Professional Documents
Culture Documents
Bri DB 1100
Bri DB 1100
Applic a t ions
* Medicine/Pharmaceutical Industry
* Environment Monitoring
* Commodity Inspection
* Food Inspection
* Agricultural Chemistry
* Teaching in Colleges & Universities
* Metallurgy
* Geology
* Machine Manufacturing
* Petrochemical Industries
* Water and Waste water Labs
* Food and beverages Labs
Pe rfe c t ion in
La bora t ory Sc ie nc e
M ic roproc e ssor U V -V I S Double Be a m MODEL NO- BR-DB-1100 M ic roproc e ssor U V -V I S Double Be a m
Spe c t rophot om e t e r Spe c t rophot om e t e r
TECHNICAL SPECIFICATIONS
Ÿ Wa v e l e n g t h Ra n g e : 190-1100nm
Ÿ Sp e c t r a l B a n d w i d t h : 1nm Quantitative
Ÿ Optical System : Double Beam, Blazed Holographic Grating (1200 lines/mm) 1. Coefficient Method
Ÿ Wavelength Accuracy : ±0.5nm 2. Standard Curve Up to 10 Standard sample may be used to establish a
Ÿ Wavelength Repeatability : ≤0.2nm curve. Four methods for fitting a curve through the calibration points :
Ÿ Wavelength Setting : Auto, Resolution 0.1nm
Linear fit. Linear fit through zero, Square fit and cubic fit.
Ÿ Photometric Range : 0~200%T, -4~4A, 0~9999C
Ÿ Photometric Accuracy : ±0.002 A (0~0.5A), ±0.003A (0.5~1A), ±0.3%T (0~100%T)
Ÿ Photometric Repeatability : ≤0.001 A (0~0.5A), ≤0.002A (0.5~1A), ≤0.2%T (0~100%T)
Ÿ Stray Light : ≤0.05%T(220/360nm)
Ÿ Scan Speed : High, Medium, Low. Max.3200 nm/minute DNA/Protein Test
Ÿ Baseline Flatness : ±0.0015A Concentration and DNA purity are quickly and easily calculated: Absorbance
Ÿ Stability : ±0.001A/h (500nm,0A) rations: 260 nm / 280 nm with optional subtracted absorbance at 320 nm. DNA
Ÿ Noise : ≤0.2%T/3min (250/500nm,0%T); ≤0.5%T/3min (250/500nm,100%T) concentration = 62.9XA260-36.0XA280 Protein concentration = 1552xA260-
Ÿ Sample Compartment : 10mm Pathlength Cuvette 757.3xA 280
Ÿ Detector : Silicon Photodiode
STANDARD CONFIGURATION
Ÿ Lamps : Tungsten Lamp & Deuterium Lamp (Pre-aligned)
Glass Cell : 4 Nos.
Quartz cells : 2 Nos. Ÿ Display : Graphic LCD (320*240 Dots)
Instruments Cover : 1 No. Ÿ Keypad : 30-key Alphanumeric Membrance Keypad
Software CD
USB Cable
: 1 No.
: 1 No. Ÿ Output Port : USB Port Wavelength Scan
Operational Manual : 1 No. Ÿ Printer : Mini Serial Printer; PC Printer
Software Manual : 1 No.
1. The wavelength scan intervals are 0.1,0.2,0.5,1,2,5 nm
Software key : 1 No. Ÿ PC Software : UV Analyst Scanning Software 2. High, Medium and low scan speed are available. They vary from 100 to
Ÿ Power Requirements : AC 90-250V, 50/60Hz 3600 nm/min
Ÿ Dimension : 545x468x245mm 3. Wavelength are scanned from high to low so that the instrument waits
Ÿ Weight : 18kg at high WL. And it minimizes the degradation of UV sensitive samples.