Professional Documents
Culture Documents
Summer Experience vSAN 101 Maurice
Summer Experience vSAN 101 Maurice
Summer Experience vSAN 101 Maurice
VMware
2019
Confidential
VMware │ ©2018
Confidential VMware,
Internal Inc.
Use Only. 3
In 2013
Public Cloud
Elastic Workloads
Flexible resources in the public cloud 25%
Predictable Workloads
75% Lower costs with private cloud infrastructure
HAVE A HYBRID
CLOUD STRATEGY
80%
End-User Computing
Applications
Cloud Management
Lifecycle Automation
SDDC Manager
Operations Automation
Compute Storage
Cloud Agnostic & Policy
Network
Based Security
Compute
Storage
Cloud Foundation
Network
Management
Patching
and Upgrades
Policy Based
vSphere vRealize Provisioning
Configuration
NSX vSAN
SDDC Manager
Deployment
Top-of-Rack Switches
Management Switch
Available
Capacity
Expand
Minimum
Management Workload Domain Of 4
ReadyNodes
App App
App App
App App
Build a True
Hybrid Cloud
SDDC with
Cloud
Modernize with Efficiency
Hyper-Converged
Server Infrastructure
Virtualization
33% 33%
CAGR
Hyper-Converged Integrated
Systems CAGR
3X
Faster than overall Integrated
Systems Market
56%
Of overall external storage market*
2016 2017 2018 2019 2020 2021 2022 2023
Source: IDC Converged Systems Tracker Forecast, Q42018, Published April 2019
Confidential │ ©2018 VMware, Inc. Lagana, Sebastian and Yezhkova, Natalya. Wordwide and U.S. Enterprise Storage Systems Forecast 2019-2023, IDC. Published May 2019, #US45023719 19
Waarom vSAN?
=
Lagere TCO Altijd klaar voor
Hybrid Cloud Ready
nieuwe projecten
Proven Technology
Confidential │ ©2018 VMware, Inc. 20
vSAN
Modernize with Hyper-Converged Infrastructure
RAID1
replicated vCenter UI
RAID5
replicated
RAID6
Storage replicated
RAID1 non-
replicated
SAN
VSA VSA VSA VSA
SAN Zoning
Datastore 1 Datastore 2 Datastore…
vSphere + vSAN
LAN LAN
The vSAN Difference
Other HCI solutions using non-integrated VMs for storage processing
Resource-intensive storage
Storage Storage controller VMs on every host
VM VM
NFS NFS
More hops, context
switching, queues, and locks
Host CPU and I/O
Host & Hypervisor Host & Hypervisor amplification
Fewer VMs per host, with
less consistent performance
Unaware of hypervisor
Committing a Write I/O in other HCI solutions activities
Compute Utilization
vSAN 6.0 vSAN 6.1 vSAN 6.2 vSAN 6.5 vSAN 6.6.x vSAN 6.7
March 2015 Sep 2015 March 2016 Nov 2016 Apr/July 2017 April 2018
All Flash Stretched Cluster Deduplication iSCSI Support Native Encryption Modern UI
64 Node Cluster 5min RPO Compression 2-Node Connect vSAN Config Assist Native vRealize
2x Hybrid Speed 2-node ROBO RAID5/6 Large Drives Cloud Analytics FIPS 140-2
Quality of Service Intelligent Operations Adaptive Resync
50% higher performance Host Pinning
Number of Workloads
©2018 VMware,©2019
Confidential Inc. VMware, Inc. 38
25
vSAN is the Most Popular HCI Solution
>20,000
Customers
18
19
14
16
5
4
15
15
6
14
16
18
0
15
19
19
14
16
9
1'1
1'1
1'1
Y1
Y2
3'
2'
3'
3'
FY
2'
4'
2'
FY
FY
FY
4'
4'
FY
Q
Q
1'F
Q
Q
Q
Q
Q
1'F
3'
4'
2'
3'
4'
Q
Q
Q
vSAN Customer Adoption
* Switched to Dell Technologies fiscal calendar. Q4’16 ended Dec 31, 2016. Q1’18 ended May 5, 2017
Eenvoud
SQL Policy:
- Performance Optmized (RAID1)
- 2 Failures to Tolerate
- Stretched
Generic Policy:
- Capacity Optimized (RAID6)
- 2 Failures to Tolerate
- Stretched
Dev/Test Policy: Dev/
- Capacity Optimized (RAID5) Test
- 1 Failure to Tolerate
- QoS Limiet 1000 IOPS
DC1 - Not Stretched (DC1 Only) DC2
Generic
vSpherevSphere
+ vSAN + vSAN SQL
Capaciteit
Witness
Integrated Capacity and Performance Monitoring
vCenter based capacity and performance metrics for vSAN
29
vRealize Powered Intelligence Embedded in vCenter
vRealize Operations within vCenter
vCenter UI
vR
Ops
vCenter UI vmware.com
vSphere vSAN
VMware GSS
Object
700GB
RAID-1
FTT=1
RAID-1
C1
C2
C3
C1
C2
C3
Witness
1Gb switch
Cluster
vSAN traffic
vSphere vSAN vSphere vSAN
Workloads
EUC
Windows or
Linux Server
vSAN iSCSI target Service
Physical enables block storage for
legacy physical workloads
Provides all core vSAN
features for iSCSI target
iSCSI Network
Manage performance &
protection using SPBM
vSAN iSCSI Targets
Native integration (no virtual
appliance)
iSCSI Object iSCSI Object
LUN sizes up to 62TB
CHAP & Mutual CHAP
vSAN Datastore support
Windows Windows
Failover Cluster Failover Cluster
Extends support of
Physical Physical Windows Server Failover
Clusters (WSFC) when using
vSAN iSCSI service
In-guest
Initiators Supports the following:
iSCSI Network
• Physical - Using guest iSCSI
initiator
vSAN iSCSI Targets
• Virtual – Using guest iSCSI
Active Standby Active Standby initiator
iSCSI Object iSCSI Object
Transparent failover of
WSFC with vSAN iSCSI
volumes
vSAN Datastore
Appliance ReadyNodeTM
Capacity Capacity
vSAN vSAN
All Flash for supreme performance per host vSAN can use next-gen hardware
Deduplication
RAID-1
• Per disk group
vSphere vSAN
• Occurs when destaging to
capacity tier
Scale with
full system
Complex
planning Scale with
single node
Capex
Initial $
Predictable
outcome
5 5 5 5 5
5 5 7 6 27
🚫
Confidential │ ©2018 VMware, Inc. 51
Sizing
RAID-1
FTT=1
RAID-1
FTT=2
RAID-1
FTT=3
RAID-5
(FTT=1)
RAID-6
(FTT=2)
=
Lagere TCO Altijd klaar voor
Hybrid Cloud Ready
nieuwe projecten
Proven Technology
Confidential │ ©2018 VMware, Inc. 1. Source: Represents share of HCI Software revenue in 1Q18. IDC’s 1Q2018 Worldwide Quarterly Converged Systems Tracker, June 2018 62
HCI Industry Leadership
Contact us at:
mdehaan@vmware.com