Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

6000PLUS/BASE & 3000PLUS/BASE

Fire Detection - Addressable


Low Profile Common Mounting Base

• Quick and simple to Install

• Aesthetic, low profile design

• Compatible with Protec 3000PLUS or


6000PLUS series detectors

• Screen / earth terminal available


(6000PLUS/BASE version)

• Robust terminal wiring

• Continuity switch on 6000PLUS/BASE


version

• Continuity diode included on 3000PLUS/


BASE to comply with BS5839

• Approved to EN54 when used with


Protec detectors
NOTE: Image shows 6000PLUS Base

The Protec 3000PLUS and 6000PLUS Order Codes


standard base are designed for use with 3000PLUS/BASE
either the Protec 3000PLUS or 6000PLUS 6000PLUS/BASE
series fire detection devices. It allows
the detectors to be mounted directly to
any flat surface, or BESA box. Provision
is also made for surface mount trunking
entry via side
breakouts.

The 6000PLUS/BASE has an in-built earth


connection to allow easy termination of
cable screens and permit earth continuity
on broken segments of cable.

The base features robust wiring terminals


with captive clamping washers to ensure
secure wiring termination. Terminals are
provided inside the moulding for loop /
zone connections and the termination of
cable screening. Provision is also made
for the connection of an optional remote
LED if required.

Loop or zone continuity is maintained by


a switch on the 6000PLUS/BASE or a low
forward Voltage diode on the 3000PLUS/
BASE.

A D D R ESS IN G S A F E T Y SYST E M S W I T H I N T E L L I G E N CE
Fire Detection - Addressable

Technical Specification

Dimensions Technical Specification


18,37
Environment -10 to 50ºC, 95% R.H
dia
0
12,37 (non-condensing or icing)
98,6

Ingress Protection IP32

Weight 56g

Voltage Range 30V maximum

Mounting Surface or BESA box


98,60

Material White Polycarbonate V0 rated

Application Indoor Installation

EMC CE marked (EEC89/336)

Product Approval Bases are included in the detector


head approval

3000PLUS Detector Wiring Details 6000PLUS Detector Wiring Details

ZONE
ZONE++ININ(X)
(X) ZONE
ZONE++OUT
OUT(Y)
(Y) LOOP
LOOP++ININ(X)
(X) LOOP
LOOP++OUT
OUT(Y)
(Y)

DIODE
DIODETO
TOCOMPLY
COMPLYWITH
WITH
BS5839
BS5839PART
PART11 OPTIONAL
OPTIONAL OPTIONAL
OPTIONAL
REMOTE
REMOTE REMOTE
REMOTE
LED
LED LED
LED
SCREEN
SCREENCONTINUITY
CONTINUITY INDICATOR
INDICATOR SCREEN
SCREENCONTINUITY
CONTINUITY INDICATOR
INDICATOR
TERMINAL
TERMINAL (Y(YTO
TOZ)Z) TERMINAL
TERMINAL (Y(YTO
TOZ)Z)

ZONE
ZONE- -ININ(W)
(W) ZONE
ZONE- -OUT
OUT(W)
(W) LOOP
LOOP- -ININ(W)
(W) LOOP
LOOP- -OUT
OUT(W)
(W)

Company Policy is one of continuous improvement, we reserve the right to change specification without prior notice
Protec Fire Detection Plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT © 2015 - 2019 Protec Fire Detection plc

Tel: 01282 717171 Fax: 01282 717273 Web: www.protec.co.uk Email: sales@protec.co.uk
MED2042 Issue 2

You might also like