Sprinkler Identification Numbers (SIN) V24XX, V26XX, V27XX, V29XX, V34XX, V35XX, V38XX, V39XX Series Glass Bulb Type. Painted or plated
sprinklers are identified by an unpainted or unplated compression screw.
V2707### SR Pendent 250 135, 155, 175, 200, 286, 360, 500
V2703### SR Upright 250 135, 155, 175, 200, 286, 360, 500
V2705 SR Recessed/Pendent 2.8 175 135, 155, 175, 200, 286, 360, 500
V2701 SR Upright 2.8 175 135, 155, 175, 200, 286, 360, 500
https://iq.ulprospector.com/en/profile?e=160279 1/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
*V2401 SR Upright 4.2 175 135, 155, 175, 200, 286, 360
*V2403 SR Pendent 4.2 175 135, 155, 175, 200, 286, 360
+V2759 SR Pendent 4.2 175 135, 155, 175, 200, 286, 360, 500
V3405# SR Pendent 3/4 175 135, 155, 175, 200, 286, 360
V3401# SR Upright 3/4 175 135, 155, 175, 200, 286, 360
V2710+ ### QR HSW 5.6 250 135, 155, 175, 200, 286
V2710+ ### QR Rec. HSW 5.6 250 135, 155, 175, 200
V2709+ ### SR HSW 5.6 250 135, 155, 175, 200, 286, 360, 500
https://iq.ulprospector.com/en/profile?e=160279 2/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
V3409+# SR HSW 8.0 175 135, 155, 175, 200, 286, 360
V2709+ ### SR Rec. HSW 5.6 250 135, 155, 175, 200
+ For ordinary and light hazard occupancies, installed 4 to 12 in. below the ceiling.
V3201## SR Pendent, Rec. 5.6 175 — 135, 155, 175, 200, 286
Pendent
V3202## QR Pendent, Rec. 5.6 175 — 135, 155, 175, 200, 286
Pendent
https://iq.ulprospector.com/en/profile?e=160279 3/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
DRY SPRINKLERS
System
Max Working
Response Length, Pressure, Nom
SIN Type Type In. psig K-Factor Temp Rating, °F
https://iq.ulprospector.com/en/profile?e=160279 4/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
V4001 SR Pendent, Rec. Pendent 36 175 11.5 155, 175, 200, 286
V4002 QR Pendent, Rec. Pendent 36 175 11.2 155, 175, 200, 286
V5643 QR Vertical Sidewall 48 175 5.6 135, 155, 175, 200, 286
V5687 SR Vertical Sidewall 48 175 5.6 135, 155, 175, 200, 286
V8143 QR Vertical Sidewall 48 175 8.0 135, 155, 175, 200, 286
V8187 SR Vertical Sidewall 48 175 8.0 135, 155, 175, 200, 286
V5634+ QR Dry Concealed Pendent 48 175 5.6 135, 155, 175, 200
V5689+ SR Dry Concealed Pendent 48 175 8.0 135, 155, 175, 200
The Dry Sprinklers Listed above may be coated with Nicotef coating for corrosion resistance.
+ The 135°F and 155°F sprinklers utilize a 135°F cover and the 200°F sprinklers utilize a 165°F cover.
https://iq.ulprospector.com/en/profile?e=160279 5/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
++ Upright style with minimum operation pressure of 12 psig.
V3415# HSW, Rec. HSW 16 16 26 8.0 4-6 135, 155, 175, 200
V3415# HSW, Rec. HSW 16 16 28 8.0 6-12 135, 155, 175, 200
V3415# HSW, Rec. HSW 16 18 29 8.0 4-6 135, 155, 175, 200
V3415# HSW, Rec. HSW 16 20 32 8.0 4-6 135, 155, 175, 200
V3415# HSW, Rec. HSW 16 18 33 8.0 6-12 135, 155, 175, 200
V3415# HSW, Rec. HSW 16 20 35 8.0 6-12 135, 155, 175, 200
https://iq.ulprospector.com/en/profile?e=160279 6/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
V3416# HSW, Rec. HSW 16 16 26 8.0 4-6 135, 155, 175, 200
V3416# HSW, Rec. HSW 16 16 28 8.0 6-12 135, 155, 175, 200
V3416# HSW, Rec. HSW 16 18 29 8.0 4-6 135, 155, 175, 200
V3416# HSW, Rec. HSW 16 20 32 8.0 4-6 135, 155, 175, 200
V3416# HSW, Rec. HSW 16 18 33 8.0 6-12 135, 155, 175, 200
V3416# HSW, Rec. HSW 16 20 35 8.0 6-12 135, 155, 175, 200
V2758 HSW, Rec. HSW 16 16 26 5.6 4-12 135, 155, 175, 200
V2758 HSW, Rec. HSW 16 18 29 5.6 4-12 135, 155, 175, 200
V2758 HSW, Rec. HSW 16 20 32 5.6 4-12 135, 155, 175, 200
V2758 HSW, Rec. HSW 16 22 36 5.6 4-12 135, 155, 175, 200
V2758 HSW, Rec. HSW 16 24 39 5.6 4-6 135, 155, 175, 200
V2758 HSW, Rec. HSW 16 24 40 5.6 6-10 135, 155, 175, 200
https://iq.ulprospector.com/en/profile?e=160279 7/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
https://iq.ulprospector.com/en/profile?e=160279 8/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
V3421# Pendent, Rec. Pendent 16x16 1 38 14.0 155, 175, 200, 286
V3421# Pendent, Rec. Pendent 16x16 2 51 14.0 155, 175, 200, 286
V3421# Pendent, Rec. Pendent 18x18 1 49 14.0 155, 175, 200, 286
V3421# Pendent, Rec. Pendent 18x18 2 65 14.0 155, 175, 200, 286
V3421# Pendent, Rec. Pendent 20x20 1 60 14.0 155, 175, 200, 286
V3421# Pendent, Rec. Pendent 20x20 2 80 14.0 155, 175, 200, 286
V1113 Pendent, Rec. Pendent 16X16 1 39 11.2 155, 175, 200, 286
V1113 Pendent, Rec. Pendent 16X16 2 51 11.2 155, 175, 200, 286
V1113 Pendent, Rec. Pendent 18X18 1 49 11.2 155, 175, 200, 286
V1113 Pendent, Rec. Pendent 18X18 2 65 11.2 155, 175, 200, 286
V1113 Pendent, Rec. Pendent 20X20 1 60 11.2 155, 175, 200, 286
V1113 Pendent, Rec. Pendent 20X20 2 80 11.2 155, 175, 200, 286
https://iq.ulprospector.com/en/profile?e=160279 9/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
Max Min
Width x Ordinary Sprinkler Temp
Length Hazard Flow Rate Nom Rating,
SIN Type ft x ft Group gpm K-Factor °F
V1113 Pendent, Rec. Pendent 11.2 VC-250 155, 175, 200, 286
V2709### HSW, Rec. HSW 5.6 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286, 360
V2710### HSW, Rec. HSW 5.6 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286
V2709### HSW, Rec. HSW 5.6 Wax, wax over lead 155, 200
V3409 HSW, Rec. HSW 8.0 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286, 360
V3410 HSW, Rec. HSW 8.0 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286
https://iq.ulprospector.com/en/profile?e=160279 10/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
V3409 HSW, Rec. HSW 8.0 Wax, wax over lead 155, 200
V2705 Pendent, Rec. Pendent 2.8 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286, 360,
500
V2706 Pendent, Rec. Pendent 2.8 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286
V2705 Pendent, Rec. Pendent 2.8 Wax, wax over lead 155, 200
V2707 Pendent, Rec. Pendent 5.6 Lead, Polyester, VC-250 135, 155, 175, 200, 286, 360,
500
V2708 Pendent, Rec. Pendent 5.6 Lead, Polyester, VC-250 135, 155, 175, 200, 286
V2707 Pendent, Rec. Pendent 5.6 Lead, Polyester, NiCoTef 155, 200
V2708 Pendent, Rec. Pendent 5.6 Lead, Polyester, NiCoTef, VC-250 155, 200
V3405 Pendent, Rec. Pendent 8.0 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286, 360
V3406 Pendent, Rec. Pendent 8.0 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286
V3405 Pendent, Rec. Pendent 8.0 Wax, wax over lead 155, 200
V3407 Pendent, Rec. Pendent 11.2 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286, 360
V3408 Pendent, Rec. Pendent 11.2 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286
V3407 Pendent, Rec. Pendent 11.2 Wax, wax over lead 155, 200
V2701 Upright 2.8 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286, 360
V2702 Upright 2.8 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286
V2703 Upright 5.6 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286, 360,
500
V2704 Upright 5.6 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286
V3401 Upright 8.0 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286, 360
V3403 Upright 11.2 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286
V3404 Upright 11.2 Lead, Polyester, NiCoTef, VC-250 135, 155, 175, 200, 286
V2705 Pendent 2.8 VC-250 135, 155, 175, 200, 286, 360,
500
V2701 Upright 2.8 VC-250 135, 155, 175, 200, 286, 360
https://iq.ulprospector.com/en/profile?e=160279 11/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
V2401 Upright 4.2 VC-250 135, 155, 175, 200, 286, 360
V2403 Pendent 4.2 VC-250 135, 155, 175, 200, 286, 360
V2759 Pendent 4.2 VC-250 135, 155, 175, 200, 286, 360,
500
V2760 Pendent 4.2 VC-250 135, 155, 175, 200, 286, 500
V3405 Pendent 8.0 VC-250 135, 155, 175, 200, 286, 360
V3401 Upright 8.0 VC-250 135, 155, 175, 200, 286, 360
V3415 HSW, Rec. HSW 8.0 VC-250 135, 155, 175, 200
V2723### Pendent 5.6 VC-250 135, 155, 175, 200, 286, 360,
500
V3419 Pendent 11.2 VC-250 135, 155, 175, 200, 286, 360
V2721 Upright 5.6 VC-250 135, 155, 175, 200, 286, 360,
500
V3417 Upright 8.0 VC-250 135, 155, 175, 200, 286, 360
V3505** Pendent/Rec.Pendent 5.6 Polyester, VC-250 135, 155, 175, 200, 286
V3506** Pendent/Rec.Pendent 5.6 Polyester, VC-250 135, 155, 175, 200, 286
V3509** HSW, Rec.HSW 5.6 Polyester, VC-250 135, 155, 175, 200, 286
V3510** HSW, Rec.HSW 5.6 Polyester, VC-250 135, 155, 175, 200, 286
https://iq.ulprospector.com/en/profile?e=160279 12/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
V2723### SR Pendent 5.6 135, 155, 175, 200, 286, 360, 500
V2721 SR Upright 5.6 135, 155, 175, 200, 286, 360, 500
https://iq.ulprospector.com/en/profile?e=160279 13/15
7/12/22, 12:14 PM VNIV.EX5170 - Sprinklers, Automatic and Open | UL Product iQ
+ The SIN V4601 is intended for use in accordance with NFPA 13, to protect single-, double-, and multiple-row rack storage (no open top
containers or solid shelves) and palletized and solid pile storage (no open top containers or solid shelves) of Class I-IV commodities encapsulated
or nonencapsulated and cartoned Group A unexpanded plastics when installed in accordance with the manufacturers installation instructions.
SPECIFIC-APPLICATION SPRINKLERS
Attic Sprinklers
SIN Response Fire Roof Pitch, Max Max Length, Min Flow Nom Temp
Type Risk in./in. Width, ft Rate, gpm K-Factor Rating, °F
ft
++ For protection of light hazard attic spaces of wood truss or open wood joist construction with saddle-type and hip-type roofs in buildings 24
to 72 ft. in width and not exceeding a protection area of 400 sq. ft. per sprinkler when installed in accordance with the Manufacturer's Installation
and Design Parameter Instructions.
$ For protection of light hazard attic spaces of wood truss or open wood joist construction with saddle-type and hip-type roofs in buildings 24 to
84 ft. in width and not exceeding a protection area of 400 sq. ft. per sprinkler when installed in accordance with the Manufacturer's Installation and
Design Parameter Instructions.
*As measured on the horizontal from the sprinkler location to the eave.
+ For use in light hazard flat concealed spaces incorporating noncombustible or wood truss construction. The Manufacturers Installation and
Design Parameter Instructions should be consulted for specific installation parameters, obstruction criteria and hydraulic design requirements.
++ For use in combustible solid wood and composite wood joist construction.
# Sprinklers may be with a 3/4 inch Grooved End Inlet to be integrated with the Model V9 Coupling Assembly.
## Sprinklers may be with a 1 inch Grooved End Inlet to be integrated with the Model V9 Coupling Assembly.
###Sprinklers may be with a 1/2 inch Grooved End Inlet to be integrated with the Model V9 Coupling Assembly.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL Solutions' Follow - Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL
Solutions' Follow - Up Service. Always look for the Mark on the product.
UL Solutions permits the reproduction of the material contained in Product iQ subject to the following conditions: 1. The Guide Information,
Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner,
without any manipulation of the data (or drawings). 2. The statement "Reprinted from Product iQ with permission from UL Solutions" must appear
adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "©2022 UL LLC."
https://iq.ulprospector.com/en/profile?e=160279 15/15