Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

Final Exam
Due Feb 5 at 9:15am Points 100 Questions 40
Available Feb 5 at 8am - Feb 5 at 9:15am 1 hour and 15 minutes Time Limit None

Instructions
The following exam is designed to assess your knowledge on the second half of the course. Content
covered in this exam includes:

Heat Pumps

Exam specifics include:

1 attempt
40 questions worth 2.5 points each
10% of final grade

Attempt History
Attempt Time Score
LATEST Attempt 1 28 minutes 100 out of 100

 Correct answers are hidden.

Score for this quiz: 100 out of 100


Submitted Feb 5 at 8:30am
This attempt took 28 minutes.

Question 1 2.5 / 2.5 pts

Ultraviolet lights can help eliminate mold or bacteria.

True

False

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 1/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

Question 2 2.5 / 2.5 pts

Heat pump systems can use just two standard TXVs piped in series to
regulate refrigerant flow for normal operation in heating or cooling mode.

True

False

Question 3 2.5 / 2.5 pts

Electric crankcase heaters are used to warm a heat pump's compressor


dome prior to start-up.

False

True

Question 4 2.5 / 2.5 pts

To prevent snow from blocking side airways, install ____.

solar panels

auxiliary heaters

risers

ducts

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 2/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

Question 5 2.5 / 2.5 pts

When a heat pump is operating in heating mode, the outdoor coil


functions as a(n) ____ by absorbing heat.

condenser

evaporator

compressor

metering device

Question 6 2.5 / 2.5 pts

Which of the following statements about a heat pump operating in cooling


mode is false?

The indoor coil functions as an evaporator.

The compressor pumps high-pressure refrigerant vapor into the indoor coil.

The refrigerant vapor gives up its heat to the outside air as it flows through
the outdoor coil.

The outdoor coil functions as a condenser.

Question 7 2.5 / 2.5 pts

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 3/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

During the cooling mode in a heat pump, the reversing valve routes
refrigerant from the compressor to the outdoor coil.

True

False

Question 8 2.5 / 2.5 pts

Auxiliary heat for a heat pump ____.

is not as efficient as normal system operation

All of the above.

may use electric heating coils in the supply air ducts

is needed when it is not possible for the heat pump to extract enough heat
from the outside air

Question 9 2.5 / 2.5 pts

How should you clean the outdoor unit of a residential heat pump?

Use biocide tablets in water.

Apply an acid coil cleaner and rinse with water.

Apply a non-acid coil cleaner and rinse with water.

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 4/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

Use a hose to rinse.

Question 10 2.5 / 2.5 pts

A crankcase heater warms a heat pump compressor to vaporize any liquid


refrigerant that may have entered the compressor during the Off cycle.

False

True

Question 11 2.5 / 2.5 pts

A heat pump that circulates water through a secondary circuit that is


placed underground or underwater is a(n) ____ heat pump.

air-source

direct-exchange

air-to-air

water-source

Question 12 2.5 / 2.5 pts

A heat pump that uses the outside air as a heat source or a heat sink for
producing the desired temperature in a conditioned space is a(n) ____
heat pump.

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 5/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

ground-source

geothermal

air-source

water-source

Question 13 2.5 / 2.5 pts

A heat pump with a 13-SEER rating is ____ a 12-SEER heat pump.

as efficient as

more efficient than

less efficient than

not comparable to

Question 14 2.5 / 2.5 pts

A water-source heat pump uses water as a heat-transfer medium.

False

True

Question 15 2.5 / 2.5 pts

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 6/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

During winter heating, a heat pump system only requires temperature


controls to keep the system operating.

True

False

Question 16 2.5 / 2.5 pts

An air-source heat pump may emit steam in cold weather as it defrosts.

True

False

Question 17 2.5 / 2.5 pts

The direction of refrigerant flow through a compressor in a heat pump


system changes direction when the system switches between heating and
cooling modes.

False

True

Question 18 2.5 / 2.5 pts

Which of the following statements about heat pump compressors is false?

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 7/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

A crankcase heater can help protect a compressor from migrating


refrigerant.

They operate at lower ambient temperatures than most air-conditioning


compressors.

Suction line accumulators are used to protect the compressor from liquid
slugging.

One-way filter-driers protect the compressor from liquid slugging.

Question 19 2.5 / 2.5 pts

A ground coil is an underground length of tubing through which refrigerant


is circulated.

False

True

Question 20 2.5 / 2.5 pts

Residential heat pumps should be inspected and serviced every five


years.

False

True

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 8/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

Question 21 2.5 / 2.5 pts

Solar heating systems help heat pumps provide heating at a significant


operating cost.

True

False

Question 22 2.5 / 2.5 pts

A heat pump system requires more refrigerant in heating mode than in


cooling mode.

True

False

Question 23 2.5 / 2.5 pts

____ controls are needed to monitor ice buildup on the outdoor coil of an
air-to-air system.

Temperature

Defrost

Heat pump

Auxiliary heat

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 9/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

Question 24 2.5 / 2.5 pts

A heat pump that uses the earth as a heat source or a heat sink for
producing the desired temperature in a conditioned space is a(n) ____
heat pump.

air-source

air-to-air

air-to-water

ground-source

Question 25 2.5 / 2.5 pts

An air-source heat pump's heating cycle ____ as the outdoor temperature


drops.

becomes more efficient

becomes less efficient

remains unchanged

ends

Question 26 2.5 / 2.5 pts

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 10/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

A ground-source heat pump that circulates refrigerant through an outdoor


coil that is placed in direct contact with the earth is a(n) ____ heat pump.

air-to-air

direct-exchange

air-to-water

water-source

Question 27 2.5 / 2.5 pts

Which of the following statements about charge compensator tanks is


false?

It is a canister with the heat pump's gas line running through it.

The liquid line is connected to the tank and fills it with liquid refrigerant.

During the cooling mode, the gas line cools liquid refrigerant in the tank.

The gas line does not open inside the tank.

Question 28 2.5 / 2.5 pts

Basic heat pump theory rests on the principle that heat moves naturally
from cooler substances to warmer substances.

True

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 11/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

False

Question 29 2.5 / 2.5 pts

The price of operating electric heating systems is very cost-effective


compared to ground-source heat pumps.

True

False

Question 30 2.5 / 2.5 pts

Solar panels used in conjunction with heat pump systems ____.

All of the above.

provide sufficient heat regardless of outdoor temperature drop or thick


cloud cover

absorb heat from the sun

are usually sized to meet the all the heating needs of the heat pump

Question 31 2.5 / 2.5 pts

The higher the number rating on a heat pump, the more efficient the heat
pump is.

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 12/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

False

True

Question 32 2.5 / 2.5 pts

A heat pump system that continuously circulates the same water or


refrigerant is called an open-loop system.

False

True

Question 33 2.5 / 2.5 pts

A heat pump may use two metering devices in order to circulate


refrigerant in either direction.

False

True

Question 34 2.5 / 2.5 pts

An air coil circulates refrigerant and absorbs heat from or releases heat to
the air.

True

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 13/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

False

Question 35 2.5 / 2.5 pts

The smaller line in a heat pump system is referred to as the suction line.

True

False

Question 36 2.5 / 2.5 pts

A water loop circulates water through a length of tubing that is submerged


in a body of water.

True

False

Question 37 2.5 / 2.5 pts

Nearly ____% of all energy used in the home is for heating and cooling.

75

20

10

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 14/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

50

Question 38 2.5 / 2.5 pts

In a solar heating system, a hydronic coil is placed in the air handler


plenum.

True

False

Question 39 2.5 / 2.5 pts

Which of the following statements about flow check pistons is false?

Two are necessary for a heat pump to operate in cooling and heating
modes.

They meter refrigerant passing through in either direction.

Each has a valve assembly and a piston with a hole in its center.

They allow refrigerant to pass freely in one direction.

Question 40 2.5 / 2.5 pts

A reversing valve that uses a solenoid valve to direct high- and low-
pressure refrigerant to move the sliding section within the valve body is a
____.
https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 15/16
2/5/24, 12:14 AM Final Exam: HCR107-Air Conditioning Systems(020102DG)

pilot-operated reversing valve

biflow reversing valve

biflow thermostatic expansion valve

direct-acting reversing valve

Quiz Score: 100 out of 100

https://lincolnedu.instructure.com/courses/79867/quizzes/1724545?module_item_id=11829077 16/16

You might also like