FAIR Form 3 Import Template - FAIR # 1003

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 9

Form 3 - Characteristic Accountability, Verification and Compatibility

8. Requirement
6. Reference Bubble 7. Characteristic
5. Char. No. Op # Description / Note
Location Number Designator Specification
text
1 1 Zone D-4 1 Minor Linear Dimension: I 10.4 +/- 0.2
2 1 Zone D-4 2 Minor Angle 90 +/- 0.5
2822283 1 Zone C-3 3 Minor Radius ISO2768_M (3 +/- )
2822284 1 Zone D-3 4 Critical Linear ISO2768_M 15 +/- 0.2
2822285 1 Zone D-3 5 Critical Linear 21.6 +0.1,-0.1
2822286 1 Zone D-3 6 Critical Linear 33.7 +0,-0.2
2822287 1 Zone C-3 7 Minor Angle 3.4 +/- 0.5
2822288 1 Zone C-3 8 Major Symmetry <= 0.2
2822289 1 Zone C-3 9 Major True Position 2x <= 0.1
2822290 1 Zone C-4 10 Minor Linear ISO2768_M 2x7.4 +/- 0.2
2822291 1 Zone C-4 11 Critical Linear 28.3 +/- 0.1
2822292 1 Zone C-4 12 Critical Linear 33.5 +/- 0.3
2822293 1 Zone C-4 13 Major Concentricity 2x <= 0.4
2822293
2822294 1 Zone D-3 14 Major Concentricity 2x <= 0.4
2822294
2822295 1 Zone D-3 15 Minor Diameter ISO 2768_ 6 +/- 0.1
2822295
2822296 1 Zone D-2 16 Critical Linear ISO 2768_M 15 +/- 0.2
2822297 1 Zone D-2 17 Critical Linear ISO 2768_M 26 +/- 0.1
2822297
2822298 1 Zone D-2 18 Minor Radius 2x 0.5 +/- 0.1
2822299 1 Zone D-2 19 Minor Radius 2x 3 +/- 0.1
2822299
2822300 1 Zone D-2 20 Minor Radius 2x 3 +/- 0.1
2822300
2822301 1 Zone D-2 21 Major Symmetry <= 0.2
2822302 1 Zone C-2 22 Critical Linear ISO 2768_M 10.2 +/- 0.2
2822303 1 Zone C-2 23 Minor Angle 20 +/- 0.5
2822304 1 Zone C-2 24 Critical Linear ISO 2768_M 10.25 +0.2,-0.1
2822305 1 Zone C-2 25 Minor Linear ISO 2768_M 9.4 +/- 0.2
2822306 1 Zone C-2 26 Minor Chamfer 4x 1 +/- 0.1
2822306
2822306
2822306
2822307 1 Zone C-2 26.1 Minor Angle 4x 45 +/- 0.5
2822307
2822307
2822307
2822308 1 Zone C-2 27 Minor Linear ISO 2768_M 21 +/- 0.1
2822308
2822309 1 Zone C-3 28 Critical True Position 4x <= 0.3
2822309
2822309
2822309
2822310 1 Zone C-2 29 Minor Radius 2x 1.5 +/- 0.1
2822310
2822311 1 Zone - C3 30 Reference Linear ISO 2768_M (12 +/- )
2822312 1 Zone - C3 31 Critical Linear ISO 2768_M 218 +/- 0.2
2822312
2822313 1 Zone - B4 32 Minor Linear ISO 2768_M 2.5 +/- 0.1
2822314 1 Zone - B3 33 Minor Linear ISO 2768_M 52 +/- 0.1
2822314
2822314
2822314
2822314
2822315 1 Zone - B3 34 Minor Linear ISO 2768_M 74.1 +/- 0.1
2822315
2822315
2822315
2822315
2822315
2822315
2822316 1 Zone - B4 35 Minor Linear ISO 2768_M 312 +/- 0.2
2822316
2822316
2822317 1 Zone - B4 36 Reference Linear ISO 2768_M (20.9 +/- )
2822318 1 Zone - B4 37 Minor Radius 2 +/- 0.1
2822319 1 Zone - B4 38 Minor Linear 1.1 +0.2,-0
2822320 1 Zone - B4 39 Minor Linear ISO 2768_M 8.4 +/- 0.2
2822321 1 Zone - B3 40 Minor Radius <= 0.3
2822322 1 Zone - A3 41 Minor Chamfer 0.3 +/- 0.1
2822323 1 Zone - A3 41.1 Minor Angle 45 +/- 0.5
2822324 1 Zone - B3 42 Reference Linear 0.8 +/- 0.1
2822325 1 Zone - B2 43 Minor Chamfer 0.5 +/- 0.1
2822326 1 Zone - B2 43.1 Minor Angle 45 +/- 0.5
2822327 1 Zone - A2 44 Minor Thread type: 1/4-28 UNF
2822328 1 Zone - A2 44.1 Minor Linear 9.45 +0,-1
2822329 1 Zone - A3 45 Minor Linear 9.45 +0,-0.1
2822330 1 Zone - A3 46 Minor Radius 2 +/- 0.1
2822331 1 Zone - B3 47 Minor Diameter ISO 2768_ 4 +/- 0.1
2822332 1 Zone - B2 48 Critical Diameter ISO 2768_ 6.1 +/- 0.2
2822333 1 Zone - C2 49 Minor Linear ISO 2768_M 2.5 +/- 0.1
2822334 1 Zone - B1 50 Minor Chamfer 0.5 +/- 0.1
2822335 1 Zone - B1 50.1 Minor Angle 45 +/- 0.5
2822336 1 Zone - C4 51 Critical Linear 3.05 +0.2,-0
2822337 1 Zone - C3 52 Minor Radius 2x 0.6 +/- 0.1
2822337
2822338 1 Zone - C3 53 Minor Diameter ISO 2768_ 2.4 +/- 0.1
2822339 1 Zone - B3 54 Minor Linear ISO 2768_M 1.2 +/- 0.1
2822340 1 Zone - B3 55 Minor Linear ISO 2768_M 3.16 +/- 0.1
2822341 1 Zone - B4 56 Critical Linear 3.55 +0.2,-0
2822342 1 Zone - C4 57 Minor Angle 90 +/- 0.33
2822343 1 Zone - C4 58 Minor Angle 60 +/- 0.33
2822344 1 Zone - B3 59 Minor Radius <= 0.3
2822345 1 Zone - B2 60 Minor Radius <= 0.3
2822346 1 Zone - C2 61 Major Perpendicularity <= 0.1
2822347 1 Zone - C2 62 Minor Linear ISO 2768_M 7.4 +/- 0.2
2822348 1 Zone - C2 63 Minor Chamfer 0.4 +/- 0.1
2822349 1 Zone - C2 63.1 Minor Angle 45 +/- 0.5
2822350 1 Zone - C2 64 Reference Linear ISO 2768_M (24 +/- )
2822351 1 Zone - C1 65 minor Thread type: 6-32 UNC 4x
2822351
2822351
2822351
and Compatibility Evaluation
8. Requirement 10. Designed/
11. Nonconformance
Unit of 9. Results Qualified Comments
GDT Callout Number
measurement Tooling
mm Vernier VC001
Deg IM-6225 8
mm VMM
mm IM-6225 8
mm IM-6225 8
mm IM-6225 8
Deg IM-6225 8
{»~_|.`2`|D_} mm IM-6225 8
{¿~_|.`1`|C_|B_} mm 2x
mm 2x
mm VMM
mm VMM
{µ~_|.`4`|C_} mm CMM 2x
CMM 2x
{µ~_|.`4`|E_} mm CMM 2x
CMM 2x
mm VMM 2x
VMM 2x
mm IM-6225
mm IM-6225 2x
IM-6225 2x
mm IM-6225 2x
mm IM-6225 2x
IM-6225 2x
mm IM-6225 2x
IM-6225 2x
{»~_|.`2`|D_} mm IM-6225
mm IM-6225
Deg IM-6225
mm IM-6225
mm Height Gage
mm IM-6225 4x
IM-6225 4x
IM-6225 4x
IM-6225 4x
Deg IM-6225 4x
IM-6225 4x
IM-6225 4x
IM-6225 4x
mm Height Gage 2x
Height Gage 2x
{¿~_|.`3`|D_|B_|Amm CMM 4x
CMM 4x
CMM 4x
CMM 4x
mm IM-6225 2x
IM-6225 2x
mm
mm IM-6225 2x
IM-6225 2x
mm Caliper
mm Vernier VC001 x5
Vernier VC001 x5
Vernier VC001 x5
Vernier VC001 x5
Vernier VC001 x5
mm Vernier VC001 x7
Vernier VC001 x7
Vernier VC001 x7
Vernier VC001 x7
Vernier VC001 x7
Vernier VC001 x7
Vernier VC001 x7
mm Vernier VC001 3x
Vernier VC001 3x
Vernier VC001 3x
mm
mm
mm Vernier VC001
mm Height Gage
mm IM-6225
mm IM-6225
deg IM-6225
mm
mm
deg IM-6225
Thread gauge
mm
mm
mm IM-6225
mm VMM
mm VMM
mm Vernier VC001
mm
deg IM-6225
mm
mm IM-6225 2x
IM-6225 2x
mm VMM
mm
mm
mm
deg IM-6225
deg IM-6225
mm IM-6225
mm IM-6225
{¼~_|0`.`1`|B_} mm CMM
mm Vernier VC001
mm
deg IM-6225
mm
Thread gauge 4x
Thread gauge 4x
Thread gauge 4x
Thread gauge 4x
12. Additional Data/Comments Enter the names of up to four additional
Inspection fields at the top of each column to the
Inspector Tool ID left.
Method

8. Requirement
Enter Text, Specification &
Requirements, or both.
Text: Enter the text of a drawing note,
or optionally, a brief description of the
feature
Specification and Tolerances: Enter the
characteristic data in one of the
following formats:

Equal Tolerances
0.020 +/- 0.01 or
0.020 ± 0.01
Unequal Tolerances
0.020 +0.01,-0.02 or
0.020 +0.01/-0.02
Range
0.019 - 0.021 or
0.021 - 0.019
Maximum
<= .020
< .020 or
.020 MAX or
MAX .020
Minimum
>= .020
> .020 or
.020 MIN or
MIN .020
Basic or Reference Dimension
0.020 or
(0.020) or
[0.020]

9. Results
Variable: Enter any number
Attribute: Enter "Pass" or "Fail"
Not Reportable: Enter "NA" or "NR"
Separate multiple results for a single
characteristic with semicolons
Separate multiple results for a single
characteristic with semicolons
e.g., 0.019; 0.021; 0.020; 0.019

You might also like