175-026400 TIP Aramco
175-026400 TIP Aramco
0030 R X Welding Procedures Specifications (WPS#s) and Procedure Per ASME Sec. IX and 02-SAMSS-006
QualificationRecords (PQR#s)
0040 R X NDT Personnel & Procedures Check for valid personnel certification and procedure. RT Film
interpreter to meet SAEP-1142 requirements.
0020
0010
***R X
In process inspection & test requirement
Hardness test
Specification Details / Notes:
Per 02-SAMSS-006
0040 R X a) Radiographic Testing All butt welds in fabricated fittings shall be 100% radiographed
in accordance with ASME VIII Div.1, UW-51.
0050 R X b) Magnetic Particle Testing 02-SAMSS-006: For full penetration groove welds, in
accordance with ASME VIII Div. 1 Appx. 8.
0060 R X c) Magnetic Particle Testing or Dye Penetrant of Weld Ends for 02-SAMSS-006: All butt weld ends shall be tested PT (ASTM
Field Welding E165). Accept/reject to ASME Sec VIII, Div. 1, Appx. 8 or MT
(ASME Sec. VIII Div. 1 Appx. 8).
0070 R X d) Ultrasonic Testing of Plates In accordance with ASTM A578, acceptances level C or equal.
0080 R X Heat Treatment after Forming and Welding 02-SAMSS-006 and A234 or MSS SP-75: Limitations denoted
in SAMSS.
0090 X Repair Procedure of Defects Per 02-SAMSS-006. Vendor shall submit details of the repair
procedure and nondestructive testing of the repair area for
Inspection’s approval prior to making the repair.
0030 *** Final inspection & test requirements Specification Details / Notes:
IR026400 Continued...
INSPECTION & TESTING REQUIREMENTS REVISION: 04/05/2017 CODE NUMBER: PAGE:
SAUDI ARAMCO FORM-175 REPLACES: 06/16/2016 IR026400 2 of 2
(1).VISUAL INSPECTION BY BUYER INSPECTION REPRESENTATIVE
(2) REVIEW AND VERIFICATION OF MATERIAL CERTIFICATES AND INSPECTION RECORDS
(3) SUBMISSION OF MANUFACTURING, INSPECTION AND QUALITY RECORDS
0010 W R X Hydrostatic Tests Per 02-SAMSS-006
0040 W X Preparation for Shipping Per 02-SAMSS-006 and Purchase Order requirement.
0060 R X Product Test Certificate and records As per applicable SAMSS and IR
Notes:
(1) Refer detailed instruction sheet SA175 form IR000003 of inspection requirement for ideal use of this form.
(2) For sour service, Plates shall comply with 01-SAMSS-016, welded Pipes shall be HIC tested in accordance with 01-SAMSS-035 or
01-SAMSS-043 as applicable
End of IR026400