MICROMETRIC VALVE
- Application:
1
CLEAN METAL SANITARY CONNECTIONS
Machine Translated by Google
- Dimensions:
- Formula:
For pressure values other than 1 kgf/cm², the flow can be calculated using the following formula:
Where:
Q = Flow in m³/h. Q = Kv x ÿ ÿ P
Kv = See table above. ÿ P =
Pressure remaining in kgf/cm² on the valve.
Example: 1.1/2” valve with Date Kv 43 e ÿ P = 2 kgf/cm²
Date in 100%:
Q = 43 x ÿ 2 = 60.8 m³/h - Exploded View:
Date in 50%:
Q = 0.5 x 43 x ÿ 2 = 30.4 m³/h
Conversation Factors:
Peças List
Kv: Q= [m³/h] ÿP= [kgf/cm²]
CV: Q= [gal/min] ÿP= [psi] 01 Body
02 Anel de Vedação
Kv= Cv x 0.85.
03 Date
Cv= Kv x 1.18.
04 Cone
05 Vedação Disc
06 Adapter
07 Abraçadeira
08 Maniple
09 Engate
10Tampa
11 Arruela de Trava