Op nbr 911-011
ЗАБЕЛЕЖКА!
Disconnected hoses, lines and connections must be plugged. Oil that drains from hoses, lines and connections should be
collected in a container.
1. Park the machine on a level surface, lower the bucket to the ground and stop the engine.
Operate each control lever (for attachment and travel) to its full stroke to release the residual pressure.
2. Press the air breather cap several times to release the pressure until the air is all out.
3. Connect vacuum pump (1) to the hydraulic tank, and actuate when disconnecting the hose.
Figure 1
Connection, vacuum pump
Figure 3
Removal, oil cooler outlet hose
ЗАБЕЛЕЖКА!
At this time, there are many leakage, therefore prepare a container and plug the hose.
Figure 4
Removal, oil cooler inlet hose
Tool: Hex bit socket 8 mm
Figure 5
Removal, screws
ЗАБЕЛЕЖКА!
After removing mounting screws of air conditioner condenser, place air conditioner condenser (1) one side not to
damage.
Figure 6
Removal, screws
Tools: Socket 19 mm
10. Disassemble oil cooler mounting brackets (1) and install them to the new oil cooler.
Figure 8
Transfer, oil cooler mounting bracket
Figure 9
Installation, screws
Figure 11
Installation, oil cooler inlet hose
Figure 12
Installation, oil cooler outlet hose