4 64
00GCC12AN001
MCC-04BJD06FC 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 35 W1 W1 25
32 W1 W1 61
NEUTRALIZATION PIT RUN
31 W2 04BJD04FB-C0004 W2 62
PUMP - A TB66 PLC PANEL
(RUN/STOP 04BJD03FE 33 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 63
STOP 00GCY00GH001
COMMAND) -XM2 34 W4 W4 64
00GCR11AP001
MCC-04BJD04FB 1C SP 1C SP
SHIELD SG
COM 45 W1 W1 01
SHIELD SG
42 W1 W1 01
NEUTRALIZATION PIT RUN
41 W2 04BJD04FC-C0004 W2 02
PUMP - B TB67 PLC PANEL
(RUN/STOP 04BJD03FE 43 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 03
STOP 00GCY00GH001
COMMAND) -XM2 44 W4 W4 04
00GCR12AP001
MCC-04BJD04FC 1C SP 1C SP
SHIELD SG
COM 75 W1 W1 09
72 W1 W1 21
ELECTRIC HEATER RUN
71 W2 04BJD08FE-C0004 W2 22
FOR CIP TANK TB67 PLC PANEL
(RUN/STOP 04BJD07FF 73 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 23
STOP 00GCY00GH001
COMMAND) -XM4 74 W4 W4 24
00GCB10AH001
MCC-04BJD08FE 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 25 W1 W1 17
SULFURIC ACID REM 29 W2 W2 18
DOSING PUMP - A FOR 04BJD07FF 04BJD07FD-C0003
STOPPED 27 W3 W3 20 TB18
BWRO XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 26 W4 W4 22
T STATUS)
00GCY00GH001
NO FAULT 28 W5 W5 24
00GCN53AP001
MCC-04BJD07FD 2C SP 2C SP
SHIELD SG
22 W1 W1 25
SULFURIC ACID RUN
DOSING PUMP - A FOR 21 W2 04BJD07FD-C0004 W2 26
TB68 PLC PANEL
BWRO 23 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 27
04BJD07FF
(RUN/STOP STOP 00GCY00GH001
-XM4 24 W4 W4 28
COMMAND)
00GCN53AP001 1C SP 1C SP
MCC-04BJD07FD
SHIELD SG
COM 35 W1 W1 25
SULFURIC ACID REM 39 W2 W2 26
DOSING PUMP - B FOR 04BJD07FF 04BJD07FE-C0003
STOPPED 37 W3 W3 28 TB17
BWRO XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 36 W4 W4 30
00GCY00GH001
SHIELD SG
32 W1 W1 53
SULFURIC ACID RUN
DOSING PUMP - B FOR 31 W2 04BJD07FE-C0004 W2 54
TB69 PLC PANEL
BWRO 33 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 55
04BJD07FF 00GCY00GH001
(RUN/STOP STOP
-XM4 34 W4 W4 56
COMMAND)
00GCN54AP001 1C SP 1C SP
MCC-04BJD07FE
SHIELD SG
COM 95 W1 W1 01
92 W1 W1 33
AGITATOR FOR SBS RUN
91 W2 04BJD07RB-C0004 W2 34
DOSING TANK TB68 PLC PANEL
(RUN/STOP 04BJD07FF 93 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 35
STOP 00GCY00GH001
COMMAND) -XM4 94 W4 W4 36
00GCN61AM001
MCC-04BJD07RB 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 71 W1 W1 01
68 W1 W1 49
ANTISCALANT DOSING RUN
67 W2 04BJD01RD-C0004 W2 50
PUMP - A FOR SWRO TB68 PLC PANEL
(RUN/STOP 04BJD01FB 69 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 51
STOP 00GCY00GH001
COMMAND) -XM1 70 W4 W4 52
00GCN72AP001
MCC-04BJD01RD 1C SP 1C SP
SHIELD SG
COM 81 W1 W1 09
SHIELD SG
78 W1 W1 53
ANTISCALANT DOSING RUN
77 W2 04BJD01RE-C0004 W2 54
PUMP - B FOR SWRO TB68 PLC PANEL
(RUN/STOP 04BJD01FB 79 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 55
STOP 00GCY00GH001
COMMAND) -XM1 80 W4 W4 56
00GCN73AP001
MCC-04BJD01RE 1C SP 1C SP
SHIELD SG
COM 91 W1 W1 17
88 W1 W1 57
ANTISCALANT DOSING RUN
87 W2 04BJD01RF-C0004 W2 58
PUMP - A FOR BWRO TB68 PLC PANEL
(RUN/STOP 04BJD01FB 89 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 59
STOP 00GCY00GH001
COMMAND) -XM1 90 W4 W4 60
00GCN74AP001
MCC-04BJD01RF 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 101 W1 W1 25
98 W1 W1 61
ANTISCALANT DOSING RUN
97 W2 04BJD01RG-C0004 W2 62
PUMP - B FOR BWRO TB68 PLC PANEL
(RUN/STOP 04BJD01FB 99 W3 W3 63
STOP 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
COMMAND) -XM1 100 W4 W4 64
00GCN75AP001
MCC-04BJD01RG 1C SP 1C SP
SHIELD SG
COM 75 W1 W1 25
NaOCl DOSING PUMP- REM 79 W2 W2 26
A FOR CLARIFIER FOR 04BJD03FE 04BJD03RA-C0003
STOPPED 77 W3 W3 28 TB05
WT -XM2 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 76 W4 W4 30
00GCY00GH001
SHIELD SG
72 W1 W1 37
NaOCl DOSING PUMP- RUN
A FOR CLARIFIER FOR 71 W2 04BJD03RA-C0004 W2 38
TB64 PLC PANEL
WT 73 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 39
04BJD03FE 00GCY00GH001
(RUN/STOP STOP
-XM2 74 W4 W4 40
COMMAND)
00GBN51AP001 1C SP 1C SP
MCC-04BJD03RA
SHIELD SG
COM 85 W1 W1 01
NaOCl DOSING PUMP- REM 89 W2 W2 02
B FOR CLARIFIER FOR 04BJD03FE 04BJD03RB-C0003
STOPPED 87 W3 W3 04 TB07
WT -XM2 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 86 W4 W4 06
T STATUS)
00GCY00GH001
NO FAULT 88 W5 W5 08
00GBN52AP001
MCC-04BJD03RB 2C SP 2C SP
SHIELD SG
82 W1 W1 33
NaOCl DOSING PUMP- RUN
B FOR CLARIFIER FOR 81 W2 04BJD03RB-C0004 W2 34
TB65 PLC PANEL
WT 83 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 35
04BJD03FE
(RUN/STOP STOP 00GCY00GH001
-XM2 84 W4 W4 36
COMMAND)
00GBN52AP001 1C SP 1C SP
MCC-04BJD03RB
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 45 W1 W1 17
REM 49 W2 W2 18
SUMP PUMP - A 04BJD07FF 04BJD08FB-C0003
STOPPED 47 W3 W3 20 TB08
(REM/STOP/RUN/FAUL XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
T STATUS) RUNNING 46 W4 W4 22
00GMG11AP001
00GCY00GH001
NO FAULT 48 W5 W5 24
MCC-04BJD08FB
2C SP 2C SP
SHIELD SG
42 W1 W1 57
RUN
SUMP PUMP - A 41 W2 04BJD08FB-C0004 W2 58
TB65 PLC PANEL
(RUN/STOP 43 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 59
04BJD07FF
COMMAND) STOP 00GCY00GH001
-XM4 44 W4 W4 60
00GMG11AP001
MCC-04BJD08FB 1C SP 1C SP
SHIELD SG
COM 55 W1 W1 25
REM 59 W2 W2 26
SUMP PUMP - B 04BJD07FF 04BJD08FC-C0003
STOPPED 57 W3 W3 28 TB07
(REM/STOP/RUN/FAUL XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
T STATUS) RUNNING 56 W4 W4 30
00GCY00GH001
SHIELD SG
52 W1 W1 53
RUN
SUMP PUMP - B 51 W2 04BJD08FC-C0004 W2 54
TB64 PLC PANEL
(RUN/STOP 53 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 55
04BJD07FF 00GCY00GH001
COMMAND) STOP
-XM4 54 W4 W4 56
00GMG12AP001
MCC-04BJD08FC 1C SP 1C SP
SHIELD SG
COM 95 W1 W1 17
92 W1 W1 41
POTABLE FEED RUN
91 W2 04BJD03RE-C0004 W2 42
WATER PUMP - A TB69 PLC PANEL
(RUN/STOP 04BJD03FE 93 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 43
STOP 00GCY00GH001
COMMAND) -XM2 94 W4 W4 44
00GKD11AP001
MCC-04BJD03RE 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 105 W1 W1 15
102 W1 W1 13
POTABLE FEED RUN
101 W2 04BJD03RF-C0004 W2 14
WATER PUMP - B TB68 PLC PANEL
(RUN/STOP 04BJD03FE 103 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 15
STOP 00GCY00GH001
COMMAND) -XM2 104 W4 W4 16
00GKD12AP001
MCC-04BJD03RF 1C SP 1C SP
SHIELD SG
COM 5 W1 W1 01
SHIELD SG
2 W1 W1 17
MULTIMEDIA FEED RUN
1 W2 04BJE03FB-C0004 W2 18
WATER PUMP - A TB64 PLC PANEL
(RUN/STOP 04BJE03FD 3 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 19
STOP 00GCY00GH001
COMMAND) -XM2 4 W4 W4 20
00GBK21AP001
MCC-04BJE03FB 1C SP 1C SP
SHIELD SG
COM 15 W1 W1 17
12 W1 W1 21
MULTIMEDIA FEED RUN
11 W2 04BJE03FC-C0004 W2 22
WATER PUMP - B TB65 PLC PANEL
(RUN/STOP 04BJE03FD 13 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 23
STOP 00GCY00GH001
COMMAND) -XM2 14 W4 W4 24
00GBK22AP001
MCC-04BJE03FC 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 55 W1 W1 09
52 W1 W1 37
BWRO HIGH RUN
51 W2 04BJE07RF-C0004 W2 38
PRESSURE PUMP - A TB66 PLC PANEL
(RUN/STOP 04BJE07FH 53 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 39
STOP 00GCY00GH001
COMMAND) -XM4 54 W4 W4 40
00GCK71AP001
MCC-04BJE07RF 1C SP 1C SP
SHIELD SG
COM 65 W1 W1 17
SHIELD SG
62 W1 W1 41
BWRO HIGH RUN
61 W2 04BJE07RG-C0004 W2 42
PRESSURE PUMP - B TB67 PLC PANEL
(RUN/STOP 04BJE07FH 63 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 43
STOP 00GCY00GH001
COMMAND) -XM4 64 W4 W4 44
00GCK72AP001
MCC-04BJE07RG 1C SP 1C SP
SHIELD SG
COM 5 W1 W1 17
SULFURIC ACID REM 9 W2 W2 18
DOSING PUMP - A FOR 04BJE07FH 04BJE07FF-C0003
STOPPED 7 W3 W3 20 TB03
CLARIFIER FOR WT -XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 6 W4 W4 22
T STATUS)
00GCY00GH001
NO FAULT 8 W5 W5 24
00GBN11AP001
MCC-04BJE07FF 2C SP 2C SP
SHIELD SG
2 W1 W1 57
SULFURIC ACID RUN
DOSING PUMP - A FOR 1 W2 04BJE07FF-C0004 W2 58
TB64 PLC PANEL
CLARIFIER FOR WT 3 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 59
04BJE07FH
(RUN/STOP STOP 00GCY00GH001
-XM4 4 W4 W4 60
COMMAND)
00GBN11AP001 1C SP 1C SP
MCC-04BJE07FF
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 15 W1 W1 25
SULFURIC ACID REM 19 W2 W2 26
DOSING PUMP - B FOR 04BJE07FH 04BJE07FG-C0003
STOPPED 17 W3 W3 28 TB03
CLARIFIER FOR WT -XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 16 W4 W4 30
T STATUS)
00GCY00GH001
NO FAULT 18 W5 W5 32
00GBN12AP001
MCC-04BJE07FG 2C SP 2C SP
SHIELD SG
12 W1 W1 61
SULFURIC ACID RUN
DOSING PUMP - B FOR 11 W2 04BJE07FG-C0004 W2 62
TB64 PLC PANEL
CLARIFIER FOR WT 13 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 63
04BJE07FH 00GCY00GH001
(RUN/STOP STOP
-XM4 14 W4 W4 64
COMMAND)
00GBN12AP001 1C SP 1C SP
MCC-04BJE07FG
SHIELD SG
COM 51 W1 W1 17
SULFURIC ACID REM 55 W2 W2 18
DOSING PUMP- A FOR 04BJE01FB 04BJE01RD-C0003
STOPPED 53 W3 W3 20 TB22
SWRO -XM1 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 52 W4 W4 22
00GCY00GH001
SHIELD SG
48 W1 W1 25
SULFURIC ACID RUN
DOSING PUMP- A FOR 47 W2 04BJE01RD-C0004 W2 26
TB69 PLC PANEL
SWRO 49 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 27
04BJE01FB 00GCY00GH001
(RUN/STOP STOP
-XM1 50 W4 W4 28
COMMAND)
00GCN15AP001 1C SP 1C SP
MCC-04BJE01RD
SHIELD SG
COM 61 W1 W1 25
SULFURIC ACID REM 65 W2 W2 26
DOSING PUMP- B FOR 04BJE01FB 04BJE01RE-C0003
STOPPED 63 W3 W3 28 TB22
SWRO -XM1 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 62 W4 W4 30
T STATUS)
00GCY00GH001
NO FAULT 64 W5 W5 32
00GCN16AP001
MCC-04BJE01RE 2C SP 2C SP
SHIELD SG
58 W1 W1 29
SULFURIC ACID RUN
DOSING PUMP- B FOR 57 W2 04BJE01RE-C0004 W2 30
TB69 PLC PANEL
SWRO 59 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 31
04BJE01FB
(RUN/STOP STOP 00GCY00GH001
-XM1 60 W4 W4 32
COMMAND)
00GCN16AP001 1C SP 1C SP
MCC-04BJE01RE
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 105 W1 W1 25
PUMP- A FOR MMF REM 109 W2 W2 26
BACKWASH & RO 04BJE05FF 04BJE05RD-C0003
STOPPED 107 W3 W3 28 TB10
BRINE -XM3 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 106 W4 W4 30
T STATUS)
00GCY00GH001
NO FAULT 108 W5 W5 32
00GMG21AP001
MCC-04BJE05RD 2C SP 2C SP
SHIELD SG
102 W1 W1 29
PUMP- A FOR MMF RUN
BACKWASH & RO 101 W2 04BJE05RD-C0004 W2 30
TB66 PLC PANEL
BRINE 103 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 31
04BJE05FF
(RUN/STOP STOP 00GCY00GH001
-XM3 104 W4 W4 32
COMMAND)
00GMG21AP001 1C SP 1C SP
MCC-04BJE05RD
SHIELD SG
COM 115 W1 W1 01
PUMP- B FOR MMF REM 119 W2 W2 02
BACKWASH & RO 04BJE05FF 04BJE05RE-C0003
STOPPED 117 W3 W3 04 TB11
BRINE -XM3 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 116 W4 W4 06
00GCY00GH001
SHIELD SG
112 W1 W1 33
PUMP- B FOR MMF RUN
BACKWASH & RO 111 W2 04BJE05RE-C0004 W2 34
TB66 PLC PANEL
BRINE 113 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 35
04BJE05FF 00GCY00GH001
(RUN/STOP STOP
-XM3 114 W4 W4 36
COMMAND)
00GMG22AP001 1C SP 1C SP
MCC-04BJE05RE
SHIELD SG
COM 35 W1 W1 25
REM 39 W2 W2 26
FLUSHING PUMP - A 04BJE07FH 04BJE08FC-C0003
STOPPED 37 W3 W3 28 TB13
(REM/STOP/RUN/FAUL -XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
T STATUS) RUNNING 36 W4 W4 30
00GCP11AP001
00GCY00GH001
NO FAULT 38 W5 W5 32
MCC-04BJE08FC
2C SP 2C SP
SHIELD SG
32 W1 W1 13
RUN
FLUSHING PUMP - A 31 W2 04BJE08FC-C0004 W2 14
TB67 PLC PANEL
(RUN/STOP 33 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 15
04BJE07FH
COMMAND) STOP 00GCY00GH001
-XM4 34 W4 W4 16
00GCP11AP001
MCC-04BJE08FC 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 45 W1 W1 01
REM 49 W2 W2 02
FLUSHING PUMP - B 04BJE07FH 04BJE08FD-C0003
STOPPED 47 W3 W3 04 TB14
(REM/STOP/RUN/FAUL -XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
T STATUS) RUNNING 46 W4 W4 06
00GCP12AP001
00GCY00GH001
NO FAULT 48 W5 W5 08
MCC-04BJE08FD
2C SP 2C SP
SHIELD SG
42 W1 W1 17
RUN
FLUSHING PUMP - B 41 W2 04BJE08FD-C0004 W2 18
TB67 PLC PANEL
(RUN/STOP 43 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 19
04BJE07FH 00GCY00GH001
COMMAND) STOP
-XM4 44 W4 W4 20
00GCP12AP001
MCC-04BJE08FD 1C SP 1C SP
SHIELD SG
COM 45 W1 W1 01
SHIELD SG
42 W1 W1 49
AIR BLOWER - A FOR RUN
41 W2 04BJE06FB-C0004 W2 50
MMF TB64 PLC PANEL
(RUN/STOP 04BJE05FF 43 W3 W3 51
STOP 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
COMMAND) -XM3 44 W4 W4 52
00GBC11AN001
MCC-04BJE06FB 1C SP 1C SP
SHIELD SG
COM 55 W1 W1 09
52 W1 W1 61
AIR BLOWER - B FOR RUN
51 W2 04BJE06FC-C0004 W2 62
MMF TB65 PLC PANEL
(RUN/STOP 04BJE05FF 53 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 63
STOP 00GCY00GH001
COMMAND) -XM3 54 W4 W4 64
00GBC12AN001
MCC-04BJE06FC 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 5 W1 W1 25
2 W1 W1 29
CAUSTIC UNLOADING RUN
1 W2 04BJE05FB-C0004 W2 30
TRANSFER PUMP -A TB67 PLC PANEL
(RUN/STOP 04BJE05FF 3 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 31
STOP 00GCY00GH001
COMMAND) -XM3 4 W4 W4 32
00GCN11AP001
MCC-04BJE05FB 1C SP 1C SP
SHIELD SG
COM 15 W1 W1 01
SHIELD SG
12 W1 W1 33
CAUSTIC UNLOADING RUN
11 W2 04BJE05FC-C0004 W2 34
TRANSFER PUMP -B TB67 PLC PANEL
(RUN/STOP 04BJE05FF 13 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 35
STOP 00GCY00GH001
COMMAND) -XM3 14 W4 W4 36
00GCN12AP001
MCC-04BJE05FC 1C SP 1C SP
SHIELD SG
COM 25 W1 W1 09
SULFURIC ACID
UNLOADING REM 29 W2 W2 10
04BJE05FF 04BJE05FD-C0003
TRANSFER STOPPED 27 W3 W3 12 TB15
-XM3 0.6/1kV CU/PVC/PVC/OS 7Cx1.5
PUMP - A PLC PANEL
RUNNING 26 W4 W4 14
(REM/STOP/RUN/FAUL 00GCY00GH001
T STATUS) NO FAULT 28 W5 W5 16
00GCN21AP001 2C SP 2C SP
MCC-04BJE05FD
SHIELD SG
SULFURIC ACID 22 W1 W1 37
UNLOADING RUN
21 W2 04BJE05FD-C0004 W2 38
TRANSFER TB67 PLC PANEL
PUMP - A 04BJE05FF 23 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 39
STOP 00GCY00GH001
(RUN/STOP -XM3 24 W4 W4 40
COMMAND)
00GCN21AP001 1C SP 1C SP
MCC-04BJE05FD SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 35 W1 W1 25
SULFURIC ACID
UNLOADING REM 39 W2 W2 26
04BJE05FF 04BJE05FE-C0003
TRANSFER STOPPED 37 W3 W3 28 TB16
-XM3 0.6/1kV CU/PVC/PVC/OS 7Cx1.5
PUMP - B PLC PANEL
RUNNING 36 W4 W4 30
(REM/STOP/RUN/FAUL 00GCY00GH001
T STATUS) NO FAULT 38 W5 W5 32
00GCN22AP001 2C SP 2C SP
MCC-04BJE05FE
SHIELD SG
SULFURIC ACID 32 W1 W1 41
UNLOADING RUN
31 W2 04BJE05FE-C0004 W2 42
TRANSFER TB66 PLC PANEL
PUMP - B 04BJE05FF 33 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 43
STOP 00GCY00GH001
(RUN/STOP -XM3 34 W4 W4 44
COMMAND)
00GCN22AP001 1C SP 1C SP
MCC-04BJE05FE SHIELD SG
COM 71 W1 W1 09
SHIELD SG
68 W1 W1 37
SBS DOSING PUMP - A RUN
67 W2 04BJE01RF-C0004 W2 38
FOR SWRO TB68 PLC PANEL
(RUN/STOP 04BJE01FB 69 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 39
STOP 00GCY00GH001
COMMAND) -XM1 70 W4 W4 40
00GCN62AP001
MCC-04BJE01RF 1C SP 1C SP
SHIELD SG
COM 81 W1 W1 17
78 W1 W1 41
SBS DOSING PUMP - B RUN
77 W2 04BJE01RG-C0004 W2 42
FOR SWRO TB68 PLC PANEL
(RUN/STOP 04BJE01FB 79 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 43
STOP 00GCY00GH001
COMMAND) -XM1 80 W4 W4 44
00GCN63AP001
MCC-04BJE01RG 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 91 W1 W1 01
NaOCl DOSING PUMP - REM 95 W2 W2 02
A FOR POTABLE 04BJE01FB 04BJE02RB-C0003
STOPPED 93 W3 W3 04 TB23
WATER -XM1 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 92 W4 W4 06
T STATUS)
00GCY00GH001
NO FAULT 94 W5 W5 08
00GKD31AP001
MCC-04BJE02RB 2C SP 2C SP
SHIELD SG
88 W1 W1 33
NaOCl DOSING PUMP - RUN
A FOR POTABLE 87 W2 04BJE02RB-C0004 W2 34
TB69 PLC PANEL
WATER 89 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 35
04BJE01FB
(RUN/STOP STOP 00GCY00GH001
-XM1 90 W4 W4 36
COMMAND)
00GKD31AP001 1C SP 1C SP
MCC-04BJE02RB
SHIELD SG
COM 101 W1 W1 05
NaOCl DOSING PUMP - REM 105 W2 W2 06
B FOR POTABLE 04BJE01FB 04BJE02RC-C0003
STOPPED 103 W3 W3 08 TB24
WATER -XM1 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 102 W4 W4 10
00GCY00GH001
SHIELD SG
98 W1 W1 05
NaOCl DOSING PUMP - RUN
B FOR POTABLE 97 W2 04BJE02RC-C0004 W2 06
TB68 PLC PANEL
WATER 99 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 07
04BJE01FB 00GCY00GH001
(RUN/STOP STOP
-XM1 100 W4 W4 08
COMMAND)
00GKD32AP001 1C SP 1C SP
MCC-04BJE02RC
SHIELD SG
COM 111 W1 W1 01
COAGULANT DOSING REM 115 W2 W2 02
PUMP -A FOR 04BJE01FB 04BJE02RD-C0003
STOPPED 113 W3 W3 04 TB05
CLARIFIER FOR WT ( -XM1 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 112 W4 W4 06
T STATUS)
00GCY00GH001
NO FAULT 114 W5 W5 08
00GBN21AP001
MCC-04BJE02RD 2C SP 2C SP
SHIELD SG
108 W1 W1 01
COAGULANT DOSING RUN
PUMP -A FOR 107 W2 04BJE02RD-C0004 W2 02
TB65 PLC PANEL
CLARIFIER FOR WT ( 109 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 03
04BJE01FB
(RUN/STOP STOP 00GCY00GH001
-XM1 110 W4 W4 04
COMMAND)
00GBN21AP001 1C SP 1C SP
MCC-04BJE02RD
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 121 W1 W1 09
COAGULANT DOSING REM 125 W2 W2 10
PUMP -B FOR 04BJE01FB 04BJE02RE-C0003
STOPPED 123 W3 W3 12 TB06
CLARIFIER FOR WT -XM1 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 122 W4 W4 14
T STATUS)
00GCY00GH001
NO FAULT 124 W5 W5 16
00GBN22AP001
MCC-04BJE02RE 2C SP 2C SP
SHIELD SG
118 W1 W1 09
COAGULANT DOSING RUN
PUMP -B FOR 117 W2 04BJE02RE-C0004 W2 10
TB64 PLC PANEL
CLARIFIER FOR WT 119 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 11
04BJE01FB
(RUN/STOP STOP 00GCY00GH001
-XM1 120 W4 W4 12
COMMAND)
00GBN22AP001 1C SP 1C SP
MCC-04BJE02RE
SHIELD SG
COM 31 W1 W1 01
SHIELD SG
28 W1 W1 17
NaHCO3 DOSING RUN
27 W2 04BJE01RB-C0004 W2 18
PUMP - A FOR SWRO TB69 PLC PANEL
(RUN/STOP 04BJE01FB 29 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 19
STOP 00GCY00GH001
COMMAND) -XM1 30 W4 W4 20
00GCN91AP001
MCC-04BJE01RB 1C SP 1C SP
SHIELD SG
COM 41 W1 W1 09
38 W1 W1 21
NaHCO3 DOSING RUN
37 W2 04BJE01RC-C0004 W2 22
PUMP - B FOR SWRO TB69 PLC PANEL
(RUN/STOP 04BJE01FB 39 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 23
STOP 00GCY00GH001
COMMAND) -XM1 40 W4 W4 24
00GCN92AP001
MCC-04BJE01RC 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 105 W1 W1 01
POLYMER DOSING REM 109 W2 W2 02
PUMP-A FOR 04BJE03FD 04BJE04RC-C0003
STOPPED 107 W3 W3 04 TB06
CLARIFIER FOR WT -XM2 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 106 W4 W4 06
T STATUS)
00GCY00GH001
NO FAULT 108 W5 W5 08
00GBN41AP001
MCC-04BJE04RC 2C SP 2C SP
SHIELD SG
102 W1 W1 17
POLYMER DOSING RUN
PUMP-A FOR 101 W2 04BJE04RC-C0004 W2 18
TB65 PLC PANEL
CLARIFIER FOR WT 103 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 19
04BJE03FD
(RUN/STOP STOP 00GCY00GH001
-XM2 104 W4 W4 20
COMMAND)
00GBN41AP001 1C SP 1C SP
MCC-04BJE04RC
SHIELD SG
COM 115 W1 W1 09
POLYMER DOSING REM 119 W2 W2 10
PUMP-B FOR 04BJE03FD 04BJE04RD-C0003
STOPPED 117 W3 W3 12 TB05
CLARIFIER FOR WT -XM2 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 116 W4 W4 14
00GCY00GH001
SHIELD SG
112 W1 W1 21
POLYMER DOSING RUN
PUMP-B FOR 111 W2 04BJE04RD-C0004 W2 22
TB64 PLC PANEL
CLARIFIER FOR WT 113 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 23
04BJE03FD 00GCY00GH001
(RUN/STOP STOP
-XM2 114 W4 W4 24
COMMAND)
00GBN42AP001 1C SP 1C SP
MCC-04BJE04RD
SHIELD SG
COM 125 W1 W1 17
POLYMER DOSING REM 129 W2 W2 18
PUMP-C FOR 04BJE03FD 04BJE04RE-C0003
STOPPED 127 W3 W3 20 TB06
CLARIFIER FOR WT -XM2 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 126 W4 W4 22
T STATUS)
00GCY00GH001
NO FAULT 128 W5 W5 24
00GBN43AP001
MCC-04BJE04RE 2C SP 2C SP
SHIELD SG
122 W1 W1 25
POLYMER DOSING RUN
PUMP-C FOR 121 W2 04BJE04RE-C0004 W2 26
TB65 PLC PANEL
CLARIFIER FOR WT 123 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 27
04BJE03FD
(RUN/STOP STOP 00GCY00GH001
-XM2 124 W4 W4 28
COMMAND)
00GBN43AP001 1C SP 1C SP
MCC-04BJE04RE
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 75 W1 W1 25
AGITATOR FOR REM 79 W2 W2 26
ANTISCALANT DOSING 04BJE07FH 04BJE08RD-C0003
STOPPED 77 W3 W3 28 TB19
TANK -XM4 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 76 W4 W4 30
T STATUS)
00GCY00GH001
NO FAULT 78 W5 W5 32
00GCN71AM001
MCC-04BJE08RD 2C SP 2C SP
SHIELD SG
72 W1 W1 45
AGITATOR FOR RUN
ANTISCALANT DOSING 71 W2 04BJE08RD-C0004 W2 46
TB68 PLC PANEL
TANK 73 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 47
04BJE07FH
(RUN/STOP STOP 00GCY00GH001
-XM4 74 W4 W4 48
COMMAND)
00GCN71AM001 1C SP 1C SP
MCC-04BJE08RD
SHIELD SG
COM 65 W1 W1 17
SHIELD SG
62 W1 W1 57
CAUSTIC DOSING RUN
61 W2 04BJE03RD-C0004 W2 58
PUMP - A FOR MBP TB67 PLC PANEL
(RUN/STOP 04BJE03FD 63 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 59
STOP 00GCY00GH001
COMMAND) -XM2 64 W4 W4 60
00GCN42AP001
MCC-04BJE03RD 1C SP 1C SP
SHIELD SG
COM 75 W1 W1 17
72 W1 W1 57
CAUSTIC DOSING RUN
71 W2 04BJE03RE-C0004 W2 58
PUMP - B FOR MBP TB66 PLC PANEL
(RUN/STOP 04BJE03FD 73 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 59
STOP 00GCY00GH001
COMMAND) -XM2 74 W4 W4 60
00GCN43AP001
MCC-04BJE03RE 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 125 W1 W1 01
SULFURIC ACID REM 129 W2 W2 02
DOSING PUMP - A FOR 04BJE05FF 04BJE06RB-C0003
STOPPED 127 W3 W3 04 TB18
MBP -XM3 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 126 W4 W4 06
T STATUS)
00GCY00GH001
NO FAULT 128 W5 W5 08
00GCN51AP001
MCC-04BJE06RB 2C SP 2C SP
SHIELD SG
122 W1 W1 17
SULFURIC ACID RUN
DOSING PUMP - A FOR 121 W2 04BJE06RB-C0004 W2 18
TB68 PLC PANEL
MBP 123 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 19
04BJE05FF
(RUN/STOP STOP 00GCY00GH001
-XM3 124 W4 W4 20
COMMAND)
00GCN51AP001 1C SP 1C SP
MCC-04BJE06RB
SHIELD SG
COM 135 W1 W1 09
SULFURIC ACID REM 139 W2 W2 10
DOSING PUMP - B FOR 04BJE05FF 04BJE06RC-C0003
STOPPED 137 W3 W3 12 TB17
MBP -XM3 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 136 W4 W4 14
00GCY00GH001
SHIELD SG
132 W1 W1 49
SULFURIC ACID RUN
DOSING PUMP - B FOR 131 W2 04BJE06RC-C0004 W2 50
TB69 PLC PANEL
MBP 133 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 51
04BJE05FF 00GCY00GH001
(RUN/STOP STOP
-XM3 134 W4 W4 52
COMMAND)
00GCN52AP001 1C SP 1C SP
MCC-04BJE06RC
SHIELD SG
COM 65 W1 W1 25
62 W1 W1 13
AGITATOR FOR RUN
61 W2 04BJE06FD-C0004 W2 14
NaHCO3 DOSING TANK TB69 PLC PANEL
(RUN/STOP 04BJE05FF 63 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 15
STOP 00GCY00GH001
COMMAND) -XM3 64 W4 W4 16
GCN91AM001
MCC-04BJE06FD 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 75 W1 W1 01
72 W1 W1 01
AGITATOR FOR CaCl2 RUN
71 W2 04BJE06FE-C0004 W2 02
DOSING TANK TB69 PLC PANEL
(RUN/STOP 04BJE05FF 73 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 03
STOP 00GCY00GH001
COMMAND) -XM3 74 W4 W4 04
00GCN81AM001
MCC-04BJE06FE 1C SP 1C SP
SHIELD SG
COM 85 W1 W1 01
SHIELD SG
82 W1 W1 01
CAUSTIC DOSING RUN
81 W2 04BJE03RF-C0004 W2 02
PUMP - A FOR SWRO TB68 PLC PANEL
(RUN/STOP 04BJE03FD 83 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 03
STOP 00GCY00GH001
COMMAND) -XM2 84 W4 W4 04
00GCN44AP001
MCC-04BJE03RF 1C SP 1C SP
SHIELD SG
COM 95 W1 W1 09
92 W1 W1 37
CAUSTIC DOSING RUN
91 W2 04BJE03RG-C0004 W2 38
PUMP - B FOR SWRO TB69 PLC PANEL
(RUN/STOP 04BJE03FD 93 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 39
STOP 00GCY00GH001
COMMAND) -XM2 94 W4 W4 40
00GCN45AP001
MCC-04BJE03RG 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 85 W1 W1 09
82 W1 W1 05
CaCl2 DOSING PUMP - RUN
81 W2 04BJE05RB-C0004 W2 06
A FOR SWRO TB69 PLC PANEL
(RUN/STOP 04BJE05FF 83 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 07
STOP 00GCY00GH001
COMMAND) -XM3 84 W4 W4 08
00GCN82AP001
MCC-04BJE05RB 1C SP 1C SP
SHIELD SG
COM 95 W1 W1 17
SHIELD SG
92 W1 W1 09
CaCl2 DOSING PUMP - RUN
91 W2 04BJE05RC-C0004 W2 10
B FOR SWRO TB69 PLC PANEL
(RUN/STOP 04BJE05FF 93 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 11
STOP 00GCY00GH001
COMMAND) -XM3 94 W4 W4 12
00GCN83AP001
MCC-04BJE05RC 1C SP 1C SP
SHIELD SG
COM 31 W1 W1 17
IRREGULAR REM 35 W2 W2 18
WASTEWATER PUMP - 04BJF01FB 04BJF02RB-C0003
STOPPED 33 W3 W3 20 TB25
A -XM1 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 32 W4 W4 22
T STATUS)
00GCY00GH001
NO FAULT 34 W5 W5 24
00GNK21AP001
MCC-04BJF02RB 2C SP 2C SP
SHIELD SG
28 W1 W1 09
IRREGULAR RUN
WASTEWATER PUMP - 27 W2 04BJF02RB-C0004 W2 10
TB70 PLC PANEL
A 29 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 11
04BJF01FB
(RUN/STOP STOP 00GCY00GH001
-XM1 30 W4 W4 12
COMMAND)
00GNK21AP001 1C SP 1C SP
MCC-04BJF02RB
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 41 W1 W1 25
IRREGULAR REM 45 W2 W2 26
WASTEWATER PUMP - 04BJF01FB 04BJF02RC-C0003
STOPPED 43 W3 W3 28 TB26
B -XM1 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 42 W4 W4 30
T STATUS)
00GCY00GH001
NO FAULT 44 W5 W5 32
00GNK22AP001
MCC-04BJF02RC 2C SP 2C SP
SHIELD SG
38 W1 W1 25
IRREGULAR RUN
WASTEWATER PUMP - 37 W2 04BJF02RC-C0004 W2 26
TB71 PLC PANEL
B 39 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 27
04BJF01FB
(RUN/STOP STOP 00GCY00GH001
-XM1 40 W4 W4 28
COMMAND)
00GNK22AP001 1C SP 1C SP
MCC-04BJF02RC
SHIELD SG
COM 145 W1 W1 01
SHIELD SG
142 W1 W1 17
WASTEWATER PUMP - RUN
141 W2 04BJF06RD-C0004 W2 18
A TB70 PLC PANEL
(RUN/STOP 04BJF05FF- 143 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 19
STOP 00GCY00GH001
COMMAND) XM3 144 W4 W4 20
00GNK31AP001
MCC-04BJF06RD 1C SP 1C SP
SHIELD SG
COM 155 W1 W1 09
152 W1 W1 37
WASTEWATER PUMP - RUN
151 W2 04BJF06RE-C0004 W2 38
B TB71 PLC PANEL
(RUN/STOP 04BJF05FF- 153 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 39
STOP 00GCY00GH001
COMMAND) XM3 154 W4 W4 40
00GNK32AP001
MCC-04BJF06RE 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 11 W1 W1 01
8 W1 W1 01
AIR BLOWER - A FOR RUN
7 W2 04BJF01RC-C0004 W2 02
WWT TB70 PLC PANEL
(RUN/STOP 04BJF01FB 9 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 03
STOP 00GCY00GH001
COMMAND) -XM1 10 W4 W4 04
00GRC21AN001
MCC-04BJF01RC 1C SP 1C SP
SHIELD SG
COM 21 W1 W1 09
SHIELD SG
18 W1 W1 09
AIR BLOWER - B FOR RUN
17 W2 04BJF01RD-C0004 W2 10
WWT TB71 PLC PANEL
(RUN/STOP 04BJF01FB 19 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 11
STOP 00GCY00GH001
COMMAND) -XM1 20 W4 W4 12
00GRC22AN001
MCC-04BJF01RD 1C SP 1C SP
SHIELD SG
COM 65 W1 W1 09
62 W1 W1 37
AGITATOR FOR pH RUN
61 W2 04BJF03RD-C0004 W2 38
ADJUSTMENT TANK TB70 PLC PANEL
(RUN/STOP 04BJF03FG 63 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 39
STOP 00GCY00GH001
COMMAND) -XM2 64 W4 W4 40
00GNL50AM001
MCC-04BJF03RD 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 65 W1 W1 17
62 W1 W1 41
AGITATOR FOR RUN
61 W2 04BJF06FE-C0004 W2 42
COAGULATION TANK TB70 PLC PANEL
(RUN/STOP 04BJF05FF- 63 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 43
STOP 00GCY00GH001
COMMAND) XM3 64 W4 W4 44
00GNL50AM002
MCC-04BJF06FE 1C SP 1C SP
SHIELD SG
COM 45 W1 W1 25
SHIELD SG
42 W1 W1 45
AGITATOR -A FOR RUN
41 W2 04BJF06FC-C0004 W2 46
FLOCCULATION TANK TB70 PLC PANEL
(RUN/STOP 04BJF05FF- 43 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 47
STOP 00GCY00GH001
COMMAND) XM3 44 W4 W4 48
00GNL50AM003
MCC-04BJF06FC 1C SP 1C SP
SHIELD SG
COM 55 W1 W1 01
52 W1 W1 53
AGITATOR -B FOR RUN
51 W2 04BJF06FD-C0004 W2 54
FLOCCULATION TANK TB71 PLC PANEL
(RUN/STOP 04BJF05FF- 53 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 55
STOP 00GCY00GH001
COMMAND) XM3 54 W4 W4 56
00GNL50AM004
MCC-04BJF06FD 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 5 W1 W1 09
2 W1 W1 53
CYCLO REDUCER FOR RUN
1 W2 04BJF05FB-C0004 W2 54
WWT TB70 PLC PANEL
(RUN/STOP 04BJF05FF- 3 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 55
STOP 00GCY00GH001
COMMAND) XM3 4 W4 W4 56
00GND20AM001
MCC-04BJF05FB 1C SP 1C SP
SHIELD SG
COM 45 W1 W1 17
SLUDGE TRANSFER REM 49 W2 W2 18
PUMP - A FOR 04BJF03FG 04BJF03RB-C0003
STOPPED 47 W3 W3 20 TB28
CLARIFIER FOR WWT -XM2 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 46 W4 W4 22
00GCY00GH001
SHIELD SG
42 W1 W1 57
SLUDGE TRANSFER RUN
PUMP - A FOR 41 W2 04BJF03RB-C0004 W2 58
TB70 PLC PANEL
CLARIFIER FOR WWT 43 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 59
04BJF03FG 00GCY00GH001
(RUN/STOP STOP
-XM2 44 W4 W4 60
COMMAND)
00GRS11AP001 1C SP 1C SP
MCC-04BJF03RB
SHIELD SG
COM 55 W1 W1 25
SLUDGE TRANSFER REM 59 W2 W2 26
PUMP - B FOR 04BJF03FG 04BJF03RC-C0003
STOPPED 57 W3 W3 28 TB27
CLARIFIER FOR WWT -XM2 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 56 W4 W4 30
T STATUS)
00GCY00GH001
NO FAULT 58 W5 W5 32
00GRS12AP001
MCC-04BJF03RC 2C SP 2C SP
SHIELD SG
52 W1 W1 61
SLUDGE TRANSFER RUN
PUMP - B FOR 51 W2 04BJF03RC-C0004 W2 62
TB71 PLC PANEL
CLARIFIER FOR WWT 53 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 63
04BJF03FG
(RUN/STOP STOP 00GCY00GH001
-XM2 54 W4 W4 64
COMMAND)
00GRS12AP001 1C SP 1C SP
MCC-04BJF03RC
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 15 W1 W1 01
12 W1 W1 01
CYCLO REDUCER FOR RUN
11 W2 04BJF05FC-C0004 W2 02
THICKENER TB71 PLC PANEL
(RUN/STOP 04BJF05FF- 13 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 03
STOP 00GCY00GH001
COMMAND) XM3 14 W4 W4 04
00GND40AM001
MCC-04BJF05FC 1C SP 1C SP
SHIELD SG
COM 165 W1 W1 09
SHIELD SG
162 W1 W1 05
THICKENED SLUDGE RUN
161 W2 04BJF06RF-C0004 W2 06
TRANSFER PUMP - A TB71 PLC PANEL
(RUN/STOP 04BJF05FF- 163 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 07
STOP 00GCY00GH001
COMMAND) XM3 164 W4 W4 08
00GND31AP001
MCC-04BJF06RF 1C SP 1C SP
SHIELD SG
COM 175 W1 W1 17
172 W1 W1 05
THICKENED SLUDGE RUN
171 W2 04BJF06RG-C0004 W2 06
TRANSFER PUMP - B TB70 PLC PANEL
(RUN/STOP 04BJF05FF- 173 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 07
STOP 00GCY00GH001
COMMAND) XM3 174 W4 W4 08
00GND32AP001
MCC-04BJF06RG 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 95 W1 W1 25
92 W1 W1 29
OILY WASTEWATER RUN
91 W2 04BJF04RC-C0004 W2 30
TRANSFER PUMP - A TB70 PLC PANEL
(RUN/STOP 04BJF03FG 93 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 31
STOP 00GCY00GH001
COMMAND) -XM2 94 W4 W4 32
00GNK61AP001
MCC-04BJF04RC 1C SP 1C SP
SHIELD SG
COM 105 W1 W1 01
SHIELD SG
102 W1 W1 45
OILY WASTEWATER RUN
101 W2 04BJF04RD-C0004 W2 46
TRANSFER PUMP - B TB71 PLC PANEL
(RUN/STOP 04BJF03FG 103 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 47
STOP 00GCY00GH001
COMMAND) -XM2 104 W4 W4 48
00GNK62AP001
MCC-04BJF04RD 1C SP 1C SP
SHIELD SG
COM 25 W1 W1 25
REM 29 W2 W2 26
EFFLUENT PUMP - A 04BJF03FG 04BJF04FD-C0003
STOPPED 27 W3 W3 28 TB29
(REM/STOP/RUN/FAUL -XM2 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
T STATUS) RUNNING 26 W4 W4 30
00GNK51AP001
00GCY00GH001
NO FAULT 28 W5 W5 32
MCC-04BJF04FD
2C SP 2C SP
SHIELD SG
22 W1 W1 13
RUN
EFFLUENT PUMP - A 21 W2 04BJF04FD-C0004 W2 14
TB71 PLC PANEL
(RUN/STOP 23 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 15
04BJF03FG
COMMAND) STOP 00GCY00GH001
-XM2 24 W4 W4 16
00GNK51AP001
MCC-04BJF04FD 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 35 W1 W1 01
REM 39 W2 W2 02
EFFLUENT PUMP - B 04BJF03FG 04BJF04FE-C0003
STOPPED 37 W3 W3 04 TB30
(REM/STOP/RUN/FAUL -XM2 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
T STATUS) RUNNING 36 W4 W4 06
00GNK52AP001
00GCY00GH001
NO FAULT 38 W5 W5 08
MCC-04BJF04FE
2C SP 2C SP
SHIELD SG
32 W1 W1 17
RUN
EFFLUENT PUMP - B 31 W2 04BJF04FE-C0004 W2 18
TB71 PLC PANEL
(RUN/STOP 33 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 19
04BJF03FG
COMMAND) STOP 00GCY00GH001
-XM2 34 W4 W4 20
00GNK52AP001
MCC-04BJF04FE 1C SP 1C SP
SHIELD SG
COM 25 W1 W1 25
SHIELD SG
22 W1 W1 29
FLOCCULANT FEED RUN
21 W2 04BJF05FD-C0004 W2 30
PUMP - A TB71 PLC PANEL
(RUN/STOP 04BJF05FF- 23 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 31
STOP 00GCY00GH001
COMMAND) XM3 24 W4 W4 32
00GNN11AP001
MCC-04BJF05FD 1C SP 1C SP
SHIELD SG
COM 35 W1 W1 01
32 W1 W1 33
FLOCCULANT FEED RUN
31 W2 04BJF05FE-C0004 W2 34
PUMP - B TB71 PLC PANEL
(RUN/STOP 04BJF05FF- 33 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 35
STOP 00GCY00GH001
COMMAND) XM3 34 W4 W4 36
00GNN12AP001
MCC-04BJF05FE 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 5 W1 W1 17
2 W1 W1 41
CAUSTIC DOSING RUN
1 W2 04BJF04FB-C0004 W2 42
PUMP - A TB71 PLC PANEL
(RUN/STOP 04BJF03FG 3 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 43
STOP 00GCY00GH001
COMMAND) -XM2 4 W4 W4 44
00GNN31AP001
MCC-04BJF04FB 1C SP 1C SP
SHIELD SG
COM 15 W1 W1 25
SHIELD SG
12 W1 W1 33
CAUSTIC DOSING RUN
11 W2 04BJF04FC-C0004 W2 34
PUMP - B TB70 PLC PANEL
(RUN/STOP 04BJF03FG 13 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 35
STOP 00GCY00GH001
COMMAND) -XM2 14 W4 W4 36
00GNN32AP001
MCC-04BJF04FC 1C SP 1C SP
SHIELD SG
COM 115 W1 W1 17
112 W1 W1 57
COAGULATION RUN
111 W2 04BJF04RE-C0004 W2 58
DOSING PUMP-A TB71 PLC PANEL
(RUN/STOP 04BJF03FG 113 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 59
STOP 00GCY00GH001
COMMAND) -XM2 114 W4 W4 60
00GNN51AP001
MCC-04BJF04RE 1C SP 1C SP
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 125 W1 W1 25
122 W1 W1 61
COAGULATION RUN
121 W2 04BJF04RF-C0004 W2 62
DOSING PUMP-B TB70 PLC PANEL
(RUN/STOP 04BJF03FG 123 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 63
STOP 00GCY00GH001
COMMAND) -XM2 124 W4 W4 64
00GNN52AP001
MCC-04BJF04RF 1C SP 1C SP
SHIELD SG
COM 125 W1 W1 01
SULFURIC ACID REM 129 W2 W2 02
DOSING PUMP-A FOR 04BJF05FF- 04BJF06RB-C0003
STOPPED 127 W3 W3 04 TB32
pH ADJUSTMENT TANK XM3 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 126 W4 W4 06
00GCY00GH001
SHIELD SG
122 W1 W1 49
SULFURIC ACID RUN
DOSING PUMP-A FOR 121 W2 04BJF06RB-C0004 W2 50
TB71 PLC PANEL
pH ADJUSTMENT TANK 123 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 51
04BJF05FF- 00GCY00GH001
(RUN/STOP STOP
XM3 124 W4 W4 52
COMMAND)
00GNN41AP001 1C SP 1C SP
MCC-04BJF06RB
SHIELD SG
COM 135 W1 W1 09
SULFURIC ACID REM 139 W2 W2 10
DOSING PUMP-B FOR 04BJF05FF- 04BJF06RC-C0003
STOPPED 137 W3 W3 12 TB31
pH ADJUSTMENT TANK XM3 0.6/1kV CU/PVC/PVC/OS 7Cx1.5 PLC PANEL
(REM/STOP/RUN/FAUL RUNNING 136 W4 W4 14
T STATUS)
00GCY00GH001
NO FAULT 138 W5 W5 16
00GNN42AP001
MCC-04BJF06RC 2C SP 2C SP
SHIELD SG
132 W1 W1 49
SULFURIC ACID RUN
DOSING PUMP-B FOR 131 W2 04BJF06RC-C0004 W2 50
TB70 PLC PANEL
pH ADJUSTMENT TANK 133 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 51
04BJF05FF-
(RUN/STOP STOP 00GCY00GH001
XM3 134 W4 W4 52
COMMAND)
00GNN42AP001 1C SP 1C SP
MCC-04BJF06RC
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 85 W1 W1 09
82 W1 W1 21
POLYMER DOSING RUN
81 W2 04BJF05RC-C0004 W2 22
PUMP - A FOR WWT TB71 PLC PANEL
(RUN/STOP 04BJF05FF- 83 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 23
STOP 00GCY00GH001
COMMAND) XM3 84 W4 W4 24
00GNN21AP001
MCC-04BJF05RC 1C SP 1C SP
SHIELD SG
COM 95 W1 W1 17
SHIELD SG
92 W1 W1 13
POLYMER DOSING RUN
91 W2 04BJF05RD-C0004 W2 14
PUMP - B FOR WWT TB70 PLC PANEL
(RUN/STOP 04BJF05FF- 93 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 15
STOP 00GCY00GH001
COMMAND) XM3 94 W4 W4 16
00GNN22AP001
MCC-04BJF05RD 1C SP 1C SP
SHIELD SG
COM 75 W1 W1 25
COAGULANT
UNLOADING REM 79 W2 W2 26
04BJF03FG 04BJF03RE-C0003
TRANSFER STOPPED 77 W3 W3 28 TB15
-XM2 0.6/1kV CU/PVC/PVC/OS 7Cx1.5
PUMP - A PLC PANEL
RUNNING 76 W4 W4 30
(REM/STOP/RUN/FAUL
00GCY00GH001
T STATUS) NO FAULT 78 W5 W5 32
00GCN31AP001
2C SP 2C SP
MCC-04BJF03RE
SHIELD SG
COAGULANT 72 W1 W1 45
UNLOADING RUN
71 W2 04BJF03RE-C0004 W2 46
TRANSFER TB67 PLC PANEL
PUMP - A 04BJF03FG 73 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 47
STOP 00GCY00GH001
(RUN/STOP -XM2 74 W4 W4 48
COMMAND)
00GCN31AP001 1C SP 1C SP
MCC-04BJF03RE SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM 85 W1 W1 01
COAGULANT
UNLOADING REM 89 W2 W2 02
04BJF03FG 04BJF03RF-C0003
TRANSFER STOPPED 87 W3 W3 04 TB16
-XM2 0.6/1kV CU/PVC/PVC/OS 7Cx1.5
PUMP - B PLC PANEL
RUNNING 86 W4 W4 06
(REM/STOP/RUN/FAUL 00GCY00GH001
T STATUS) NO FAULT 88 W5 W5 08
00GCN32AP001
2C SP 2C SP
MCC-04BJF03RF
SHIELD SG
COAGULANT 82 W1 W1 49
UNLOADING RUN
81 W2 04BJF03RF-C0004 W2 50
TRANSFER TB67 PLC PANEL
PUMP - B 04BJF03FG 83 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 51
STOP 00GCY00GH001
(RUN/STOP -XM2 84 W4 W4 52
COMMAND)
00GCN32AP001 1C SP 1C SP
MCC-04BJF03RF SHIELD SG
COM HOLD W1 W1 17
REM HOLD W2 W2 18
AGITATOR FOR SLUDGE MIXING TANK 04BJF35-C0003
(REM/STOP/RUN/FAULT STATUS) STOPPED HOLD W3 W3 20 TB26 PLC PANEL
0.6/1kV CU/PVC/PVC/OS 5Cx1.5
00GNB31AM001 RUNNING HOLD W4 W4 22 00GCY00GH001
COM HOLD W1 W1 26
AGITATOR FOR SLUDGE MIXING TANK RUN HOLD W2 W2 25 TB70
(RUN/STOP COMMAND) 04BJF35-C0004 PLC PANEL
STOP HOLD W3 W3 28
00GNB31AM001 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
MCC-04BJF35 SPARE HOLD W4 W4 SPARE
SPARE HOLD W5 W5 SPARE
SHIELD SG
[NOTE]
END
MCC ROOM
CONTINUED
COM. 21 W1 W1 01
TK LEVEL "HIGH" "HIGH" 22 W2 W2 02
TK LEVEL "HIGH" 23 W3 W3 04
TK LEVEL "LOW" 24 W4 W4 06
TK LEVEL "LOW LOW" 25 W5 W5 08
HOPPER LEVEL "LOW" 26 W6 W6 10
AGTATOR/1 "RUNNING" 27 W7 W7 12
AGTATOR/1 "TRIP" 28 W8 W8 14
00GBN40GH001-C0001
POLYMER AUTO AGTATOR/2 "RUNNING" TB-01 29 W9 W9 16
DISSOLVING UNIT 0.6/1kV CU/PVC/PVC/OS 20Cx1.5
FOR WT & WWT PKG. AGTATOR/2 "TRIP" 30 W10 W10 18 PLC PANEL
TB60
(A-POLYMER) AGTATOR/3 "RUNNING" 31 W11 W11 20 00GCY00GH001
[NOTE]
END
FIELD
CONTINUED
COM. 21 W1 W1 01
SPARE 22 W2 W2 02
TK LEVEL "HIGH" 23 W3 W3 04
TK LEVEL "LOW" 24 W4 W4 06
TK LEVEL "LOW LOW" 25 W5 W5 08
HOPPER LEVEL "LOW" 26 W6 W6 10
AGTATOR/1 "RUNNING" 27 W7 W7 12
AGTATOR/1 "TRIP" 28 W8 W8 14
00GNN10GH001-C0001
FLOCCULANT FEED AGTATOR/2 "RUNNING" TB-01 29 W9 W9 16
TANK(AUTO 0.6/1kV CU/PVC/PVC/OS 20Cx1.5
DISSOLVING UNIT) AGTATOR/2 "TRIP" 30 W10 W10 18 PLC PANEL
TB61
PKG.. (C-POLYMER) AGTATOR/3 "RUNNING" 31 W11 W11 20 00GCY00GH001
[NOTE]
END
FIELD
CONTINUED
COM. 22 W1 W1 01
TOTAL FAULT 23 W2 00GNB40GH001-C0002 W2 02
TB4
DEHYDRATOR SYSTEM READY 24 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 04 TB62 PLC PANEL
(FILTER PRESS) PKG.
00GNB40GH001 TOTAL RUNNING 25 W4 W4 06 00GCY00GH001
1C SP 1C SP
SHIELD SG
COM. 26 W1 W1 31
RUN 27 W2 00GNB40GH001-C0003 W2 32
DEHYDRATOR TB4 TB78 PLC PANEL
(FILTER PRESS) PKG. COM. 26 W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 33
00GNB40GH001
00GCY00GH001
MCC ROOM
STOP 28 W4 W4 34
1C SP 1C SP
SHIELD SG
[NOTE]
END
FIELD
CONTINUED
COM. 67-1 W1 W1 07
AIR BLOWER - A RUN STATUS (00GRC51AN001) 68 W2 00GRL10GH001-C0009 W2 08
AIR BLOWER - A FAULT (00GRC51AN001) 69 W3 0.6/1kV CU/PVC/PVC/OS 16Cx1.5 W3 10
AIR BLOWER - B STATUS (00GRC52AN001) 70 W4 W4 12
AIR BLOWER - B FAULT (00GRC52AN001) 71 W5 W5 14
EQUALIZATION PUMP-A STATUS (00GRK11AP001) 72 W6 W6 16
EQUALIZATION PUMP-A FAULT (00GRK11AP001) 73 W7 W7 18
T.B-2
EQUALIZATION PUMP-B STATUS (00GRK12AP001) 74 W8 W8 20 TB62
EQUALIZATION PUMP-B FAULT (00GRK12AP001) 75 W9 W9 22
INTERNAL RETURN PUMP - A STATUS
76 W10 W10 24
(00GRK21AP001)
INTERNAL RETURN PUMP - A FAULT
77 W11 W11 26
(00GRK21AP001)
INTERNAL RETURN PUMP - B STATUS
78 W12 W12 28
(00GRK22AP001)
INTERNAL RETURN PUMP - B FAULT
79 W13 W13 30
(00GRK22AP001)
EFFLUENT PUMP - A STATUS (00GRK41AP001) 80 W14 W14 32
SEWAGE TREATMENT
2C SP 2C SP
SYSTEM
00GRL10GH001 SHIELD SG PLC PANEL
COM. 90 W1 W1 01 00GCY00GH001
EFFLUENT PUMP - A FAULT (00GRK41AP001) 81 W2 W2 02
EFFLUENT PUMP - B STATUS (00GRK42AP001) 82 W3 00GRL10GH001-C0010 W3 04
EFFLUENT PUMP - B FAULT (00GRK42AP001) 83 W4 0.6/1kV CU/PVC/PVC/OS 16Cx1.5 W4 06
MIXER STATUS (00GRL11AM001) 84 W5 W5 08
[NOTE]
END
FIELD
CONTINUED
33 B1 B1 07
HI TDS SWRO HP PP - A MOTOR BEARING
34 W1 W1 08
NDE VIBRATION XMTR - 1 (00GCK41AP001A)
SHIELD 09
30 B2 B2 10
HI TDS SWRO HP PP - A MOTOR BEARING
31 W2 W2 11
DE VIBRATION XMTR - 1 (00GCK41AP001B) 00GCK41AP001-X0001
SHIELD 12
0.6/1kV CU/PVC/PVC/IS 6px1.5
8 B3 B3 13
HI TDS SWRO HP PP - A PP BEARING NDE
AUX. TB 9 W3 W3 14 TB80
VIBRATION XMTR - 1 (00GCK41AP001C)
SHIELD 15
5 B4 B4 16
HI TDS SWRO HP PP - A PP BEARING DE
6 W4 W4 17
VIBRATION XMTR - 1 (00GCK41AP001D)
SHIELD 18
1 B5 B5 19
HI TDS SWRO HP PP - A PP OIL SUMP TEMP
2 W5 W5 20
IND(PP BEARING TEMP) (00GCK41AP001J)
SHIELD 21
1p SP 1p SP
O'SHIELD SG
14 B2 B2 M
15 W2 W2 L CONVERTE
HI TDS SWRO HP PP - A WINDING TEMP IND -
R
2 (00GCK41AP001F) 16 R2 R2 K #2
00GCK41AP001-X0002
SHIELD
0.6/1kV CU/PVC/PVC/IS 8Tx1.5
17 B3 B3 M
18 W3 W3 L CONVERTE
HI TDS SWRO HP PP - A WINDING TEMP IND -
AUX. TB R
3 (00GCK41AP001G) 19 R3 R3 K #3
SHIELD
36 B4 B4 M
37 W4 W4 L CONVERTE
HI TDS SWRO HP PP - A MOTOR BEARING
R
DE TEMP IND (00GCK41AP001H) 38 R4 R4 K #4
SHIELD
39 B5 B5 M
40 W5 W5 L CONVERTE
HI TDS SWRO HP PP - A MOTOR BEARING
R
NDE TEMP IND (00GCK41AP001I) 41 R5 R5 K #5
SHIELD
3T SP 3T SP
O'SHIELD SG
[NOTE]
END
FIELD
CONTINUED
33 B1 B1 04
HI TDS SWRO HP PP - B MOTOR BEARING
34 W1 W1 05
NDE VIBRATION XMTR - 1 (00GCK42AP001A)
SHIELD 06
30 B2 B2 07
HI TDS SWRO HP PP - B MOTOR BEARING
31 W2 W2 08
DE VIBRATION XMTR - 1 (00GCK42AP001B) 00GCK42AP001-X0001
SHIELD 09
0.6/1kV CU/PVC/PVC/IS 6px1.5
8 B3 B3 10
HI TDS SWRO HP PP - B PP BEARING NDE
AUX. TB 9 W3 W3 11 TB82
VIBRATION XMTR - 1 (00GCK42AP001C)
SHIELD 12
5 B4 B4 13
HI TDS SWRO HP PP - B PP BEARING DE
6 W4 W4 14
VIBRATION XMTR - 1 (00GCK42AP001D)
SHIELD 15
1 B5 B5 16
HI TDS SWRO HP PP - B PP OIL SUMP TEMP
2 W5 W5 17
IND(PP BEARING TEMP) (00GCK42AP001J)
SHIELD 18
1p SP 1p SP
O'SHIELD SG
14 B2 B2 M
15 W2 W2 L CONVERTE
HI TDS SWRO HP PP - B WINDING TEMP IND -
R
2 (00GCK42AP001F) 16 R2 R2 K #2
00GCK42AP001-X0002
SHIELD
0.6/1kV CU/PVC/PVC/IS 8Tx1.5
17 B3 B3 M
18 W3 W3 L CONVERTE
HI TDS SWRO HP PP - B WINDING TEMP IND -
AUX. TB R
3 (00GCK42AP001G) 19 R3 R3 K #3
SHIELD
36 B4 B4 M
37 W4 W4 L CONVERTE
HI TDS SWRO HP PP - B MOTOR BEARING
R
DE TEMP IND (00GCK42AP001H) 38 R4 R4 K #4
SHIELD
39 B5 B5 M
40 W5 W5 L CONVERTE
HI TDS SWRO HP PP - B MOTOR BEARING
R
NDE TEMP IND (00GCK42AP001I) 41 R5 R5 K #5
SHIELD
3T SP 3T SP
O'SHIELD SG
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
SWRO HIGH PRESSURE PUMP A DRAIN OUTLET PRESS IND XMTR + B 00GCK31CP101-X0001 B 22
PLC PANEL
(SIGNAL) - W 0.6/1kV CU/PVC/PVC/OS 1px1.5 W 23 TB88
00GCY00GH001
00GCK31CP101 SHIELD 24
SWRO HIGH PRESSURE PUMP B DRAIN OUTLET PRESS IND XMTR + B 00GCK32CP101-X0001 B 07
PLC PANEL
(SIGNAL) - W 0.6/1kV CU/PVC/PVC/OS 1px1.5 W 08 TB89
00GCY00GH001
00GCK32CP101 SHIELD 09
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
O'SHIELD SG
SULFURIC ACID DOSING PUMP - A G B 00GBN11AP001-L0001 B 01
PTB08 PLC PANEL
SPD IND/CTRL FOR CLARIFIER FOR WT (POWER) G0 W 0.6/1kV CU/PVC/PVC/OS 2Cx2.5 W 02
00GCY00GH001
00GBN11AP001 SHIELD SG
O'SHIELD SG
SULFURIC ACID DOSING PUMP - B G B 00GBN12AP001-L0001 B 03
PTB08 PLC PANEL
SPD IND/CTRL FOR CLARIFIER FOR WT (POWER) G0 W 0.6/1kV CU/PVC/PVC/OS 2Cx2.5 W 04
00GCY00GH001
00GBN12AP001 SHIELD SG
[NOTE]
END
FIELD
CONTINUED
O'SHIELD SG
SBS DOSING PUMP - A SPD IND/CTRL FOR SWRO G B 00GCN62AP001-L0001 B 05
PTB08 PLC PANEL
(POWER) G0 W 0.6/1kV CU/PVC/PVC/OS 2Cx2.5 W 06
00GCY00GH001
00GCN62AP001 SHIELD SG
O'SHIELD SG
SBS DOSING PUMP - A SPD IND/CTRL FOR SWRO G B 00GCN63AP001-L0001 B 07
PTB08 PLC PANEL
(POWER) G0 W 0.6/1kV CU/PVC/PVC/OS 2Cx2.5 W 08
00GCY00GH001
00GCN63AP001 SHIELD SG
[NOTE]
END
FIELD
CONTINUED
O'SHIELD SG
SULFURIC ACID DOSING PUMP- A SPD IND/CTRL FOR SWRO G B 00GCN15AP001-L0001 B 09
PTB08 PLC PANEL
(POWER) G0 W 0.6/1kV CU/PVC/PVC/OS 2Cx2.5 W 10
00GCY00GH001
00GCN15AP001 SHIELD SG
O'SHIELD SG
SULFURIC ACID DOSING PUMP- B SPD IND/CTRL FOR SWRO G B 00GCN16AP001-L0001 B 11
PTB08 PLC PANEL
(POWER) G0 W 0.6/1kV CU/PVC/PVC/OS 2Cx2.5 W 12
00GCY00GH001
00GCN16AP001 SHIELD SG
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
+ W1 W1 05
OPEN LIMIT SWITCH
- W2 00GCN13AA252-C0002 W2 06
CAUSTIC DOSING PLC PANEL
TANK FOR CALARIFIER + W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 07 TB53
CLOSE LIMIT SWITCH 00GCY00GH001
VALVE LIMIT SWITCH - W4 W4 08
00GCN13AA252
1C SP 1C SP
SHIELD
+ W1 W1 13
OPEN LIMIT SWITCH
- W2 00GNK53AA251-C0002 W2 14
TO WASTEWATER PLC PANEL
STORAGE POND INLET + W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 15 TB53
CLOSE LIMIT SWITCH 00GCY00GH001
VALVE LIMIT SWITCH - W4 W4 16
00GNK53AA251
W5 1C SP 1C SP
SHIELD
+ W1 W1 17
OPEN LIMIT SWITCH
TO PURIFIED - W2 00GNK53AA252-C0002 W2 18
WASTEWATER PIT PLC PANEL
+ W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 19 TB53
INLET CLOSE LIMIT SWITCH 00GCY00GH001
VALVE LIMIT SWITCH - W4 W4 20
+ W1 W1 21
OPEN LIMIT SWITCH
- W2 00GCP13AA251-C0002 W2 22
FLUSHING PUMP PLC PANEL
OUTLET + W3 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 W3 23 TB53
CLOSE LIMIT SWITCH 00GCY00GH001
VALVE LIMIT SWITCH - W4 W4 24
00GCP13AA251
1C SP 1C SP
SHIELD
COM. COM W1 W1 01
COM. COM W1 W1 09
LEVEL "HIGH HIGH" HH (NC) W2 W2 10
CAUSTIC DOSING 00GBN30CL201-C0001 PLC PANEL
TANK FOR CALARIFIER LEVEL "HIGH" H (NO) W3 W3 12 TB54
0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
LEVEL SWITCH LEVEL "LOW" L (NO) W4 W4 14
00GBN30CL201
LEVEL "LOW LOW" LL (NC) W5 W5 16
SHIELD
[NOTE]
END
FIELD
CONTINUED
COM. COM W1 W1 17
COM. COM W1 W1 25
LEVEL "HIGH HIGH" HH (NC) W2 W2 26
SUMP PIT 00GMG10CL201-C0001 PLC PANEL
LEVEL "HIGH" H (NO) W3 W3 28 TB54
LEVEL SWITCH 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
00GMG10CL201 LEVEL "LOW" L (NO) W4 W4 30
LEVEL "LOW LOW" LL (NC) W5 W5 32
SHIELD
COM. COM W1 W1 01
LEVEL "HIGH HIGH" HH (NC) W2 W2 02
00GCB10CL201-C0001 PLC PANEL
CIP TANK LEVEL "HIGH" H (NO) W3 W3 04 TB55
LEVEL SWITCH 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
00GCB10CL201 LEVEL "LOW" L (NO) W4 W4 06
COM. COM W1 W1 09
LEVEL "HIGH HIGH" HH W2 W2 10
00GCP20CL201-C0001 PLC PANEL
HOT WATER TANK LEVEL "HIGH" H (NO) W3 W3 12 TB55
LEVEL SWITCH 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
00GCP20CL201 LEVEL "LOW" L (NO) W4 W4 14
LEVEL "LOW LOW" LL (NC) W5 W5 16
SHIELD
COM. COM W1 W1 17
LEVEL "HIGH HIGH" HH (NC) W2 W2 18
CAUSTIC DOSING 00GCN40CL201-C0001 PLC PANEL
TANK LEVEL "HIGH" H (NO) W3 W3 20 TB55
0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
LEVEL SWITCH LEVEL "LOW" L (NO) W4 W4 22
00GCN40CL201
LEVEL "LOW LOW" LL (NC) W5 W5 24
SHIELD
COM. COM W1 W1 25
SULFURIC ACID LEVEL "HIGH HIGH" HH (NC) W2 W2 26
00GCN50CL201-C0001 PLC PANEL
DOSING TANK FOR LEVEL "HIGH" H (NO) W3 W3 28 TB55
MBP 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
LEVEL SWITCH LEVEL "LOW" L (NO) W4 W4 30
00GCN50CL201 LEVEL "LOW LOW" LL (NC) W5 W5 32
SHIELD
[NOTE]
END
FIELD
CONTINUED
COM. COM W1 W1 01
LEVEL "HIGH HIGH" HH (NC) W2 W2 02
MMF BACKWASH & RO 00GMG20CL201-C0001 PLC PANEL
BRINE PIT LEVEL "HIGH" H (NO) W3 W3 04 TB56
0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
LEVEL SWITCH LEVEL "LOW" L (NO) W4 W4 06
00GMG20CL201
LEVEL "LOW LOW" LL (NC) W5 W5 08
SHIELD SG
COM. COM W1 W1 09
LEVEL "HIGH HIGH" HH (NC) W2 W2 10
00GCN60CL201-C0001 PLC PANEL
SBS DOSING TANK LEVEL "HIGH" H (NO) W3 W3 12 TB56
LEVEL SWITCH 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
00GCN60CL201 LEVEL "LOW" L (NO) W4 W4 14
LEVEL "LOW LOW" LL (NC) W5 W5 16
SHIELD SG
COM. COM W1 W1 17
LEVEL "HIGH HIGH" HH (NC) W2 W2 18
ANTISCALANT DOSING 00GCN70CL201-C0001 PLC PANEL
TANK FOR RO LEVEL "HIGH" H (NO) W3 W3 20 TB56
0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
LEVEL SWITCH LEVEL "LOW" L (NO) W4 W4 22
00GCN70CL201
COM. COM W1 W1 25
LEVEL "HIGH HIGH" HH (NC) W2 W2 26
CaCl2 DOSING FOR 00GCN80CL201-C0001 PLC PANEL
SWRO TANK LEVEL "HIGH" H (NO) W3 W3 28 TB56
0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
LEVEL SWITCH LEVEL "LOW" L (NO) W4 W4 30
00GCN80CL201
LEVEL "LOW LOW" LL (NC) W5 W5 32
SHIELD SG
COM. COM W1 W1 01
LEVEL "HIGH HIGH" HH (NC) W2 W2 02
NaHCO3 DOSING FOR 00GCN90CL201-C0001 PLC PANEL
SWRO TANK LEVEL "HIGH" H (NO) W3 W3 04 TB57
0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
LEVEL SWITCH LEVEL "LOW" L (NO) W4 W4 06
00GCN90CL201
LEVEL "LOW LOW" LL (NC) W5 W5 08
SHIELD SG
COM. COM W1 W1 09
LEVEL "HIGH HIGH" HH (NC) W2 W2 10
00GCR10CL201-C0001 PLC PANEL
NEUTRALIZATION PIT LEVEL "HIGH" H (NO) W3 W3 12 TB57
LEVEL SWITCH 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
00GCR10CL201 LEVEL "LOW" L (NO) W4 W4 14
LEVEL "LOW LOW" LL (NC) W5 W5 16
SHIELD SG
[NOTE]
END
FIELD
CONTINUED
COM. COM W1 W1 17
COM. COM W1 W1 25
LEVEL "HIGH HIGH" HH (NC) W2 W2 26
OILY WASTEWATER 00GNL60CL201-C0001 PLC PANEL
POND LEVEL "HIGH" H (NO) W3 W3 28 TB57
0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
LEVEL SWITCH LEVEL "LOW" L (NO) W4 W4 30
00GNL60CL201
LEVEL "LOW LOW" LL (NC) W5 W5 32
SHIELD SG
COM. COM W1 W1 01
LEVEL "HIGH HIGH" HH (NC) W2 W2 02
CAUSTIC DOSING 00GNN30CL201-C0001 PLC PANEL
TANK FOR WWT LEVEL "HIGH" H (NO) W3 W3 04 TB58
0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
LEVEL SWITCH LEVEL "LOW" L (NO) W4 W4 06
00GNN30CL201
COM. COM W1 W1 09
COM. COM B1 B1 17
LEVEL "HIGH HIGH" HH B2 B2 18
00GRL10CL201-C0001 PLC PANEL
EQULIZATION TANK LEVEL "HIGH" H B3 B3 20 TB58
LEVEL SWITCH-A 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
00GRL10CL201 LEVEL "LOW" L B4 B4 22
COM. COM B1 B1 25
LEVEL "HIGH HIGH" HH B2 B2 26
00GRL10CL202-C0001 PLC PANEL
EQULIZATION TANK LEVEL "HIGH" H B3 B3 28 TB58
LEVEL SWITCH-B 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 00GCY00GH001
00GRL10CL202 LEVEL "LOW" L B4 B4 30
LEVEL "LOW LOW" LL B5 B5 32
SHIELD SG
[NOTE]
END
FIELD
CONTINUED
COM. COM W1 W1 01
00GNB34CP201-C0001
PRESSURE "HIGH" H W2 W2 02
0.6/1kV CU/PVC/PVC/OS 5Cx1.5 PLC PANEL
FILTER PRESS INLET PRESSURE "LOW" L W3 W3 04 TB59
PRESSURE SWITCH 00GCY00GH001
2C SP 2C SP
00GNB34CP201
SHIELD SG
COM. COM W1 W1 05
00GCC20CP201-C0001
AIR RECEIVER FOR PRESSURE "HIGH" H W2 W2 06
0.6/1kV CU/PVC/PVC/OS 5Cx1.5 PLC PANEL
INSTRUMENT AIR PRESSURE "LOW" L W3 W3 08 TB59
OUTLET 00GCY00GH001
PRESSURE SWITCH CABLE SPARE 2C SP 2C SP
00GCC20CP201
SHIELD SG
COM. COM W1 W1 09
00GCC30CP201-C0001
PRESSURE "HIGH" H W2 W2 10
AIR RECEIVER FOR 0.6/1kV CU/PVC/PVC/OS 5Cx1.5 PLC PANEL
SERVICE AIR OUTLET PRESSURE "LOW" L W3 W3 12 TB59
00GCY00GH001
PRESSURE SWITCH CABLE SPARE 2C SP 2C SP
00GCC30CP201
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
[NOTE]
END
FIELD
CONTINUED
01 W1 00GBY30GH001-L0001 W1 01
PTB01 SOLENOID VALVE
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 02 PTB05 PANEL
(AUX. POWER)
SHIELD SG
01 W1 00GBY30GH001-C0001 W1 01
PTB02 SOLENOID VALVE
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 02 PTB06 PANEL
(VALVE POWER.)
SHIELD SG
01 W1 W1 01 00GBK31AA251
02 W2 W2 02 OPEN COMMAND
03 W3 W3 03 00GBK31AA252
04 W4 W4 04 OPEN COMMAND
05 W5 W5 05 00GBK31AA253
06 W6 W6 06 OPEN COMMAND
07 W7 W7 07 00GBK31AA254
08 W8 W8 08 OPEN COMMAND
09 W9 W9 09 00GBK31AA255
00GCY00GH001
PLC PANEL
15 W15 W15 15 00GBK31AA258
FIELD
SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
01 W1 W1 21 00GBK32AA251
02 W2 W2 22 OPEN COMMAND
03 W3 W3 23 00GBK32AA252
04 W4 W4 24 OPEN COMMAND
05 W5 W5 25 00GBK32AA253
06 W6 W6 26 OPEN COMMAND
07 W7 W7 27 00GBK32AA254
08 W8 W8 28 OPEN COMMAND
09 W9 W9 29 00GBK32AA255
10 W10 W10 30 OPEN COMMAND
00GBY30GH001-C0003
TB05 TB74
11 W11 0.6/1kV CU/ PVC/PVC/OS 20Cx1.5 W11 31 00GBK32AA256
12 W12 W12 32 OPEN COMMAND
SHIELD SG
00GCY00GH001
PLC PANEL
01 W1 W1 41 00GBK33AA251
FIELD
02 W2 W2 42 OPEN COMMAND
03 W3 W3 43 00GBK33AA252
04 W4 W4 44 OPEN COMMAND
05 W5 W5 45 00GBK33AA253
06 W6 W6 46 OPEN COMMAND
07 W7 W7 47 00GBK33AA254
08 W8 W8 48 OPEN COMMAND
09 W9 W9 49 00GBK33AA255
10 W10 W10 50 OPEN COMMAND
00GBY30GH001-C0004
TB06 TB74
11 W11 0.6/1kV CU/ PVC/PVC/OS 20Cx1.5 W11 51 00GBK33AA256
12 W12 W12 52 OPEN COMMAND
SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
00GCY00GH001
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
PLC PANEL
00GBK31AA256 CLOSE 3 W3 23 23 23 PLC PANEL
FIELD
SHIELD SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
00GCY00GH001
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
PLC PANEL
00GBK32AA256 CLOSE 3 W3 23 23 31 PLC PANEL
FIELD
SHIELD SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
00GCY00GH001
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
PLC PANEL
00GBK33AA256 CLOSE 3 W3 23 23 07 PLC PANEL
FIELD
SHIELD SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
01 W1 00GBY30GH002-L0001 W1 03
PTB01 SOLENOID VALVE
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 04 PTB05 PANEL
(AUX. POWER)
SHIELD SG
01 W1 00GBY30GH002-C0001 W1 03
PTB02 SOLENOID VALVE
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 04 PTB06 PANEL
(VALVE POWER.)
SHIELD SG
01 W1 W1 01 00GBK41AA251
02 W2 W2 02 OPEN COMMAND
03 W3 W3 03 00GBK41AA252
04 W4 W4 04 OPEN COMMAND
05 W5 W5 05 00GBK41AA253
06 W6 W6 06 OPEN COMMAND
07 W7 W7 07 00GBK41AA254
08 W8 W8 08 OPEN COMMAND
09 W9 W9 09 00GBK41AA255
00GCY00GH001
PLC PANEL
15 W15 W15 15 00GBK42AA252
FIELD
SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
01 W1 W1 21 00GBK42AA255
02 W2 W2 22 OPEN COMMAND
03 W3 W3 23 00GBK42AA256
04 W4 W4 24 OPEN COMMAND
05 W5 W5 25 00GBK43AA251
06 W6 W6 26 OPEN COMMAND
07 W7 W7 27 00GBK43AA252
08 W8 W8 28 OPEN COMMAND
09 W9 W9 29 00GBK43AA253
10 W10 W10 30 OPEN COMMAND
00GBY30GH002-C0003
TB04 TB75
11 W11 0.6/1kV CU/ PVC/PVC/OS 20Cx1.5 W11 31 00GBK43AA254
12 W12 W12 32 OPEN COMMAND
SHIELD SG
00GCY00GH001
PLC PANEL
FIELD
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
AC FILTER-A COM 1 W1 W1 1 1 W1 W1 25
XV-00GBK41AA251 00GBK41AA251-C0001
OPEN 2 W2 W2 2 2 W2 W2 26
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GBK41AA251 CLOSE 3 W3 3 3 27
2C SP W3 4 4 W3 W3 28
TB41
AC FILTER-A COM 1 W1 W1 5 5 29
XV-00GBK41AA252 00GBK41AA252-C0001
OPEN 2 W2 W2 6 6 W4 W4 30
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GBK41AA252 CLOSE 3 W3 7 7 31
2C SP W3 8 8 W5 W5 32
AC FILTER-A COM 1 W1 W1 9 9 W6 W6 01
XV-00GBK41AA253 00GBK41AA253-C0001
OPEN 2 W2 W2 10 10 W7 W7 02
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GBK41AA253 CLOSE 3 W3 11 11 03
2C SP W3 12 12 W8 W8 04
AC FILTER-A COM 1 W1 W1 13 13 05
XV-00GBK41AA254 00GBK41AA254-C0001
OPEN 2 W2 W2 14 14 W9 W9 06
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GBK41AA254 CLOSE 3 W3 15 15 07
2C SP W3 16 16 W10 W10 08
AC FILTER-A COM 1 W1 W1 17 17 09
00GCY00GH001
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
PLC PANEL
00GBK41AA256 CLOSE 3 W3 23 23 15 PLC PANEL
FIELD
SHIELD SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
AC FILTER-A COM 1 W1 W1 1 1 W1 W1 01
XV-00GBK42AA255 00GBK42AA255-C0001
OPEN 2 W2 W2 2 2 W2 W2 02
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GBK42AA255 CLOSE 3 W3 3 3 03
2C SP W3 4 4 W3 W3 04
AC FILTER-A COM 1 W1 W1 5 5 05
XV-00GBK42AA256 00GBK42AA256-C0001
OPEN 2 W2 W2 6 6 W4 W4 06
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GBK42AA256 CLOSE 3 W3 7 7 07
2C SP W3 8 8 W5 W5 08
AC FILTER-A COM 1 W1 W1 9 9 09
XV-00GBK43AA251 00GBK43AA251-C0001
OPEN 2 W2 W2 10 10 W6 W6 10
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GBK43AA251 CLOSE 3 W3 11 11 11
2C SP W3 12 12 W7 W7 12
AC FILTER-A COM 1 W1 W1 13 13 13
XV-00GBK43AA252 00GBK43AA252-C0001
OPEN 2 W2 W2 14 14 W8 W8 14
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GBK43AA252 CLOSE 3 W3 15 15 15
2C SP W3 16 16 W9 W9 16
TB43
AC FILTER-A COM 1 W1 W1 17 17 17
00GCY00GH001
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
PLC PANEL
00GBK43AA254 CLOSE 3 W3 23 23 23 PLC PANEL
FIELD
SHIELD SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
01 W1 00GCY30GH003-L0001 W1 05
PTB01 SOLENOID VALVE
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 06 PTB05 PANEL
(AUX. POWER)
SHIELD SG
01 W1 00GCY30GH003-C0001 W1 05
PTB02 SOLENOID VALVE
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 06 PTB06 PANEL
(VALVE POWER.)
SHIELD SG
01 W1 W1 41 00GCF31AA251
02 W2 W2 42 OPEN COMMAND
03 W3 W3 43 00GCF31AA252
04 W4 W4 44 OPEN COMMAND
05 W5 W5 45 00GCF31AA253
06 W6 W6 46 OPEN COMMAND
07 W7 W7 47 00GCF31AA254
08 W8 W8 48 OPEN COMMAND
09 W9 W9 49 00GCF31AA255
00GCY00GH001
PLC PANEL
15 W15 W15 55 00GCF31AA258
FIELD
SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
01 W1 W1 61 00GCF31AA261
02 W2 W2 62 OPEN COMMAND
TB75
03 W3 W3 63 00GCF31AA262
04 W4 W4 64 OPEN COMMAND
05 W5 W5 01 00GCF33AA251
06 W6 W6 02 OPEN COMMAND
07 W7 W7 03 00GCF33AA252
08 W8 W8 04 OPEN COMMAND
09 W9 W9 05 SPARE
10 W10 W10 06 OPEN COMMAND
00GCY30GH003-C0003
TB05
11 W11 0.6/1kV CU/ PVC/PVC/OS 20Cx1.5 W11 07 SPARE
12 W12 W12 08 OPEN COMMAND
TB76
13 W13 W13 09 00GCF32AA251
14 W14 W14 10 OPEN COMMAND
SHIELD SG
00GCY00GH001
PLC PANEL
01 W1 W1 17 00GCF32AA255
FIELD
02 W2 W2 18 OPEN COMMAND
03 W3 W3 19 00GCF32AA256
04 W4 W4 20 OPEN COMMAND
05 W5 W5 21 00GCF32AA257
06 W6 W6 22 OPEN COMMAND
07 W7 W7 23 00GCF32AA258
08 W8 W8 24 OPEN COMMAND
09 W9 W9 25 00GCF32AA259
10 W10 W10 26 OPEN COMMAND
00GCY30GH003-C0004
TB06 TB76
11 W11 0.6/1kV CU/ PVC/PVC/OS 20Cx1.5 W11 27 00GCF32AA260
12 W12 W12 28 OPEN COMMAND
SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
00GCY00GH001
VALVE OPEN LIMIT SWITCH
MIXED BED POLISHER A
PLC PANEL
XV-00GCF31AA256 COM 1 B 00GCF31AA256-C0002 B 23 23 31 PLC PANEL
FIELD
VALVE CLOSE LIMIT CLOSE 2 W 0.6/1kV CU/ PVC/PVC/OS 2Cx1.5 W 24 24 W13 W13 32 00GCY00GH001
SWITCH
MIXED BED POLISHER A COM 1 B B 25 25 W14 W14 01
00GCF31AA257-C0001
XV-00GCF31AA257
VALVE OPEN LIMIT SWITCH OPEN 2 W 0.6/1kV CU/ PVC/PVC/OS 2Cx1.5 W 26 26 W15 W15 02
MIXED BED POLISHER A
XV-00GCF31AA257 COM 1 B 00GCF31AA257-C0002 B 27 27 03
VALVE CLOSE LIMIT CLOSE 2 W 0.6/1kV CU/ PVC/PVC/OS 2Cx1.5 W 28 28 W16 W16 04
SWITCH
MIXED BED POLISHER
COM 1 W1 W1 29 29 05
A
00GCF31AA258-C0001
XV-00GCF31AA258 OPEN 2 W2 W2 30 30 W17 W17 06
0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
VALVE LIMIT SWITCH
CLOSE 3 W3 31 31 07
00GCF31AA258
2C SP W3 32 32 W18 W18 08
MIXED BED POLISHER TB45
COM 1 W1 W1 33 33 09
A
00GCF31AA259-C0001
XV-00GCF31AA259 OPEN 2 W2 W2 34 34 W19 W19 10
0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
VALVE LIMIT SWITCH
CLOSE 3 W3 35 35 11
00GCF31AA259
2C SP W3 36 36 W20 W20 12
MIXED BED POLISHER
COM 1 W1 W1 37 37 13
A
00GCF31AA260-C0001
XV-00GCF31AA260 OPEN 2 W2 W2 38 38 W21 W21 14
0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
VALVE LIMIT SWITCH
CLOSE 3 W3 39 39 15
00GCF31AA260
2C SP W3 40 40 W22 W22 16
2C SP 2C SP
SHIELD SG SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
00GCY00GH001
PLC PANEL
23 23 07 PLC PANEL
FIELD
SHIELD SG SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
00GCY00GH001
0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
PLC PANEL
VALVE LIMIT SWITCH
CLOSE 3 W3 23 23 15 PLC PANEL
00GCF32AA260
FIELD
SHIELD SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
01 W1 00GCY30GH005-L0001 W1 09
PTB01 SOLENOID VALVE
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 10 PTB05 PANEL
(AUX. POWER)
SHIELD SG
01 W1 00GCY30GH005-C0001 W1 09
PTB02 SOLENOID VALVE
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 10 PTB06 PANEL
(VALVE POWER.)
SHIELD SG
01 W1 W1 37 00GCB21AA251
02 W2 W2 38 OPEN COMMAND
03 W3 W3 39 00GCB21AA252
04 W4 W4 40 OPEN COMMAND
05 W5 W5 41 00GCB22AA251
06 W6 W6 42 OPEN COMMAND
07 W7 W7 43 00GCB22AA252
08 W8 W8 44 OPEN COMMAND
09 W9 W9 45 00GCB31AA251
00GCY00GH001
PLC PANEL
15 W15 W15 51 00GCB80AA252
FIELD
SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
01 W1 W1 57 00GCF11AA251
02 W2 W2 58 OPEN COMMAND
03 W3 W3 59 00GCF12AA251
04 W4 W4 60 OPEN COMMAND
TB76
05 W5 W5 61 00GCF23AA251
06 W6 W6 62 OPEN COMMAND
07 W7 W7 63 00GCF23AA252
08 W8 W8 64 OPEN COMMAND
09 W9 W9 01 00GCF13AA251
10 W10 W10 02 OPEN COMMAND
00GCY30GH005-C0003
TB04
11 W11 0.6/1kV CU/ PVC/PVC/OS 20Cx1.5 W11 03 00GCF13AA252
12 W12 W12 04 OPEN COMMAND
17 W17 W17 09
TB SPARE
00GCY00GH001
PLC PANEL
FIELD
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
00GCY00GH001
LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
PLC PANEL
00GCB32AA251 CLOSE 3 W3 23 23 23 PLC PANEL
FIELD
SHIELD SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
00GCY00GH001
0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
PLC PANEL
00GCF13AA252
CLOSE 3 W3 23 23 31 PLC PANEL
FIELD
SHIELD SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
01 W1 00GCY30GH004-L0001 W1 07
PTB01 SOLENOID VALVE
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 08 PTB05 PANEL
(AUX. POWER)
SHIELD SG
03 W1 00GCY30GH004-C0001 W1 07
PTB02 SOLENOID VALVE
04 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 08 PTB06 PANEL
(VALVE POWER.)
SHIELD SG
01 W1 W1 13 00GCN13AA251
02 W2 W2 14 OPEN COMMAND
03 W3 W3 15 00GCN46AA251
04 W4 W4 16 OPEN COMMAND
05 W5 W5 17 00GCN46AA252
06 W6 W6 18 OPEN COMMAND
07 W7 W7 19 00GCN13AA253
08 W8 W8 20 OPEN COMMAND
09 W9 W9 21 00GCN23AA253
00GCY00GH001
PLC PANEL
15 W15 W15 27 00GCN55AA252
FIELD
SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
01 W1 W1 33 00GKD20AA251
02 W2 W2 34 OPEN COMMAND
03 W3 W3 35 00GKD20AA252
04 W4 W4 36 OPEN COMMAND
05 W5 W5 37 00GKD20AA253
06 W6 W6 38 OPEN COMMAND
07 W7 W7 39 00GKD20AA254
08 W8 W8 40 OPEN COMMAND
09 W9 W9 41 00GKD20AA255
10 W10 W10 42 OPEN COMMAND
00GCY30GH004-C0003
TB04 TB77
11 W11 0.6/1kV CU/ PVC/PVC/OS 20Cx1.5 W11 43 SPARE
12 W12 W12 44 OPEN COMMAND
17 W17 W17 49
TB SPARE
00GCY00GH001
PLC PANEL
FIELD
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
00GCY00GH001
LIMIT SWITCH 00GCN23AA251
PLC PANEL
SULFURIC ACID DOSING TANK COM 1 W1 00GCN23AA251-C0002 W1 23 23 07 PLC PANEL
FIELD
SHIELD SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
AC FILTER COM 1 W1 W1 1 1 W1 W1 25
XV-00GKD20AA251 00GKD20AA251-C0001
OPEN 2 W2 W2 2 2 W2 W2 26
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GKD20AA251 CLOSE 3 W3 3 3 27
2C SP W3 4 4 W3 W3 28
TB51
AC FILTER COM 1 W1 W1 5 5 29
XV-00GKD20AA252 00GKD20AA252-C0001
OPEN 2 W2 W2 6 6 W4 W4 30
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GKD20AA252 CLOSE 3 W3 7 7 31
2C SP W3 8 8 W5 W5 32
AC FILTER COM 1 W1 W1 9 9 W6 W6 01
XV-00GKD20AA253 00GKD20AA253-C0001
OPEN 2 W2 W2 10 10 W7 W7 02
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GKD20AA253 CLOSE 3 W3 11 11 03
2C SP W3 12 12 W8 W8 04
AC FILTER COM 1 W1 W1 13 13 05
XV-00GKD20AA254 00GKD20AA254-C0001
OPEN 2 W2 W2 14 14 W9 W9 06
VALVE LIMIT SWITCH 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
00GKD20AA254 CLOSE 3 W3 15 15 07
2C SP W3 16 16 W10 W10 08
AC FILTER COM 1 W1 W1 17 17 09
00GCY00GH001
PLC PANEL
23 23 15 PLC PANEL
FIELD
SHIELD SG SHIELD SG
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
1 W1 00GCY30GH001-C0001 W1 11
PTB01
2 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 12 SOLENOID VALVE
PTB06 PANEL
SULFURIC ACID DOSING TANK + W1 W1 1 SHIELD SG
00GCN23AA252-C0001 (VALVE POWER.)
FOR CLARIFIER FOR WT INLET VLAVE
00GCN23AA252 (SOLENOID V/V) - W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 2
SHIELD PG
TB01
CAUSTIC DOSING TANK FOR CALARIFIER + W1 W1 3 1 W1 W1 53
00GCN13AA252-C0001 00GCY30GH001-C0002 00GCN23AA252
FOR WT INLET VALVE
- W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 4 2 W2 0.6/1kV CU/ PVC/PVC/OS 8Cx1.5 W2 54 OPEN COMMAND
00GCN13AA252 (SOLENOID V/V)
TB77
SHIELD PG 3 W3 W3 55 00GCN13AA252
4 W4 W4 56 OPEN COMMAND
TB02
4C SP
SHIELD SG
00GCY00GH001
PLC PANEL
FIELD
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
01 W1 W1 15 SOLENOID VALVE
00GNY30GH001-C0001
PTB01 PANEL
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 16 (VALVE POWER.)
PTB06
TO WASTEWATER STORAGE POND + W1 W1 1 SHIELD SG
00GNK53AA251-C0001
INLET VALVE 00GNK53AA251
- W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 2
(SOLENOID V/V)
SHIELD PG
TB01
TO PURIFIED WASTEWATER PIT + W1 W1 3 1 W1 W1 61
00GNK53AA252-C0001 00GNK53AA251
INLET VALVE 00GNK53AA252
- W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 4 2 W2 W2 62 OPEN COMMAND
(SOLENOID V/V) 00GNY30GH001-C0002
TB77
SHIELD PG TB02 3 W3 0.6/1kV CU/ PVC/PVC/OS 5Cx1.5 W3 63 00GNK53AA251
4 W4 W4 64 OPEN COMMAND
1C SP 1C SP
SHIELD SG
00GCY00GH001
PLC PANEL
FIELD
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
1 W1 W1 13 SOLENOID VALVE
00GCY30GH002-C0001
PTB01 PTB06 PANEL
2 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 14 (VALVE POWER.)
SHIELD SG
SHIELD PG SHIELD SG
00GCY00GH001
PLC PANEL
FIELD
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
01 W1 00GRC20GH002-L0001 W1 11
PTB01 SOLENOID VALVE
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 12 PTB05 PANEL
(AUX. POWER)
SHIELD SG
01 W1 00GRC20GH002-C0001 W1 17
PTB02 SOLENOID VALVE
02 W2 0.6/1kV CU/ PVC/PVC/OS 2Cx2.5 W2 18 PTB06 PANEL
(VALVE POWER.)
SHIELD SG
01 W1 W1 05 00GRC23AA251
02 W2 W2 06 OPEN COMMAND
00GRC20GH002-C0002
03 W3 W3 07 TB78 00GRC23AA252
0.6/1kV CU/ PVC/PVC/OS 5Cx1.5
04 W4 W4 08 OPEN COMMAND
TB02
05 W5 W5 SPARE
06 SPARE SHIELD SG
07 SPARE
08 SPARE
00GCY00GH001
PLC PANEL
FIELD
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
SPARE 11 11
SPARE 12 12 W7 W7
SPARE 13 13 SPARE
SPARE 14 14 W8 W8
SPARE 15 15
SPARE 16 16 W9 W9
1C SP 1C SP
00GCY00GH001
PLC PANEL
FIELD
[NOTE]
END END
FIELD SOLENOID VALVE PANEL
CONTINUED CONTINUED
B1 B1 13
DEMI WTR STOR TK #1 LVL
W1 OUT OF SCOPE W1 14
00GHC10CL101
by HEC 15
TB94
B2 B2 16
DEMI WTR STOR TK #2 LVL
W2 W2 17
00GHC20CL101
18
B3 B3 13
POTW STOR TK LVL
W3 W3 14
DCS 00GKB10CL101
DCS ANALOG SIGNAL 15 PLC PANEL
(OUT OF SCOPE) B4 B4 16 00GCY00GH001
CLG TWR MKUP PP SUCT LVL
W4 W4 17
00GBL10CL101
18
TB99
B5 B5 19
RAW WTR STOR TK #1 LVL
W5 W5 20
00GAD10CL101
21
B6 B6 22
RAW WTR STOR TK #2 LVL
W6 W6 23
00GAD20CL101
SHIELD 24
O'SHIELD
[NOTE]
END
FIELD
CONTINUED
COM W1 W1 01
WT SYS REM SEL W2 OUT OF SCOPE W2 02
COM W3 by HEC W3 03
WT SYS RDY W4 W4 04
COM W5 W5 05
WT SYS RUN W6 W6 06
COM W7 W7 07
WT SYS STOPPED W8 W8 08
COM W9 W9 09
WT SYS COM FLT W10 W10 10
COM W11 W11 11
WT SYS PLC FLT W12 W12 12
COM W13 W13 13
WWT SYS REM SEL W14 W14 14
COM W15 W15 15
WWT SYS RDY W16 W16 16
COM W17 W17 17
WWT SYS RUN W18 W18 18
COM W19 W19 19
DCS WWT SYS STOPPED W20 W20 20
(PLC TO DCS PLC PANEL
O'SHIELD SG
[NOTE]
END
FIELD
CONTINUED
COM W1 W1 01
WT SYS GP START CMD W2 W2 02
COM W3 W3 03
WT SYS GP STOP CMD W4 W4 04
COM W5 W5 05
WWT SYS GP START CMD W6 W6 06
COM W7 W7 07
WWT SYS GP STOP CMD W8 W8 08
COM W9 W9 09
DCS
(DCS TO PLC SWT SYS GP START CMD W10 OUT OF SCOPE W10 10 PLC PANEL
TB34
COMMAND COM W11 by HEC W11 11 00GCY00GH001
SWT SYS GP STOP CMD W12 W12 12
COM W13 W13 13
ANY RAW WTR INTK PP RUN W14 W14 14
W15 6C SP
W16
W17
W18
W19
W20
[NOTE]
END
FIELD
CONTINUED
A R R A
HOT WATER TK OUT TEMP SENSOR 00GCP20CT102-X0002 HOT WATER TK OUT TEMP
B B B B
(00GCP20CT102) 0.6/1kV CU/PVC/PVC/OS 1T x 1.5SQ (00GCP20CT102)
b W W b
A R R A
EFFLUENT PP DISCH TEMP SENSOR 00GNK53CT101-X0002 EFFLUENT PP DISCH TEMP
B B B B
(00GNK53CT101) 0.6/1kV CU/PVC/PVC/OS 1T x 1.5SQ (00GNK53CT101)
b W W b
FIELD
FIELD
[NOTE]
END
FIELD
CONTINUED
00GCY00OWS-C0001
OWS-1 RJ-45 RJ-45 HUB-A
UTP
PLC PANEL
00GCY00GH001
00GCY00OWS-C0002
OWS-1 RJ-45 RJ-45 HUB-B
UTP
00GCY00EWS-C0001
OWS-2 / EWS RJ-45 RJ-45 HUB-A
UTP
PLC PANEL
00GCY00GH001
00GCY00EWS-C0002
OWS-2 / EWS RJ-45 RJ-45 HUB-B
UTP