Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

IJE TRANSACTIONS C: Aspects Vol. 29, No.

3, (March2016) 288-296

International Journal of Engineering


Journal Homepage: www.ije.ir

Experimental Investigation of Flooding and Drop Size in a Kuhni Extraction Column


A.R. Shirvani,a A. Ghaemi * a, M. Torab-Mostaedi b
a Department of Chemical Engineering, Iran University of Science and Technology
b Nuclear Fuel Cycle Research School, Nuclear Science and Technology Research Institute

PAPER INFO A B S T R A C T

Paper history:
Received 18 October 2015
Received in revised form 20February 2016
Accepted 03March 2016

I D
In this work, the hydrodynamic behavior of a Kuhni extraction column has been investigated
experimentally. The experiments were carried out in the absence of mass transfer for two different
standard chemical systems. In the experiments operating variables including agitation speed, flow rate

S
of both liquid phases and interfacial tension have been studied. Sauter-mean drop diameter, flooding
velocity and holdup at flooding have been measured in the Kuhni column. The results showed that
Keywords: Sauter-mean diameter are strongly affected by agitation speed and interfacial tension whereas the

f
Kuhni Column effects of continuous phase and dispersed phase flow rates are negligible. Two rigorous empirical
Flood Point correlations are proposed for predicting flooding velocities and Sauter-mean drop diameterwith mean
Holdup deviation of 5.7% and 7.2%, respectively. The mean drop size correlation is a function of column

o
Sauter-Mean Drop Diameter geometry, operating conditions and physical properties of liquid systems. Good agreement between
predictions and experiments is found for all operating conditions investigated.

e
doi: 10.5829/idosi.ije.2016.29.03c.02

1. INTRODUCTION1

i v shaft used and steps separated by a leaky static plate.


Blades create a vortex flow pattern which is somewhat

h
similar to RDC column [7]. Also, perforated plates used
The liquid-liquid extraction as one of the important between stages make it possible to creating axial flow in
processes of mass and energy exchange with the

c
column but completely separated steps than RDC and
extensive application in the petroleum and MIXCO columns. This topic caused reduction reverse

r
petrochemical industries, nuclear industries, flow especially for the dispersed phase, but collects and
pharmaceutical industries, metallurgy [1-4]. The unlocks the column for cleaning and maintenance
operations consist in separation of one or several makes it more difficult. Kühni columns in the range of

A
components (solute) from a liquid phase mixture by
addition of another non-miscible or partially miscible
liquid phase, in which the solute is preferentially
dissolved. This operation process is often operated in
counter-current contactors [5]. Two immiscible liquid
phases flow counter-currently, one being dispersed into
sizes laboratory scale by 60 mm diameter to industrial
scale by 2 m diameter and with similar applications to
RDC are existence [8].
For the design, optimization and exploitation of
extraction column require both mass transfer and
hydrodynamic parameters, such as holdup, flooding
the other. Each extraction equipment attempts to velocities and drop size distribution. Holdup, flooding
produce larger interfacial area often by applying velocities and drop size, are key parameters in order to
mechanical agitation to better disperse the phase [6]. determine the column capacity and the column diameter
Kühni column is representatives of this type of [9]. Knowledge of drop size and distribution are
equipment. In this column, worn blades on a central necessary parameters for measuring mass transfer
coefficients [10]. It influences the dispersed phase
holdup and residence time and the maximum capacity of
*Corresponding Author’s Email: aghaemi@iust.ac.ir (A. Ghaemi) the column [9, 11]. Thus, for the purpose of establishing

Please cite this article as:A.R. Shirvani, A. Ghaemi, M. Torab-Mostaedi,Experimental Investigation of Flooding and Drop Size in a Kuhni
Extraction Column, International Journal of Engineering (IJE), TRANSACTIONS C: Aspects Vol. 29, No. 3, (March 2016) 288-296

www.SID.ir
289 A.R. Shirvani et al./ IJE TRANSACTIONS C: Aspects Vol. 28, No. 3, (March 2015) 288-296

suitable design procedures for Kühni columns, there is a TABLE 1. Technical parameters of Kuhni extraction column.
need for valid correlations which estimate Sauter-mean
Parameter Value Parameter Value
drop diameter and flooding conditions.
Column diameter (m) 0.117 Settler diameter(m) 0.1775
In this work, the hydrodynamic behavior of a Kühni
column was investigated by measuring the Sauter-mean Active volume of the
Tray number 10 0.0075
column(m3)
drop diameter and flood point characteristics using two
Number of holes 27 Impeller diameter (m) 0.05
different liquid systems. The effects of operating
Tray perforation
variables on mean drop size and flood point are 0.0075 Plate thickness(m) 0.002
diameter (m)
examined. In addition, experiential correlations for
Column height(m) 0.7 Compartment height(m) 0.055
mean drop size and flooding velocities as a function of
operating conditions, physical properties of the liquid
systems and column geometry were proposed.
TABLE 2. Physical properties of liquid systems
Physical property Toluene–water n-Butyl acetate–water
2. EXPERIMENTS

D
ρc (kg/m )
3
998.2 997.6

I
ρd(kg/m )
3
865.2 880.9
2.1. Description of Experimental Setup A pilot
scale Kühni extraction column with ten stages that made µc (m Pas) 0.963 1.027

S
of 2 mm perforated stainless steel sheet was used in the µd (m Pas) 0.584 0.734
experiments. The active part of the column consisted of
σ(mNm )-1
36.0 14.1
a 0.75 m long glass tube with 0.117 m internal diameter.
Two settlers with 0.1775 m diameter were employed at
both ends of the column to separate the two liquid
phases. There are two pumps, one for the dispersed
phase and one for the continuous phase. The interface
level was controlled automatically by an optical sensor.
o f
2. 2. Liquid–Liquid Systems Two liquid-liquid
system to cover a wide range of interfacial tension
values were chosen according to the recommendations
A solenoid valve was provided at the outlet stream of

v
the heavy phase. This valve received electronic signals
from the sensor. When the interface location was going
e of the European Federation of Chemical Engineering
[12]. The liquid–liquid systems that studied were
toluene–water (high interfacial tension), n-butyl

h
leave the column by opening the diaphragm of the
i
to change, the optical sensor sent a signal to the
solenoid valve and the aqueous phase was allowed to

solenoid valve. The organic phase was allowed to leave


acetate–water (medium interfacial tension). The
technical grade, solvents at least 99.5 wt % purity were
used as the dispersed phase. All experiments were
carried out at the 20±2 C. The physical properties of the

c
the column via overflow. Other geometrical liquid–liquid systems used in the experiments are shown
in Table 2.

r
characteristics of the column are presented in Table 1.
The schematic diagram of Kuhni extraction column is
shown in Figure 1.

A
3. FLOOD POINT AND HOLDUP MEASUREMENTS

In the design of an extraction column, the


hydrodynamic parameters including holdup and
flooding velocities are key parameters in order to
determine the column capacity and the column diameter
required. The Number of correlations to predict flooding
velocities in different columns is presented in Table 3. It
shows that flooding velocity correlations are presented
as a function of operating conditions, physical
properties of the liquid systems and column geometry
are proposed [13-15].
In present work, every liquid phase was first
saturated with the other as this is specially necessary
when the organic phase and aqueous phase have
significant reciprocal solubility, and the impeller speed
Figure 1. A schematic diagram of the Kuhni column were equaled to the desired values.

www.SID.ir
A.R. Shirvani et al. / IJE TRANSACTIONS C: Aspects Vol. 29, No. 3, (March 2016) 288-296 290

TABLE 3. Number of correlations to predict flooding in different columns


Extraction column type Correlation Reference

V 0.5
c  Vd0.5  ρc  Δρ 
 0.5303e0.05 
0.256
 μ d2 d T g 
0.051
 a 3μ c2 
0.252
 γρc 
0283
 Afρc 
0.11

Pulsed packed   2     2    [14]


aμ c  ρc   γ   gΔρ   μc a   aμ c 

V 0.5
c  Vd0.5  ρc  Δρ 
 0.5303e0.05 
0.256
 μ d2 d T g 
0.051
 a 3μ c2 
0.252
 γρc 
0283
 Afρc 
0.11

Pulsed packed   2     2    [14]


aμ c  ρc   γ   gΔρ   μc a   aμ c 

 Vcf  Vdf  µc
0.484 1.407 0.17 13.07
 Δρ   d a ρc   Ψµ5c   dc 
1  R 
0.283
Pulsed disc and doughnut  10.80*103    2   4    [15]
  ρc   µc   ρc Ψ   da 
0.124 0.336
 Af 4 c    
Vdf  2.11*103  1  R 
0.511
Pulsed disc and doughnut    [13]
 g   c 

Hanson Mixer-Settler
Vdf c0.25
g 0.25
 0.25
 g 
 1.48  2 
 N D
0.23
 Δ 
 
 c 
0.40
 d 
 
 c 
0.20

1  L 
0.32

I D [13]

The continuous phase was first set at the desired


flow rate. The dispersed phase was then slowly entered,
and its flow rate was slowly increased until the flooding
S
experimental condition. For elliptical drops, both the

f
minor and major axes, d1 and d2, were measured and the
equivalent diameter, de, calculated from the following
point, as revealed by the first appearance of a thin layer
of the dispersed phase under the each step or by the
rejection of the dispersed phase in the form of a dense
layer of small droplets, was reached. The reliability of

e o equation:

de   d12 d 2  3
1
(1)

v
flooding rates was within ±5 %. When the flooding After the determination of the drop sizes, the Sauter-
happened, input and output of the column were shut mean drop diameter, d32, was calculated at experimental
down suddenly and allowed to the dispersed phase to go
to the interface at the top of the column.

h i conditions used as follows:

d32 


n

n
n di3
i 1 i
(2)

c
n d2
i 1 i i

4. DROPLET SIZE MEASUREMENTS

r
where, ni is the number of droplets of mean diameter n i
within a narrow size range i.
According to the importance of droplet size, many

A
researchers studied the effect of column operating
variables on drop size and developed correlations for
predicting the mean drop size [16-24]. Drop size affects 5. NUMERICAL METHODS
almost all the parameters that influence hydrodynamics
and mass transfer in an extraction column [9]. The drop
size developed for different extractors are presented in Numerical solutions including Genetic Algorithms (GA)
Table 4. It shows that drop size depend on column and Particle Swarm Optimization (PSO) were used to
geometry, phases properties and flow rates and agitation obtain optimum values of flooding velocities and drop
speed. In this work, to measure the drop diameter a size correlations parameters. GA is a search method to
photographic technique was used. By taking a digital find an approximate solution optimization problem
photo of the column by a Nikon D3100 digital camera using the concepts of biology such as inheritance and
and comparing the drop dimensions with the known size mutations [25-29]. In this algorithm based on Darwin's
of column as a reference droplet size were obtained. For theory of evolution, the problem variables by using
this comparison two characteristic lengths of the appropriate binary strings are coded. Then, by
internals were used, being the tray thickness and simulation of struggle for survival rules, regularly more
spacing, hc. The recorded photos were analyzed with appropriate disciplines (that in fact, represents the
image processing software to determine the size of the improved solutions) are obtained. Like other
drops. At least 300 drops were analyzed for each optimization techniques, GA is an optimization method

www.SID.ir
291 A.R. Shirvani et al./ IJE TRANSACTIONS C: Aspects Vol. 28, No. 3, (March 2015) 288-296

based on probabilities, namely to ensure obtaining the with evolutionary computation techniques such as GA.
general optimal solution, in any given optimization The system is initialized with a population of random
problem this algorithm is run several times and compare solutions and searches for optima by updating
the results [27-29]. Also, the probability of finding generations. However, unlike GA, PSO has no evolution
global optimum solution by GA is very high. To solve operators such as crossover and mutation. In PSO, the
the minimization problems before applying GA should potential solutions, called particles, fly through the
be convert the problem to a maximization problem [25]. problem space by following the current optimum
The most common way is to define a fitness function, particles [25].
the contrast is a linear combination of the cost function. Each particle keeps track of its coordinates in the
For example, if the goal of the optimization is to find problem space which are associated with the best
the minimum of the function, f(x) and this function will solution (fitness) it has achieved so far (The fitness
return the value of all slopes greater than -1 then it can value is also stored). This value is called pbest. Another
be used to define the fitness function. "best" value that is tracked by the particle swarm
optimizer is the best value, obtained so far by any
1
F ( x) 

D
(3) particle in the neighbors of the particle. This location is
1  f ( x)
called lbest. When a particle takes all the population as

I
PSO is a population based stochastic optimization its topological neighbors, the best value is a global best
technique, inspired by social behavior of bird flocking and is called gbest.

S
or fish schooling [25, 26]. PSO shares many similarities

f
TABLE 4. Number of correlations to predict droplet size in different columns
Extraction column type Correlation Reference

o
0.5 0.23
  g   1  Ф   fAc   c a p    a 2p 
0.5 2
1
Pulsed packed  0.72    6700         [16]
d32    
 Ф   c a p   c    g 
  

e
0.18
 
    g 0.25 
0.14
d 32  1    
0.06   Af 
2
 d   0.23  exp  29.66

v
Pulsed perforated-plate  1.35 0.40
        [17]
   0.25 0.75   w   g  
 w   w w 

i
 g   g 
 w 
1 1
 0.6  1   3d 3 3

h
Stirred Tank d C  0.4 c
( ) [1  C ( ) 2 d 32 ] 5 [18]
32 2  3  
c d

c 1 1 1
d  (1  1.78 ) [  ] 2
 0.5 2   0.6 2

r
Wirz 32 0.4 [19]
[0.98( ) ] [0.27 ( ) ]
 g 
c
d32 d32
 0.0811  4.47  we .06 ,  0.053 1  4.42V i  w0.6e .06

A
Single drop l l [13]
Dl Dl
0.5 C2 C3
       Vd 
Pulsed Packed d32  C1     1   [30]
  g   Af c   Vc 
  Af 
Pulsed packed d  0.33  4.375 exp   [14]
32  0.042 
0.283 0.29 .013
d32  Af 4 c   d a c    c  4 
 33.53*103       2.86 0.085 0.734
    µd   hc 
  g   µc  1  R 
2
Pulsed disc and doughnut  µc  0.34 [15]
     
 g  c   µc   da 
1.14 1.27
   
Hanson Mixer-Settler d  0.23 1  2.24Ф  We0.6  d  d  0197 1  3.04Ф  We0.6  d  [13]
32   32  
 c   c 
0.2304
  af 4 c   c4 g 
0.0514
 Qc 
0.0321

d32  8.26*105    3  1  
 g   Δ   Qd 
 
Pulsed packed 0.239
[30]
  af 4 c   c4 g 
0.0473
 h 
0.1645

d32  7.1*10 
5
  3   
 g   Δ   H0 
 

www.SID.ir
A.R. Shirvani et al. / IJE TRANSACTIONS C: Aspects Vol. 29, No. 3, (March 2016) 288-296 292

The PSO concept consists of, at each time step, up. Although the decrease in Sauter-mean diameter at a
changing the velocity of each particle toward its pbest higher rotor speeds is smooth. Coalescence of droplets at
and lbest locations [25]. Acceleration is weighted by a high rotor speeds is increased by increasing the
random term, with separate random numbers being probability of droplet collision. So, at the high rotor
generated for acceleration toward pbest and lbest speeds, the increased rate of coalescence dominance the
locations. The calculation flowchart is shown in Figure increased sentiment for droplet breakage and the drop
2. size apparently stabilized. Figure 3 also shows that an
increase in the interfacial tension results in an increase in
drop diameter. The effect of dispersed phase velocity on
the mean drop size is shown in Figures 4 and 5. As
6. RESULTS AND DISCUSSION shown in Figure 4, increasing the dispersed phase flow
rate tends to increase the mean drop size. Increasing in
6.1. Sauter-Mean Drop Diameter Agitation speed dispersed phase velocity cause to a larger drop formation
and phase flow rates are the most important parameters diameter and a higher coalescence frequency.
that have effect on droplet size.The effect of agitation
speed on Sauter-mean drop diameter is shown in Figure
3. It shows that smaller drops are observed at higher
rotor speeds, that is a result of increased droplet break-
tension of the system increases.

I D
Figures 6 and 7 also show that the effect of dispersed
phase velocity grows in importance as the interfacial

f S
e o
i v
c h
A r
Figure 2. Calculation flowchart of drop size and flooding point

4 3.5
n-Butylacetate-Water
3.5 3
Toluen-Water
3
2.5
2.5
2
d32(mm)

d32(mm)

2
1.5
1.5
1
1 N=90 rpm
0.5
0.5 N=150 rpm
0
0 0.45 0.55 0.65 0.75 0.85 0.95 1.05
80 130 180 230
N(rpm) Vd(mm/s)

Figure 3. Effect of rotor speed on mean drop size Qd=QC=24 Figure 4. Effect of dispersed phase velocity on mean drop size
lit/hr QC= 24 lit/hr, n-butyl acetate-water

www.SID.ir
293 A.R. Shirvani et al./ IJE TRANSACTIONS C: Aspects Vol. 28, No. 3, (March 2015) 288-296

4 To fit the experimental data and to obtain the parameters


3.5 and minimize the relative absolute error, the following
3 objective function was minimized.
2.5 d exp
32  d32cal 
ARD%  100  (6)
d32(mm)

2 d32exp
1.5
Numerical solutions including GA and PSO were used to
1 N=120 rpm
obtain optimum values of Equation (5) parameters. The
0.5 N=180 rpm
results of this optimization were presented in Table 6.
0
0.4 0.6 0.8 1 1.2
6. 3. Flood PointThe results of flooding and holdup at
Vd(mm/s)
different rotor speeds are shown in Figures 6 to 7. As
Figure 5. Effect of dispersed phase velocity on mean drop
size QC= 24 lit/hr, Toluene-water shown in these figures, with increase in continuous phase
velocity the allowable dispersed phase velocity is

D
decreases. The slip velocity between the phases is
6.2. Prediction of Sauter-mean Drop Diameter One reduced by increasing the continuous phase velocity.
of the main objectives of this study is to propose a new
correlation for prediction of mean drop size. Since a
correlation for the mean drop size, d32, in Kuhni column
is not available, Kumar and Hartland [11] Used Equation
S I
Therefore, the dispersed phase holdup increases with
increase in continuous phase velocity and consequently
the column becomes unstable at lower dispersed phase
velocities. The drop size is decrease with increasing rotor

f
(4) to predict the Sauter-mean drop diameter. This speed, which results in an increasing hold-up such that
correlation is proposed for predicting mean drop size in the critical hold-up is reached at a lower total throughput.

o
Kuhni column. The parameters of this correlation for From Figures 9 and 10, it can be concluded that by
Kuhni column are shown in Table 5. Equation (4) increasing rotor speeds, the maximum throughput of the
reproduces the experimental results with an average column decreases.

e
relative deviation (ARE) of 26.8%.
6.4. Predictive Correlation for Flooding

v
1
d  C en [
1

1
] 2 VelocitiesIn this work an empirical correlation to
32   0.5 2   (4)

i
[C ( ) ] [C  0.4 ( )0.6 ]2 represent the flooding velocities in Kuhni columns was
  g  
c derived. This correlation is mainly based on the
operating variables and the system physical properties.

h
To obtain the sound correlation for predicting the mean
drop size, dimensional analysis with considering an This correlation could be used to predict maximum

c
influencing parameters such as the geometry of column, throughput for existing Kuhni columns
operating conditions and physical properties of liquid n n
   2    n3    4   cg  n5   cN  n6
systems was used. The following equation for the mean
drop size was obtained using the Buckingham theorem.
In order to consider the column geometry effect on

A r
Sauter-mean drop diameter and also to increase the total
number of data points, the experimental results are taken
from Oliveira et al. [31] for water-Exxsol D-80 system.
Vdf  n1  d   c  
  
 
 3  
 c      V c  c   VC   VC 
2 

TABLE 5. Parameters of Equation (4) For Kuhni column[8]


Column No. C C
VC (7)

n3 type of C C n ARD%
 V c  n 2  d N   V d  D cu  4 V d  D im  5
n n data cd dc
d 32  n1   


 
 


 V d   V d   
2  d    d  Kuhni 704 1 3.05 2.49 0.52 0.57 26.8
(5)
n9
  c  n 6  c  n 7   n 8  d g     d 
     
        
 d       dV d   V 3d    V d 

TABLE 6. optimum parameters values of Equation (5)


Num.Method n1 n2 n3 n4 n5 n6 n7 n8 n9 ARD%
GA 2.062 0.234 -1.097 1.579 -0.762 2.257 -2.022 -0.371 0.591 5.70
PSO 2.062 0.234 -1.094 1.579 -0.759 2.257 -2.022 -0.372 0.591 5.70

www.SID.ir
A.R. Shirvani et al. / IJE TRANSACTIONS C: Aspects Vol. 29, No. 3, (March 2016) 288-296 294

7. COMPARISON OF PREVIOUS MODELS WITH


2
THE EXPERIMENTAL RESULTS
1.5 Various correlations for predicting flooding velocities
are available in the literature. The relative absolute
Vdf(mm/s)

1 error, (ARD%) of the calculated values of flooding


velocities obtained by applying the previous correlations
0.5 to the experimental results are listed in Table 8. The
N=150 (rpm) N=180 (rpm) results show that the previous models do not practically
N=210 (rpm) N=240 (rpm) have accurate results. The results show that the
0
presented correlation has good accuracy.
0.45 0.65 0.85 1.05 1.25
Vcf(mm/s)
Figure 6. Experimental variation in Vdfwith Vcf (n-butyl
acetate –Water).
2.5

2.5

2
N=180(rpm)
N=210(rpm)
Vdf(mm/s)(Cal.)
2

1.5

I D
S
N=240(rpm)
1.5 N=270(rpm) 1
Vdf(mm/s)

f
1 0.5
PSO GA

0.5

o
0
0 0.5 1 1.5 2 2.5
0
Vdf(mm/s)(Exp.)
0.42 0.62 0.82 1.02 1.22

e
Vcf(mm/s) Figure 8. Comparison between experimental data and the
predictions of Equation (7).
Figure 7. Experimental variation in Vdf with Vcf (Toluene –

iv
Water).
TABLE 8. ARD for different models of flooding velocities
Investigator Column type ARD(%)

h
TABLE 7. Optimum parameters values of Equation 7
Method n1 n2 n3 n4 n5 n6 ARD% Gholam Samani et al. [30] pulsed packed 8.80

c
GA 2.89 -9.93 -3.60 -1.97 2.27 -1.18 11.56 Gholam Samani et al. [30] pulsed packed 7.80

r
PSO 2.82 -9.97 -3.59 -1.98 2.28 -1.18 11.54 Ousmane[22] pulsed packed 10.00
Torab-Mostaedi[13] Hanson Mixer-Settler 7.08
pulsed disc and

A
Torab-Mostaedi[15] 7.32
doughnut
In order to reduce error and increase the accuracy,
the numerical methods including GA and POS were This work Kuhni column 5.70
used to obtain the optimum parameters of Equation (7).
The methods were used to fit the experimental data and
to obtain the parameters and minimize the relative 8. CONCLUSIONS
absolute error. The results are presented in Table 7. The
relative absolute error (ARD%) the following objective In this work, an experimental study of mean drop size
function was minimized. and flooding velocity in a Kühni extraction column was
V f
Exp .
 V fCal . 
presented. The effects of agitation speed, dispersed
phase and continuous phase flow rates, on drop sizes
ARD%  100  (8)
V fExp. and flooding velocity were introduced. The results
showed that Sauter-mean drop diameter is strongly
The comparison of the experimental data with those affected by agitation speed as well as interfacial tension
calculated by Equation (7) is shown in Figure 8. This whereas volumetric flow rates of the dispersed and
figure shows that the experimental results are in good continuous phase have almost no significant effect.
agreement with calculated values obtained by Equation Sauter-mean drop diameter decreases with both
(7). This correlation reproduces the experimental results increases in rotor speed and decrease in interfacial
with an average relative deviation of 7.2 %.

www.SID.ir
295 A.R. Shirvani et al. / IJE TRANSACTIONS C: Aspects Vol. 29, No. 3, (March 2016) 288-296

tension. Two rigorous empirical correlations for 13. TORAB, M.M., SAFDARI, J. and ASADOLLAHZADEH, M.,
"Mean drop size and drop size distribution in a hanson mixer-
predictions of flooding velocity and drop size diameter
settler extraction column", (2012).
in Kuhni columns were presented. The correlations are
14. Godfrey, J.C. and Slater, M.J., "Liquid-liquid extraction
functions of operating variables, the physical properties equipment, Wiley Chichester, UK, and New York, (1994).
of liquid systems and column geometry. The results 15. Torab-Mostaedi, M., Ghaemi, A. and Asadollahzadeh, M.,
showed that the maximum throughput decreases with "Flooding and drop size in a pulsed disc and doughnut extraction
the increase in agitation speed and flow ratio, while it column", Chemical Engineering Research and Design, Vol.
increases with the increase in interfacial tension. The 89, No. 12, (2011), 2742-2751.
predictive correlations can be used for prediction of 16. Spaay, N., Simons, A. and Ten Brink, G., "Design and operation
of a pulsed packed column for liquid-liquid extraction", in Proc.
maximum capacity of existing Kühni columns and final Internal. Solvent Extraction Conf., ISEC. Vol. 71, (1971), 19-23.
sizing of the column diameter.
17. Kumar, A. and Hartland, S., "Gravity settling in liquid/liquid
dispersions", The Canadian Journal of Chemical Engineering,
Vol. 63, No. 3, (1985), 368-376.
9. REFERENCES 18. Calabrese, R.V., Chang, T. and Dang, P., "Drop breakup in
turbulent stirred‐tank contactors. Part i: Effect of dispersed‐

D
phase viscosity", AIChE Journal, Vol. 32, No. 4, (1986), 657-
1. Ozawa, M., Suzuki, S. and Takeshita, K., "Advanced
666.
hydrometallurgical separation of actinides and rare metals in

I
nuclear fuel cycle", Solvent Extraction Research and 19. Rinconrubio, L., Kumar, A. and Hartland, S., "Drop-size
Development, Japan, Vol. 17, No. 0, (2010), 19-34. distribution and average drop size in a wirz extraction column",
Chemical engineering research & design, Vol. 72, No. 4,

S
2. Habaki, H., Yoshimura, Y. and Egashira, R., "Liquid-liquid
(1994), 493-502.
equilibrium extraction of aromatic compounds from model
hydrocarbon mixtures for separation of cracked oils", Solvent 20. Kumar, A. and Hartland, S., "Correlations for prediction of mass
Extraction Research and Development, Japan, Vol. 20, No. 0, transfer coefficients in single drop systems and liquid–liquid

3.
(2013), 169-174.
Habaki, H., Shimada, Y. and Egashira, R., "Separation of coal
tar absorption oil by an ionic liquid supported liquid membrane",
Solvent Extraction Research and Development, Japan, Vol.
20, No. 0, (2013), 175-181.

o f
extraction columns", Chemical Engineering Research and
Design, Vol. 77, No. 5, (1999), 372-384.
21. Torab-Mostaedi, M., Safdari, J. and Torabi-Hokmabadi, F.,
"Prediction of mean drop size in pulsed packed extraction
columns", Iranian Journal of Chemical Engineering, Vol. 8,
No. 4, (2011).

e
4. Sadrnezhaad, S. and Alamdari, E.K., "Thermodynamics of
extraction of zn2+ from sulfuric acid media with a mixture of 22. Ousmane, S., Isabelle, M., Mario, M.-S., Mamadou, T. and
dehpa and mehpa", International Journal Of Engineering Jacques, A., "Study of mass transfer and determination of drop

iv
Transactions B, Vol. 17, (2004), 191-200. size distribution in a pulsed extraction column", Chemical
Engineering Research and Design, Vol. 89, No. 1, (2011), 60-
5. Hosseinzadeha, M., Alizadeh, M., Ranjbara, M. and Pazoukib,
68.
M., "Improvement of the solvent extraction of rhenium from
molybdenite roasting dust leaching solution using counter- 23. Asadollahzadeh, M., Torab-Mostaedi, M., Shahhosseini, S. and

h
current extraction by a mixer-settler extractor", International Ghaemi, A., "Experimental investigation of dispersed phase
Journal of Engineering-Transactions A: Basics, Vol. 27, No. holdup and flooding characteristics in a multistage column

c
4, (2013), 651-658. extractor", Chemical Engineering Research and Design, Vol.
105, (2016), 177-187.
6. Nabli, M.A., Guiraud, P. and Gourdon, C., "Cfd contribution to

r
a design procedure for discs and doughnuts extraction columns", 24. Hemmati, A., Shirvani, M., Torab-Mostaedi, M. and Ghaemi,
Chemical Engineering Research and Design, Vol. 76, No. 8, A., "Hold-up and flooding characteristics in a perforated rotating
(1998), 951-960. disc contactor (prdc)", RSC Advances, Vol. 5, No. 77, (2015),
63025-63033.

A
7. Bastani, D., "Stagewise modeling of liquid-liquid extraction
column (rdc)", International Journal Of Engineering 25. Kennedy, J., Particle swarm optimization, in Encyclopedia of
Transactions B, Vol. 17, No. 1, (2004), 7-17. machine learning. 2011, Springer.760-766.
8. Nii, S., Suzuki, J., Tani, K. and Takahashi, K., "Mass transfer 26. Engelbrecht, A.P., "Fundamentals of computational swarm
coefficients in mixer-settler extraction column", Journal of intelligence, John Wiley & Sons, (2006).
chemical engineering of Japan, Vol. 30, No. 6, (1997), 1083- 27. Holland, J.H., "Adaptation in natural and artificial systems. An
1089. introductory analysis with application to biology, control, and
9. Pietzsch, W. and Pilhofer, T., "Calculation of the drop size in artificial intelligence", Ann Arbor, MI: University of Michigan
pulsed sieve-plate extraction columns", Chemical engineering Press, (1975).
science, Vol. 39, No. 6, (1984), 961-965. 28. Goldberg, D.E., "Genetic algorithms in search optimization and
10. Yaparpalvi, R., Das, P., Mukherjee, A. and Kumar, R., "Drop machine learning, Addison-wesley Reading Menlo Park, Vol.
formation under pulsed conditions", Chemical engineering 412, (1989).
science, Vol. 41, No. 10, (1986), 2547-2553. 29. Grefenstette, J.J. and Baker, J.E., "How genetic algorithms
11. Kumar, A. and Hartland, S., "Unified correlations for the work: A critical look at implicit parallelism", in Proceedings of
prediction of drop size in liquid-liquid extraction columns", the third international conference on Genetic algorithms,
Industrial & engineering chemistry research, Vol. 35, No. 8, Morgan Kaufmann Publishers Inc. (1989), 20-27.
(1996), 2682-2695. 30. Samani, M.G., Asl, A.H., Safdari, J. and Torab-Mostaedi, M.,
12. Misek, T., Berger, R. and Schröter, J., "Standard test systems for "Drop size distribution and mean drop size in a pulsed packed
liquid extraction studies", EFCE Publ. Ser, Vol. 46, No. 1, extraction column", Chemical Engineering Research and
(1985). Design, Vol. 90, No. 12, (2012), 2148-2154.

www.SID.ir
‫‪A.R. Shirvani et al. / IJE TRANSACTIONS C: Aspects Vol. 29, No. 3, (March 2016) 288-296‬‬ ‫‪296‬‬

‫‪Experimental Investigation of Flooding and Drop Size in a Kuhni Extraction Column‬‬


‫‪A.R. Shirvani,a A. Ghaemi a, M. Torab-Mostaedi b‬‬
‫‪a Department‬‬ ‫‪of Chemical Engineering, Iran University of Science and Technology‬‬
‫‪b Nuclear‬‬ ‫‪Fuel Cycle Research School, Nuclear Science and Technology Research Institute‬‬

‫‪PAPER INFO‬‬ ‫چكيده‬

‫‪Paper history:‬‬
‫‪Received 18October 2015‬‬ ‫در این تحقیق‪ ،‬قطر متوسط ساتر و رفتار طغیان به صورت تجربی در یک ستون استخراج کوهنی مورد بررسی قرار گرفته‬
‫‪Received in revised form 20February 2016‬‬
‫‪Accepted 03March 2016‬‬ ‫است‪ .‬آزمایشات تجربی بدون انجام انتقال جرم برای دو سیستم شیمیائی استاندارد انجام گرفته است‪ .‬در آزمایشات‬
‫پارامترهای عملیاتی شامل دور همزن‪ ،‬دبی هر دو فاز و کشش سطحی مطالعه شده است‪ .‬قطر متوسط قطره‪ ،‬سرعت طغیان‬

‫‪D‬‬
‫‪Keywords:‬‬
‫‪Kuhni Column‬‬ ‫و ماندگی در حالت طغیان در ستون کوهنی اندازه گیری شده است‪ .‬نتایج نشان داد که قطر متوسط ساتر به سرعت همزن و‬

‫‪I‬‬
‫‪Flood Point‬‬
‫‪Holdup‬‬
‫کشش سطحی وابسته بوده اما اثرات دبی فاز پیوسته و فاز پراکنده ناچیز می باشد‪ .‬دو رابطه تجربی دقیق برای پیش بینی‬
‫‪Sauter-Mean Drop Diameter‬‬ ‫سرعت طغیان و اندازه متوسط قطره با متوسط انحراف به ترتیب ‪ 5/7‬و ‪ 7/2‬درصد ارائه گردید‪ .‬رابطه متوسط قطر قطره‬

‫‪S‬‬
‫تابعی از هندسه ستون‪ ،‬شرایط عملیاتی و خصوصیات سیستم های مایع می باشد‪ .‬تطابق خوبی بین داده های تجربی و‬
‫مقادیر پیش بینی شده توسط داده های روابط ارائه شده در کلیه شرایط عملیاتی برقرار می باشد‪.‬‬

‫‪doi: 10.5829/idosi.ije.2016.29.03c.02‬‬

‫‪f‬‬
‫‪e‬‬ ‫‪o‬‬
‫‪i‬‬ ‫‪v‬‬
‫‪c‬‬ ‫‪h‬‬
‫‪A‬‬ ‫‪r‬‬

‫‪www.SID.ir‬‬

You might also like