Revised Portacabin

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

LEGEND

38400
4058 4000 3943 3943 4115 3888 4112 3843 4100 2400 D/B

4000 4000 8000 8000 4946 9454


1200 2532 1169 1166 1166 1166 1166 1172 1200 1200
W1 W1 W1 W1 V1 V1 V1 V1 V1 V1 V1
950x950 mm 950x950 mm 950x950 mm 950x950 mm
Split A/C 1.5 Ton Split A/C 1.5 Ton Split A/C 1.5 Ton Split A/C 1.5 Ton Split A/C 1.5 Ton Split A/C 1.5 Ton Split A/C 1.5 Ton

1800
1800

710x2000mm 710x2000mm 710x2000mm 710x2000mm 710x2000mm 710x2000mm 710x2000mm 710x2000mm

4000
710x2000mm W.D-4 W.D-4 W.D-4 W.D-4 W.D-4 W.D-4 W.D-4 W.D-4
W.D-4

V1

1142
Toilet & Shower Area Ladies Toilets
Liaison Engineer Mech. or Elec. Eng. Conference Room Site Inspector & Material Ass. Resident Eng.
950x950 mm

W.D-4
710x2000mm

Inspector URINALS
W1

1059
600 600 600

710x2000mm
W.D-4
W.D-3 W.D-3 W.D-3 W.D-3 W.D-3 W.D-3 W.D-3 W.D-4
850x2000mm 850x2000mm 850x2000mm 850x2000mm 850x2000mm 850x2000mm 850x2000mm 710x2000mm
300 300 1000 1000 300 300

10000 mm
980x2100mm

980x2100mm

2000
Corridor Corridor Corridor
1200

1200
S.D-1

S.D-1
1500x2000mm
850x2000mm 850x2000mm 850x2000mm 850x2000mm 850x2000mm 850x2000mm
W.D-3 W.D-3 W.D-3 Opening W.D-3 W.D-3 W.D-3

²
950x950 mm

Resident Engineer Typist / Clerk / Filing Reception & Waiting Area


W1

Safety Officer Office Land Surveyor & Q.S Team. PANTRY & DINING AREA
Draftsman

Split A/C 2 Ton

4000
²

W.D-4
710x2000mm
1800
V1

W.D-4

Split A/C 2 Ton


950x950 mm
W1
Split A/C 1.5 Ton
950x950 mm
W1
950x950 mm
W1
Split A/C 1.5 Ton
950x950 mm
W1
1500x2100mm
A.D-2
950x950 mm
W1
Split A/C 1.5 Ton
950x950 mm
W1
Split A/C 1.5 Ton
950x950 mm
W1
Split A/C 2 Ton

V1 Note

1000
1200

300 300
1800

6000 6000 4000 6000 8000 4000 4400

G.I Stud Roof Purling


90x45x.6mm Set at as per Design

Skid Beam
M.S 120 CLIENT:
26 Gauge G.I Single Skin Profile
35mm Diameter Sheet RAL-9002 G.I Fascia
Cabin Lifting 12mm
:N
GIDALC LN
AREN
TI 50mm thick Glass Wool
M.S Plate D
R
O
A
BU
MSPYG .K
HTm5m.21 Insulation Density 12kg/m3
:N
GID
ALC LN
ARETXE with Aluminum Foil Paper
Ceiling Purling 90x45x0.9mm Set
Lifting Aye Isometric View DR
O
A
BM N
TEC .KHTm6m
G.I Stud Roof Purling at 600mm Spacing C/C.
90x45x.6mm Set at as per Design

:N
GM
ARIF LWLA
KCARTU
DTS IG .K
HTm
5m
8.0X01X54X09 Set at 600mm Spacing
@m 0m
06 YLLACITREV &m
0m
021 M.S Angle Trusses Steel Strength G550
YLLAO N
TZIOH
R

Out Door
Angle 50x50 mm
12mm M.S.I Plate Lifting
M.S Angle Trusses Eyes each Skid 4 No's
O
N
: ITAU
LN
SI
WO
LSSALG
m0m
5 Angle 25x25 mm M.S Angle Joists
m
/gk21( YTIN
SEDO
NITAULN
SI )³
G.I Stud Ceiling Purling G.L
90x45x.6mm Set at as per Design
Concrete Foundation Pedestal
Regular Gypsum Board Size:
12.5x1200x2400mm
Wall Isometric View
Truss Isometric View Typical Details Section
CONTRACTOR:
Ras Al Khaimah
Emirates Tel: +971-7-2336738
Fax: +971-7-2336739

Portacabin P.O. Box: 33865


Email: sales@portacabinsuae.com
Web: portacabinsuae.com

Ahmad
N.T.S 10-05-2022

Dubai Delivery FOR APPROVAL

EPC-Q-1604387 1 OF 1