Delivers a su perb view.

S ee for you rself.

●“DICOM” is the registered trademark or trademark of the National Electrical Manufac-


turers Association in the United States for its standards publications relating to digital
communications of medical information. ●Specifications and external appearance are
subject to change without prior notice. ●"SCENARIA","SCENARIA View","IntelliEC",
"CardioConductor","CardioHarmony", "HiMAR", "IntelliCenter", "riskPointer",
"fatPointer","guideShot" are registered trademarks or trademarks of FUJIFILM Healthcare
Corporation in Japan and / or other countries.●This product is a CLASS 2 LASER
PRODUCT.●3D images are processed by a medical workstation.

FCP-E500 Printed in Japan 2021-03-1K-(H)


Our iterative reconstruction method, Intelli IPV*, provides images which maintain their
Physics Model
natural texture even at high noise reduction rates and their excellent visibility even at low V i s u a l M o de l
The Physics Model is a technology
Physics
doses, and does not require a dedicated operation room or additional hardware. The Visual Model is a technology Model that uses FBP as a model and
reduces noise while adjusting
t hat controls image noise
Furthermore, by applying a low dose, the anode heat capacity is equivalent to 45 MHU Visual the texture from high frequencies
and image quality by iterative Model to low frequencies at a uniform
(converted value). processing based on statistical Object Statistical ratio, achieving a texture close
Model Model to that of FBP.
Projection
* IPV stands for Iterative Progressive reconstruction with Visual modeling. model, object model, and physics
Image
Object Model Statistical Model
model.
Models morphological Noise reduction is performed by
information changes to statistically evaluating X-ray-derived
c o n t ro l t h e s i z e , s h a p e noise and circuit system noise.
Achieving natural visibility with dose reduction and position of a structure.

Improvement of Low-contrast Detectability


Intelli IPV significantly reduces noise and improves low-contrast detectability while maintaining image texture
quality especially in the head region where low-contrast detectability is important.

SCENARIA View
New
Conventional iterative reconstruction
Compared to FBP
(Filtered back projection) Low-contrast
New
Image noise reduction rate detectability

90%
up compared with FBP
*

200%
to
up
to
FBP (Filtered back projection) DOWN
FBP Conventional iterative reconstruction Intelli IPV
Dose reduction rate

83%
up
to

DOWN
Intelli IPV
IntelliEC Plus (combination of auto exposure control and iterative reconstruction)
Normalized NPS ( Noise power spectrum)

0.05 The tube current is continuously modulated in 3D direction to obtain an image that achieves the target SD. When
modulating the tube current, it is possible to set scanning conditions that optimize not only conventional iterative
While adjusting the texture at a uniform ratio from 0.04
FBP (Filtered back projection) processing but also Intelli IPV characteristics.
h i g h f r e q u e n c y t o l o w f r e q u e n c y, t h e p h y s i c a l Conventional iterative reconstruction
0.03 0 200 400 600 mA
properties that affect visibility are made as close as Intelli IPV
possible to FBP. 0.02

0.01 Noise reduction


ratio by iterative
reconstruction
0 0.2 0.4 0.6 0.8 1 1.2
Frequency [Lp/mm]
Scanning iterative
reconstruction

Normal AEC
IntelliEC Plus
Low Medium High Target SD 12
frequency frequency frequency
*Images and processing performed by SCENARIA CT system.

*Scanning the lung field


Image Gallery

Tube Voltage : 100kV


Iodine concentration :
304.6mg/kg
FBP Intelli IPV FBP Intelli IPV

SCENARIA View
FBP Intelli IPV

FBP Intelli IPV

FBP Intelli IPV

FBP Intelli IPV FBP Intelli IPV


Advanced Funct ion
HiMAR Plus CardioConductor CardioHarmony
It reduces metal artifacts by applying iterative calculations. The reduction in intensity can be selected according CardioConductor is the function which tracks heart After image acquisition, CardioHarmony automatically*
to the ROI and the clinical indications of the examination. rate range during the patient's breathholding practice selects the phase of the cardiac cycle possessing the
and automatically calculates imaging and image minimal amount of cardiac movement as the optimal
reconstruction parameters based on the cardiac data cardiac phase. Search times for the optimal cardiac
collected*. For imaging parameters, it is possible to phases, which is a bottleneck in the workflow of
Back Metal chose from "Auto", which focusses on ease of use, or cardiac CT, can, therefore, be significantly shortened.
"Manual", which allows free customization. *The automatic selection must be checked and may be adjusted, if
projection extraction *The operator may need to perform checks, settings, and adjustments. necessary, by the operator.
Original Metal
image image

Scanned Corrected
RawData RawData

Artifact Estimation Artifact Correction


Processing Processing VR RCA LAD

In this case the heart rate changed


Amount of from 37 to 72 bpm during scanning,
movement which makes it difficult to find
the stationary phase. The optimal

SCENARIA View
Optimal Cardiac
cardiac phase can be found easily
Optimal
cardiac phase cardiac phase phase by using CardioHarmony.
(Systole) (Diastole) (%)

*Images and processing are performed on the SCENARIA CT system.

IntelliEC Cardiac
The tube current modulation can be set for up to 2 phases and, in doing
so, it is possible to reduce the dose in cardiac CT examinations.

(mA)

250

50 Reconstruction cardiac RCA LAD


phase 75%
75 (%)
120kV, 0.35s/rot, Pitch 0.17, Intelli IP Lv3
FBP HiMAR Plus
*Images and processing are performed on the SCENARIA CT system.

IntelliCenter
Since the patient table moves up to 200mm laterally, it
0.42
is possible for the operator to position the ROI (Region
Of Interest) close to the center of the scan field without 0.38
touching the patient. If the region of interest is offset 0.36
from center of the scan field, then a post recon is 0.33

required to align to the reconstruction center. However,


by using IntelliCenter, that process can be skipped*1 and, Center
as a result, is expected to shorten examination time*2. In
general, it is expected to improve the spatial resolution 0.45 Max.
of the image by setting the scan area at the center of
rotation. The integration of table lateral movement and tilt
0.42 200mm
scanning also allows more flexibility in head examination. 0.38
CTDIVol is reduced by a minimum of 8.0%* 3 when the 0.36
head is shifted near the center of rotation and the dose Off-Center
compensation filter is switched from standard to small. (50mm)

FBP HiMAR Plus *1 Limited to cases where the scan area can be positioned at the center of the FOV by lateral movement.
*2 The time starting from the patient lying on the table and to the end of the scan.
*3 Scan parameters: Tube voltage 120kV, Tube current 300mA, Scanning time 1.0s, 0.625mm×32rows
O t her F u n c t i on s Comfort
Touch Vision provides a comfortable Breath Guide helps the patient with visual
Dose Management
1 2
examination for both patient and operator guidance during the scan
The large monitor at the front of the gantry ensures Breath Guide displays are mounted at three locations
DICOM SR
smooth scan guidance to the patient. 11 languages on the gantry to indicate breath hold timings to the
are installed to guide breath hold during the scan. patient during the scan. These can be seen from any DICOM SR Simple Dose Report Simple Dose Report
patient position. The guidance is displayed by 11
Using the DICOM standard, Dose information can be
languages selectable with auto-voice.
it is possible to transfer dose transferred to PACS etc.
information as a DICOM a s a s e c o n d a r y c a p t u re
Structured Report (DICOM SR) image.
to PACS etc.

PACS
Operation buttons are located on both sides of the monitor to enable easy
access for the operator.

Breath Guide Breath Guide 3-Unit Design (Compact Space)


(11 languages selectable) (for children)
The entire system comprises just three components*;
g a n t r y, p a t i e n t t a b l e a n d o p e r a t o r c o n s o l e . N o

SCENARIA View
additional units, such as system transformers,
are required, so the space in the CT room can be
maximized for clinical use.

* For power supply voltage 380/400V

Eco mode
Eco mode has two functions (On-time Standby and Off-time mode).
The On-time Standby function controls the units mounted in the gantry, thereby reducing power consumption by
up to 48% compared to Eco mode OFF.
The Off-time mode cuts off the electricity but maintains the operating readiness of the detector. With Off-time
mode, the power consumption during standby is reduced by up to 60% compared to when not in use.