CHECK FOR DEFLECTION (Clause 3.4.6.7,Table 3.10 & 3.11 of CP 65 Part 1))
Mod.
fs=
5/8*(fyxAst Factor = d
Direction l/dprovided 0.55+ (477- l/dallowable Check
reqd/Ast
fs)/(120(0.9+K)
required
prov.)/βb
)≤2
DESIGN INPUTS
LOADING DATA
K' Spaci
Dia Req.
K= (max. As,req, ng As, prov,
Moment,Mu kNm of spacing
Mu/bd2 value mm2 provi mm2
bar mm
of K) ded
Main Reinf. 0.5wu.l^2 1.63 0.01 0.156 162.50 13 817 200 663.58
Distribution (Minimum Percentage ) 0.13 162.50 10 483 200 392.65
###
DESIGN INPUTS
LOADING DATA
K' Spaci
Dia Req.
K= (max. As,req, ng As, prov,
Moment,Mu kNm of spacing
Mu/bd2 value mm2 provi mm2
bar mm
of K) ded
Main Reinf. 0.5wu.l^2 4.05 0.01 0.156 162.50 13 817 200 663.58
Distribution (Minimum Percentage ) 0.13 162.50 10 483 200 392.65
###