measuring

Totalising, Dosing and •

Monitoring Electronics monitoring



pulse input analysing

ZOK

 LCD-display, background lighting


 2 pulse inputs
2" pipe mounting kit (NPN, PNP, NAMUR, reed switch etc.)
 
Analogue, switching, pulse, relay output,
status output

P?
Z2
 Sensor supply
 Free scaling
 
Universal housing, panel mounting or
field housing

Wall mounting kit

KOBOLD companies worldwide: KOBOLD Messring GmbH


Nordring 22-24
AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, FRANCE, GERMANY, D-65719 Hofheim/Ts.
GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, Head Office:
PERU, POLAND, Republic of Korea, RUSSIA, SPAIN, SWITZERLAND, THAILAND, TUNISIA, +49(0)6192 299-0
+49(0)6192 23398
turkey, USA, VIETNAM info.de@kobold.com
1/04 - 2023

www.kobold.com

1
Totalising, Dosing and Monitoring Electronics Model ZOK

Technical Details
External power supply: 5 ... 28 VDC (without using the
analogue output)
8 ... 28 VDC (with using the
analogue output)
12 ... 28 VDC with relay output
max. power consumption:
with DC supply voltage approx.
70 mA (with full
backlight, without outputs)
Ex versions: Ui = 28 V
Ii = 100 mA
Pi = 0.7 W
See table on page 7 for details
Description Battery (battery for
The electronic units ZOK-Xx are specifically designed for operation): 3.6 V / 2200 mAh
the calculation, display and transfer of calculations and Lithium size AA
flow rates of flow meters with pulse or frequency outputs. Battery life in battery mode: dependant on the chosen sleep
The instruments display flow rate, day counter (resettable) mode
and total counter in the operator-selected units. A clear max. 17 months
multilingual menu guides you through the programming of min. 3 months
the device that largely eliminates the requirement of constant Display: LCD, graphic 128 x 64,
usage of operating manual. All user-specific program settings backlight adjustable (only with
are retained even when changing the battery. external supply)
The electronics options ZOK-ZxK are weather resistant Size of main display value: 12.5 mm
and adequately reflect IP66 / 67 (NEMA 4X). The electronics
Display resolution of main
is housed in a UV-resistant, glass-filled nylon housing with
display value: 5 digits, based on measuring
stainless steel screws and FPM seals.
range end value
The option ZOK-ZxP is in a panel housing 96x96 mm with Engineering units
protection class IP44. The option ZOK-ZxF is available in displayed: litres, millilitres, gallons (US or
powder coated aluminum extruded housing with plastic lids
UK), barrel, m3, user defined
and appropriate protection class IP 66/67. The instruments
engineering units displayed
are suitable for harsh indoor or outdoor environments and
comply with EU Directive 2004/108/EC (Electromagnetic Input scaling range: 0.001 ... 99,999.999 with
Compatibility). 3 floating decimal points
Mounting: meter mount, wall, surface, pipe
Significant Characteristics or panel mount, field mount
 Battery life or external powered, graphic LCD-display Measuring inputs: 2 x pulse input, type: NPN,
resettable and cumulative totaliser, 5 digit main value PNP, NAMUR, Reed, Hall, acti-
display, configurable ve (configurable with software)
 Robust field or panel mountable housing Input frequency: 0.1 ...  1000 Hz,
 Simple programming High-Low-threshold 1 VDC,
max. Input amplitude 30 VDC
 Universal pulse inputs
Direction Detection
 Display backlighting with Quadratue Signal: Phase angle ±5° to ±65°
 Status output Basic accuracy of flow
 Scalable pulse output measurement: < 0.1 % of reading
 Optional: wall or pipe mounting (the accuracy of the displayed
value depends on the adjusted
scale and display resolution)
Sensor supply: 8 VDC, max. 30 mA
(with external supply > 10 VDC)
Arithmetic functions: A + B, A - B with scalable ana-
logue output
1/04 - 2023

2 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Outputs Relay outputs: potential-free changeover


Status output: transistor output, Push-Pull contacts, max. switching
(PP), max. 300 mA, voltage 230 VAC/DC,
overload protection max. current load dependent
Relay outputs (only -Z2): potential-free changeover (see diagram)
contacts, max. switching Analogue output
voltage 230 VAC/DC, max. current (at ZOK-Z5P): 4 - 20 mA, 3-wire,
load dependent (see diagram) current source
Solid-state relay output Housing: ZOK-ZxP panel mounted,
(only E2/E5): max. switching voltage: 30 VDC 96 x 96 mm, depth 60 mm
RON = 1700 Ω, ROFF > 10 GΩ degree of protection front IP 65,
to be used with NAMUR-isola- backside IP 20
ted switching amplifier ZOK-ZxF aluminium housing
Switching outputs: transistor output PNP, NPN or with plastic lid PA6
Push-Pull (PP), with software 117 x 117 mm, depth 127 mm
configurable, Protection: IP 65
max. output current: 300 mA Cable entry: 3 x M16 x 1.5/2 x PG13.5 for
(source / sink), ZOK-ZxF
overload protection 3 x screw terminals for ZOK-ZxP
Pulse output: transistor output, Push-Pull Retention of meter readings
(PP), max. 300 mA, in case of power failure: in integrated, non-volatile
overload protection memory
Analogue output: 4 - 20 mA, 2-conductor loop Ambient temperature: -20 ... +80 °C
operation or 3-wire operation
(current source or sink)
selectable by external wiring,
free scaling,
max. load: 750 Ω at 24 VDC, Max. DC load breaking capacity
250 Ω at 14 VDC,
150 Ω at 12 VDC,
Resolution: 16 bits
Operation: 4 buttons
Housing: plastic, PA 6, GF-enhanced
Protection: IP 66/67 (not for panel
mounting)
Cable entry: 3 x M 20 x 1.5 or ½" NPT
(prepared, not for panel
mounting device)
Electrical connection: plug-in terminals
ATEX Certification: II 2G Ex ia IIC T4 Gb
IECEx Certification: Ex ia IIC T4 Gb
Ambient temperature: ZOK-Z: -20 ... +80 °C
ZOK-E: -20 … +60 °C

Additional Data for Options ZOK-ZxP and ZOK-ZxF


Power supply: 12 ... 28 VDC (supply option -6)
90 - 260 VAC (supply option -0)
battery operation only with
ZOK-ZxF with supply option 3
See table on page 7 for details
Sensor supply: 8 V with supply voltage ≥8,5 VDC
(supply option -3)
8 V or 24 V selectable (supply
option -0 and 6). Max 30 mA.
1/04 - 2023

No responsibility taken for errors; www.kobold.com 3


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Instrument / Functions overview ZOK...

Function Z1P/Z1F Z1K/M/0 Z2P/Z2F Z2K/M/0 Z5P/Z5F Z3K/M/0/F Z5K/M/0 E1K/M E2K/M/0 E3K/M/0 E5K/M/0

Dual counter X X X X X X X X
Dosing function X X X
Controller function X X X X X

Certification

ATEX/IECEx
X X X X
Certification

Power supply

DC-supply X X X X X X X X X X X
AC-supply X X X
Battery operation
(output X X X X
deactivated)2)
Battery included in
X X X X
shipment 3)

Sensor supply (only with external power supply)

8 V/ 8 V/ 8 V/
Sensor supply 8V 8V 8V 8V 8V 8V 8V 8V
24 V 24 V 24 V

Electrical outputs (only with external supply)

with solid- with solid-


state state
Relay outputs X X X X
relay relay
board 1) board 1)
Status outputs X X X X X X X
2L/ 2L/
Analogue outputs 3L 3L 3L
3L 3L
with solid-
state
Pulse outputs X X X
relay
board 1)

LCD-display

Selectable units X X X X X X X X X X X

Decimal point X X X X X X X X X X X

Accumulative total X X X X X X X X X X X

Resettable total X X X X X X X X X X X

Linearisation X X X X X X X X X

Rate display X X X X X X X X X X X

Backlighting X X X X X X X

Arithmetic functions X X X X X X X X X

1)
Solid-state relay board serves as a galvanic separation to be used in hazardous area
2)
Battery operation only applicable with a passive sensor (e.g. reed switch)
3)
Shipment without battery with option N.
1/04 - 2023

4 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Display
Display layout in measuring mode single channel (ZOK-Z1/E1/Z3/E3/E5)

part- or total volume display input A

part- or total volume counter input A

unit associated to main display

volume flow display input A

part- or total volume counter input A

unit associated to main display


1/04 - 2023

No responsibility taken for errors; www.kobold.com 5


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Display (continued) supply type (ext / bat) status output


Display layout in measuring
mode for dual channel
(ZOK-Z1/E1/Z3/E3/E5)
part volume display input A

part volume display input B

volume flow display inputs A and B


(alternating)

unit associated to main display


over- and underrun display input B
over- and underrun display input A
status and type input B
status and type input A

supply type (ext / bat)


status switch outputs
status pulse output
status output

volume flow display input A

volume flow display input B

part- or total volume counter inputs A and B


(alternating)

unit associated to main display


over- and underrun display input B
over- and underrun display input A
status and type input B
status and type input A

ZOK-Z2 / E2 (Dosing unit) supply type (ext)


status switch outputs
status output

over- and underrun display


input A dosing volume display

batch counter
volume flow display

start dosing
reset dosing volume
set dosing volume
status and input type A
1/04 - 2023

6 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Order Details (Example: ZOK-Z1 K M F 3 0 0)


Electrical
Model Electronics Housing type connection/ Input Power supply Options Special
cable gland

0 = universal mount
Z1 = dual totaliser LCD
(standard,
Z2 = dosing unit LCD
2)
round plastic
Z3 = rate totaliser LCD, without holder
4-20 mA plates/without
Z5 = as Z3 with 2 relays holes) M3) = 3 x M 20 x 1.5 0 = without 0 = without
E1 = as Z1 with ATEX/ cable entry Y = special
K = universal mount R = 2 relays
2)
IECEx approval (please
(standard, 23) = 3 x ½" NPT 32) = 5 ... 28 VDC, G = 2 x solid-
7)
E22) = as Z2 with ATEX/ round plastic F = pulse/ battery specify
IECEx approval cable entry state
ZOK- with holder frequency 2) in clear
E3 = as Z3 with ATEX/ K = terminal on
9) 0 = 90 ... 260 VAC relays
plates) input text)
IECEx approval the back 62) = 12 ... 28 VDC, P = 3 x solid- N = Shipment
8)

4-20 mA, without M = 


universal mount N4) = 3 x M16 x 1.5 state
pulse- and (round plastic without
cable entry relays battery
switching outputs for retro­fitting
E56) = as E3 with DON)
4-20 mA and P1) = panel mount
pulse- and 96 x 96
switching outputs
F1) = field housing

1)
Not for ZOK-E1, E2, E3 and E5 2) See table below 3) Only for housing ZOK-xxK, ZOK-xxM, ZOK-xx0 5) In preparation
6)
Option E5 possible only with remote I.S.isolator 7) Standard for ZOK-E2 8) Standard for ZOK-E5 9) For ZOK-ZxP

Overview of electrical options and corresponding housings


Model Electronics Housing Supply voltage Relay option solid-state
Option Battery option relays

0/K/M 3 standard
P 6/0 no
Z1 no
yes (with voltage
F 3/0
option 3)
0/K/M 6
Z2 P no standard
6/0 no
ZOK F
Z3 0/K/M/F 3 yes no
0/K/M 6 no standard
Z5 P 6/0 no standard
F 6/0 no standard
E1/E3 1)
K/M 3 standard
no
E2/E51) K/M 3 no standard
1)
Without backlighting

Accessories

Description Model

Stainless steel wall mounting kit ERS-ZOK-023618

Stainless steel 2" pipe mounting kit ERS-ZOK-003402

Cooling fin for high temperature flowmeter ERS-ZOK-023619

Batterypack ATEX/IECEx, 3,6 V ERS-BATEX036

ERS-BATEX036 is part of standard scope of delivery of ZOK-E1/E3


(Shipment without battery with option N)
1/04 - 2023

No responsibility taken for errors; www.kobold.com 7


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Dimensions [mm]

ZOK-ExK /-ZxK

21,6

61 22
ZOK-ExM /-ZxM
21,6
21.6
52 21,6

134
32

66

61 131 61 22

21,6
52
ZOK-ZxP
7 56
32

66
96,4
96.4 61

96,4
96.4 56,4
56.4

ZOK-ZxF

127 117
3xM16x1.5
34
117

91
1/04 - 2023

8 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.