Professional Documents
Culture Documents
Zok GB Accessories
Zok GB Accessories
ZOK
P?
Z2
Sensor supply
Free scaling
Universal housing, panel mounting or
field housing
www.kobold.com
1
Totalising, Dosing and Monitoring Electronics Model ZOK
Technical Details
External power supply: 5 ... 28 VDC (without using the
analogue output)
8 ... 28 VDC (with using the
analogue output)
12 ... 28 VDC with relay output
max. power consumption:
with DC supply voltage approx.
70 mA (with full
backlight, without outputs)
Ex versions: Ui = 28 V
Ii = 100 mA
Pi = 0.7 W
See table on page 7 for details
Description Battery (battery for
The electronic units ZOK-Xx are specifically designed for operation): 3.6 V / 2200 mAh
the calculation, display and transfer of calculations and Lithium size AA
flow rates of flow meters with pulse or frequency outputs. Battery life in battery mode: dependant on the chosen sleep
The instruments display flow rate, day counter (resettable) mode
and total counter in the operator-selected units. A clear max. 17 months
multilingual menu guides you through the programming of min. 3 months
the device that largely eliminates the requirement of constant Display: LCD, graphic 128 x 64,
usage of operating manual. All user-specific program settings backlight adjustable (only with
are retained even when changing the battery. external supply)
The electronics options ZOK-ZxK are weather resistant Size of main display value: 12.5 mm
and adequately reflect IP66 / 67 (NEMA 4X). The electronics
Display resolution of main
is housed in a UV-resistant, glass-filled nylon housing with
display value: 5 digits, based on measuring
stainless steel screws and FPM seals.
range end value
The option ZOK-ZxP is in a panel housing 96x96 mm with Engineering units
protection class IP44. The option ZOK-ZxF is available in displayed: litres, millilitres, gallons (US or
powder coated aluminum extruded housing with plastic lids
UK), barrel, m3, user defined
and appropriate protection class IP 66/67. The instruments
engineering units displayed
are suitable for harsh indoor or outdoor environments and
comply with EU Directive 2004/108/EC (Electromagnetic Input scaling range: 0.001 ... 99,999.999 with
Compatibility). 3 floating decimal points
Mounting: meter mount, wall, surface, pipe
Significant Characteristics or panel mount, field mount
Battery life or external powered, graphic LCD-display Measuring inputs: 2 x pulse input, type: NPN,
resettable and cumulative totaliser, 5 digit main value PNP, NAMUR, Reed, Hall, acti-
display, configurable ve (configurable with software)
Robust field or panel mountable housing Input frequency: 0.1 ... 1000 Hz,
Simple programming High-Low-threshold 1 VDC,
max. Input amplitude 30 VDC
Universal pulse inputs
Direction Detection
Display backlighting with Quadratue Signal: Phase angle ±5° to ±65°
Status output Basic accuracy of flow
Scalable pulse output measurement: < 0.1 % of reading
Optional: wall or pipe mounting (the accuracy of the displayed
value depends on the adjusted
scale and display resolution)
Sensor supply: 8 VDC, max. 30 mA
(with external supply > 10 VDC)
Arithmetic functions: A + B, A - B with scalable ana-
logue output
1/04 - 2023
Function Z1P/Z1F Z1K/M/0 Z2P/Z2F Z2K/M/0 Z5P/Z5F Z3K/M/0/F Z5K/M/0 E1K/M E2K/M/0 E3K/M/0 E5K/M/0
Dual counter X X X X X X X X
Dosing function X X X
Controller function X X X X X
Certification
ATEX/IECEx
X X X X
Certification
Power supply
DC-supply X X X X X X X X X X X
AC-supply X X X
Battery operation
(output X X X X
deactivated)2)
Battery included in
X X X X
shipment 3)
8 V/ 8 V/ 8 V/
Sensor supply 8V 8V 8V 8V 8V 8V 8V 8V
24 V 24 V 24 V
LCD-display
Selectable units X X X X X X X X X X X
Decimal point X X X X X X X X X X X
Accumulative total X X X X X X X X X X X
Resettable total X X X X X X X X X X X
Linearisation X X X X X X X X X
Rate display X X X X X X X X X X X
Backlighting X X X X X X X
Arithmetic functions X X X X X X X X X
1)
Solid-state relay board serves as a galvanic separation to be used in hazardous area
2)
Battery operation only applicable with a passive sensor (e.g. reed switch)
3)
Shipment without battery with option N.
1/04 - 2023
Display
Display layout in measuring mode single channel (ZOK-Z1/E1/Z3/E3/E5)
batch counter
volume flow display
start dosing
reset dosing volume
set dosing volume
status and input type A
1/04 - 2023
0 = universal mount
Z1 = dual totaliser LCD
(standard,
Z2 = dosing unit LCD
2)
round plastic
Z3 = rate totaliser LCD, without holder
4-20 mA plates/without
Z5 = as Z3 with 2 relays holes) M3) = 3 x M 20 x 1.5 0 = without 0 = without
E1 = as Z1 with ATEX/ cable entry Y = special
K = universal mount R = 2 relays
2)
IECEx approval (please
(standard, 23) = 3 x ½" NPT 32) = 5 ... 28 VDC, G = 2 x solid-
7)
E22) = as Z2 with ATEX/ round plastic F = pulse/ battery specify
IECEx approval cable entry state
ZOK- with holder frequency 2) in clear
E3 = as Z3 with ATEX/ K = terminal on
9) 0 = 90 ... 260 VAC relays
plates) input text)
IECEx approval the back 62) = 12 ... 28 VDC, P = 3 x solid- N = Shipment
8)
1)
Not for ZOK-E1, E2, E3 and E5 2) See table below 3) Only for housing ZOK-xxK, ZOK-xxM, ZOK-xx0 5) In preparation
6)
Option E5 possible only with remote I.S.isolator 7) Standard for ZOK-E2 8) Standard for ZOK-E5 9) For ZOK-ZxP
0/K/M 3 standard
P 6/0 no
Z1 no
yes (with voltage
F 3/0
option 3)
0/K/M 6
Z2 P no standard
6/0 no
ZOK F
Z3 0/K/M/F 3 yes no
0/K/M 6 no standard
Z5 P 6/0 no standard
F 6/0 no standard
E1/E3 1)
K/M 3 standard
no
E2/E51) K/M 3 no standard
1)
Without backlighting
Accessories
Description Model
Dimensions [mm]
ZOK-ExK /-ZxK
21,6
61 22
ZOK-ExM /-ZxM
21,6
21.6
52 21,6
134
32
66
61 131 61 22
21,6
52
ZOK-ZxP
7 56
32
66
96,4
96.4 61
96,4
96.4 56,4
56.4
ZOK-ZxF
127 117
3xM16x1.5
34
117
91
1/04 - 2023