Issue:
How to reset the NetBotz NBRK0750 or NBWL0755
Product Line
NetBotz 700 Series
- NetBotz Wall Monitor 755 (NBWL0755 / NBWL0756)
- NetBotz Rack Monitor 750 (NBRK0750)
Environment
NetBotz 700 Series (all versions)
Environment:
NetBotz Version 7.xx appliances
Cause:
If the NetBotz appliance becomes inaccessible via the web and can not be accessed or if there appears to be
corruption which you feel could be resolved by a full reset of the appliance, follow the below procedure.
A 503 error may occur after the initial upgrade if this process is not followed as well. If a 503 error is seen when
attempting web access, please see the resolution below.
Resolution:
NOTE If you have any Camera Pod 165 devices connected to the Private LAN of a NetBotz 7xx series appliance,
it is advised to remove them prior to resetting the appliance. (Note, the NetBotz 755 camera pod is attached by a
screw in the back and is removable.)
If not than it may be necessary to delete/reset the camera in the 700 series appliance. In DEVICES > you may see
the camera pod with status Not Authorized. Delete the device, then reset the camera pod by pressing the small
square reset button on the lower left side. (facing) for at least 20-30 seconds. The camera pod should then auto
negotiate to the appliance. If the Camera Pod is not directly connected to the appliance, follow the instructions in
the NetBotz Camera Pod 165 Installation and Quick Start Guide. https://download.schneider-electric.com
/files?p_Doc_Ref=990-5974&p_enDocType=Quick+start+guide&p_File_Name=990-5974B_EN.pdf
This procedure removes all user configuration from the appliance. If you can access the NetBotz appliance via
1 of 4 7/3/2023, 2:23 PM
Netbotz 700 Series | How can I reset the NetBotz 750 to defaults? | APC... https://www.apc.com/sk/en/faqs/FA370681/
SSH, connect using a utility such as putty.exe and when prompted, log in using root and the password you had
provided upon initial root login (done via serial connection).
If you can not access through SSH, connect using the micro USB serial configuration cable. Once connected,
verify you're using the correct port in device manager, then use the following settings and connect with a terminal
emulation program such as Hyper-terminal or Putty:
115,200 Baud rate
8 Data Bits
No Parity
1 Stop Bit
No Flow control.
Open the connection and hit enter until prompted for a login.
Log in using root and the password you had provided upon initial root login (done via serial connection), then
when prompted to press enter within 5 seconds, type a capital X and hit Enter.
/netbotz_app/reset.sh
As of version 5.2.1, this command has changed to:
/netbotz_app/factory_reset.sh
If you wish to reset the database but not reset IP info or other configuration, type:
/netbotz_app/restart.sh stop cleanDB startApp startClubber
2 of 4 7/3/2023, 2:23 PM
Netbotz 700 Series | How can I reset the NetBotz 750 to defaults? | APC... https://www.apc.com/sk/en/faqs/FA370681/
SUBSCRIBE TO EMAIL:
Get monthly updates from Schneider Electric delivered right to your inbox.
I'd like to receive news and commercial info from Schneider Electric and its affiliates via
electronic communication means such as email, and I agree to the collection of information on
the opening and clicks on these emails (using invisible pixels in the images), to measure
performance of our communications and improve them. For more details, please read our
Privacy Policy.
3 of 4 7/3/2023, 2:23 PM
Netbotz 700 Series | How can I reset the NetBotz 750 to defaults? | APC... https://www.apc.com/sk/en/faqs/FA370681/
I am a...
Subscrib…
WHO WE ARE
CONNECT WITH US
4 of 4 7/3/2023, 2:23 PM