Set 2A - Day 2 (Design)

You might also like

Download as pdf
Download as pdf
You are on page 1of 31
aN TAP NATSER @tapnatser ue Facebook. con/tapnatser https ARCHITECTURE LICENSURE MOCK EXAMINATION SET 2A Day 2 (Design) DESIGN PROBLEM NO. 1 - LOGISTICS CENTER EXPANSION ty Design Problem. A Filipino entrepreneur named Businessman A is planning to expand his business in Santa Rosa, Laguna. To do this, he contacted his former college classmate named Businessman B who is now a big-time businessperson in the US. Since Businessman A had already established a quite large network locally and Businessman B is also doing good internationally, they decided to form a joint venture company to expand ‘their business, especially in logistics operations. They thought that since Santa Rosa City in Laguna is a growing industrialized city, it is a good opportunity to expand their logistics center there. The joint venture was ‘then registered with SEC under the name Phil€x Logistics Inc. The plan is to expand the lot and facilities established by Businessman A in Sta. Rosa twice its size. This existing development is in a 1.20-hectare lot facing ‘the Sta. Rosa-Tagaytay Road. Another lot similar in size, slope and shape situated on the left of the existing lot was acquired to serve as the ‘expansion of the existing development. The development and facilities in the existing lot includes the following: A. Commercial center with an appliance depot in a @.42-hectare land area facing the road. Included in this land area are the 12m wide driveway on the left side, a 43m x 688sqm front parking space, a long 5m softscape strip on the right, a Two-Story appliance depot and a one- story commercial storage. 1. The Two-Story appliance depot has a footprint of 43m x 25m and is sited after the front parking space. The ground floor contains 8@@sqn customer space and 275sqn support spaces such as the comfort rooms, cashier’s office and package area. The second floor contains S@@sqn customer area and 575sqm office space. 2. Behind the appliance depot is the conmercial storage measuring 1032sqm having the same width as the depot and front parking space. This storage facility contains a number of racks for the storage of different items especially appliances. 3. A 5m deep buffer space separates the commercial storage from ‘the industrial area. 4, The 5m wide softscape to the right will be planted with trees to block noise and air pollution fron the surroundings. Tt will also serve as a relaxation space for the employees of the commercial center. Concrete benches measuring 60mm x 1200nm are placed on this area. 5. The 12n-wide driveway on the left connects to another driveway with the same width in the industrial area. B. The industrial area is a portion of the existing lot with a land area measuring 6@m x 4800sqm inclusive of the 12m driveway to the left, a 2-Story logistics center fronted by an unloading area and Sm wide softscape strip around. 1. The 12m wide driveway has a length of 8n which connects to the residential area at the rear portion of the existing lot. 2. Along the driveway is an 8m x 70m unloading area in front of the logistics center. Page 1 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) qm. mt. 3. The logistics center building footprint measures 35m x 7m. The second floor measures the same. 4, Softscape areas/strips surround the logistics center on three of its sides. €, The 3000sqn residential area at the rear portion of the existing lot includes a seni-residential and office building, a front open space and 5m wide softscape around. 1, The semi-residential and office building has footprint of Son x 150@sqn with two stories. 2. The front open space that measures 55m x 15m includes softscape elements, a 10n x 12m pool and parking spaces. This open space is connected to public road through the 12m wide driveway provided in the industrial and commercial area. 3. Sn-wide softscape strips surround the semi-residential and office building. Site Features. The frontage of the existing rectangular lot is 60m. Its area is 1.20 hectares with a 1% downward slope towards the back. It is bounded fon the North, the longer side, ‘along line 1-2 by a private lot; on the East along line 2-3 by the 15n-wide Sta. Rosa-Tagaytay Road; on the South along 3-4 by another private lot which is acquired for the expansion; and on the West along line 4-1 by another private lot. The new lot for expansion is on the left with the same size, same slope and same shape. The existing lot is considered by the O80 as composed of three zones - commercial, light industrial and residential - which must follow the separate provisions of ‘the NBC according to its zone requirements. With the new acquired lot on the left, each area/zone will double in size. Design Objectives. Since this is an expansion of the existing facilities, the RLA hired for the project is tasked to determine how much development is allowed for expansion. No new constructions and renovations are to be done with the existing lot and facilities. The RLA will consider the new combined lot size of each zone in computing the development requirements for each of the zone. This will be his basis for the designing new structures in the added areas. <<< Nothing Follows >>> Page 2 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Nt Set 2A Day 2 (Design) DESIGN PROBLEM NO. 2 - THREE-STORY COMMERCIAL BUILDING ar II. Design Problem. A Filipino lawyer was encouraged to venture in real estate business. With his savings, he plans to build a conmercial building in his hometown in Sta. Rosa, Laguna. This new building will house rentable conmercial spaces and his law office. The busy lawyer hired an architect to design the building and manage its construction. The architect must consider the following space requirenents for this venture: a. At ground level, the following spaces are required: i. A rentable commercial space measuring 149.5sqn inclusive of a 6sqn comfort room on rear right corner. On the front right comer is the staircase area measuring 3m x 10.5sqn. The staircase area and the commercial space forms a 1@n-deep rectangular footprint. 44, The 10n-deep non-commercial space at front consists of the parking space with a 2.2n-wide walkway on the left side connecting the road sidewalk to the staircase area. iil. A softscape strip is provided at the rear with the width equal to ‘the require minimum rear setback. b. At 2" floor level, the following requirements are needed: i. A 169sqm square law office on the left side. 44, A 3m x 6.5m comfort room and storage space on the right rear corner. ii. A 3n x 6.5m stair and circulation area on the right front corner. iv. A 2m wide front balcony spanning fron left to right. This balcony is offset fron the road by the minimun required front setback. v. The rear setback is maintained in all levels. c. At 3° floor level, same space requirenents as the 2% floor except that the law office will become a rentable conmercial space. Site Features. The project site is a rectangular inside lot facing a 15m city road, located in a mediun-density commercial area in Sta. Rosa, Laguna. The lot measures 352sqn. The lot is bounded along line 1-2 by a private lot; along line 2-3 by a private lot; along line 3-4 by a private lot; and along 4-1 by a RROW. The lot slopes at 3% downwards toward the north-west direction. The technical descriptions of the lot are as follows: UNE BEARINGS | STANCE 1-2 | nesssve | 200m esr | 160m sexasew | 200m a1 | eeseorw | 1600 Design Objectives. Given the busy schedule of the lawyer-businessman, he” doesn’t have time to deal with all the administrative roles for the project. Because he has a huge amount of savings, release of money is never an issue. The architect must consider this scenario and must do his best to provide the best design for the client. He must also consider that the lawyer- businessman is a proud Filipino and wants a design that really represent ‘the local culture. The client is also an active member of WhF-Philippines so the architect should consider the best eco-friendly materials and building methods. <<< Nothing Follows >>> Page 3 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION aN Set 2A Day 2 (Design) DESIGN PROBLEM NO. 3 - TWO-STORY ADMINISTRATION BUILDING 2 Ir. Design Problem. After 20 years since the first Administration Building was built, the Department of Education (DepEd) has now approved the total rehabilitation of the Baguio Teachers Camp. As part of the rehabilitation of this historic site, additional buildings are proposed to be built within the camp. One architectural firm was hired to design and manage the construction of an extension administration building (Building 2) which will be called the Building Science Center. The firm is assigned to provide a design considering the following requirements: a. A multipurpose hall with an area of 840 sqm and front width of 4am. Accessory to this hall are two large storage rooms for keeping necessary equipment and materials. The two adjacent storage rooms are on the west side of the hall. b. Storage 1 (255sqm x 17m) and Storage 2 (17@sqn x 10m) are accessible through a connected rear platform measuring 3m wide and 77m long. The hall and the comfort room are also adjacent to this platform. €. The longer side of the platform is serviced by a rear multipurpose open space where vehicles can park, load or unload. This open space measures 315@ sqn x 105m. d. A 200 sqm x 20m business center is located on the right side of the lot. e. An entrance lobby measuring 12m wide and 11m deep is located between the business center and the multipurpose hall. It contains the staircase leading to the 2% floor spaces. An adjacent 72 sqn comfort roon also separates the hall and the business center. #. An entrance deck measuring 104 sqm x 26m provides the front space of the building facing the main road. The side deck of the same width and 2en long is on the eastmost portion adjacent to the business center. The decks are connected and accessible by a series of steps from the main and secondary road. g. Beside one of the storage rooms is a 6m driveway connecting the rear open space and the main road. A 2m wide, 3@n long planting strip separates the driveway and the west adjacent lot h. On the 2" floor, a 12m x 11m circulation area containing the stairwell, hallways and waiting area is provided right exactly above the entrance lobby. A 12m x 6m comfort roon is connected to it. The admin office measuring exactly the same as the business center is adjacent to the circulation area and comfort room. On its side facing the secondary road, @ 4m x 20m balcony is provided. This balcony is on top of the side deck on the ground floor. 4. The remaining front and side yards are planted with grass and other softscape elements. Since these yards are large and accessibly from the roads, benches are provided near the sidewalk for public use. k. The FFL of the lobby, business center, comfort room, multipurpose hall ‘and storage rooms is 600mm above the main road sidewalk while the platforms and decks 150nm lower than the rest of the ground floor spaces. Site Features. The project site is a small camp located within the larger Baguio Teachers Camp (BTC). The 15m main road traverses E-W while the 12m secondary road runs N-S. Their intersections are assumed to be perpendicular. The site is located on the west side of the secondary road and the north side of the main road. The frontage of the lot measures 105m. The intended building use is classified as Group C - Education and Recreation, Division C-1 other types of government buildings while the lot is zoned accordingly. The site slopes downward at 2% towards the rear side of the lot. The main road sidewalk is assumed to be level while the secondary Page 4 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION nN Set 2A Day 2 (Design) Sidewalk follows the contour of the site. The camp has its own planning ordinance requiring minimum setbacks along public spaces or roads to be 6m. Property lines coinciding with other private properties must follow the NBCP-required setbacks. Design Objectives. The firm is hired to design a welcoming architectural piece especially for building science teachers and students coming to the Camp. The building must incorporate in its architectural features not just ordinary building materials and methods but also the potentials of new and advanced construction technology. As much as possible, the building materials used must be proudly Pinoy. The design should also inspire the public to use passive design strategies especially for the harsh tropical climate. Since it is in Baguio, the building is expected to be naturally ventilated all throughout its spaces. << Nothing Follows >> Page 5 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) DESIGN PROBLEM NO. 4 - TWO-LEVEL SINGLE DETACHED RESIDENTIAL HOUSE ar ct, wv. You were hired by Delos Santos family to design their house in their newly bought site located in Bifian, Laguna. To describe the family, Mr. Delos Santos is a real estate broker who likes woodworking. His wife, Mrs. Delos Santos is an accountant who likes gardening and collecting native or indigenous plants. Their two daughters like weightlifting with the older fone having won multiple local competitions. The siblings are very close to each other. The project site is a corner lot in an exclusive executive subdivision in Bifian, Laguna, cornering the streets of Sampaguita which runs N-E and Rosas which runs S-£ . Both roads serve as the primary roads for this project. The following lot descriptions were given: [Line Pe [15.00m Line 2-3. | § 354-44" QO"E 121.55m Line 3-4 | § 134-48" 00" E | 02.50m 525d 29°00" W a 00° W12.00m N38a-44°00" u (ne 6-1 | Line 1-2 4s bounded by a private lot, Line 2-6 by road lot and Line 6-1 by a private lot. The site slopes downward towards Rosas St. by 2%. Fron the multiple.interviews, the summary of their requirements are as follows a. The family likes the famous Francisco Mafosa and wants a house that embodies Filipino culture in terms of materials and aesthetics. Wood parquet is the preferred finish for the bedrooms. The facade shall incorporate wood finishes and natural stones which will complement the surrounding gardens. b. A covered and paved carport is desired on the northern corner of the lot, measuring 6m x 5.5m and abutting Sampaguita street. As much as possible all remaining open spaces will be permeable gardens. Adding to the paved carport, a paved 1.5m x 15 sqm wide path on the front yard is provided to serve as path from the carport to the living area. c. The ground floor will house the 3@sqm enclosed woodworking area on the northwest, a living room'on southeast, dining room and other areas. d. The second floor will have a master bedroom facing both the roads. A shared bedroom for the two daughters is provided along with an adjacent 34 sqm weightlifting room on the NW side. The rest will accommodate the hallway and stairs. The second floor will maximize the allowable building footprint. The architect is expected to satisfy the needs and requirements of the family, considering the requirements of the code and the subdivision. << Nothing Follows >> Page 6 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set_2A Day 2 (Design) DESIGN PROBLEM NO. 5 ~ TWO-STORY DUPLEX HOUSE I In. III. Design Problem. Two couples decided to live next door because they have all been F.R.I.£.N.D.S. since high school days. The first couple is Ross, a paleontologist and Rachel, a fashion executive. The second couple is Monica, a chef and Chandler, a transponster. The four decided to build a Two-Story duplex house so they can live right next to each other. They will equally share a lot they bought in a subdivision where the BHL is 3 stories. Because they are all friendly, they really expect a lot of old friends coming over to their homes. They also like to throw parties and make fun of themselves. Through their friend Phoebe, they hired a local architect named Teddy Boy Mosby to design and manage the construction of ‘the house. Their close friend, Joseph Francis Tribbiani Jr., explained all ‘the requirements which are as follows: a. At front yard, 2-car paved carport is expected for each unit. Each car slot is the minimum required as per the code. b. The ground floor of each unit measuring 69sqm will contain the foyer, stairs, dirty kitchen, living room, powder room, dining room and storage under the stairs. The entrance foyer is 2m deep with 6sqn area. The front of the foyer will be landscaped with plants and will have permeable pavement. The carport can be totally paved which was allowed by the 080. ¢. The second floor of each unit follows the footprint of the ground floor where above the foyer is a balcony of the sane size. This is good especially since it faces the east. The second floor will contain the master bedroom, another bedroom on west side, hallway and the balcony. d. The architect must maximize the lot. The side and rear yard will be a mix of softscape and hardscape. Site Features. The project site is an inside lot in a subdivision in New York, Cubao, Quezon City. It measures 16m x 288sqm with 18m frontage. The site is relatively flat and has a good front view facing the east. Design Objective. Teddy Boy Mosby, the architect, is tasked to follow the said requirements. He should also consider his clients’ profiles. Monica is obsessed in cleaning. Chandler likes to dance. Ross likes to collect stuff while Rachel likes fashion. The two couples expect their homes to be ‘the place where they can be confortable with themselves. << Nothing Follows >> Page 7 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) x INSTRUCTION: Choose the correct answer for each of the following questions. Shade only one answer in the provided answer sheet. ERASURES ARE STRICTLY NOT ALLOWED. Situation @1 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about DEVELOPMENT CONTROLS. 1. What is the maximum building footprint that can be built on the site without any firewall? a. 5044 sqm c. 3780 sqn b. 4410 sqm d. 3158 sqm 2. What is the BHL for this project? ° a. 30.00n cc. 10.00n b. 15.00n d. 36.00m 3. What is the maximum firewall length allowed for this project? a. 234m . 165m b. 330m d, 280.5m 4, What is the maximum gross floor area for this project? a. 9450 sqn c. 22050 sqn b. 6300 sam d. 15750 sqm 5. Which of the following GFA is considered overdeveloped? a. 6300 sqn c. 15750 sqn b. 22050 sqm d. 9450 sqm Situation 92 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2, and about SPACE PLANNING. 6. Which of the following type of office layout is most ideal for collaborative work? a. cellular type ¢. open type b. combination type d. coworking space 7. which office furniture occupies the largest space? a. typical filing cabinet c. computer desk b. executive desk d. mobile pedestal cabinet 8. Which of the following type of office layout is considered highly hierarchical? a. cellular type c. open type b. combination type d. coworking space 9. What do you call an office table unit used by multiple users grouped together? a. shared c. workstation b. computer d. freestanding 10. What is typically installed between two conference rooms to combine the ‘two spaces for single use? a. Accordion door c. Mobile office wall b. Sliding partition d. Operable wall partition Page 8 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) Situation @3 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about ESTIMATES. 11. What is the approximate volume of loose soil needed for the multipurpose hall? The hall flooring is finished with polished concrete slab 200mm thick. The soil to be used is assumed to be conpactible up to 25% of its loose volune. 2. 800 - 850 cu.m. c. 750 ~ 800 cu.m. b. 550 - 600 cu.m. 4. 680 - 650 cum. 12. What is the concrete volume required to for the multipurpose hall flooring slab? a. 840m? c. 200m b. 168m d. 158m 13. How many 60x69 tiles is required for the entrance lobby considering 5% wastage allowance? a. 404 pcs c. 367 pes. b. 132 pes d. 386 pcs 14, What is the approximate volume (m') of terrazzo mix needed for the second- floor balcony with 1” thick terrazzo overlay? a. 2.90 c. 2.10 b. 3.50 4. 1.80 45. How many CH8s are needed raise the 2m landscape strip near the driveway? The Single-layer CHB around the strip will confine the soil serving as the landscape bed. No foundation is needed. a. 180 c. 160 b. 64 4. 250 Situation @4 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about SPACE PLANNING. 16. How many occupants can be accommodated in the business center if the designed ceiling height is 2.7m and the center is considered as a workshop space? a. 40 c. 55 b. 50 4. 45 17. what is the required minimum total exit width serving the business center? a. 900mm c. 800mm b. 60@nm d. 750mm 18. A gang chair is most commonly placed where? a. Inside the office c. In the lobby b. Inside the conference roon d. In a storage room 19. Which of the following is not considered a support space in an office setting? a. printer station c. private office b. filing room d. pantry 20. what do you call the small meeting rooms near a larger meeting room? a. pantry rooms c. semi-meeting rooms b. break-out rooms d. meeting rooms E Page 9 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) Situation 95 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about SITE DEVELOPMENT. 21, What do you call a row of plants, trees or shrubs aimed to protect a building from the damaging force of winds? a. sun breaker c. wind wall b. wind break d. wind hedge 22. Which type of soil is best for building foundation? a. clay cc. loam b. sand d. bedrock 23. What do you call the raised edge of a sidewalk? a. zocalo c. deck b. gutter d. curb 24. Which of the following trees is not ideal for landscaping in the Philippines? a. Mahogany c. Narra b. Molave d. Banaba 25. Which of the following is not part of a promenade? ‘a. benches c. planting strip b. vehicular road d. walkway Situation @6 - The following questions relate to Design Problem No. 3, Two-Story ‘Administration Building 2 and about ARCHITECTURAL INTERIORS. 26. What do you call the vertical component that supports the floor panels in a raised office flooring? a. strut c. rail b. track -d. pedestal 27. Which is the simplest and the most economical method of frosting a glass wall partition? a. acid etching c. vinyl film b. sand blasting d. PE film 28. which glass thickness is conmonly used for frameless partitions in offices? a. 12mm ce 6mm b. 8mm d. 20mm 29. In office setting, high pressure laminates are most appropriate for what? a. Flooring finish c. ceiling finish b. furniture finish d. chair finish 30. Which of the following is used to make a single workspace partially enclosed? a. cubicle partition c. full height glass partition b. operable wall d. sliding door Situation 07 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about STRUCTURAL CONCEPTUALIZATION. 31, What is considered as a subbase in a concrete slab on fill? a. vapor barrier ¢. compacted soil b. gravel d. concrete slab Page 10 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) 32. Which of the following is not used as a connection of structural steel frames? a. rivet c. weld b. bolt d. screw 33. Which concrete test is the most destructive? a. concrete core test c. cylinder test b. rebound hanmer test d. slump test 34, Considering the shape and proportion of the 2% floor comfort room, the suspended slab will most likely act as what? a. one-way slab c. three-way slab b. two-way slab d. four-way slab 35. What type of slab is directly supported by columns without the use of beans and girders? a. ribbed slab c. two-way slab b. flat slab d. thin shell Situation @8 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about STRUCTURAL CONCEPTUALIZATION. 36. Which of the following structural system has the widest span? a. one-way slab c. waffle slab b. two-way slab d. arches 37. Which of the following building shape has a reentrant corner? a. Square c. Cross b. Rectangle d. Circular 38. Bracing elements are constructed or installed : a. diagonally c. vertically b. upright d. horizontally 39. Which building size has largest swaying or shaking movement near an earthquake epicenter? a. low-rise c. high-rise b. mid-rise d. all the same 42. What do you call this phenomenon where the soil temporarily becomes a quicksand due to an earthquake? a. softening c. settlement b. liquefaction d. soil swelling Situation @9 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about SITE DEVELOPMENT. 41, The lot plan is prepared by which professional? a. civil engineer c. geodetic engineer b. architect d. geotechnical engineer 42. Which is the simplest dust control method in a construction site? a. tillage c. vegetation b. spraying water d, mulching Page 11 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) 43. Soil filling and backfilling shall be done in layers with maximum thickness of which must be compacted every layer. a. 4 ces b. 6” d. 10” 44. Which of the following is not a hardscape element? a. driveway c. topiary b. pavers d. benches 45. Which of the following is considered as a “greenfield” site? a. grazing field c. abandoned mining site b. old airbase d. old burial places Situation 10 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about ARCHITECTURAL DESIGN. 46. Which type of section drawing has a section cut along the shorter axis of the building? ‘a. Longitudinal c. Detail b. Full d. Transverse 47. Which provision in the IRR of RA 9266 requires the architect to affix his seal on all his architectural plans, drawings, specifications and all other contract documents? a. Rule IV, Section 19 c. Rule III, Section 19 b. Rule IV, Section 2@ d. Rule III, Section 2@ 48. What is the standard rough-in distance of water closet from the back wall? a. 6” ices b. 15” ere 49. Which of the following is not considered as an architectural drawing? a. detail of counter c. detail of door b. detail of truss joint 4. detail of window 50. Which type of roofing is the most ideal for windy areas? a. hip roof c. shed roof b. gable roof 4, flat roof Situation 11 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about SITE PLANNING. 51. What do you call the power of the government to take and appropriate private property to public use with reasonable compensation? a. poner of public domain c. power of acquisition b. poner of public usage d. power of eminent domain 52. Foundation can rest on the following except , a. bedrock ¢. natural grade b. compacted fill d. earth fill 53. What do you call the determination and placement of reference points and markers that guides the construction? a. stake-out c. as-built survey b. batter boards d. Line-up Page 12 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) 54, What type of survey is needed when a single lot needs to be split into multiple lots with individual titles? a. relocation survey c. original survey b. subdivision survey d. split survey 55. If a tree ina lot leans to an adjacent property and poses a danger to property and lives, who shall pay for its renoval? a. lot owner b. adjacent lot owner c. shared by the owners of the lot and adjacent lot d. building owner Situation 12 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about ESTIMATES. 56. How many bags of cement is needed for the 6” concrete slab on fill for the ‘two storage rooms using Class B concrete? a. 574 c. 64 b. 479 d. 425 57. What is the approximate number of gypsum boards needed for a flat drop ceiling on storage room 1? a. 70 - 85 c. 95 - 100 b. 85 - 95 d. 10 - 110 58. How many pails of latex paint are approximately needed for the interior walls of the business center, with 2 coats and a ceiling height of 2.8m? Paint coverage per gallon is 20 sqn. a. 5 c 4 b. 2 d. 17 59. How many cu.m. of gravel is needed for 5* thick slab of the multipurpose open space? Assume that 60% of the open space will be paved. a. 1898 c. 237 b. 119 d. 2133 60. Refer to previous question. How many cu.m. of sand is required for the same slab? a. 1898 ice 237, b. 119 d. 2133 Situation 13 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about STRUCTURAL CONCEPTUALIZATION.. 61. What is the absolute minimum camber of reinforced concrete beans? a. 6rm c. 10mm b. 4am d. 18mm 62. The proper location of a rebar splicing in an RC column is where? a. lower portion ¢. upper portion b. middle portion d. column and beam joint 63. Trimmer bars are used for which structural component? a. grade beams c. slab openings b. footing tie beams d. cantilever beams Page 13 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) 64. What do you call an above-ground column that rests on a slab or beam instead of another colunn? ‘a. drop column . Composite column b. planted column d. moment column 65. No. 6 deformed steel bar is equivalent to rebars. a. 10mm €. 16mm b. 12mm d. 20mm Situation 14 - The following questions relate to Design Problem No. 3, Two-Story Administration Building 2 and about SITE PLANNING. 66. What is the color of institutional zones in a comprehensive land use plan? a. blue c. red b. violet d. yellow 67. Septic tanks should be desludged every 2 a. year c. 10 years b. 2 years d. 5 years 68. Site selection and analysis is part of which architectural service? a. regular design services c. predesign services b. specialized architectural d. post-construction services services 69. Which of the following construction does NOT necessarily need a specialty contractor? ‘a. swimming pool c. wastewater treatment plant b. septic tank d. STP 78. What type of court is bounded by building lines on all of its sides? a. inner c. through b. open d. yard Situation 15 - The following questions relate to Design Problem No. 1 - Logistics Center Expansion and about CODE COMPLIANCE. 71. Using the combined lot area, what is the existing lot occupancy of the commercial area? a. 25.1% c. 17.6% b. 50.2% d. 22.7% 72. Considering the expanded industrial lot, what is the existing lot occupancy of the industrial area? a. 84.1% c. 25.5% b. 31.4% d. 51.1% 73. Using the existing developed lot area, what is the existing lot occupancy? a. 82.5% c. 61.5% b. 50.5% d. 45.2% 74, What is the required minimum width of the front yard of the commercial area? a. 5.00m c. 16.00m b. 4.50m d. 43.00m Page 14 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION in Set 2A Day 2 (Design) 75. What is the use or occupancy classification of the structures in the commercial area? a. C-1 c. E-2 b. C-2 d. 1 Situation 16 - The following questions relate to Design Problem No. 1 - Logistics Center Expansion and about ARCHITECTURAL INTERIORS. 76. Partition walls in a warehouse are also called a. firewalls c. drywall b. denising walls d. occupancy wall 77. Which of the following is an ideal flooring for a warehouse prone. to chemical spills? a. marble tiles ¢: polished concrete b. porcelain tiles d. epoxy flooring 78. According to BP 344, what should be the minimum clear width of doors for toilet cubicles? ‘a. 920mm c. 700mm b. 80anm 4. 65@nm 79. What is typically used for wainscoting a public comfort room? a. drywall c. polished concrete b. ceramic tiles d. epoxy 80. What type of lighting is specified for warehouses? a. high bay lights c. down Lights b. troffer Lights d. flood lights Situation 17 - The following questions relate to Design Problem No. 1 - Logistics Center Expansion and about STRUCTURAL CONCEPTUALIZATION. 81. What rebar thickness is typically used for CHB wall reinforcement? a. Sm cc. 20mm b. 10mm d. 12mm 82. What is the minimum slump used for reinforced concrete beams? a. 150mm ¢ 5@nm b. 10mm d. 75mm 83. JackBilt is a known manufacturer of which product? a. precast concrete c. roofing b. steel products d. power tools 84, Which type of Portland cement is high early strength? a. Type I c. Type IIT b. Type IT d. Type IV 85. What material is commonly used for framing warehouses? a. wood c. steel b. reinforced concrete d. aluminum Page 15 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) Situation 18 - The following questions relate to Design Problem No. 1 - Logistics Center Expansion and about SITE DEVELOPMENT. 86. Which of the following agency can issue a tree-cutting permit? a. Office of the Mayor c. CENRO b. Barangay Hall d. DPHH 87. According to BP 344, what is the minimum headroom height for walkways? a. 200m c. 2.5@m b. 2.20m d. 1.80m 88. In the Water Code of the Philippines, what is the minimum easement for rivers in urban zones? a. 3.00m c. 20.00 b. 5.00 d. 1.5@m 89. What is the minimum parking slot dimensions for an articulated truck? a. 3.60m x 12.00n . c. 3.60m x 18.0em b. 3.00m x 10.0en d. 2.50m x 5.2m hat do you call the angle that the sun makes with the local horizon? a. azimuth c. latitude b. zenith d. altitude Situation 19 - The following questions relate to Design Problem No. 1 - Logistics Center Expansion and about STRUCTURAL CONCEPTUALIZATION. 91. What is typically specified minimum compressive strength in psi of non-load bearing CHBs? a. 350 c. 700 b. 500 +d. 250 92. What type of structural steel frame is ideal for warehouses? a. braced tube ¢. portal frame b. diagrid 4. space frame 93. In a reinforced concrete beam above ground, which of the following is the last to be removed? a. Soffit formorks ce yokes b. props d. vertical formorks 94. What is the maximum height of gravity retaining walls? a. 1.50m c. 5.0m b. 3.00m d. 7.00m 95. Which of the following column locations has the largest tributary area? a. perimeter c. interior b. corner d. planted Situation 20 - The following questions relate to Design Problem No. 1 - Logistics Center Expansion and about CODE COMPLIANCE. 96. What is the TGFA in square meters of the commercial area? a. 2150 c. 3182 b. 1032 4. 2107 Page 16 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION nN Set 2A Day 2 (Design) 97. What is the maximum firewall length allowed for the expanded commercial area? a. 38m c. 190m b. 221m d. 266m 98. What is the frontage of expanded conmercial area? a. 12.00n c. 60.00n b. 120.¢0m d. 70.00m 99. How many car slots are required for the existing 2-Story logistics center? a4 6 b.8 a5 100.What is the FLAR of the existing semi-residential and office building in relation to the expanded residential area? a. 0.25 c. 0.50 b. 1.00 d. 1.58 Situation 21 - The following questions relate to Design Problem No. 1 - Logistics Center Expansion and about ARCHITECTURAL DESIGN. 1@1.What is the typical maximum depth of residential swimming lap pools? a. 1.50m c. 1.20m b. 1.80n d. 2.10m 102.Which of the following shape is ideal for a lap pool? a. irregular c. rectangular b. circular d. oval 103.Which of the following grass is the cheapest? a. Blue grass ¢. Bermuda grass b. Carabao grass d. Korean grass 104. Which of the following components of a swimming pool is optional? a. water filtration c. skimmer b. water pump d. air blower 105.Wshat type of roof ventilation device is commonly used for warehouses? a. turbine ventilator c. soffit vent b. ridge vent d. box ventilator Situation 22 - The following questions relate to Design Problem No. 1 - Logistics Center Expansion and about CODE COMPLIANCE. 106.Using the provision of the code, what should be the minimum width of sidewalk fon each side required for the driveway? a. 1.20m c. 1.80m b. 1.50m d. 1.0 1.¢0m 1@7.What is the minimum required total window opening area for the 2% floor office space of the appliance depot, if not provided with artificial ventilation? a. 28.75sqn c. 32.4sqm b. 5.75sqm d. 57.5sqm Page 17 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) 108. Assume a Sm front’ and back setback for a new commercial structure on the added commercial area. Considering the natural slope of the site, where should be the EGE? ‘a. @.65m below the sidewalk c. 0.05 above the sidewalk b. 3,00n above the sidewalk d. at the sidewalk 109.What will be the minimum area of the unpaved surface area to be added so that the expanded conmercial area follows the most stringent USA requirement for any commercial zone? a. 565sqm c. 275sqm b. 842sqn d. 42@sqn 11@.What is the minimum open space required for the industrial area of this project? a. 30% of TLA c. 50% of TLA b. 25% of TLA d. 10% of TLA Situation 23 - The following questions relate to Design Problem No. 1 - Logistics Center Expansion and about SITE PLANNING. 111. Calendar days do not include what? a. weekends c. special holidays b. non-working holidays d. NOTA 112.What term refers to the area between two structural supports? a. span c. division b. tributary d. bay 113.Which of the following pairs of bearings are parallel? a. N45°%14?E and N134°46?W c. N85°30°E and N&6*0O*W b. $45°14°W and N14°21°E d. $65°56"N and S65°34°E 114.What is the typical depth specified for clearing and grubbing? a. 300mm cc. 5@@nm b. 45@nm d. 18mm 115.What do you call the movement of materials in construction? a. transfer c. carriage b. hauling d. lead Situation 24 - The following questions relate to Design Problem No. 2 - Three-Story Conmercial Space and about ARCHITECTURAL DESIGN. 116.Which of the following does not improve the water efficiency of a building? a. rainwater harvesting c. water-efficient fixtures b. overhead water storage d. recycling water from STP 117.Which of the following NBCP referral codes is not required to be applied for this project? a. Fire code c. 6B Code b. BP 344 4. None of the above 118.What is the masonry thickness of a firewall? a. 125mm c. 100mm b. 15@mm d. 20mm Page 18 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) 119. Electrical installations shall conform to the requirements of the a. Philippine Electrical Engineering Code b. Philippine Electronics Code ¢. National Electrical Code d. Philippine Electrical Code 120.Which of the following is NOT a basis of the assessment for fees and charges Of a proposed construction? a. occupancy type c. lot area b. cost of construction d. floor area Situation 25 - The following questions relate to Design Problem No. 2 - Three-Story Commercial Space and about SITE PLANNING. 121.What do you call the process of transferring of full-grown trees by digging ‘the root and soil in circular shape? a. ball-moving c. earth-balling b. sphere transfer d. tree-transfer 122.what term refers to a natural water that results from the mixture of saltwater and freshwater? a. potable c. aquifer b. gray d. brackish 123.Which point of the site has the lowest natural elevation? a. the sidewalk c. left side b. rear of the lot d. right side 124.What is the AMBF of this project using Table VIII.1 and considering the project requirements? a. 299.2sqn c. 264 sqm b. 246.4sqn d. 16sqn 125.What is the approximate building height of the project? a. 10.00n c. 15.00m b. 12.00m d. 18.00m Situation 26 - The following questions relate to Design Problem No. 2 - Three-Story Commercial Space and about SITE PLANNING. 126.Which is not counted as part of the building height as reference for the determination of BHL? a. basement parking floors b. Floors below ground floor level c. floors below natural grade d. floors below established grade elevation 127. The unit cost of clearing and grubbing is typically in terms of what? a. area c. depth b. volume d. pieces of stumps 128.Who is responsible to formulate or develop the zoning ordinance of a city? a. HLURB c. LGU b. OPWH d. 080 Page 19 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) 129.ldho releases sanitary permit for food or non-food establishments? a. Barangay Health Center c. City Health Officer b. DOH Secretary d. 080 13@.What is the provided USA in terms of TLA percentage? a. 5% of TLA c. 10% of TLA b. 9% of TLA d. 25% of TLA Situation 27 - The following questions relate to Design Problem No. 2 - Three-Story Commercial Space and about ESTIMATES. 131.What is the approximate number of CHBs required to construct the wall enclosing the rentable space at the 3° floor if the wall height is 2.8m, using natural ventilation and window openings are at minimum? a. 1609 pcs c. 1457 pes b. 1820 pcs d. 1958 pcs 132.How many 600mm x 6@nm ceramic tiles are used for the flooring of the law office at 2" floor? a. 458 c. 385 b. 493 d. 524 133.What is the approximate volume of compacted fill required to raise the finished floor of the ground floor level 200mm above the highest adjoining sidewalk? Assume there is a 15@nm concrete slab. a. 36.5m? c. 464m? b. 46.4m? d. 58.6n* 134,What is the maximum impervious surface area allowed for the project? a. 7.4sqm +c, 35.2sqm b. 52.8sqm d. 88.2sqm 135.What should be the maximum width of the roof eaves on the rear side of the building? a. 1.00m c. 1.80n b. @.80n d. 125m Situation 28 - The following questions relate to Design Problem No. 2 - Three-Story Conmercial Space and about ARCHITECTURAL DESIGN. 136.How many office-based employees is the lawyer-businessman allowed to hire? Assume that the ceiling height of the office is 2.7m. a. 38 c. 39 b. 37 d. 40 137.What is the minimum thickness of tempered glass used for shower enclosures? a. 3.0mm 1.0mm b. 4.8mm dd. 12.@nm 138.What is the illumination requirement for general offices? a. 500 lux c. 1008 lux b. 500 lumens d. 1588 footcandles Page 20 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) 139.Which drawing refers to the structural, mechanical, electrical or other construction systems of the project? a. presentation drawings c. engineering drawings b. contract drawings d. bidding documents 140.Which’ of the following is active sustainable design strategy? a. high efficiency HVAC c. shading vegetation b. proper wind orientation d. proper building site Situation 29 - The following questions relate to Design Problem No. 2 - Three-Story Commercial Space and about ARCHITECTURAL DESIGN. 141.Where is the ideal location of the VSTR in relation to the building? a. front right corner ¢. rear right corner b. front left corner d. rear left corner 142.Which of the following is NOT included in architectural interiors? a. wall finishes c. fixtures specifications b. built-in cabinets d. fascia design 143.What is the maximum distance from any point in any building without automatic fire detection system to any fire alarm box? a. 45m ce 60m b. 30m d. 61m 144.Which of the following is not an earth tone? a. brick red c. Light blue b. brown orange d. umber 145.Who is the current secretary of DPWH (Nay 221)? a. Mark Villar ¢. Teofilo S. Pilando, Jr. b. Eduardo Afio d. Rogelio Singson Situation 30 - The following questions relate to Design Problem No. 2 - Three-Story Commercial Space and about SITE PLANNING. 146. What is the width of no-build zone on each side of a fault line? a. 1¢km c. 5.0m b. 12m d. 25m 147.Which is NOT a good characteristic of tree which can be harmful to the site? a. arboreal c. deep-rooted b. shallow-rooted d. canopy 148.Which is NOT included in site and physical planning services of an architect? a. arrangement of buildings b. arrangement of amenities ¢. subdivision planning d. comprehensive development plan 149.Which structure allows water to flow under and across a road? a. curb c. pipe b. culvert d. drainage Page 21 of 31 ARCHITECTURE LICENSURE MOCK EXAMINATION Set 2A Day 2 (Design) 158.Which type of lot should theoretically have the largest open space requirement? a. interior lot c. through lot b. inside lot d. regular lot Situation 31 - The following questions relate to Design Problem No. 2 - Three-Story Commercial Space and about ARCHITECTURAL INTERIORS. 151.Which of the following color combination expands most the interior space horizontally? a. light ceiling and walls b. dark walls and dark ceiling c. dark ceiling and light walls d. Light wainscot over dark walls and light ceiling 152.Which type of window is used on basement? a. casement c. awning b. hopper d. sliding 153.What is the typical height of wall convenience outlet from the floor? a. 300mm cc. 580mm b. 45¢nn dd. 68@nm 154.According to BP 344, what is the preferred height of doorknob? a. 900mm c. 1200mm b. 100@nm d. 820mm 155.Which countertop material is artificial? a. granite c. quartz b. marble d. travertine Situation 32 - The following questions relate to Design Problem No. 2 - Three-Story Commercial Space and about ARCHITECTURAL INTERIORS. 156.798 series, 868 series and 900 series are framing profiles for what? a. cabinets c. sliding windows b. awning windows d. casement windows 157.Which type of windows is the least ideal for natural ventilation? a. sliding windows c. jalousie windows b. casement windows d. all of the above 158.Which gas fills the gap between panes in IGUs? a. argon ¢. carbon monoxide b. helium d. oxygen 159. According to Fire Code, which does not count as an interior finish? a. ceiling finish c. wall finish b. partition finish d. floor finish 168.Which type of window glazing has a thin, translucent metallic coating reflecting a portion of the light and radiant heat that strike it? a. low-emissivity glass c. insulating glass b. reflective glass d. obscure glass Page 22 of 31

You might also like