Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Stop type

Case B
Flash Report of Accident
F
(Absence accident )
Case : The victim's was repairing it using a gas welding equipment. The supply hose came off, flame ignited blown-out the right arm.
Location : Parts Supply Gate Date & Time : Apr 24th ,2022 at about 8:20 pm Injury Level : Right arm 1st degree burn

Detail of accident Factors


The victim was repairing the upper rail of the parts supply gate was bent 1) Pre-operation check of the equipment was omitted .
and the gate did not close. 2) The victim had noticed a failure of the acetylene pressure gauge,
but continued use it.
(1) The victim was repairing it using a gas welding equipment. 3) The victim did not wear the specified protective equipment
(2) When the acetylene supply hose came off the blow tube, the flame (gloves, arm covers, apron) but wore short sleeves.

ignited the blown-out gas and the right arm was burned. Countermeasure
1) Pre-operation check was thoroughly conducted.
2) It was ensured to report an equipment failure to a superior and not
to use the broken equipment.
3) Prepare a protective equipment checklist and check it before work

Essence : The victim doesn't check equipment before work and not
wear the specified protective equipment.

Yokoten point :
1) Pre-operation check was thoroughly conducted.
2) It was ensured to report an equipment failure to a superior and not to use the
broken equipment.
3) Prepare a protective equipment checklist and check it before work

You might also like