Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 11

Data Input Original B31 G

t 0.562 Inch z 0.463 z ≤20 SF =


d 0.393 Inch Sflow 66 ksi z >20 SF =
L 2.5 Inch M 1.171
SMYS 60 ksi SF 58.55 ksi
D 24 Inch Pf 2,742 psig
Po 3000 psig So 64.06 ksi
Safety Fak 1.25

so x Saft fak 80.07 ksi > SF 58.55 ksi


ketentuan so x Saft fact < SF

maka

P<Pf/safety Fak 2,194 psig


20
20
58.55
19.847
Data Header Outlet
NPS 24 16
Wall thickness 0.312 Inch 0.312 Inch
Material API 5L X46 API 5L Gr.B
SMYS (S) 46,000 psig 35,000 psig
Tipe las SAW SAW
Design Pressure (P) 650 psig 650 psig
Design Temperature 100 ⁰F 100 ⁰F
Temperature Fact (T) 1 1
Location class 1 1
Design Factor (F) 0.6 0.6
Joint Factor (E) 1 1
CA
M 0.313 Inch
Sudut 90 ⁰
H 0.312 Inch
Header B 0.312 Inch

0.283 Inch
0.283 Inch

0.029 Inch

Branch / Outlet
Nominal required wall thickness
0.248 Inch

excess thk in header wall


0.064 Inch

Inside diameter of opening (d)


15.376 Inch
15.376

Luas yang dibutuhkan Luas yang dibutuhkan


4.351 in²

Luas tersedia Approximate required thickness of rinforcement,


0.446

0.78 used
1.093 0.78
0.100
3.829

thickness of rinforcement, t:
0.260
0.313

12.253
Data Header Outlet
NPS 24 16
Wall thickness 0.312 Inch 0.277 Inch
Material 5L X42 5L GR.B
SMYS (S) 41,100 psig 35,500 psig
Tipe las
Design Pressure (P) 600 psig 600 psig
Design Temperature
Temperature Fact (T) 1 1
Location class
Design Factor (F) 0.6 0.6
Joint Factor (E) 1 1
CA
M 0.250 Inch
Sudut 90 ⁰
H 0.312 Inch
Header B 0.277 Inch

0.292 Inch t req


0.292 Inch

0.020 Inch Excess Thickness

Branch / Outlet
Nominal required wall thickness
0.225 Inch t req

excess thk in header wall


0.052 Inch

Inside diameter of opening (d)


15.446 Inch ID outlet

Luas yang dibutuhkan Luas yang dibutuhkan


4.510 in²

Luas tersedia Approximate required thickness of rinforcement,


0.309

0.78 used
0.943 0.78
0.081
4.132

thickness of rinforcement, t:
0.277
0.313 0.277

13.222
Data Header Outlet
NPS 8.625 4.5
Wall thickness 0.322 Inch 0.237 Inch
Material 16000 16000
SMYS (S)
Tipe las 1 1
Design Pressure (P)
Design Temperature
Temperature Fact (T)
Location class
Design Factor (F)
Joint Factor (E)
CA
M
Sudut
H 0.322 Inch
Header B 0.237 Inch

#DIV/0!

#DIV/0!

Branch / Outlet
Nominal required wall thickness
#DIV/0!

excess thk in header wall


#DIV/0!

Inside diameter of opening (d)


4.026 Inch

Luas yang dibutuhkan Luas yang dibutuhkan


0.000 in²

Luas tersedia Approximate required thickness of rinforcement,


0.000

0.805 used
0.593 0.5925
#DIV/0!
#DIV/0!

thickness of rinforcement, t:
#DIV/0!
0.313

#DIV/0!