Name : Sanower Rehman

Process Integration and Energy Optimization Assignment 5:


Solution:

There are total 10 streams in this problem, I follow following steps for finding hot & cold utility by
using PTA (Problem Table Algorithm) method:

1. Data extraction from flow diagram.


2. Adjust the temperature by using dTmin
3. Perform a heat balance in each interval.
4. Cascade the heat surplus/deficit through the intervals.
5. In the last, I added heat so that no deficit is cascaded.

Step: 1 Data Extraction:

Data Extraction
S.No Path Stream mass flow rate cp m*cp Tsupply Ttarget
1 C1 36 4,19 150,84 25 100
2 0-2 Water C2 36 2260 81360 100 100,001
3 C3 36 1,90 68,40 100 800
0-1
4 Methane C4 16 3,750 60,000 150 800
5 3_4 C5 52 5,490189 285,490 800 800,001
6 4_5 H1 52 3,076923 160,000 800 350
7 C6 72 40,952 2946,660 25 100
8 0_6 C7 72 100 100,001
9 C8 72 8,94 1108,000 100 350
10 8_9 H2 124 6,837 852,307 350 25