SERIES RHP | HUMIDITY/TEMPERATURE TRANSMITTERS

OSA (outside air) OSA (outside air) OSA


Duct mount with radiation shield with sintered filter (outside air)

FEATURES/BENEFITS
• Reduced installation cost with combined humidity and temperature
• Wide application environment from a large selection of temperature sensors and 2%, 3% and 5% accuracies
• Reduced system operating costs with radiation shield protecting the sensor from radiant heat

APPLICATIONS DESCRIPTION
• Air economizers The Series RHP Humidity/Temperature Transmitters combine the
• Outdoor temperature and relative humidity reference for building systems voltage or current humidity transmitter output with a passive temperature
thermistor or RTD output. The polymer capacitance humidity sensor
reduces longterm affect of condensation, fog, or high humidity. The
humidity sensors are available with 2%, 3% or 5%­accuracies. Duct
mounted transmitters are available with an optional two-line alpha
numeric LCD display.

SPECIFICATIONS
Relative Humidity Range 0 to 100% RH.
Temperature Range -40 to 140°F (-40 to 60°C).
Accuracy, RH RHP-2XXX ±2% 10-90% RH @ 25°C; RHP-3XXX ±3% 20-80% RH @ 25°C; RHP-5XXX ±5% 20-80% RH @
25°C.
Accuracy, Thermistor Temp Sensor ±0.2°C @ 25°C (±0.36°F @ 77°F).
Accuracy, RTD Temp Sensor DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F).
Accuracy, Solid State Band Gap ±0.9°F @ 77°F (±0.5°C @ 25°C).
Hysteresis ±1%.
Repeatability ±0.1% typical.
Temperature Limits -40 to 140°F (-40 to 60°C).
Storage Temperature -40 to 176°F (-40 to 80°C).
Compensated Temperature Range -4 to 140°F (-20 to 60°C).
Power Requirements 4-20 mA loop powered models: 10-35 VDC; 0-5/10 V output models: 15-35 VDC or 15-29 VAC.
Output Signal 4-20 mA; 0-5/10V @ 5 mA max.
(Model Dependent)
Response Time 15 s.
Electrical Connections Removable screw terminal block.
Conduit Connection Duct mount: 1/2˝ NPS; OSA: PG11 or PG16 (1/2˝ conduit) knockouts.
Drift < 1% RH/year.
RH Sensor Capacitance polymer.
Temperature Sensor Types 1, 2, 3: Solid state band gap; Curves A, B, C: Thermistor; Curves D, E: Platinum RTD DIN 385.
Enclosure Material Duct mount sensor tube: PVC-UL 94 V-0; Duct mount sensor cap: Polycarbonate ABS blend-greater than UL
94 V-0; Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB; OSA: Polycarbonate.
Enclosure Rating Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66).
Display Duct mount only, optional 2-line alpha numeric, 8 characters/line.
Display Resolution RH: 0.1%; 0.1°F (0.1°C).
Weight Duct mount: .616 lb (.3 kg); OSA: 1 lb (.45 kg).
Compliance CE.
DIMENSIONS
5-1/8 [3] 3/16 [4.76] HOLES
[130.18] 2-1/4 EQUALLY SPACED
[57.15] ON A 4.115 [104.52] BC

3-45/64 55/64
[94.06] [21.83] 2-9/16
[64.96]

6-25/32 2-11/64 2-11/64


[172.16] [55.17] [55.12]
1/2 NPT
2-41/64
2-41/64 [67.03] 8-61/64
[67.07] 2-9/64 [227.30]
[54.37]
OSA (outside air) with sintered filter 35/64
[13.89]
5-1/8 3-11/64
4-17/32 2-15/64 4-17/32 [130.18] [80.57] A-RHP-FC
[115.09] [56.75] [115.09]

3-1/8 Duct mount


3-1/8 [79.38]
[79.38]
1-13/64
[30.56]
6-25/32
Ø3/16 [172.09]
[4.76]
MOUNTING
HOLES
TYP 4 PLCS 55/64
[21.83]
OSA (outside air)

HOW TO ORDER
Use the bold characters from the chart below to construct a product code.
RHP -2 D 1 A -LCD

SERIES OPTIONS
RHP: RH/passive temperature sensor transmitter -LCD: LCD display
-NIST: NIST traceable calibration certificate
ACCURACY
-2: 2% accuracy TEMPERATURE SENSOR
-3: 3% accuracy 0: None
-5: 5% accuracy 1: 4-20 mA
2: 0-10 VDC
HOUSING TYPE 3: 0-5 VDC
D: Duct mount with plastic hydrophobic filter A: 10K @ 25°C thermistor type III
O: OSA (outside air) B: 10K @ 25°C thermistor type II
S: OSA with sintered filter* C: 3K @ 25°C thermistor
R: Radiation shield D: 100 Ω RTD DIN 385
E: 1K Ω RTD DIN 385
*Use OSA with sintered filter models when purchasing Series RHRS F: 20K Ω @ 25°C thermistor
separately.
RH OUTPUT
1: 4-20 mA
2: 0-10 V
ACCESSORIES 3: 0-5 VDC

Model Description
A-RHP-FC Replacement plastic hydrophobic filter
A-RHP-RT Retrofit tool for fitting O-ring on RHP-D/M models for new filter A-RHP-FC
Makrolon® is a registered trademark of Covestro AG.

ORDER ONLINE TODAY!


TODAY!
dwyer-inst.com/Product/SeriesRHP
DWYER INSTRUMENTS, LLC
©Copyright 2022 Dwyer Instruments, LLC
Printed in U.S.A. 3/22 DS-RHP Rev. 7

Important Notice: Dwyer Instruments, Inc. reserves the right to make changes to or discontinue any product or service identified in this publication without notice. Dwyer advises its customers to obtain the