· MATERIAL SPECIFICATION OF CHC/PHC

RECOMMENDED BY ECONOMY COMMITTEE AS


APPROVED BY THE HON'BLE CHIEF MINISTER,
Y HARYANA SHALL BE ADOPTED.

· LIFT PIT SHALL BE 1500 MM DEEP FROM THE


PLINTH LEVEL. THE SAME SHALL BE GOT
CONFIRMED FROM THE CONCERN XEN (ELEC.),
PWD (B&R) DEPARTMENT. Architecture

· MANDATORY PROVISION OF FIRE FIGHTING


SERVICE SHALL BE MADE AS PER THE NATIONAL REVISIONS
BUILDING CODE/ HARYANA BUILDING CODE.
S.NO DATE DESCRIPITION
· PROVISION OF RAIN WATER HARVESTING R 29.01.24 THESE WORKING DRAWINGS HAVE BEEN
RAIN /GROUND WATER RECHARGE SHALL BE DONE AS
PREPARED BY INCORPORATING THE
WATER PER CLAUSE NO. 8.1 (SUSTAINABLE MEASURES) STRUCTURAL ADVICE RECEIVED FROM THE
KHURRA OF HARYANA BUILDING CODE 2017. SUDAN CONSULTANCY SERVICES.
RAIN
WATER RAIN RAIN · AS PER HARYANA GOVERNMENT RENEWABLE

1'-3"
KHURRA B201 WS WATER WATER ENERGY DEPARTMENT ORDER 22/52/2005-5 POWER
KHURRA KHURRA
RAIN DATED 21 MARCH 2016, THE PROVISION OF SOLAR
WATER PHOTOVOLTAIC POWER PLANT SHALL BE MADE GENERAL NOTES:-
R.C.C. PARAPET 3'-6'' HIGH

9"
R.C.C. PARAPET 3'-6'' HIGH KHURRA
W=6'-712" IF THE BUILDING HAS THE CONCERNED LOAD OF
T=12" 30 KILO WATT (KW) AND ABOVE. · THIS DRAWING IS THE PROPERTY OF THE DEPARTMENT
R=6" OF ARCHITECTURE, GOVT. OF HARYANA. THIS DRAWING
14 MAY NOT BE ALTERED, COPIED, USED IN WHOLE OR IN

B203
THESE WORKING DRAWINGS HAVE BEEN PART WITHOUT THE PERMISSION OF THIS DEPARTMENT IN
16 WRITING.

20'
11 PREPARED BY INCORPORATING THE
18 STRUCTURAL ADVICE RECEIVED FROM THE
· THE DISCREPANCY, IF ANY MUST BE BROUGHT TO THE

B203
9 SUDAN CONSULTANCY SERVICES.
9" 20 9" NOTICE OF THE DEPARTMENT OF ARCHITECTURE
14' HARYANA BEFORE ANY ACTION AT SITE.
TERRACE LEVEL +13'-0'' FROM 22
R.C.C. PARAPET 3'-6'' HIGH
TERRACE LEVEL +13'-0'' FROM
PLINTH LEVEL. 5 · PLINTH LEVEL OF BUILDING SHALL BE FIXED IN
PLINTH LEVEL. THE EXACT SIZE OF RAIN WATER KHURRA &
DN 24 CONSULTATION WITH CONCERNED EXECUTIVE ENGINEER
3 RAIN WATER PIPES SIZE SHALL BE CONFIRMED
BY PUBLIC HEALTH ENGINEERING PUBLIC HEALTH TO AVOID FLOODING OF CAMPUS.
B202 DEPARTMENT

1"
6'-72
5'-3"
THE COPY OF APPROVAL OF FIRE FIGHTING
B201 D1-M RAIN
SCHEME UNDER 15 METERS FROM THE FIRE
SAFETY POINT OF VIEW FOR GROUP C-

2' 9"
2'-0'' WIDE PROJ. WATER
R.C.C. PARAPET 3'-6'' HIGH AT ROOF LEVEL KHURRA INSTITUTIONAL BUILDING AT VILLAGE SATROD
R.C.C. PARAPET 3'-6'' HIGH IN DISTRICT HISAR OF PRIMARY HEALTH
9'-9" 5'

1"
CENTER ISSUED BY DIRECTOR GENERAL FIRE

3'-102
9" SERVICES, PANCHKULA HARYANA HAS BEEN
RECEIVED IN THIS OFFICE FROM THE
EXECUTIVE ENGINEER VIDE E-MAIL DATED
15-01-2024.

SCHEDULE OF JOINERY
OPEN TO SKY OPEN TO SKY
S.NO. TYPE SIZE CILL TOP REMARKS

1 DG 13'-6"X10'-3" 3'-0'' 10'-3"


ENTRANCE
D=6'-712"
RAIN 2 DG1 12'-3"X10'-3" 3'-0'' 10'-3" D=6'-712"
WATER
RAIN KHURRA 3 DG2 9'-0"X10'-3" 3'-0'' 10'-3" D=6'-712"
WATER R.C.C. PARAPET 3'-6'' HIGH 4 DG2-J 9'-0"X10'-3" 3'-0'' 10'-3" LDR
SOLID FLUSH DOOR WITH
WIREMESH SHUTTER
KHURRA
5 D 6'-7½"X10'-3" - 10'-3"
RAIN
6 DA 6'-7½"X7'-6" - 7'-6" REAR SIDE ENTRANCE

WATER 7 D1 5'-0"X10'-3" - 10'-3"


KHURRA 8 D1-M 5'-0"X7'-0" 7'-0"
-
RAIN 9 D1-J 5'-0"X10'-3" - 10'-3"
SOLID FLUSH DOOR WITH
WIREMESH SHUTTER
WATER 10 10'-3"
KHURRA D2 3'-6"X10'-3" -
R.C.C. PARAPET 3'-6'' HIGH 11 D2-J 3'-6"X10'-3" - 10'-3" SOLID FLUSH DOOR WITH
WIREMESH SHUTTER

12 D3 3'-3"X7'-0" - 7'-0"
13 D4 3'-0"X7'-0" - 7'-0"
14 D5 2'-6"X7'-0" - 7'-0" TOILET

15 D6 4'-7½"X6'-3" 9'' 7'-0" LAN SHAFT DOOR

16 D7 3'-9"X6'-3" 9'' 7'-0" ELC. SHAFT DOOR

17 D8 3'-6"X4'-0" 3'-0" 7'-0" FIRE SHAFT DOOR

18 W 6'-3"X7'-3" 3'-0" 10'-3"


19 WA 6'-3"X6'-9" 3'-6" 10'-3"
20 WA' 5'-0"X6'-9" 3'-6" 10'-3"
21 WB 6'-3"X6'-3" 4'-0" 10'-3"
22 W1 6'-0"X6'-9" 3'-6" 10'-3"
23 W2 3'-0"X7'-3" 3'-0" 10'-3"
24 W2A 3'-0"X6'-9" 3'-6" 10'-3"
25 WS 6'-0"X8'-6" 3'-6" FROM LANDING LEVEL
26 WS' 4'-0"X4'-6" 3'-6" 7'-6"
27 V 6'-0"X3'-3" 7'-0" 10'-3"
28 V1 4'-0"X3'-3" 7'-0" 10'-3"
X' 29 V2 3'-0"X3'-3" 7'-0" 10'-3"
X

NOTE:- IT IS TO BE NOTED THAT TWO NOS. OF


STAIRCASES AND STRECHER LIFT IS
MANDATORY TO BE CONSTRUCTED IN CASE
OF VERTICAL EXPANSION OF SINGLE STOREY
PHC TO COMPLY THE NORMS OF FIRE & LIFE
AR. ANIL KUMAR WALIA
SAFETY AS PER NBC - 2016, HBC- 2017 & (CHIEF ARCHITECT)
GUIDELINES FOR BARRIER FREE NORMS.

THE PLINTH BEAM OF THIS SPAN SHALL BE LAID


RAIN 12" DOWN FROM THE BUILDING PLINTH BEAM SO
WATER THAT EXIT CAN BE MADE UNDER THE LANDING
KHURRA AR. DEVENDER SINGH
WITH ADEQUATE HEADROOM.
R.C.C. PARAPET 3'-6'' HIGH (SENIOR ARCHITECT)
RAIN
WATER
KHURRA
APPROVAL NOTE :-
RAIN THE STANDARD DESIGN OF SINGLE STOREY
WATER
R.C.C. PARAPET 3'-6'' HIGH KHURRA
RAIN PRIMARY HEALTH CENTRE HAS BEEN
WATER
KHURRA APPROVED BY DIRECTOR GENERAL HEALTH AR. LALIT KUMAR (VACANT)
SERVICES,HARYANA VIDE OFFICE MEMO NO.
/CONST. -2023/2198 DATED 03.05.2023.
(ARCHITECT) (ASSTT. ARCHITECT)

OFFICE OF THE
CHIEF ARCHITECT
HARYANA, CHANDIGARH
PROPOSED SINGLE STOREY
STANDARD DESIGN OF PRIMARY
HEALTH CENTRE AT VILLAGE
R.C.C. PARAPET 3'-6'' HIGH SATROD IN DISTRICT HISAR
RAIN
WATER RAIN
KHURRA WATER

TERRACE PLAN
DETAIL OF
Y' KHURRA
COLUMNS
DETAIL OF BEAMS
TARSEM (A.D.) (VACANT)
9" DEALT BY:- CHECKED BY:-
JOB NO SCALE
5"

1'-6"

5"

2½"
12" 2990 N.T.S.
17"

12"
23"

7½"
2'-0"

12"

17"
18"

5"
DRG.NO DATE

5"
9" 12"
C-1 TO C5 B101 TO B106 2-R JAN.-2024
NOTE:- WORKING DRAWINGS
B107 CB1:- 12" x 8" B108,B109 & B110
9" x 17" 12" x 23" (CONCEALED 9" x 17"
(12" DOWN TURN (18" DOWN TURN BEAM) (PORCH)

PROPOSED SINGLE STOREY STANDARD DESIGN OF PRIMARY HEALTH CENTRE


BEAM) BEAM)
(GOOD FOR CONSTRUCTION) TERRACE PLAN