Professional Documents
Culture Documents
Mat in Staad
Mat in Staad
Mat in Staad
Load Details
Included Loads
Due to the large amount of load case data, it is not being included in the calculation report. Please export the load data to a spreadsheet using the "Export to
Spreadsheet" option.
Load Combinations
Thickness
Region Material Unit Weight
(m)
2 0.25 Concrete 24.00 kN/m3
Soil Details
Mat Geometry
Boundary Name : 2
Node No X Coor(m) Y Coor(m) Z Coor(m)
5 50.70 0.00 3.50
6 53.70 0.00 3.50
7 53.70 0.00 96.25
8 50.70 0.00 96.25
Analysis Results
Rx Ry Rz
- Node Number Load Case Dx(mm) Dy(mm) Dz(mm)
(Rad) (Rad) (Rad)
Max SQX 1502 105 479.19 433.64 0.00 0.00 0.00 28.92 34.52 -1.73
Max SQY 1598 105 -471.96 490.95 0.00 0.00 0.00 29.48 33.65 1.37
Max SX 1 102 3.73 4.59 0.00 0.00 0.00 0.44 0.46 -0.31
Max SY 1 102 3.73 4.59 0.00 0.00 0.00 0.44 0.46 -0.31
Max SXY 1 102 3.73 4.59 0.00 0.00 0.00 0.44 0.46 -0.31
Max MX 1812 105 -490.26 446.15 0.00 0.00 0.00 29.82 34.76 1.33
Max MY 1812 105 -490.26 446.15 0.00 0.00 0.00 29.82 34.76 1.33
Max MXY 980 105 112.82 -112.85 0.00 0.00 0.00 10.69 16.39 5.67
Min SQX 1625 105 -490.51 276.75 0.00 0.00 0.00 29.81 34.71 0.85
Min SQY 1813 105 -473.19 -491.90 0.00 0.00 0.00 29.51 33.77 -1.38
Min SX 1 102 3.73 4.59 0.00 0.00 0.00 0.44 0.46 -0.31
Min SY 1 102 3.73 4.59 0.00 0.00 0.00 0.44 0.46 -0.31
Min SXY 1 102 3.73 4.59 0.00 0.00 0.00 0.44 0.46 -0.31
Min MX 262 105 10.19 -6.04 0.00 0.00 0.00 -0.20 13.60 -0.80
Min MY 1848 105 -0.90 7.02 0.00 0.00 0.00 2.58 -9.47 0.11
Min MXY 1191 105 113.03 113.35 0.00 0.00 0.00 10.72 16.43 -5.69
Base Pressure
- Node X-Coor(m) Y-Coor(m) Z-Coor(m) Load Case
(kN/m2)
Maximum Base
1818 52.20 0.00 17.86 105 26.51
Pressure
Minimum Base
124 53.70 0.00 78.00 105 5.70
Pressure
Load Case Area in Contact(m2) % of Total Area Area out of Contact(m2) % of Total Area
102 278.25 100.00 0.00 0.00
105 278.25 100.00 0.00 0.00
108 278.25 100.00 0.00 0.00
111 278.25 100.00 0.00 0.00
114 278.25 100.00 0.00 0.00
117 278.25 100.00 0.00 0.00
120 278.25 100.00 0.00 0.00
123 278.25 100.00 0.00 0.00
126 278.25 100.00 0.00 0.00
129 278.25 100.00 0.00 0.00
132 278.25 100.00 0.00 0.00
135 278.25 100.00 0.00 0.00
138 278.25 100.00 0.00 0.00
141 278.25 100.00 0.00 0.00
144 278.25 100.00 0.00 0.00
147 278.25 100.00 0.00 0.00
150 278.25 100.00 0.00 0.00
153 278.25 100.00 0.00 0.00
156 278.25 100.00 0.00 0.00
Overturning Check
X Coordinate Z Coordinate
of Critical of Critical Overturning Overturning Resisting Resisting FOS(x) FOS(z)
Load Case
Edge for OT Edge for OT Moment, Mx Moment, Mz Moment, Rx Moment, Rz (About X (About Z
No
About Z About X (kNm) (kNm) (kNm) (kNm) Direction) Direction)
(m) (m)
102 50.70 3.50 -1095.66 19.98 193495.05 -6258.60 176.60 313.27
105 50.70 3.50 -1307.01 24.02 216229.62 -6993.95 165.44 291.13
108 50.70 3.50 -736.54 19.75 203612.04 -6585.83 276.45 333.52
111 50.70 3.50 -737.15 18.78 203374.45 -6578.15 275.89 350.33
114 50.70 3.50 -734.54 20.92 204020.31 -6599.04 277.75 315.46
117 50.70 3.50 -894.73 17.54 184989.90 -5983.50 206.75 341.11
120 50.70 3.50 -896.01 15.60 184514.67 -5968.13 205.93 382.52
123 50.70 3.50 -890.75 19.89 185806.46 -6009.91 208.60 302.22
126 50.70 3.50 -917.92 11.84 175663.33 -5681.83 191.37 479.82
129 50.70 3.50 -960.34 22.41 178162.09 -5762.65 185.52 257.18
132 50.70 3.50 -897.16 17.30 176946.22 -5723.33 197.23 330.78
135 50.70 3.50 -981.08 16.95 176879.16 -5721.16 180.29 337.61
138 50.70 3.50 -726.78 12.37 151723.59 -4907.50 208.76 396.85
141 50.70 3.50 -728.01 10.43 151248.38 -4892.13 207.76 469.17
144 50.70 3.50 -722.77 14.71 152540.11 -4933.91 211.05 335.40
147 50.70 3.50 -683.15 7.56 150789.90 -4877.30 220.73 645.11
150 50.70 3.50 -725.56 18.13 153288.58 -4958.12 211.27 273.54
153 50.70 3.50 -662.39 13.02 152072.78 -4918.80 229.58 377.75
156 50.70 3.50 -746.32 12.66 152005.75 -4916.63 203.67 388.21
Punching shear check has been performed based on the assumption that the full perimeter shaped like a rectangle is effective for all columns. This assumption may not be valid for
columns close to the edge of the mats or openings. Users are advised to verify the correctness of the perimeter for such cases. This will be addressed in a future release.
Column No. Load Case Punching shear capacity (kN/m2) Punching Perimeter (m) Maximum Corner Stress (kN/m2) Design Status
1814 114 1473.72 1.47 562.83 Pass
1816 105 1473.72 1.47 529.61 Pass
1818 105 1473.72 1.47 568.73 Pass
1820 105 1473.72 1.47 790.64 Pass
1824 105 1473.72 1.47 791.63 Pass
1826 105 1473.72 1.47 569.29 Pass
1828 105 1473.72 1.47 535.80 Pass
1830 105 1473.72 1.47 553.81 Pass
1832 105 1473.72 1.47 547.46 Pass
1834 105 1473.72 1.47 551.03 Pass