PPE to use:

Goggles

Chemical mask

Plastic gloves

Cleaning gown

Air extractor hood

Cleaning agent: orange spray

Drill with brush


Pressured air

Blade

Thinner
Acetone

Cleaning rags

Corrosion
PPE to use: Goggles
Chemical mask
Plastic gloves
Cleaning gown
Chemicals to use: Powerclean: Orange spray
Recommended cleaning method: 1)Spray the power clean mix on the corroded
area.
2)Let the unit rest for 3 to 5 minutes for mix to
work.
3) Clean the corroded area with brush.
3.1 Example: the RF corroded connector of the
RRU, we use de drill with brush.
4) Dry the Corroded area with pressured air
and rag.

Tools recommended Pneumatic brush + Pressured air + drill with the


brush

Outdoor units
PPE to use: Goggles
Chemical mask
Plastic gloves
Cleaning gown
Chemicals to use: Powerclean: Orange spray, thinner or acetone
Recommended cleaning method: 1) Blow with the pressurized air the
device.
2) Dampen a clean rag with orange spray
and carefully wipe any remaining dust
from the device.
3) Let the unit rest for 3 to 5 minutes for
mix to work.
4) Dry the unit with a rag.
5) take off the stickers (process below).
6) take off the markers (process below).
Example RRU.

Tools recommended Pneumatic brush + Pressured air + drill with


brush + rags

Cooling fins
PPE to use: Goggles
Chemical mask
Plastic gloves
Cleaning gown
Chemicals to use: Powerclean: Orange spray
Recommended cleaning method: 1) Blow with the pressurized air the heat
sink.

Tools recommended Pressured air + rags


Printed circuit boards
PPE to use: Goggles
Chemical mask
Plastic gloves
Cleaning gown
Chemicals to use: Powerclean: Orange spray
Recommended cleaning method: 1) Blow with the pressurized air the board.
2) Dampen a clean rag with orange spray
and carefully wipe any remaining dust
from the board.
3) Dry the unit with a rag.

Tools recommended Pressured air + rags

Plastics
PPE to use: Goggles
Chemical mask
Plastic gloves
Cleaning gown
PPE to use: Powerclean: Orange spray
Chemicals to use: 1) Blow with the pressurized air the
plastic.
2) Dampen a clean rag with orange spray
and carefully wipe any remaining dust
from the plastic.
3) Dry the unit with a rag.

Tools recommended Pressured air + rags

Paint / markers
PPE to use: Goggles
Chemical mask
Plastic gloves
Cleaning gown
Chemicals to use: Powerclean: Acetone
Recommended cleaning method: 1) Blow with the pressurized air the
device.
2) Dampen a clean rag with acetone and
carefully wipe over the markers.
3) Let the unit rest for 3 to 5 minutes for
mix to work.
4) Dry the unit with a rag.
5) Blow with the pressurized air the
device.

Tools recommended Pressured air + rag

Stickers
PPE to use: Goggles
Chemical mask
Plastic gloves
Cleaning gown
Chemicals to use: Powerclean: Thinner or acetone
Recommended cleaning method: 1) Blow with the pressurized air the
sticker.
2) Dampen a clean rag with acetone and
carefully wipe over the sticker.
3) Take off the sticker with the blade.
4) Dry the unit with a rag.

Tools recommended Rag + blade