From: Cherie Alaedini

Sent: Tuesday, September 6, 2022 11:09 AM


To: Zhang Jing
Cc: Brandon Zhang
Subject: FW: Bulletin-40-2c-FRP-reinforcement-in-RC-structures.pdf [Filed 06 Sep
2022 11:09]

Categories: Filed by Mail Manager

Hi Zhang,,

FYI –some good guidance on FRP from ACI.


File:
ACI 440.2R-17 Guide for the Design and Construction of Externally Bonded FRP Systems for
Strengthening Concrete Structures.pdf

Location:
\\global.arup.com\australasia\SYD\Projects\254000\254810-00 Chatswood ChaseL2
Raised\Work\Internal\Design\Struct\Calcs\60_2022 Scheme\L3 landscape terrace\Reference\FRP\

For flexural strengthening (chapter 10) strength increases of up to 40% are reasonable. It’s governed by
strain compatibility between debonding or rupture failure of the FRP vs concrete crushing and yielding of
reo/ PT.

For axial strengthening (chapter 12) it seems straight forward to calculate and appears 30% is doable for
circular columns. For rectangular it is a simple equivalent confined area calc based on the aspect ratio
with a limit on h/b to 1.5
We can even reinforce the existing moment frame columns to enforce a plastic hinge failure mode if we
want (see seismic strengthening chapter 13):
Regards,
Cherie