Professional Documents
Culture Documents
2 - Transfer Pump Design Calculation 1
2 - Transfer Pump Design Calculation 1
ENGINEERING CONSULTANCY
Designed By : RSA Checked By : RSA
Subject : PUMP DESIGN CALCULATION
Date : 07-21-18 Date : 07-21-18
DAILY FLOWRATE :
= 28,620.00 GALLONS
= 108.33 cu. M
II. DAILY VOLUMETRIC FLOWRATE DEMAND 108.33 cu. M say 100.00 cu. M
III. HOURLY PEAK VOL. FLOWRATE 30.00 cu. M / Hr say 30.00 cu. M / Hr
~ 132.09 GPM
Hor. Run 30 M
TRANSFER PUMP MOTOR :
Res. Pressure 20 PSI
14.08 M TPm = 9.56 HP (Approx. @ 60% Efficiency)
174.43 FT
P @ 76 PSI
NOTE:
Motor rating must be validated to the pump manufacturer.