2 www.jubhome.eu www.jubhome.eu 3
2 Why choose JUBHome 3 From plan to construction
WALL? with JUBHome WALL
1. The architectural plan: Based on the received plans, the customer, the designer, and JUBHome's
quick and easy construction on the basis of the freely available assembly plan of the structural technical support service will agree about the very small adjustments in the dimensions of the structure
elements and a "Lego brick" based stacking system; which are needed in order to achieve the modular grids and details as defined in the JUBHome system.
pouring of concrete without shuttering;
simpler reinforcing without steel-fixing, by means of polypropylene ties and holders;
for energy-efficient buildings in all climate zones (the thermal transmittance of the walls ranges from
0, 13 down to 0. 08 W/m2K);
heat accumulation in the reinforced-concrete core and a decremental delay in heat transfer through
the walls;
an uninterrupted thermally-insulating and waterproofing envelope, which reduces to the minimum
the effect of thermal bridges;
if the concrete is correctly placed, a high degree of air-tightness can be achieved; 2. The 3D model: After the dimensions have been fully agreed, JUBHome's technical support service will
one of the few ICF systems suitable for the construction of buildings in earthquake-prone regions, prepare a graphic representation of the whole building as a 3D model, showing all the constituent typical
which is proved by the results of tests performed at the Institute of Structural Engineering, Earthquake and non-typical (cut and glued) elements.
Engineering and Construction IT, Faculty of Civil and Geodetic Engineering, University of Ljubljana,
Ljubljana, Slovenia (IKPIR FGG);
rapid recovery in the case of flood damage (the EPS has a low water absorption coefficient);
several working phases can be combined into just one – the thermally insulating part of the structure
simultaneously serves as formwork for the placing of concrete, and as a substrate for the application
of finishing layers;
finishing of inner walls with a thin layer of mortar and smoothing with a levelling compound;
an additional area equal to up to 5% per storey can be saved if compared with walls with similar 3. The assembly plan: For use at the building-site, an assembly plan will be developed from the 3D model
insulating properties built according to traditional construction methods; showing individual walls, with the positions of the elements and their specifications.
only one basic layer of plaster with a reinforcing mesh, together with the final layer of the selected
façade system, needs to be applied to the façade walls;
no in situ cutting of elements, and a zero-waste production site, recycling is performed at the
production plant;
technical advice is available free of charge during both the design and the construction stages.
4. Construction: After the non-typical elements have been manufactured, all the elements needed for the
construction of an individual building are assembled, wrapped in foil, and put on palettes, and delivered to
the building-site, where work can then begin.
4 www.jubhome.eu www.jubhome.eu 5
4 JUB Home WALL
elementi
WALL LINEAR 465 I 075 WALL LINEAR 465 I 150 WALL LINEAR 465 I 300
Taking into account the required energy efficiency level, wall elements with any of three different
thicknesses can be selected for the construction of the façade walls.
Thickness of the
31 cm 40 cm 47,5 cm 53,5 cm Technical code Length »L« (mm) Width (mm) Height (mm)
completed wall**
Thermal WALL-CORNER (300-L-525) 525 300 364
0,204 W/m2K 0,130 W/m2K 0,099 W/m2K 0,084 W/m2K
transmittance (U)
WALL-CORNER_OUT (390-LZ-615) 615 390 364
WALL-CORNER_OUT (465-LZ-690) 690 465 364
* This is a JUBHome recommendation. In order to obtain exact figures about the energy efficiency of an actual building at a defined WALL-CORNER_OUT (525-LZ-750) 750 525 364
location it is necessary to perform calculations which are in accordance with the presently valid legislation. WALL-CORNER (300-L-375) 375 300 364
** The indicated thicknesses take into account the basic renders and final layers.
WALL-CORNER_OUT (390-LZ-465) 465 390 364
WALL-CORNER_OUT (465-LZ-540) 540 465 364
WALL CORNER IN 465 LN 675 WALL CORNER OUT 465 LN 690 WALL CORNER OUT 465 LZ 540 WALL CORNER IN 465 LN 525
6 www.jubhome.eu www.jubhome.eu 7
Junction elements (WALL-T-JUNCTION) Additional elements (WALL CUT/ADD/COVER and END)
Like the corner elements, the T-junction elements, too, have two different lengths, so that a normal masonry WALL CUT elements are used in those cases where it is necessary to tailor the basic elements in order to take
bond can be maintained by height. The splitting-off parts of these elements are used to form connecti- into account the geometry of the building. In the case of such elements the PP ties are replaced by softer
ons with the internal load-carrying walls, and have a width of 300 mm. Towards the inside of the elements, EPS ties, which can be tailored into shape using ordinary saws for the sawing of timber. They are most
at their ends, these elements, too, have two pairs of vertical keyway joints for the positioning of closing frequently used as the top courses of gable walls.
elements. WALL ADD height-increasing elements are used make corrections to the height of walls in those cases when
the clear storey height is not equal to a multiple of the height of the linear elements. They can also be
Technical code Length »L« (mm) Width (mm) Height (mm)
used to adjust the height of parapet walls for windows. These elements make use of reduced-height PP
WALL-T_JUNCTION (300-T-“L”) 450/750 300 364 ties which, however, are sufficient for the fixing of the horizontal reinforcement bars. The length of these
elements is the same for all wall thicknesses. If shorter elements are needed then they are prepared in the
WALL-T_JUNCTION (390-T-“L”) 450/750 390 364
production plant, based on the corresponding assembly drawing.
WALL-T_JUNCTION (465-T-“L”) 450/750 465 364
WALL COVER covering elements are used to cover parapet walls and gable walls. They are glued onto the
WALL-T_JUNCTION (525-T-“L”) 450/750 525 364 previous, i.e. next lower course of wall elements by means of JUBOFLEX MS adhesive, if such gluing is
necessary. Their length is uniform for walls of all thicknesses.
The purpose of the WALL END closing element is to close walls next to the reveals of windows and doors,
and at the ends of walls. Making use of vertical keyway joints, these elements are pushed down into the
ends of the linear elements.
WALL CUT 465 IC 900 WALL ADD 465 IR 900 WALL COVER 465 IT 900
WALL RING 465 V 900 WALL RING 465 V 600 WALL RING 465 V 300 WALL RING 465 V 150
8 www.jubhome.eu www.jubhome.eu 9
Lintel elements (WALL LINTEL)
In the case of the lintel elements (see Figure 10), except in the case of a wall thickness of 300 mm, there is
5 Basic guidelines for the
a difference between the right-hand part and the left-hand part of the element. The wall elements with
thicknesses of 300 or 390 mm have a uniform length of 675 mm, whereas those with thicknesses of 465 or
525 mm have a uniform length of 900 mm. Next to the bearing areas these elements have grooves which
design of JUBHome WALL
are for the lower wall elements with a length of 150 mm. In the area of the concrete core the bearing areas
are shortened so that they are aligned with the plane of the closing element of the lower opening. Here
they have a common length of 60 mm. Taking into account the provisions of the assembly plan, these
elements
elements are cut and glued in the production plant so that they have the necessary design length.
The floor-plan grid layout of JUBHome WALL elements is orthogonal, with increments of 7.5 cm in both
Technical code Length »L« (mm) Width (mm) Height (mm) directions. All inter-connected walls made of JUBHome WALL elements have to be designed taking into
account this grid layout. When measuring distances between external and internal walls, the clear distan-
WALL-LINTEL_LEFT (390-PL-675) 675 390 364 ces between these walls need to be taken into account. All openings (i.e. doors and windows) located
WALL-LINTEL_LEFT (465-PL-900) 900 465 364 along walls must be located in such a way that the above-mentioned grid layout, with increments of 7.5
WALL-LINTEL_LEFT (525-PL-900) 900 525 364
cm, is taken into account.
WALL-LINTEL (300-P-675) 675 300 364 The height of the basic ("linear") wall elements, and thus also of individual horizontal courses of the walls,
WALL-LINTEL_RIGHT (390-PD-675) 675 390 364 amounts to 36.4 cm. In the case when the storey height is not equal to a multiple of the height of the basic
wall element, then special "height-increasing elements", which can provide the extra needed height, can
WALL-LINTEL_RIGHT (465-PD-900) 900 465 364
be used. They have a height equal to one quarter of the height of the basic wall element, i.e. 9.1 cm. The
WALL-LINTEL_RIGHT (525-PD-900) 900 525 364 recommended clear structural height of individual storeys is equal to the height of 8 courses of basic wall
elements. Due to the permissible unevenness of the floor slab, in the design an extra 1.0 cm of height is
taken into account, which is located beneath the first course of wall elements. This results in a clear struc-
tural storey height of 292,2 cm, measured between the two reinforced concrete slabs. In the case that the
floor structure above the RC slab has a height of 15 cm, and the suspended ceiling has a thickness of 16
cm, then a clear storey height of 261,2 cm is obtained. The inter-storey floor slabs can have any selected
thickness since the ring elements can be cut to the desired height.
10 www.jubhome.eu www.jubhome.eu 11
metal braces are erected, at maximum centre-to-centre distances
Instructions for the of 1.2 m. They are fixed to the base slab by means of screwed
anchors, to the wall elements by means of Spax screws. Concrete
12 www.jubhome.eu www.jubhome.eu 13
7 Additional equipment and 8 Why is EPS a good choice for
aids for construction the insulation of houses?
with JUBHome WALL In the construction of passive and low-energy buildings, we are faced with the question of which type of ther-
mal insulation to choose. So why choose EPS?
used to manufacture many other products, e.g. as filler material in pillows for babies;
Protective metal sheeting is used to prevent the ingress of cement EPS has the best price / thermal insulation ratio of all insulation materials which are on the market.
laitance onto the connecting button-profiled surfaces during the
first and second stages of the concreting works. This sheeting is In general, the EPS has excellent thermal insulation properties, excellent mechanical characteristics, very low
available in four different covering widths which correspond to water absorption, optimum vapor permeability, and a very low environmental footprint. Due to its relatively low
the widths of the façade and internal layers of the EPS of the wall water absorption coefficient, even in the presence in a humid or wet environment, EPS's thermal insulation pro-
elements. They are placed on the top of the wall before the conc- perties practically do not change, while simultaneously remaining dimensionally stable and not decomposing.
reting works are begun, either with overlapping or not. They can Contact façade systems made of EPS have more suitable vapor permeability compared to diffusion open sy-
either be placed along the whole length of the wall or they can be stems where the possibility of condensation occurring within the façade system is greater. Another misunder-
moved during the concreting works. It is also possible to use other standing is associated with vapor permeability, i.e. the "breathing" of walls when EPS is used as an isolation ma-
methods of protection of the contact surfaces, e.g. with the use of terial. Air in a room is not exchanged through the facade, but mostly at leaky locations, by the opening windows
cardboard, tarpaulins, or PE sheeting. and doors, or by forced ventilation. The phenomenon of wall breathing was rejected as early as in 1923, when
the physicist Erwin Raisch proved, over one hour 50 times more air passed through a door lock than through a
Holders for the positioning of vertical 1.0 m2 of wall.
reinforcement 120
120
70
are fixed at the top of each course of wall elements in specially 80
XPS
60 50 Les - smreka
provided grooves, at those locations where, according to the rein- 40 Les - hrast
40
forcement plans, the vertical reinforcing bars are to be positioned. 30 Fenolne plošče
EPS
20
The purpose of the holders is to provide for the positioning of ver- 0
tical reinforcing bars with diameters of up to 12 mm at selected
centre-to-centre distances which are a multiple of the modular di- Koeficient difuzijske upornosti vodni pari (µ)
14 www.jubhome.eu www.jubhome.eu 15
9 Technical data of JUBHome 10 What your JUBHome WALL
WALL elements offer contains
Permissible deviations from the nominal dimensions of the wall elements Preparation of our offer:
Length Width Height (mm)
The JUBHome technical service will, at your request, prepare an offer for each building separately. For this ple-
L W T ase:
SIST EN 822 SIST EN 822 SIST EN 823
±2 ±2 ±1
1) supply your architectural plan and contact details,
2) state which wall thickness you have chosen.
Please send these details to info@jubhome.eu, and we will send you an informative offer within 5 days.
Dimensional stability of the wall elements
Dimensional stability at defined temperature and humidity Dimensional stability at defined temperature and
conditions T=+20 °C, RH = 50 % humidity conditions T=+70 °C in RH = 50 %
Prices from the JUBHome WALL offer will include:
DS(N) DS(70,-)
SIST EN 1603 SIST EN 1604 an assembly plan of the JUBHome WALL elements
±0,5 ±1 free delivery to your building-site in the case of orders worth more than 1500€
±0,5 ±1
technical support, at no charge:
to investors and independent house builders:
Strength and other building-physics characteristics of the EPS material and the PP ties
advice;
Description Designation Standard Value instructions for the performance of works.
16 www.jubhome.eu www.jubhome.eu 17
... Notes ... Notes
18 www.jubhome.eu www.jubhome.eu 19
JUBHome Systems:
JUBHome BASE – Load-bearing thermal insulation for foundation slabs
Thermal losses through the ground are reduced, U = 0,2 – 0,11 W/m2K, thermal bridges are
prevented.;
By choosing elements of suitable thickness, suitable for low-energy and passive or nearly
zeroenergy houses;
For all types of structural systems - ICF, masonry, prefabricated, timber framed;
No shuttering is needed for the construction of the concrete foundation slab.
External waterproofing provides complete protection from ground moisture and ground water
under pressure
Buildings can be founded not only in seismically active regions but also on ground with lower
bearing capacity
JUBHome FLOOR – Thermally insulating formwork for flat and sloping RC slabs
Simple execution of an unheated basement beneath a heated ground floor.
Rapid and precise placing of concrete in the ribbed inter-storey slabs, without formwork.
Lost shuttering and at the same time additional thermal insulation of flat and sloping RC roofs.
A less complex support system is needed for the execution of thermally-insulating ribbed inter-storey slabs.
JUBHome d.o.o.