12.0 PSV Calibration Procedure
12.0 PSV Calibration Procedure
12.0 PSV Calibration Procedure
No: INST-SOP-02
Rev: 0
PSV CALIBRATION PROCEDURE Date: 14-01-2020
(ISO 17025:2017) Approved by: Kenneth Ilouno
INSTRUTECH LIMITED
CONTROLLED COPY
1
PSV CALIBRATION
REVISION (ISO 17025:2017)
AND AUTHORISATION RECORD
REVISION: 3
INST-SOP-02
PREPARED REVIEWED APPROVED
BY BY BY
NAME EMMANUEL TORKA ILOUNO
UYAELUMUO CLEMENT KENNETH
SIGNATURE
DATE
This document belongs to Instrutech Limited. No corrections / amendments are to be made except by written authorization of the
Management.
1
Doc. No: INST-SOP-02
Rev: 0
PSV CALIBRATION PROCEDURE Date: 14-01-2020
(ISO 17025:2017) Approved by: Kenneth Ilouno
INSTRUTECH LIMITED
CONTROLLED COPY
AMENDMENT PAGE
2
Doc. No: INST-SOP-02
Rev: 0
PSV CALIBRATION PROCEDURE Date: 14-01-2020
(ISO 17025:2017) Approved by: Kenneth Ilouno
INSTRUTECH LIMITED
CONTROLLED COPY
TABLE OF CONTENTS
S/N DESCRIPTION PAGE
1.0 ABBREVIATIONS
2.0 PURPOSE
3.0 SCOPE
4.0 REFERENECE DOCUMENT
5.0 TEST EQUIPMENTs
6.0 SAFETY
7.0 PROCEDURE
7.1 SYSTEM OF IMPLEMENTATION
7.2 REVISION
7.3 DISTRIBUTION
8.0 APPENDIX
3
Doc. No: INST-SOP-02
Rev: 0
PSV CALIBRATION PROCEDURE Date: 14-01-2020
(ISO 17025:2017) Approved by: Kenneth Ilouno
INSTRUTECH LIMITED
CONTROLLED COPY
1.0 Purpose
The purpose of this procedure is to provide guidelines for carrying
out calibration and certification of PSV for SPDC/SAIPEM.
.
The reason for the guidelines is to emphasis the method/ steps to
be followed during calibration and certification of this equipment.
2.0 Scope:
4
Doc. No: INST-SOP-02
Rev: 0
PSV CALIBRATION PROCEDURE Date: 14-01-2020
(ISO 17025:2017) Approved by: Kenneth Ilouno
INSTRUTECH LIMITED
CONTROLLED COPY
Considering the inherent dangers involved with this job, safety shall
be the major concern. The following steps in addition to the clients
procedures shall be followed..
Only personnel directly involved with the job shall be
allowed in the job area
An experienced Safety Officer will be available to ensure
safety at all times during pressure testing.
Ensure that a JHA has been prepared and is explained and
clearly understood by all parties involved in the work.
Check ALL personnel involved in the test have correct PPE
Activities of personnel performing this work should be carried
out within a well-established and management approved
framework. The frame work should be based on both
SPDC/SAIPEM and INSTRUTECH instructions and should
contain the following:
5
Doc. No: INST-SOP-02
Rev: 0
PSV CALIBRATION PROCEDURE Date: 14-01-2020
(ISO 17025:2017) Approved by: Kenneth Ilouno
INSTRUTECH LIMITED
CONTROLLED COPY
6
Doc. No: INST-SOP-02
Rev: 0
PSV CALIBRATION PROCEDURE Date: 14-01-2020
(ISO 17025:2017) Approved by: Kenneth Ilouno
INSTRUTECH LIMITED
CONTROLLED COPY
Calibration number
Clients name
Calibration date
Due date
Tractability
Ambient Temperature
Set pressure
Relative humidity
Method of calibration
Manufacturer of the PRV
Service
Equipment name
Part number/model number
Tag number
Serial number
7
Doc. No: INST-SOP-02
Rev: 0
PSV CALIBRATION PROCEDURE Date: 14-01-2020
(ISO 17025:2017) Approved by: Kenneth Ilouno
INSTRUTECH LIMITED
CONTROLLED COPY
SUGGESTION/CONCLUSION
If the PRV does not respond at all adjustments, both clockwise and anticlockwise
adjustments, then, its either the seat is pitted or the spring has lost its elasticity.
Any of these parts could be replaced.
8
Doc. No: INST-SOP-02
Rev: 0
PSV CALIBRATION PROCEDURE Date: 14-01-2020
(ISO 17025:2017) Approved by: Kenneth Ilouno
INSTRUTECH LIMITED
CONTROLLED COPY
5.3 Revision
The procedure can be revised by the Quality Manager upon
warranted request of any member of the staff.
5.4 Distribution
SPDC/SAIPEM Project Manager, QA Department and Work Site.
6.0 APPENDIX
Appendix 1: Typical calibration certificate