Professional Documents
Culture Documents
Retrieve 5418
Retrieve 5418
E1105
multi-function weight indicator
Description
General
This specification describes the
E1105 advanced multi-function
weight indicator, capable of
stand-alone operation, or of
integration into a larger system
via serial, FieldBus and Ethernet
interfaces.
It is a microprocessor-based
industrial weighing system with up
to 100,000 displayed increments
for analysing, displaying, storing
and transmitting gross and net
weight information.
1
E1105 Avery Weigh-Tronix Technical Specification
2
Avery Weigh-Tronix Technical Specification E1105
Dynamic Filter
Calibration Applied after the FIR filter. Balance/Zero
Set the filter window size in
Full digital multi-point (ten point) divisions (0 - 99). A high value Setting
calibration. will have a large damping effect Keyboard push button.
on the weight display.
Theoretical calibration possible if This significantly slows the scale Operation
parameters known. response to a legitimate change Ignore or recall limit exceeded.
in weight.
Provides over load report. Size of Balance Range
Harmonizer™ Digital Filter Normally 2%, up to 100%.
Increment Multiplier Three programmable parameters:
1, 2, 5,10, 20, 50, 100, 200, 500. Zero Indication
Samples to Average - sets Within 2% of maximum capacity.
AVR number of A-D conversions which
Three stage. will be averaged to give a weight Under Range Indication
reading. Displays ‘_ _ _ _ _ _’.
Gravity Compensation
Set gravity for calibration and IIR Filter - sets how much Zero Tracking
installation site. damping the Harmonizer™ Configurable
applies to the weight reading.
Analogue to Digital Typically between 1 (low) - 8 Motion Detection
(higher). Configurable.
Convertor
Display Update Rate
Threshold Level - sets the Range/Span
minimum weight change (in
1, 2, 5, 10 per second. calibration units) which the Range of Adjustment
Harmonizer™ will not attempt to 0 - 100,000 divisions.
A to D Rate filter out as noise.
120 per second.
Over Range Indication
A to D Type Displays ‘- - - - - -’.
Delta Sigma.
Tares
Filter
Three types of tares are available.
Each is 100% subtractive.
FIR & Dynamic Filtering
Seven programmable Options Note: Interlocks between the tare
types are configurable at time of
Associated Filter Attributes
commissioning.
Filter Level Display Weight Noise Noise
Response Time Sample Rate Amplitude Frequency Type A - Push-Button (Semi
(seconds) (Hz) Auto) Tare
Push-button operated, semi-
0 0.20 8.13 Lowest Highest automatic, with selectable
1 0.35 8.13 negative weight display.
Cumulative taring is possible.
2 0.53 8.13
3 0.96 8.13 Initialisation and Operation
When the item to tare on is
4 1.45 8.13
applied, press the ‘Tare’ push-
5 2.09 8.13 button.
6 2.85 8.13 Highest Lowest
Indication
‘Net’ annunciator is illuminated.
3
E1105 Avery Weigh-Tronix Technical Specification
4
Avery Weigh-Tronix Technical Specification E1105
5
E1105 Avery Weigh-Tronix Technical Specification
6
Avery Weigh-Tronix Technical Specification E1105
Weight Dimensions
3.3 kg
290
Shipping Specification
280 178
Net
3.3 kg
Gross
4.6 kg
280
Measurement 324
345 mm x 270 mm x 335 mm
7
E1105 Avery Weigh-Tronix Technical Specification
© Avery Berkel Limited 2005. All rights reserved. This publication is issued to provide outline information only which, unless agreed by Avery Berkel Limited in writing, may not be regarded as a representation relating
to the products or services concerned. Avery Berkel Limited reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service.