6 ULTRASONIC LEVEL LST400 / OPEN CHANNEL FLOW TRANSMITTER DS/LST400–EN REV.

Specification
Accuracy
General
0.25 % FSD, 0.5 % of reading (whichever is greater)
Inputs
One level transducer with integrated temperature sensor
Resolution
0.1 % at 10 mA, 0.05 % at 20 mA
Range
0.5m to 15m (S15, C15, F15)
1.5m to 30m (S30) Maximum load resistance
750 at 20 mA

Accuracy
Communications
0.25% full span with temperature compensation or 3 mm (0.11 in)
(whichever is greater) HART 7 as standard

Access to functions
Repeatability
Direct keypad access
0.15 % full span
Measurement, maintenance, configuration, diagnostics and
service functions.
Temperature compensation
Performed without external equipment or internal jumpers.
NTC 10 k thermistor
Range –40 to 80 C (–40 to 176 F)
Mechanical data
Wall / Pipe-mount versions transmitter
Measurement modes
IP65 / NEMA 4X, Glass Loaded Polycarbonate
Level
Distance Size (W x D x H)
Linearized level (21-point linearizer) 230 x 94 x 192 mm (9.06 x 3.70 x 7.56 in)
Open channel flow with preconfigured flow curves for most Weight 1 kg (2.2 lb)
common channels
Cable Entry Types
Rate of change 7 x knockouts suitable for M20 or 1/2" NPT cable glands
0.03 to 65 ft / minute; 0.01 to 20 m / minute Supplied with 5 x M20 or 5 x 1/2" NPT cable glands

Display
Power supply
Type
Voltage requirements
128 x 64 dot graphic display
110 V AC or 240 V AC 15 %, 50/60 Hz, 5 VA
20 to 30 V DC, 4 VA
Energy-saving function
Backlit LCD configurable as ON or Auto-Off after one to
Environmental data
six minutes
Operating temperature limits
–20 to 65 C (–4 to 149 F)
Relay output
Number of relays
Storage temperature limits
Five supplied as standard
–25 to 75 C (–13 to 167 F)

Set point adjustment


Configurable as high/low set point
EMC
Emissions and immunity
Meets r equir ements of EN61326-3 (for an industrial
Hysteresis
environment)
Configurable as reset point

Approvals, certification and safety


Cycling options
CE Mark
Programmable for First in First Out (FIFO) or Cycle Mode
EMC Directive 2006/95/EC (IEC 61010-1)
LV Directives 2004/108/EC (IEC 61326-3 for an industrial
Relay contacts
environment)
Single-pole changeover
Rating 8 A, 115/230 V AC, 8 A DC
General safety
Analog output EN61010-1
Ranges
4 to 20 mA
Analog output programmable to select 3.6 mA, 4 mA, 20 mA,
21 mA or hold last value in case of system failure.
ULTRASONIC LEVEL LST400 / OPEN CHANNEL FLOW TRANSMITTER DS/LST400–EN REV. F 7

Sensor specifications
Type

Model

For use in bulk solid level


For use on liquids up to
measurement up to a range of
Corrosion resistant housing
ideal for chemically
Suitable for potable and face improves acoustic
aggressive environments. and waste water
waste water applications matching for better
applications
Design performance on solids.

Measurement range
Acoustic window material Glass reinforced epoxy Glass reinforced epoxy PVDF Glass reinforced epoxy

Housing material Glass filled polyester Glass filled polyester PVDF Glass filled polyester

Operating frequency
Process temperature limits C C C C

ABB Engineering (Shanghai) Ltd.
No. 4528, Kangxin Highway, Pudong New District,
Shanghai, 201319, P.R.China
Tel: +86 21 6105 6666
Fax: +86 21 6105 6677

ABB Inc.
125 E. County Line Rd
Warminster PA 18974-4995, USA
Tel: +1 215 674 6000
Fax: +1 215 674 7183

ABB Limited
Howard Road
St. Neots
Cambridgeshire PE19 8EU
UK
Tel: +44 (0)1480 475321
Fax: +44 (0)1480 217948

www.abb.com/level

Note
We reserve the right to make technical changes or modify the contents of this document
DS/LST400-EN Rev. F 2019.04

without prior notice. With regard to purchase orders, the agreed particulars shall prevail.
ABB does not accept any responsibility whatsoever for potential errors or possible lack
of information in this document.

We reserve all rights in this document and in the subject matter and illustrations
contained therein. Any reproduction, disclosure to third parties or utilization of its
contents add - in whole or in parts – is forbidden without prior written consent of ABB.

Copyright© 2019 ABB


All rights reserved