Re: Incidencia # 71978902 - M5000 caído sábado, 14 de noviembre de 2009


--Snapshot -- 5:50:13
De: jmartinez@gcs-iberia.com
Para: Angel.Rico@sun.com
CC: ooh-spain-field@sun.com
Archivos adjuntos: sech43edaeor13-xscf0_10.235.33.215_2009-11-14T04-35-39.zip (6608.2KB)
Adjunto snapshot

----- Mensaje original -----


De: "Angel Rico" <Angel.Rico@Sun.COM>
Para: "Jesus Martinez Fernandez" <jmartinez@gcs-iberia.com>
Enviados: Sábado, 14 de Noviembre 2009 5:14:55 GMT +01:00 Amsterdam / Berlín / Berna /
Roma / Estocolmo / Viena
Asunto: Re: Incidencia # 71978902 - M5000 caído

Hola Jesús.

Te llamo a tu móvil en éste momento.

Adjutno el doc. para hacer "clear" a componentes en fallo.


Supongo es el que has estado aplicando.

=================================

Document Audience: INTERNAL


Document ID: 209792
Old Document ID: (formerly 89850)
Title: Sun SPARC® Enterprise Mx000 (OPL) Servers: Fault clearing and LEDs behavior
Copyright Notice: Copyright © 2009 Sun Microsystems, Inc. All Rights Reserved
Update Date: Tue Aug 26 00:00:00 MDT 2008
Solution Type Technical Instruction

Solution 209792 : Sun SPARC® Enterprise Mx000 (OPL) Servers: Fault clearing and LEDs
behavior

Related Categories

* Home>Product>Systems>Servers

Description

Fault Management Architecture on the Sun SPARC [TM] Enterprise Mx000 (OPL) Servers

The implementation for the Fault Management Architecture on the Sun SPARC® Enterprise
Mx000 (OPL) Servers is complex.
The goal of this document is not to describe how FMA behaves on the Sun SPARC®
Enterprise Mx000 (OPL) Servers but to help to
identify and display the faults reported on the components of these platforms, how/when
these faults can be cleared and how/when the
fault LEDs are turned ON or OFF.

Faults on Sun SPARC® Enterprise Mx000 (OPL) Servers :

FMA is obviously available on the Sun SPARC® Enterprise domains running Solaris[TM] 10.
But FMA has also been ported to run on the Service Processor and the fmd daemon is
running as part of the XSCF software.
Via the "Event Transport Module" (ETM) on top of the "Domain to Service Processor
Communications Protocol" (DSCP), XSCF on the Service Processor and Solaris on the
domain, we can communicate ereports and faults.

When a fault is diagnosed, the system is able to identify one or several suspects,
depending on the nature of the fault. The suspect or the list of the suspects can be

1 de 11 17/11/2009 11:40
Zimbra: rlopez@gcs-iberia.com http://127.0.0.1:7633/desktop/login.jsp?at=67ecab1f-91be-4cdf-ac2f-3...

displayed using the 'fmdump' command on XSCF.

Example where a list of suspects has been identified :

XSCF> fmdump -v
May 25 16:02:53.0556 6070a711-49ad-4b23-a172-5524274deceb SCF-8001-KC
66% upset.chassis.SPARC-Enterprise.io.disk.boot

Problem in: hc:///chassis=0/iou=8/pcislot=0/ioua=0/pci_br=0/sas=0/disk=1


Affects: -
FRU: hc://:product-id=SPARC-Enterprise:chassis-id=BE80601000:server-id=san-
dc3-1-0/component=/IOU#8/HDD#1

33% upset.chassis.SPARC-Enterprise.io.disk.boot

Problem in: hc:///chassis=0/iou=8/pcislot=0/ioua=0/pci_br=0/sas=0


Affects: -
FRU: hc://:product-id=SPARC-Enterprise:chassis-id=BE80601000:server-id=san-
dc3-1-0/component=/IOU#8/PCI#0/IOUA

Example where only one suspect has been identified :

XSCF> fmdump -v -u 7d1b6fac-ff1f-4d3d-afff-faf6c0a2ed07


Jun 15 02:53:32.1628 7d1b6fac-ff1f-4d3d-afff-faf6c0a2ed07 SCF-8005-PX

100% upset.chassis.domain.panic
Problem in: hc:///chassis=0/domain=0
Affects: -
FRU: hc://:product-id=SPARC-Enterprise:chassis-id=BE80601000:server-id=san-
dc3-1-0/component=CHASSIS

The Knowledge Articles available at http://www.sun.com/msg request to collect the


result for a 'fmdump -m'.
The "-m" option is available only on the XSCF (not on the Solaris domain) and displays
the Fault Manager syslog message contents for the event(s).

Example :

XSCF> fmdump -m
T-TIME: Fri Apr 13 08:06:05 PDT 2007
PLATFORM: SPARC-Enterprise, CSN: BE80601000, HOSTNAME: san-dc3-1-0
SOURCE: sde, REV: 1.12
EVENT-ID: cfcd90f3-5988-4707-ba8e-fdd03d417fc3
DESC: An internal fatal error within a strand on a CPU chip was detected.
Refer to http://www.sun.com/msg/SCF-8000-EQ for more information.
AUTO-RESPONSE: The domain using this CPU will be reset and the strand will be
deconfigured.
IMPACT: The domain using this CPU chip is reset.
REC-ACTION: Schedule a repair action to replace the affected Field Replaceable Unit
(FRU),
the identity of which can be determined using fmdump -v -u EVENT_ID.
Please consult the detail section of the knowledge article for additional information.

Only users with the platop, platadm, or fieldeng privileges can run the 'fmdump'
command.

The information about the faulty status of the components is available in the CMEM
database on XSCF.
Based on the certainty of the fault, the following flags are set in the CMEM :

CFF => Certainly Faulty Flag


*

UFF => Uncertainly Faulty Flag

Every FRU that is considered as suspect in the list has the uncertain_secondary_status
set. But only the primary suspect may also have the CFF or UFF bit set.

As a consequence for a fault detected and depending on the CFF or UFF bit set, the
primary suspects in a suspect list are reported as "faulted" (completely broken/not
working) or "degraded" (should be replaced, but is still working with some limitations)
in the 'showhardconf' and 'showstatus' outputs.
The secondary suspects show up as "degraded". Some components may be reported as
"deconfigured" if these components are victims of a fault detected on another

2 de 11 17/11/2009 11:40
Zimbra: rlopez@gcs-iberia.com http://127.0.0.1:7633/desktop/login.jsp?at=67ecab1f-91be-4cdf-ac2f-3...

component.

As part of FMA ported on XSCF, the 'fmadm faulty' command is only available in
Escalation mode. The resource cache has less info about platform faults than the "CMEM"
database. CMEM is the database that has the real info about faulty FRUs for OPL, not
the resource cache.
Therefore, the 'showstatus' command is the preferred method to be used by the customer
and field, as it provides a truly accurate picture of what is going on regarding
faults.

The 'showstatus' and 'showhardconf' commands are available to the users with the
following privileges :
useradm, platadm, platop, fieldeng

Example for the showstatus and showhardconf commands reporting a chip on a CPU Module
as "faulted".

XSCF> showstatus CMU#1 Status:Normal;


* CPUM#2-CHIP#0 Status:Faulted;

XSCF> showhardconf -M
SPARC Enterprise M9000;
+ Serial:BE80601000; Operator_Panel_Switch:Locked;
+ Power_Supply_System:Dual-3Phase; Ex:Dual-3Phase; SCF-ID:XSCF#0;
+ System_Power:On;
[output omitted]
CMU#1 Status:Normal; Ver:0101h; Serial:PP0642Z470 ;
+FRU-Part-Number:CA06620-D001 A8 ;
+ Memory_Size:64 GB;
CPUM#0-CHIP#0 Status:Normal; Ver:0201h; Serial:PP06447337 ;
+FRU-Part-Number:CA06620-D021 A6 ;
+ Freq:2.280 GHz; Type:16;
+ Core:2;Strand:2;
CPUM#1-CHIP#0 Status:Normal; Ver:0201h; Serial:PP06447340 ;
+FRU-Part-Number:CA06620-D021 A6 ;
+ Freq:2.280 GHz; Type:16;
+ Core:2;Strand:2;
* CPUM#2-CHIP#0 Status:Faulted; Ver:0201h; Serial:PP06447336 ;
+FRU-Part-Number:CA06620-D021 A6 ;
+ Freq:2.280 GHz; Type:16;
+ Core:2;Strand:2;
[output omitted]

Example from a M9000 system where a CMU is reported as degraded due to some DIMMs
deconfigured as a consequence for a fault detected on the Memory Address Controller.

XSCF> fmdump -av


TIME UUID MSG-ID
Apr 29 20:03:02.7818 5817837d-6ee9-4ffd-af17-fee44d76da0d SCF-8005-CA
100% fault.chassis.SPARC-Enterprise.asic.sc.fe

Problem in: hc:///chassis=0/cmu=6/sc=2


Affects: hc:///chassis=0/cmu=6/mac=2/bank=0

XSCF> showstatus
* CMU#6 Status:Degraded;
* MEM#00A Status:Deconfigured;
* MEM#00B Status:Deconfigured;
* MEM#01A Status:Deconfigured;
* MEM#01B Status:Deconfigured;
* MEM#02A Status:Deconfigured;
* MEM#02B Status:Deconfigured;
* MEM#03A Status:Deconfigured;
* MEM#03B Status:Deconfigured;
* MEM#10A Status:Deconfigured;
* MEM#10B Status:Deconfigured;
* MEM#11A Status:Deconfigured;
* MEM#11B Status:Deconfigured;
* MEM#12A Status:Deconfigured;
* MEM#12B Status:Deconfigured;
* MEM#13A Status:Deconfigured;
* MEM#13B Status:Deconfigured;

For some components considered as primary suspect and certainly faulty (CFF), the
Maintenance Action Required bit is set.
This information is available in a 'fmdump -V' output.

3 de 11 17/11/2009 11:40
Zimbra: rlopez@gcs-iberia.com http://127.0.0.1:7633/desktop/login.jsp?at=67ecab1f-91be-4cdf-ac2f-3...

Example :

XSCF> fmdump -Ve


TIME CLASS
Jun 15 2007 02:48:35.110134400 ereport.chassis.SPARC-Enterprise.cpu.SPARC64-VI.se-
offlinereq
nvlist version: 0
class = ereport.chassis.SPARC-Enterprise.cpu.SPARC64-VI.se-offlinereq
[output omitted]
opl_platform = DC3
detected-by = ANALYZE
maintenance-action-required = true
__ttl = 0x1
__tod = 0x46726073 0x6908480

Further OPL FMA information can be found at OPL FMA.

Steps to Follow

Clearing Faults on Sun SPARC [TM] Enterprise Mx000 (OPL) Servers

Clearing Faults (Sun SPARC® Enterprise Mx000 (OPL) Servers running XCP 1050 or later) :

1. Usual process :

The right course of action when the system has identified faulty components on a
platform is to replace the primary suspect.

In order to repair a fault with single or multiple FRUs, the typical repair action will
be:

* Replace the first FRU indicted in the suspect list; if the FRU is a CMU or
sub-FRU of a CMU (on M8000/M9000), IOU (on M8000/M9000), FAN, PSU, DDC_A (on M8000),
XSCFU (on M8000/M9000), or XSCFU_C (M9000 plus expansion cabinet) use the 'replacefru'
command to do so; Otherwise, use cold replacement;
The fieldeng privileges are required to run the 'replacefru' command.

* For all the other FRUs on the suspect list (secondary suspects), use the
'clearfault' command.
The 'clearfault' command will return with an error message when trying to clear a
FRU that is the first suspect on a suspect list :
"clearfault: Fault cannot be cleared for this FRU"
You must be in Service or Escalation mode to run the 'clearfault' command.
* Sun Shared Shell
The Service Engineer should offer the use of Shared Shell to accomplish the
service mode and clearfault.
Before the Shared shell session is terminated the "disablemodes" command should
be run.

2. Complex cases :

In some more complex cases, the context might lead to the decision to not replace the
first FRU in the suspect list.
This might be due to the diagnosis engine being wrong or the FRU in a single-FRU
indictment seems to be wrong or first FRU has already been replaced and this is a
repeat fault with an identical list etc...
The decision to not replace the first FRU in the suspect list MUST be done by Service
and the whole process of clearing a fault without replacing the suspect component must
be done under the supervision of TSC.
The following section describe how to handle the complex cases.

2.1 - Power cycle (NFB Off/On) :

For the systems running XCP1050, it's possible to clear the fault status for primary
suspects by power-cycling the platform and the keyswitch is in the service position.

For the systems running XCP1060 and later, faults are not be cleared on NFB-on, no
matter what the position of the keyswitch.

Note :
Whatever the component (with ot without FRUID), a power cycle with the keyswitch is in
the Locked position will not have any effect on the fault status of this component.
Except if clearfault/clearstatus/clearfru have been invoked previously; see the section

4 de 11 17/11/2009 11:40
Zimbra: rlopez@gcs-iberia.com http://127.0.0.1:7633/desktop/login.jsp?at=67ecab1f-91be-4cdf-ac2f-3...

below.

2.2 - Commands available to clear the faults :

2.2.1 - clearfru / clearstatus :

These 2 commands can be used to clear the fault information of all the FRUs (clearfru)
or the fault information of FRUs that have been detected as faulty units (clearstatus).

You must be in Escalation mode to run the clearfru / clearstatus commands.

The domains must be down and an immediate platform power cycle is required.
The component is reported as faulted as long as the power cycle hasn't occured.

Using clearfru and clearstatus must be done only on directions from TSC and/or
Engineering.

Example :

XSCF> showstatus
CMU#0 Status:Faulted;

service# clearstatus /CMU#0

XSCF> showstatus
No failures found in System Initialization.

2.2.2 - clearfault :

The 'clearfault' command provides a much clever way to manage faults for primary
suspects and can be used in a way to :

* Immediately clear the fault status for other FRUs than the first suspect in a
multi-suspect list,

* Clear the fault for FRUs reported as the first suspect in a suspect list in the
following cases :

2.2.2.1 - During the next power-cycle by using 'clearfault [-l]' (no need for the
keyswitch to be in the service position).

As a consequence, the next power-cycle clears the faults for the components.

Notes :

* If the user invokes 'clearfault -l', there is no attempt to clear the fault
status now. The user is prompted with the information that the
"FRU will be marked to clear fault on next circuit breaker off and on."

Example :

service# clearfault -l /IOU#0


Fault will be cleared after circuit breaker off and on

* If the user invokes 'clearfault' (without -l), the system will attempt to clear
the status now.
If the FRU is a primary suspect and clearfault cannot clear the fault status, it
will prompt the user requesting whether or not the FRU should be marked to clear fault
on next circuit breaker off and on; behaving the same manner as invoking 'clearfault
-l' directly.

Example :

service# clearfault /IOU#0


clearfault: Fault cannot be cleared for this FRU.
FRU will be marked to clear fault on next circuit breaker off and on.
Continue? [y|n]: y
Fault will be cleared after circuit breaker off and on

* If clearfault is invoked when another maintenance command is running, it will


behave the same manner as invoking 'clearfault -l' directly.

Example :

service# clearfault /IOU#0


Unable to get maintenance lock

5 de 11 17/11/2009 11:40
Zimbra: rlopez@gcs-iberia.com http://127.0.0.1:7633/desktop/login.jsp?at=67ecab1f-91be-4cdf-ac2f-3...

clearfault: Fault cannot be cleared for this FRU.


FRU will be marked to clear fault on next circuit breaker off and on.
Continue? [y|n]:

2.2.2.2 - M4000/M5000 :

* Immediately clear the fault for the first suspect in a suspect list if the FRU is
a PSU or a FAN,

Example :

service# clearfault /FAN_B#0


Testing the hardware...

* For the other FRUs, a power cycle is required to clear the fault.

Example :

service# clearfault /MBU_A/MEMB#0/MEM#0A


clearfault: Fault cannot be cleared for this FRU.
FRU will be marked to clear fault on next circuit breaker off and on.
Continue? [y|n]: yes
Fault will be cleared after circuit breaker off and on

Note :

With XCP 1050, there is no way to clear a UFF or CFF fault in a DDCR on a M4000/M5000
IOU using the clearfault command.
The only way is to invoke clearfru in escalation mode and power cycle the platform.
Reference : CR#6577745.
This is fixed in release of XCP 1060.

2.2.2.3 - M8000/M9000 :

* Immediately clear the fault for the first suspect in a suspect list if the FRU is
a PSU or FAN or DDC_A or XSCFU_B or XSCFU_C.

Example :

service# clearfault /PSU#0


Testing the hardware...

* Immediately clear fault if the FRU is a CMU or IOU, including sub-FRUs like CPUM,
DIMM ... and non-FRU like DDC, SSM ..., without NFB off/on when :
o the CMU, IOU (and sub-FRU and non-FRU) is not part of a running domain. See
the Examples section below.
o If the FRU is a CMU (and sub-FRU and non-FRU) or an IOU and is part of a
running domain, Dynamic Reconfiguration (deleteboard) must be invoked prior to run the
clearfault command in order to detach the FRU from the domain. After clearing the
fault, the component can safely be added back to the domain. See the Examples section
below.
o If the FRU is a CMU (and sub-FRU and non-FRU) or an IOU and is part of a
running domain but DR cannot be used then the domain must be powered off in order to
immediately clear the fault status. Otherwise, the fault status will be cleared on next
circuit breaker off and on. See the Examples section below.

2.3 - As a summary, to clear fault on a FRU :

M4000 / M5000 :
FRU Power cycle (XCP1050 only) clearfault clearstatus/clearfru
PSU/FAN Keyswitch in service position Immediate Domains down and requiers a power
cycle whatever the keyswitch position
CPUM/DIMM/IOU/MEMB/OPNL Keyswitch in service position After a power cycle, whatever
the keyswitch position Domains down and requiers a power cycle whatever the keyswitch
position

M8000 / M9000 :
FRU Power cycle (XCP1050 only) clearfault clearstatus/clearfru
PSU/FAN/XSCFU/DDC_A Keyswitch in service position Immediate Domains down and after a
power cycle whatever the keyswitch position
OPNL Keyswitch in service position After a power cycle, whatever the keyswitch
position Domains down and after a power cycle whatever the keyswitch position
CMU/CPUM/DIMM/IOU/non-FRU Keyswitch in service position if not part of a running
domain : Domains down and after a power cycle whatever the keyswitch position
. Immediate

6 de 11 17/11/2009 11:40
Zimbra: rlopez@gcs-iberia.com http://127.0.0.1:7633/desktop/login.jsp?at=67ecab1f-91be-4cdf-ac2f-3...

if part of a running domain:


. Immediate after DR (deleteboard) + clearfault
. Immediate after powering off the domain + clearfault
. otherwise after clearfault + NFB Off/On whatever the keyswitch position

For more detail on accessing escalation or service mode see Sun Document 91335

LED behaviour :

Each Mx000 system has an Operator Panel (OPNL) with 3 LEDs :

* the Power LED,


* the XSCF Standby LED,
* the Check LED.

When turned ON, the Check LED, aka the System Check LED, indicates a fault on the
system. See below.

Most of the FRUs on the SPARC Enterprise servers have a FRU check LED which reports
that the unit contains an error.
However, some FRUs like DIMMs or CPUMs do not have LEDs.

Refer to the SPARC Enterprise Mx000/Mx000 Servers Service Manuals for more information
about LEDs.

For Sun SPARC® Enterprise servers running a version of XCP later than 1050, the check
LEDs will be set and reset as below :

* the FRU check LED is set if the FRU is the sole FRU in a suspect list; including
sub-FRU (CPUM, DIMM ...) and non-FRU (DDC, SSM ...).
* the system check LED is set if there are any FRUs which is considered as the
primary suspect (CFF / UFF) or secondary suspect; which means when 'showstatus' reports
any FRUs as faulty or degraded.
Including IO Box FRUs reported as suspect.

Note that the check LED for the PSUs on the M8000/M9000 may not behave as expected; not
being set when it's the primary suspect.

Check LEDs behaviour after clearfault, clearstatus, replacefru :

* replacefru :
o the FRU's check LED is :
+ ON until the maintenance,
+ blinking during the maintenance,
+ OFF as soon as the replacefru as completed successfully.
o the System check LED is OFF :
+ as soon as the replacefru as completed successfully,
+ and there is no other suspect component in the system left,

* clearfault :
o the FRU's check LED is turned off as soon as the clearfault command has
succeeded successfully in clearing the fault for the FRU.
o the System's check LED is turned off as soon as the fault status for the
latest suspect component is cleared.
This implies that the LED will turn off after the subsequent power cycle in
certain cases as applicable.

* clearstatus/ clearfru : the FRU and System check LEDs remain ON until the next
power cycle,

Faults on IOBox :

Faults detected on IOBox are stored in the CMEM and in the FRUID of the IOBox
(Status_CurrentR).
This information is reported in the showstatus output on the XSCF.
Example :

XSCF> showstatus
IOU#4 Status:Normal;
* PCI#5 Status:Degraded;
IOX@X156 Status:Normal;
* IOB1 Status:Faulted;
* PS0 Status:Degraded;
* PS1 Status:Degraded;

7 de 11 17/11/2009 11:40
Zimbra: rlopez@gcs-iberia.com http://127.0.0.1:7633/desktop/login.jsp?at=67ecab1f-91be-4cdf-ac2f-3...

When a fault is reported on the IOBox or its components, the Service LED on the IOBox
or PSU is lit.
When an iobox fru is discovered, dfrud reads the Status_CurrentR. If it contains fault
info, the fault info is added to CMEM, and the Service led is turned on.
This can be checked via the ioxadm command :
XSCF> ioxadm env -v
Location Sensor Min Min Alarm Value Max Alarm
Max Units
[...]
IOX@X156/IOB1 SERVICE - - On -
- LED

Even if a fault is reported on IOBox and Service LED is lit, the OPNL System Ckeck LED
is not lit.

The clearfault command can be used to clear the fault status for primary and secondary
suspect on the IOBox and its components; similarly to any other components in the
platform chassis (CMU, DIMM, IOU etc ...) for XCP > 1050.
Example :

XSCF> showstatus
IOU#4 Status:Normal;
* PCI#5 Status:Degraded;
IOX@X156 Status:Normal;
* IOB1 Status:Faulted;
* PS0 Status:Degraded;
* PS1 Status:Degraded;
service> clearfault IOU#4-PCI#5
service> clearfault IOX@X156/IOB1
service> clearfault IOX@X156/PS0
service> clearfault IOX@X156/PS1
XSCF> showstatus
No failures found in System Initialization.

Clearing the LINK to the IOBox:

Example:
service> clearfault IOX@X1CK/IOB0/LINK

As soon as there is no more fault status reported in the showstatus output then all the
Service LEDs are cleared.

There is no condition requiring to power cycle the IOBox to clear a fault status
(similar to clearfault -l).

Hierarchical fault clearing :

In certain cases, the faulted resources appear to be hierarchical.


In the following example, after clearing the fault on CMU#0, we need to clear the fault
on the subordinates.

XSCF> showstatus
* CMU#0 Status:Faulted;
* CPUM#0-CHIP#0 Status:Faulted;
* MEM#03A Status:Faulted;

service# clearfault CMU#0

XSCF> showstatus
CMU#0 Status:Normal;
* CPUM#0-CHIP#0 Status:Faulted;
* MEM#03A Status:Faulted;

CMU#0 remains in the output, although not marked faulted, until the subordinates are
cleared:

service# clearfault CMU#0/CPUM#0

XSCF> showstatus
CMU#0 Status:Normal;
* MEM#03A Status:Faulted;

service# clearfault CMU#0/MEM#03A

8 de 11 17/11/2009 11:40
Zimbra: rlopez@gcs-iberia.com http://127.0.0.1:7633/desktop/login.jsp?at=67ecab1f-91be-4cdf-ac2f-3...

XSCF> showstatus
No failures found in System Initialization.

1. M4000 / M5000 :

1.1 - clearing a fault on a PSU :

XSCF> showstatus
* PSU#1 Status:Faulted;

service# clearfault /PSU#1


Testing the hardware...

XSCF> showstatus
No failures found in System Initialization.

1.2 - clearing a fault on a DIMM :

XSCF> showstatus
MBU_A Status:Normal;
MEMB#0 Status:Normal;
* MEM#0A Status:Faulted;

service# clearfault /MBU_A/MEMB#0/MEM#0A


clearfault: Fault cannot be cleared for this FRU.
FRU will be marked to clear fault on next circuit breaker off and on.
Continue? [y|n]: yes
Fault will be cleared after circuit breaker off and on

XSCF> showstatus
MBU_A Status:Normal;
MEMB#0 Status:Normal;
* MEM#0A Status:Faulted;

1.3 - clearing a fault on a CPUM :

XSCF> showstatus
MBU_A Status:Normal;
* CPUM#0-CHIP#0 Status:Faulted;
* CPUM#0-CHIP#1 Status:Faulted;

service# clearfault /MBU_A/CPUM#0


clearfault: Fault cannot be cleared for this FRU.
FRU will be marked to clear fault on next circuit breaker off and on.
Continue? [y|n]: y
Fault will be cleared after circuit breaker off and on

XSCF> showstatus
MBU_A Status:Normal;
* CPUM#0-CHIP#0 Status:Faulted;
* CPUM#0-CHIP#1 Status:Faulted;

2. M8000 / M9000 :

2.1 - clearing a fault on a PSU :

XSCF> showstatus
* PSU#0 Status:Faulted;

service# clearfault /PSU#0


Testing the hardware...

XSCF> showstatus
No failures found in System Initialization.

2.2 - clearing a fault on the OPNL :

XSCF> showstatus
* OPNL#0 Status:Faulted;

service# clearfault /OPNL


clearfault: Fault cannot be cleared for this FRU.
FRU will be marked to clear fault on next circuit breaker off and on.
Continue? [y|n]: y
Fault will be cleared after circuit breaker off and on

9 de 11 17/11/2009 11:40
Zimbra: rlopez@gcs-iberia.com http://127.0.0.1:7633/desktop/login.jsp?at=67ecab1f-91be-4cdf-ac2f-3...

XSCF> showstatus
* OPNL#0 Status:Faulted;

2.3 - clearing a fault on an IOU not part of a running domain :

XSCF> showstatus
* IOU#1 Status:Faulted;

XSCF> showboards -v -a
XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD
---- - -------- ----------- ---- ---- ---- ------- -------- ----
00-0 * 00(00) Assigned y n n Unknown Normal n
01-0 * 00(01) Assigned y n n Unknown Faulted n
02-0 SP Unavailable y n n Unknown Normal n
03-0 SP Unavailable y n n Unknown Normal n

service# clearfault /IOU#1


Testing the hardware. This may take up to six minutes

XSCF> showstatus
No failures found in System Initialization.

2.4 - clearing a fault on a CMU not part of a running domain

service# clearfault /CMU#2/CPUM#2


Testing the hardware. This may take up to six minutes

XSCF> showstatus
No failures found in System Initialization.

2.5 - clearing a fault on a CMU which is part of a running domain :

XSCF> showstatus
CMU#3 Status:Normal;
* CPUM#0-CHIP#0 Status:Faulted;
* OPNL#0 Status:Faulted;

XSCF> showboards -v -a
XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD
---- - -------- ----------- ---- ---- ---- ------- -------- ----
00-0 00(00) Assigned y y y Passed Normal n
01-0 00(01) Assigned y y y Passed Normal n
03-0 00(03) Assigned y y y Passed Degraded n

service# clearfault /CMU#3/CPUM#0


FRU cannot be detached
clearfault: Fault cannot be cleared for this FRU.
FRU will be marked to clear fault on next circuit breaker off and on.
Continue? [y|n]: n

We can use DR to detach the XSB and clear the fault.

XSCF> deleteboard -c unassign 03-0


XSB#03-0 will be unassigned from domain immediately. Continue?[y|n] :y
Start unconfiguring XSB from domain.
Unconfigured XSB from domain.
XSB power off sequence started. [1200sec]
0...end
Operation has completed.

XSCF> showboards -v -a
XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD
---- - -------- ----------- ---- ---- ---- ------- -------- ----
00-0 00(00) Assigned y y y Passed Normal n
01-0 00(01) Assigned y y y Passed Normal n
03-0 SP Available y n n Passed Degraded n

service# clearfault /CMU#3/CPUM#0


Testing the hardware. This may take up to six minutes

XSCF> showboards -v -a
XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD
---- - -------- ----------- ---- ---- ---- ------- -------- ----
00-0 00(00) Assigned y y y Passed Normal n
01-0 00(01) Assigned y y y Passed Normal n
03-0 00(03) Assigned y y y Passed Normal n

10 de 11 17/11/2009 11:40
Zimbra: rlopez@gcs-iberia.com http://127.0.0.1:7633/desktop/login.jsp?at=67ecab1f-91be-4cdf-ac2f-3...

XSCF> showstatus
No failures found in System Initialization.

2.6 - clearing a fault on a CMU which is part of a running domain but DR cannot be used
:

XSCF> showstatus
CMU#3 Status:Normal;
* MEM#00A Status:Faulted;

XSCF> clearfault /CMU#3/MEM#00A


FRU cannot be detached
clearfault: Fault cannot be cleared for this FRU.
FRU will be marked to clear fault on next circuit breaker off and on.
Continue? [y|n]: n

XSCF> showboards -v -a
XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD
---- - -------- ----------- ---- ---- ---- ------- -------- ----
00-2 00(00) Assigned y y y Passed Normal n
03-0 00(12) Assigned y y y Passed Degraded n

Since DR cannot be used for whatever reason, the domain must be powered off prior to
using clearfault :

XSCF> showdomainstatus -d 0
DID Domain Status
00 Powered Off
service> clearfault /CMU#3/MEM#00A
Testing the hardware. This may take up to six minutes
XSCF> showstatus
No failures found in System Initialization.

XSCF> showboards -v -d 0
XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD
---- - -------- ----------- ---- ---- ---- ------- -------- ----
00-2 * 00(00) Assigned y n n Passed Normal n
03-0 * 00(12) Assigned y n n Passed Normal n

Product

Sun SPARC Enterprise M5000 Server


Sun SPARC Enterprise M4000 Server
Sun SPARC Enterprise M9000 Server
Sun SPARC Enterprise M8000 Server

Keywords

opl, fault, clear, clearfault, clearstatus, fmdump, showstatus

=================================