Construction of Community Hall Compound Wall at Harizanawada of - 104023

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Construction of Community Hall Compound Wall at Harizanawada of

Gangavaram GP.Kovur (M).

 Agar holes details :-


o Depth of agar hole - 2.47 mts.(8ft)
o Dia. Of agar hole - 300 mm. (1ft)
o Steel details:-
 12mm rods – 4nos
 8mm rings – 6 inch c/c.

 PCC under plinth beam :- L B D


72 mts 0.45 mts 0.1mts

 Plinth Beam Details:-


L B D

71.55 mts 0.30 mts 0.23mts

o At Column ‘G’ Plinth Beam support footing of size : 0.6m*0.6m*0.3m.


o Steel Details :-
 12mm rods :- Top – 2 Nos , Bottom – 3 Nos
 8mm rings - 6 inch c/c..

 Brick work under plinth beam From F to G of thickness 0.380mts

2.20 m

0.80m 2.34 m
 Columns Details
S.No Columns Name L (mts) B (mts) D (mts)
1. Column – A 1.36 0.230 0.230
2. Column – B 1.27 0.230 0.230
3. Column – C 1.24 0.230 0.230 (gate)
4. Column – D 1.23 0.230 0.230 (gate)
5. Column – E 1.25 0.230 0.230 (gate)
6. Column – F 1.32 0.230 0.230 (gate)
7. Column – G 2.08 0.230 0.230
8. Column – H 2.12 0.230 0.230
9. Column – I 2.05 0.230 0.230
10. Column – J 1.96 0.230 0.230
11. Column – K 1.95 0.230 0.230
12. Column – L 1.90 0.230 0.230
13. Column – M 1.85 0.230 0.230
14. Column – N 1.82 0.230 0.230
15. Column – O 1.53 0.230 0.230
16. Column – P 1.50 0.230 0.230
17. Column – Q 1.45 0.230 0.230
18. Column – R 1.40 0.230 0.230
19. Column – S 1.35 0.230 0.230
20. Column – T 1.20 0.230 0.230
21. Column – U 1.22 0.230 0.230
22. Column – V 1.22 0.230 0.230
23. Column – W 1.22 0.230 0.230
24. Column – X 1.22 0.230 0.230
25. Column – Y 1.22 0.230 0.230
26. Column – Z 1.28 0.230 0.230

o Column steel details :-


 12mm rods - 4 nos
 8mm rods - 6 inch c/c

 Consolidated plinth beam at intermediated level at only NORTH side wall.


o RCC Beam - 21.22mts * 0.230mts * 0.100mts.
o 8mm rods - 2 nos of 21.22 rmts.
 Brick work Details :-
Red Country brick of nominal size used.

S.no Columns__to__ Wall Height at Wall Height at Length of span


1. A to B 1.36 1.27 1.87 mts
2. B to C 1.27 1.24 2.01 mts
3. C to D 1.24 1.23 1.20 mts (gate)
4. D to E 1.23 1.25 2.40 mts (gate)
5. E to F 1.25 1.32 3.01 mts (gate)
6. F to G 1.32 2.08 2.51 mts (gate)
7. G to H 2.08 2.12 2.26 mts
8. H to I 2.12 2.05 2.62mts
9. I to J 2.05 1.96 2.56 mts
10. J to K 1.96 1.95 2.06 mts
11. K to L 1.95 1.90 1.90 mts
12. L to M 1.90 1.85 2.53mts
13. M to N 1.85 1.82 2.58mts
14. N to O 1.82 1.53 2.60mts
15. O to P 1.53 1.50 2.97 mts
16. P to Q 1.50 1.45 2.90 mts
17. Q to R 1.45 1.40 2.48 mts
18. R to S 1.40 1.35 2.53 mts
19. S to T 1.35 1.20 2.66 mts
20. T to U 1.20 1.22 2.60 mts
21. U to V 1.22 1.22 2.48 mts
22. V to W 1.22 1.22 2.48 mts
23. W to X 1.22 1.22 2.62mts
24. X to Y 1.22 1.22 2.51mts
25. Y to Z 1.22 1.28 2.71mts
26. Z to A 1.28 1.36 3.44mts

 Gate Coloumns brick work :


o C : 1.24m *0.380m * 0.380m E : 1.25m *0.380m * 0.380m
o D : 1.23m * 0.380m * 0.380m F : 1.32m *0.380m * 0.380m

You might also like