Amodel® AS-4133 HS

Polyphthalamide www.ulprospector.com
Solvay Specialty Polymers
Technical Data

Product Description
Amodel® AS-4133 HS is a 33% glass reinforced, lubricated, heat stabilized grade of polyphthalamide (PPA) that offers fast cycle times and
moldability in hot water molds. Testing conducted on samples dry as molded and samples conditioned to 50% relative humidity in accordance
with ISO-1110, Accelerated Method. Typical applications include electrical and electronic components especially for automotive systems.

• Black: AS-4133 HS BK 324


• Natural: AS-4133 HS NT
General
Material Status • Commercial: Active
Literature 1 • Technical Datasheet
UL Yellow Card 2 • E95746-253240

Search for UL Yellow Card


• Solvay Specialty Polymers
• Amodel®
• Africa & Middle East • Europe
Availability • North America
• Asia Pacific • Latin America
Filler / Reinforcement • Glass Fiber, 33% Filler by Weight
Additive • Heat Stabilizer • Lubricant • Mold Release
• Chemical Resistant • Good Stiffness • Hot Water Moldability
Features
• Creep Resistant • Heat Stabilized • Laser Weldable
• Fast Molding Cycle • High Heat Resistance • Low Moisture Absorption
• Good Dimensional Stability • High Strength • Lubricated

• Automotive Applications • Electrical/Electronic


Applications • Machine/Mechanical Parts
• Automotive Electronics
• General Purpose • Metal Replacement
Uses • Automotive Under the Hood
• Industrial Applications • Thick-walled Parts
• Cell Phones
• Industrial Parts • Valves/Valve Parts
• Connectors
• Lawn and Garden Equipment
RoHS Compliance • RoHS Compliant
Appearance • Black • Natural Color
Forms • Pellets
Processing Method • Water-Heated Mold Injection Molding
Multi-Point Data • Isothermal Stress vs. Strain • Secant Modulus vs. Strain (ISO • Viscosity vs. Shear Rate (ISO
(ISO 11403) 11403) 11403)

Physical Dry Conditioned Unit Test Method


Density 1.45 -- g/cm³ ISO 1183/A
Molding Shrinkage ASTM D955
Flow 0.50 -- %
Across Flow 1.0 -- %
Water Absorption (24 hr) 0.29 -- % ASTM D570
Mechanical Dry Conditioned Unit Test Method
Tensile Modulus
-- 11700 11700 MPa ASTM D638
23°C 12600 -- MPa ISO 527-1
100°C 6830 -- MPa ISO 527-1
150°C 5310 -- MPa ISO 527-1
175°C 4830 -- MPa ISO 527-1

1 of 4 Form No. TDS-22398-en


UL LLC ©2023. All rights reserved. Document Created: Friday, December 15, 2023
UL Prospector | 800-788-4668 or 307-742-9227 | www.ulprospector.com.

The information presented here was acquired by UL from the producer of the product or material or original information provider. However, UL
assumes no responsibility or liability for the accuracy of the information contained on this website and strongly encourages that upon final product
or material selection information is validated with the manufacturer. This website provides links to other websites owned by third parties. The
content of such third party sites is not within our control, and we cannot and will not take responsibility for the information or content.
Amodel® AS-4133 HS
Polyphthalamide
Solvay Specialty Polymers www.ulprospector.com

Mechanical Dry Conditioned Unit Test Method


Tensile Stress
Break, 23°C 211 -- MPa ISO 527-2
Break, 100°C 125 -- MPa ISO 527-2
Break, 150°C 87.6 -- MPa ISO 527-2
Break, 175°C 79.3 -- MPa ISO 527-2
-- 200 172 MPa ASTM D638
Tensile Elongation
Break 2.5 2.2 % ASTM D638
Break, 23°C 2.6 -- % ISO 527-2
Break, 100°C 4.3 -- % ISO 527-2
Break, 150°C 6.6 -- % ISO 527-2
Break, 175°C 6.6 -- % ISO 527-2
Flexural Modulus
-- 11000 11000 MPa ASTM D790
23°C 10400 -- MPa ISO 178
100°C 7170 -- MPa ISO 178
150°C 4620 -- MPa ISO 178
175°C 4210 -- MPa ISO 178
Flexural Strength
-- 290 241 MPa ASTM D790
23°C 296 -- MPa ISO 178
100°C 177 -- MPa ISO 178
150°C 111 -- MPa ISO 178
175°C 99.3 -- MPa ISO 178
Compressive Strength 179 172 MPa ASTM D695
Shear Strength 89.6 75.8 MPa ASTM D732
Poisson's Ratio 0.41 -- ASTM E132
Impact Dry Conditioned Unit Test Method
Charpy Notched Impact Strength (23°C) 11 -- kJ/m² ISO 179/1eA
Charpy Unnotched Impact Strength (23°C) 67 -- kJ/m² ISO 179/1eU
Notched Izod Impact
-- 80 69 J/m ASTM D256
23°C 9.7 -- kJ/m² ISO 180/1A
Unnotched Izod Impact
-- 960 -- J/m ASTM D4812
23°C 59 -- kJ/m² ISO 180/1U

2 of 4 Form No. TDS-22398-en


UL LLC ©2023. All rights reserved. Document Created: Friday, December 15, 2023
UL Prospector | 800-788-4668 or 307-742-9227 | www.ulprospector.com.

The information presented here was acquired by UL from the producer of the product or material or original information provider. However, UL
assumes no responsibility or liability for the accuracy of the information contained on this website and strongly encourages that upon final product
or material selection information is validated with the manufacturer. This website provides links to other websites owned by third parties. The
content of such third party sites is not within our control, and we cannot and will not take responsibility for the information or content.
Amodel® AS-4133 HS
Polyphthalamide
Solvay Specialty Polymers www.ulprospector.com

Thermal Dry Conditioned Unit Test Method


Deflection Temperature Under Load
0.45 MPa, Annealed, 3.20 mm 320 -- °C ASTM D648
1.8 MPa, Unannealed 294 -- °C ISO 75-2/A
1.8 MPa, Annealed, 3.20 mm 300 -- °C ASTM D648
Continuous Use Temperature 4 210 -- °C ASTM D3045
ASTM D3418
Melting Temperature 320 -- °C
ISO 11357-3
CLTE ASTM E831
Flow : 0 to 100°C 2.0E-5 -- cm/cm/°C
Flow : 100 to 200°C 1.5E-5 -- cm/cm/°C
Transverse : 0 to 100°C 7.6E-5 -- cm/cm/°C
Transverse : 100 to 200°C 1.2E-4 -- cm/cm/°C
Electrical Dry Conditioned Unit Test Method
Volume Resistivity 2.0E+16 5.0E+14 ohms·cm ASTM D257
Dielectric Strength (1.60 mm) 20 20 kV/mm ASTM D149
Dielectric Constant ASTM D150
60 Hz 3.80 4.30
1 MHz 3.60 3.40
Dissipation Factor ASTM D150
60 Hz 4.0E-3 0.020
1 MHz 0.012 0.019
Comparative Tracking Index (CTI)
-- 600 600 V UL 746A
-- 600 -- V IEC 60112
High Voltage Arc Tracking Rate (HVTR) 14.0 18.0 mm/min UL 746A
Flammability Dry Conditioned Unit Test Method
Flame Rating 5 (3.2 mm) HB -- UL 94
Optical Dry Conditioned Unit Test Method
Transmittance 6 ASTM D1003
1070 nm : 1.60 mm > 20 -- %
940 nm : 1.60 mm > 20 -- %

Injection Dry Unit


Drying Temperature 120 °C
Drying Time 4.0 hr
Suggested Max Moisture 0.030 to 0.060 %
Rear Temperature 318 to 324 °C
Front Temperature 327 to 332 °C
Processing (Melt) Temp 329 to 343 °C
Mold Temperature 66 to 140 °C

3 of 4 Form No. TDS-22398-en


UL LLC ©2023. All rights reserved. Document Created: Friday, December 15, 2023
UL Prospector | 800-788-4668 or 307-742-9227 | www.ulprospector.com.

The information presented here was acquired by UL from the producer of the product or material or original information provider. However, UL
assumes no responsibility or liability for the accuracy of the information contained on this website and strongly encourages that upon final product
or material selection information is validated with the manufacturer. This website provides links to other websites owned by third parties. The
content of such third party sites is not within our control, and we cannot and will not take responsibility for the information or content.
Amodel® AS-4133 HS
Polyphthalamide
Solvay Specialty Polymers www.ulprospector.com

Injection Notes
Injection Rate: 3 to 4 in/sec
Holding Pressure: 50% of injection pressure

Storage:
• Amodel® compounds are shipped in moisture-resistant packages at moisture levels according to specifications. Sealed, undamaged bags
should be preferably stored in a dry room at a maximum temperature of 50°C (122°F) and should be protected from possible damage. If
only a portion of a package is used, the remaining material should be transferred into a sealable container. It is recommended that Amodel®
resins be dried prior to molding following the recommendations found in this datasheet and/or in the Amodel® processing guide.

Notes
1 These links provide you with access to supplier literature. We work hard to keep them up to date; however you may find the most current literature
from the supplier.
2 A UL Yellow Card contains UL-verified flammability and electrical characteristics. UL Prospector continually works to link Yellow Cards to
individual plastic materials in Prospector, however this list may not include all of the appropriate links. It is important that you verify the association
between these Yellow Cards and the plastic material found in Prospector. For a complete listing of Yellow Cards, visit the UL Yellow Card Search.
3 Typical properties: these are not to be construed as specifications.
4 1500 hr
5 These flammability ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions.
6 Transmittance for natural grade

4 of 4 Form No. TDS-22398-en


UL LLC ©2023. All rights reserved. Document Created: Friday, December 15, 2023
UL Prospector | 800-788-4668 or 307-742-9227 | www.ulprospector.com.

The information presented here was acquired by UL from the producer of the product or material or original information provider. However, UL
assumes no responsibility or liability for the accuracy of the information contained on this website and strongly encourages that upon final product
or material selection information is validated with the manufacturer. This website provides links to other websites owned by third parties. The
content of such third party sites is not within our control, and we cannot and will not take responsibility for the information or content.

You might also like