Transducers
Table of Contents
Model Page
AC Current Transducers 4
AC Voltage Transducers 7
AC Power Transducers 10
Watt (Active Power)
VAR (Reactive Power)
Q (Reactive Power)
VA (Apparent Power)
AC Energy Transducers 13
Watt/VAR/Q-Hour (Consumed Energy)
Frequency Transducers 18
RTD/Slidewire Transducers 19
Dimensions 27
Connection Diagrams 29
Before you can control electricity,
you have to measure it.
Whether you are a utility generating and distributing electricity, or an industrial
plant or commercial facility trying to manage and conserve it, optimization of your
processes depends heavily on accurate power measurement. Measurement
Technologies (mTech) has high quality transducers, covering virtually every
electrical variable, and virtually any I/O combination.
Our products are in daily use by hundreds of utilities, industrial plants, and
commercial customers from all over the world. We strive to meet the needs of the
market with more models and more features per model. We offer DIN cases for
high-density mounting, as well as the traditional, surface-mounting, metal
enclosures. All our units are built to the highest quality standards and perform with
exceptional accuracy and reliability.
We offer a range of models within each of the following categories: AC current;
AC voltage; watts; VAR; Q; VA; watt/VAR/Q-Hour; frequency; power factor;
RTD/slidewire; DC voltage/ground fault detection; and line post sensing. We even
have a portable system for testing transducers.
No one is better equipped to help you measure electricity.
3
AC Current Transducers
4
Available Models – RA/DRA Series
AC Current Transducers True RMS Sensing, Zero-Based Input
Recommended where harmonics are present in the system.
A/DA Series Uses new low voltage integrated circuit technology that
computes the RMS value of the input waveform, regardless
Average Sensing, Zero-Based Input of shape, from the fundamental to the 50th harmonic. Self-
An economical and accurate means of current measurement powered or externally-powered. Readings down to virtually
on systems where the waveform is a pure sine wave. Can zero can be achieved with auxiliary-powered models. 4-20
also be used for non-critical applications with distorted mA output versions must have auxiliary power.
waveforms, where high accuracy is not required. Calibrated
To Order, Specify:
to the RMS (root mean square) value of the sine wave.
Available in single or triple versions, self-powered or A. ENCLOSURE
externally powered. 4-20 mA and 1-5 V output versions must Extruded Aluminum Metal, Surface Mount RA
have auxiliary power. ABS DIN, Rail Mount DRA
To Order, Specify: B. CONFIGURATION
Single 1
A. ENCLOSURE
Extruded Aluminum Metal, Surface Mount A C. INPUT
ABS DIN, Rail Mount DA 0-5 A 0
0-1 A 1
B. CONFIGURATION
Special X
Single 1
Triple 3 D. OUTPUT
0-1 mA (0-10,000 Ohms) 0
C. INPUT
4-20 mA (0-750 Ohms) Aux Power Only 4
0-5 A 0
Special X
0-1 A 1
0-2 A 2 E. SUFFIX (If Applicable)
0-10 A 3 25 to 125% Calibration A
0-25 A ① 4 50 Hz C
Special X 400 Hz D
① Metal case models only. 120 VAC Aux Power E
230 VAC Aux Power F
D. OUTPUT
Case Ground Terminal ① G
0-1 mA (0-10,000 Ohms) 0
DC Aux Power (Please Specify) K
0-3 mA (0-3,300 Ohms) 1
Special X
0-5 mA (0-2,000 Ohms) 2 ① Metal case models only.
0-10 mA (0-1,000 Ohms) 3
4-20 mA (0-750 Ohms) ② 4 EXAMPLE: RA-1-0-4-F is the ordering code for an RMS-
0-100 mV (2,000 Ohms min.) 5 Sensing Current Transducer in a metal surface mount
0-1 V (2,000 Ohms min.) 6 case, a single version, with a 0-5 A input, a 4-20 mA
0-5 V (2,000 Ohms min.) 7 output, and 230 VAC auxiliary power.
0-10 V (2,000 Ohms min.) 8
1-5 V (2,000 Ohms min.) ② 9
Special X
SA/DSA Series
E. SUFFIX (If Applicable) Three-Phase Summation Transducers
25 to 125% Calibration A Average sensing devices calibrated to the RMS value of the
50 Hz C sine wave. Available in three phase versions only, they
400 Hz D provide an output that is the arithmetic sum of the inputs.
120 VAC Aux Power E Self-powered or externally-powered. 4-20 mA and 1-5 V
230 VAC Aux Power F output versions must have auxiliary power.
Case Ground Terminal ① G To Order, Specify:
DC Aux Power (Please Specify) K
A. ENCLOSURE
Special X
① Metal case models only.
Extruded Aluminum Metal, Surface Mount SA
② Auxiliary power supply required.
ABS DIN, Rail Mount DSA
B. CONFIGURATION
EXAMPLE: DA-3-2-4-E is the ordering code for an
Triple 3
Average-Sensing Current Transducer in a DIN rail mount
case, a triple version, with a 0-2 A input, a 4-20 mA C. INPUT
output, and 120 VAC auxiliary power. 0-5 A 0
0-1 A 1
Special X
5
D. OUTPUT 0 ± 100 mV (2,000 Ohms min.) 5
0-1 mA (0-10,000 Ohms) 0 0 ± 1 V (2,000 Ohms min.) 6
0-3 mA (0-3,300 Ohms) 1 0 ± 5 V (1,000 Ohms min.) 7
0-5 mA (0-2,000 Ohms) 2 0 ± 10 V (2,000 Ohms min.) 8
0-10 mA (0-1,000 Ohms) 3 1-5 V (1,000 Ohms min.) 9
4-20 mA (0-750 Ohms) ② 4 F. SUFFIX (If Applicable)
0-100 mV (2,000 Ohms min.) 5 25 to 125% Calibration A
0-1 V (2,000 Ohms min.) 6 50 Hz C
0-5 V (2,000 Ohms min.) 7 400 Hz D
0-10 V (2,000 Ohms min.) 8 120 VAC Aux Power E
1-5 V (2,000 Ohms min.) ② 9 230 VAC Aux Power F
Special X Case Ground Terminal ① G
E. SUFFIX (If Applicable) DC Aux Power (Please Specify) K
25 to 125% Calibration A Special X
50 Hz C ① Metal case models only.
400 Hz D
EXAMPLE: BA-1-0-1-3-E is the ordering code for a
120 VAC Aux Power E
Single-Phase Average Sensing, Bi-Directional Current
230 VAC Aux Power F
Transducer in a metal surface mount case, a single
Case Ground Terminal ① G version, with a 0-5 A input, 120 VAC potential input, a 0
DC Aux Power (Please Specify) K ± 10 mA output, and 120 VAC auxiliary power.
Special X
① Metal case models only.
② Auxiliary power supply required. TA/DTA Series
EXAMPLE: DSA-3-1-2-A is the ordering code for a Three- Single-Phase, Average Sensing, Two-Wire Loop Powered
Phase Summation Current Transducer in a DIN rail mount Average sensing, zero-based input transducers that are
case, triple-phase, with a 0-1 A input, a 0-5 mA output, calibrated to the RMS value of the sine wave. Single-phase
and 25 to 125% calibration. versions only. Two-wire loop powered. 4-20 mA output only.
To Order, Specify:
BA/DBA Series A. ENCLOSURE
Single-Phase, Average Sensing, Bi-Directional Extruded Aluminum Metal, Surface Mount TA
Average sensing, zero-based input transducers that are bi- ABS DIN, Rail Mount DTA
directional and calibrated to the RMS value of the sine wave. B. CONFIGURATION
Single-phase versions only, they must be powered from a Single 1
potential source on the power line being measured. Output is
C. INPUT
proportional to the input magnitude, with polarity set by the
0-5 A 0
direction of current flow. 4-20 mA and 1-5 V versions use 12
0-1 A 1
mA and 3 V as the zero current reference.
Special X
To Order, Specify:
D. OUTPUT
A. ENCLOSURE 4-20 mA (Load limited by loop voltage, 4
Extruded Aluminum Metal, Surface Mount BA 18-30 VDC)
ABS DIN, Rail Mount DBA
E. SUFFIX (If Applicable)
B. CONFIGURATION 50 Hz C
Single 1 400 Hz D
C. INPUT Case Ground Terminal ① G
0-5 A 0 Special X
0-1 A 1 ① Metal case models only.
Special X EXAMPLE: TA-1-1-4-G is the ordering code for a Two-
D. POTENTIAL Wire Loop Powered Single-Phase, Average Sensing
120 VAC 0 Transducer in a metal surface mount case, single-phase
Special X with a 0-1 A input, a 4-20 mA output, and a case ground
E. OUTPUT terminal.
0 ± 1 mA (0-10,000 Ohms) 0 See page 29 for connections.
0 ± 3 mA (0-3,300 Ohms) 1
0 ± 5 mA (0-2,000 Ohms) 2
0 ± 10 mA (0-1,000 Ohms) 3
4-20 mA (0-750 Ohms) 4
6
AC Voltage Transducers
7
Available Models– RV/DRV Series
AC Voltage Transducers True RMS Sensing, Zero-Based Input
Recommended where harmonics are present in the system.
V/DV Series Uses new low voltage integrated circuit technology that
computes the RMS value of the input waveform, regardless
Average Sensing, Zero-Based Input of shape, from the fundamental to the 50th harmonic. Self-
An economical and accurate means of voltage measurement powered or externally-powered. Readings down to virtually
on systems where the waveform is a pure sine wave. Can zero can be achieved with auxiliary-powered models. 4-20
also be used for non-critical applications with distorted mA version must have auxiliary power.
waveforms, where high accuracy is not required. Calibrated
To Order, Specify:
to the RMS (root mean square) value of the sine wave.
Available in single or triple versions, self-powered or A. ENCLOSURE
externally powered. 4-20 mA and 1-5 V output versions must Extruded Aluminum Metal, Surface Mount RV
have auxiliary power. ABS DIN, Rail Mount DRV
To Order, Specify: B. CONFIGURATION
A. ENCLOSURE Single 1
Extruded Aluminum Metal, Surface Mount V C. INPUT
ABS DIN, Rail Mount DV 0-150 V 0
B. CONFIGURATION Special X
Single 1 D. OUTPUT
Triple 3 0-1 mA (0-10,000 Ohms) 0
4-20 mA (0-750 Ohms) Aux. Power Only 4
C. INPUT
Special X
0-150 V 0
0-90 V 1 E. SUFFIX (If Applicable)
0-300 V 2 25 to 125% Calibration A
0-600 V 3 50 Hz C
Special X 400 Hz D
120 VAC Aux Power E
D. OUTPUT
230 VAC Aux Power F
0-1 mA (0-10,000 Ohms) 0
Case Ground Terminal ① G
0-3 mA (0-3,000 Ohms) 1
DC Aux Power (Please Specify) K
0-5 mA (0-2,000 Ohms) 2
Special X
0-10 mA (0-1,000 Ohms) 3 ① Metal case models only.
4-20 mA (0-750 Ohms) ② 4
EXAMPLE: RV-1-0-4-F is the ordering code for an RMS-
0-100 mV (2,000 Ohms min.) 5
Sensing Voltage Transducer in a metal surface mount
0-1 V (2,000 Ohms min.) 6
case, single-phase, with a 0-150 V input, a 4-20 mA
0-5 V (2,000 Ohms min.) 7
output, and 230 VAC auxiliary power.
0-10 V (2,000 Ohms min.) 8
1-5 V (2,000 Ohms min.) ② 9
Special X VX/DVX Series
E. SUFFIX (If Applicable) Single-Phase, Average Sensing, Suppressed
25 to 125% Calibration A Zero-Based Input
50 Hz C Average sensing devices calibrated to the RMS value of the
400 Hz D sine wave. Available in single-phase versions only. Self-
120 VAC Aux Power E powered or externally-powered. 4-20 mA and 1-5 V output
230 VAC Aux Power F versions must have auxiliary power.
Case Ground Terminal ① G
DC Aux Power (Please Specify) K To Order, Specify:
Special X A. ENCLOSURE
① Metal case models only. Extruded Aluminum Metal, Surface Mount VX
② Auxiliary power supply required. ABS DIN, Rail Mount DVX
EXAMPLE: DV-3-2-4-E is the ordering code for an B. CONFIGURATION
Average-Sensing Voltage Transducer in a DIN rail mount Single 1
case, a triple version, with a 0-300 V input, a 4-20 mA C. INPUT
output, and 120 VAC auxiliary power. 90-150 V 4
100-140 V 5
110-130 V 6
180-300 V 7
200-280 V 8
220-260 V 9
Special X
8
D. OUTPUT E. SUFFIX (If Applicable)
0-1 mA (0-10,000 Ohms) 0 25 to 125% Calibration A
0-3 mA (0-3,300 Ohms) 1 50 Hz C
0-5 mA (0-2,000 Ohms) 2 400 Hz D
0-10 mA (0-1,000 Ohms) 3 120 VAC Aux Power E
4-20 mA (0-750 Ohms) ② 4 230 VAC Aux Power F
0-100 mV (2,000 Ohms min.) 5 Case Ground Terminal ① G
0-1 V (2,000 Ohms min.) 6 DC Aux Power (Please Specify) K
0-5 V (2,000 Ohms min.) 7 Special X
0-10 V (2,000 Ohms min.) 8 ① Metal case models only.
1-5 V (2,000 Ohms min.) ② 9 ② Auxiliary power supply required.
E. SUFFIX (If Applicable) EXAMPLE: RVX-1-9-0-C is the ordering code for a Single-
25 to 125% Calibration A Phase, True RMS Sensing, Suppressed Zero-Based Input,
50 Hz C Voltage Transducer in a metal surface mount case,
400 Hz D single-phase, with a 220-260 V input, a 0-1 mA output,
120 VAC Aux Power E and 50 Hz.
230 VAC Aux Power F
Case Ground Terminal ① G
DC Aux Power (Please Specify) K TV/DTV Series
Special X Single-Phase, Average Sensing, Two-Wire Loop Powered
① Metal case models only.
Average sensing, zero-based input transducers that are
② Auxiliary power supply required.
calibrated to the RMS value of the sine wave. Single-phase
EXAMPLE: DVX-1-4-2-A is the ordering code for a Single- versions only. Two-wire loop powered. 4-20 mA output only.
Phase, Average Sensing Voltage Transducer in a DIN rail To Order, Specify:
mount case, single-phase, with a 90-150 V input, a 0-5
A. ENCLOSURE
mA output, and 25 to 125% calibration.
Extruded Aluminum Metal, Surface Mount TV
ABS DIN, Rail Mount DTV
RVX/DRVX Series B. CONFIGURATION
Single-Phase, True RMS Sensing, Suppressed Single 1
Zero-Based Input C. INPUT
RMS sensing, suppressed zero-based input devices. 0-150 V 0
Available in single-phase versions only. Self-powered or Special X
externally-powered. 4-20 mA version must have auxiliary
D. OUTPUT
power.
4-20 mA (Load limited by loop voltage, 4
To Order, Specify: 18-30 VDC)
A. ENCLOSURE E. SUFFIX (If Applicable)
Extruded Aluminum Metal, Surface Mount RVX 50 Hz C
ABS DIN, Rail Mount DRVX 400 Hz D
B. CONFIGURATION Case Ground Terminal ① G
Single 1 Special X
① Metal case models only.
C. INPUT
90-150 V 4 EXAMPLE: TV-1-0-4-G is the ordering code for a Two-
100-140 V 5 Wire Loop Powered Single-Phase, Average Sensing
110-130 V 6 Transducer in a metal surface mount case, single-phase,
180-300 V 7 with a 0-150 V input, a 4-20 mA output, and a case
200-280 V 8 ground terminal.
220-260 V 9 See page 30 for connections.
Special X
D. OUTPUT
0-1 mA (0-10,000 Ohms) 0
4-20 mA (0-750 Ohms) ② 4
Special X
9
AC Power Transducers
Watts • VAR • Q • VA • WR • WQ
Watts: A measure of power or work being done. In an AC
circuit, current multiplied by voltage multiplied by the cosine
of the phase angle between current and voltage. Differing
loads cause current to lag or lead voltage by some angle in
degrees, which causes the power consumed (watts) to be
less than the product of the voltage times current.
VAR: Current and voltage that does no work. A Volt-Ampere
Reactance is essentially the opposite of a watt.
VAR is the product of voltage multiplied by
current in opposite quadrants. They increase as
the phase angle increases and can be either
leading (to the high side of the center zero based
output) or lagging (to the low side of zero).
Q: A measure of reactive power. Permits
calculation of VAR-hours to be recorded with one
counter in a positive direction between 0.866
leading and zero lagging, which is within the
typical power factor range of electrical equipment.
VA: Voltage times current. Also known as
“apparent power.”
Standard Features:
• 0.2% of reading accuracy
• <0.005%/°C temperature coefficient
Long Term Drift: <0.2%/year non-cumulative
• Low burden
Temperature Range
• Transient protected Operating: -20°C to +70°C
Storage: -40°C to +75°C
• Voltage, current, and process outputs
Temperature Coefficient: ≤0.005%/°C
• Electronic multipliers — over 200 real time Operating Humidity: 0-95% non-condensing
multiplications of Volts times Amps per Output Ripple Peak: ≤0.5% peak
Power Factor Range: Watt or VAR, any; Q, 0.866 lead to
cycle for accurate conversions of even the 0 lag
most distorted waveforms Operating Frequency: Nominal ±10% in accordance with
IEC 688
• Exceptional long-term stability Standard Calibration: Watt/Q is uni-directional, VAR/VA is
• 1, 1-1/2, 2, 2-1/2, and 3 element versions bi-directional, unless otherwise specified
Dielectric Test: 2,000 Vrms for 1 minute; 2,400 Vrms
• Self-powered or externally powered for 1 second
• ABS DIN rail or metal surface mount cases Transient/Surge Test: ANSI C37.90a (IEEE 472) BEAMA 219
• Isolated outputs on combined transducers Response Time: ≤200 msec to 90%, ≤400 msec to 99%
Calibration: Full scale, ±10% standard; Zero, ±2% standard
UL Approved Models: W10000, W10004, W15000,
Specifications W20000, W20004, W25000, W25004, W30000, W30004,
Accuracy (@ 25°C ±2°C) DW10000, DW10004, DW15000, DW15004, DW20000,
Watt: 0.19% of reading ±0.01% of full scale DW20004, DW25000, DW25004, DW30000, DW30004,
CosQ R10000, R10004, R15000, R15004, R20000, R20004,
VAR: 0.19% of reading ±0.01% of full scale R25000, R25004, R30000, R30004, DR10000, DR10004,
SinQ DR15000, DR15004, DR20000, DR20004, DR25000,
Q: 0.19% of reading ±0.01% of full scale DR24004, DR30000, DR30004
Cos(Q-60°)
VA: 0.19% of reading ±0.01% of full scale
10
Potential Table
POTENTIAL RANGE WITH POTENTIAL RANGE WITH MAXIMUM BURDEN POTENTIAL OVERLOAD
OPTION NOMINAL INPUT
ACCURACY (SELF-POWERED) ACCURACY (EXTERNAL-POWERED) AT NOMINAL INPUT CONTINUOUS
0 100 - 120 V 85 - 150 V 10 - 150 V 0.1 VA * 180 V
1 63 - 69 V 50 - 90 V 10 - 90 V 0.1 VA * 100 V
2 208 - 240 V 170 - 300 V 20 - 300 V 0.1 VA * 350 V
3 460 - 480 V 325 - 575 V 30 - 575 V 0.1 VA * 700 V
4 575 - 600 V 425 - 750 V 40 - 750 V 0.1 VA* 900 V
5 265 - 277 V 170 - 300 V 20 - 300 V 0.1 VA* 350 V
6 333 - 347 V 325 - 575 V 30 - 575 V 0.1 VA* 700 V
Current Table
OVER-RANGE MAXIMUM OVERLOAD OVERLOAD OVERLOAD
OPTION INPUT
WITH ACCURACY BURDEN CONTINUOUS 10 SEC/HOUR 1 SEC/HOUR
0 0-5A 10 A 0.5 VA 15 A 30 A 200 A
1 0-1A 2A 0.5 VA 3A 6A 100 A
2 0-2A 4A 0.5 VA 6A 12 A 150 A
3 0 - 10 A 20 A 0.5 VA 30 A 50 A 300 A
Output Table
OPTION RANGE FULL SCALE OUTPUT LOADING COMPLIANCE OR MAXIMUM CURRENT
0 0 ± 1 mA 0 - 10,000 Ohms ± 11 V
1 0 ± 3 mA 0 - 3,300 Ohms ± 11 V
2 0 ± 5 mA 0 - 2,000 Ohms ± 11 V
3 0 ± 10 mA 0 - 1,000 Ohms ± 11 V
4 4 - 20 mA 0 - 750 Ohms 15 V
5 0 ± 100 mV ∞
20 Ohms - 5 mA
6 0±1V 200 Ohms - ∞ 5 mA
7 0±5V 1,000 Ohms - ∞ 5 mA
8 0 ± 10 V 2,000 Ohms - ∞ 5 mA
9 1-5V 1,000 Ohms - ∞ 5 mA
Application Table
APPLICATION NUMBER MODEL NUMBER SERIES RESTRICTIONS
AND OF
CONNECTION ELEMENTS WATT VAR Q VA VOLTAGE CURRENT
1 PHASE, 2 WIRE 1 DW10XXX DR10XXX DQ10XXX DVA10XXX NONE NONE
1 PHASE, 3 WIRE 1 DW10XXX DR10XXX DQ10XXX DVA10XXX NONE NONE
1 PHASE, 3 WIRE 11⁄2 DW15XXX DR15XXX DQ15XXX DVA15XXX NONE NONE
3 PHASE, 3 WIRE 1 ⁄2
1
DW15XXX DR15XXX DQ15XXX DVA15XXX BALANCED NONE
3 PHASE, 3 WIRE 2 DW20XXX DR20XXX DQ20XXX DVA20XXX NONE NONE
3 PHASE, 3 WIRE 21⁄2 DW25XXX DR25XXX DQ25XXX DVA25XXX NONE NONE
3 PHASE, 4 WIRE 21⁄2 DW25XXX DR25XXX DQ25XXX DVA25XXX BALANCED NONE
3 PHASE, 4 WIRE 3 DW30XXX DR30XXX DQ30XXX DVA30XXX NONE NONE
11
Available Models – G. SUFFIX (If Applicable)
25 - 125% Calibration Adjustment A
AC Power Transducers 50 Hz C
400 Hz D
To Order, Specify: External Power, 85 - 150 VAC E
A. ENCLOSURE External Power, 170 - 300 VAC F
Extruded Aluminum Metal, Surface Mount (no prefix) 4 - 20 mA Two-Wire Loop Output T
ABS DIN, Rail Mount D DC Aux Power (Please Specify) K
Case Ground Terminal ① G
B. MODEL
Special Calibration or Option X
Watt W
VAR R ① Metal case models only.
Q Q
VA VA SPECIAL CALIBRATION INSTRUCTIONS
Watt/VAR* WR Please specify: 1. CT Ratio; 2. PT Ratio; 3. Desired Full
Watt/Q WQ scale Calibration in kW, kVAR, kQ, or kVA.
C. CONFIGURATION EXAMPLE: DW-25-0-0-3-E-X is the ordering code for a
1 Element 10 Watt Transducer in a DIN rail mount case, 2-1/2 element,
1-1/2 Element 15 100-120 V input voltage, 0-5 A input current, 0 ± 10 mA
2 Element 20 output, 85-150 VAC external power, special calibration.
2-1/2 Element 25 See pages 31 - 33 for connections.
3 Element 30
D. INPUT NOMINAL VOLTAGE
(Reference Potential Table)
100 - 120 V 0
63 - 69 V 1
208 - 240 V 2
460 - 480 V 3
575 - 600 V 4
265 - 277 V 5
333 - 347 V 6
Special X
E. INPUT CURRENT (Reference Current Table)
0-5A 0
0-1A 1
0-2A 2
0 - 10 A 3
0 - 25 A 4
Special X
F. OUTPUT (Reference Output Table)
0 ± 1 mA (0 - 10,000 Ohms) 0
0 ± 3 mA (0 - 3,300 Ohms) 1
0 ± 5 mA (0 - 2,000 Ohms) 2
0 ± 10 mA (0 - 1,000 Ohms) 3
4 - 20 mA (0 - 750 Ohms) 4
0 ± 100 mV (2,000 Ohms min.) 5
0 ± 1 V (2,000 Ohms min.) 6
0 ± 5 V (1,000 Ohms min) 7
0 ± 10 V (2,000 Ohms min) 8
1 - 5 V (1,000 Ohms min) 9
Special X
Note: 4 - 20 mA units are uni-directional.
If a bi-directional unit is required, use
output designator X and state.
12
AC Energy Transducers
Watt/Watt-hour • VAR/VAR-hour
Q/Q-hour • Combined Watt/Watt-
hour and VAR/VAR-hour or
Watt/Watt-hour and Q/Q-hour
Uni-directional or Bi-directional
13
Potential Table
POTENTIAL RANGE WITH POTENTIAL RANGE WITH MAXIMUM POTENTIAL
OPTION NOMINAL INPUT
ACCURACY (SELF-POWERED) ACCURACY (EXTERNAL-POWERED) BURDEN OVERLOAD
0 120 V 85 - 150 V 0 - 150 V 0.02 VA 180 V
1 69 V 50 - 90 V 0 - 90 V 0.02 VA 100 V
Note: Self-powered units have a potential burden of less than 4.5 VA on terminals 3 and 4.
Current Table
OVER-RANGE MAXIMUM OVERLOAD OVERLOAD OVERLOAD
OPTION INPUT
WITH ACCURACY BURDEN CONTINUOUS 10 SEC/HOUR 1 SEC/HOUR
0 0-5A 10 A 0.5 VA 15 A 30 A 250 A
3 0 - 10 A 20 A 0.5 VA 30 A 50 A 300 A
4 0 - 25 A 35 A 0.5 VA 35 A 75 A 300 A
Output Table
OPTION RANGE FULL SCALE OUTPUT LOADING COMPLIANCE OR MAXIMUM CURRENT
0 0 ± 1 mA 0 - 10,000 Ohms ± 11 V
1 0 ± 3 mA 0 - 3,300 Ohms ± 11 V
2 0 ± 5 mA 0 - 2,000 Ohms ± 11 V
3 0 ± 10 mA 0 - 1,000 Ohms ± 11 V
4 4 - 20 mA 0 - 750 Ohms 15 V
5 0 ± 100 mV ∞
20 Ohms - 5 mA
6 0±1V 200 Ohms - ∞ 5 mA
7 0±5V 1,000 Ohms - ∞ 5 mA
8 0 ± 10 V 2,000 Ohms - ∞ 5 mA
9 1-5V 1,000 Ohms - ∞ 5 mA
Note: 11⁄2 Element Transducers are calibrated as 2 element. 21⁄2 Element Transducers are calibrated as 3 element.
Application Table
CONNECTION MODEL NUMBER RESTRICTIONS
WATT VAR Q WATT/VAR WATT/Q VOLTAGE LOAD
14
Available Models – G. SUFFIX (If Applicable)
25 - 125% Calibration Adjustment A
AC Energy Transducers 50 Hz C
400 Hz D
To Order, Specify: External Power, 120 VAC E
A. MODEL External Power, 230 VAC F
Watt/Watt-hour WH Case ground terminal G
VAR/VAR-hour RH DC Aux Power (Please Specify) K
Q/Q-hour QH Special X
Watt/Watt-hour, VAR/VAR-hour WRH PULSE CALIBRATION INSTRUCTIONS
Watt/Watt-hour, Q-Q-hour WQH Full scale counts per hour must be stated.
B. CONFIGURATION CPH = CT Ratio x PT Ratio x FS Calibrating Power of Transducer
1 Element 10 Desired Primary Watt-hours Per Pulse
1-1/2 Element 15 EXAMPLE: WH-15-3-1-2-1-C is the ordering code for a
2 Element 20 Watt/Watt-hour Transducer in a metal surface mount
2-1/2 Element 25 case, 1-1/2 element, 460 V input voltage, 0-1 A input
3 Element 30 current, 0 ± 5 mA, Hg wetted output relay, uni-directional,
C. INPUT NOMINAL VOLTAGE 50 Hz power.
(Reference Potential Table) See pages 34 - 35 for connections.
120 V 0
69 V 1
230 V 2
460 V 3
600 V 4
Special X
D. INPUT NOMINAL CURRENT
(Reference Current Table)
0-5A 0
0-1A 1
0-2A 2
0 - 10 A 3
0 - 25 A 4
Special X
E. OUTPUT
(Reference Output Table)
0 ± 1 mA (0-10,000 Ohms) 0
0 ± 3 mA (0-3,300 Ohms) 1
0 ± 5 mA (0-2,000 Ohms) 2
0 ± 10 mA (0-1,000 Ohms) 3
4 - 20 mA (0-750 Ohms) ① 4
0 ± 100 mV (2,000 Ohms min.) 5
0 ± 1 V (2,000 Ohms min.) 6
0 ± 5 V (2,000 Ohms min.) 7
0 ± 10 V (2,000 Ohms min.) 8
1 - 5 V (2,000 Ohms min.) ① 9
Special X
NOTE: 4-20 mA units are uni-directional.
If a bi-directional unit is required, use output
designator X and state.
① Auxiliary power supply required.
F. PULSE OUTPUT
Solid-state, uni-directional 0
Hg wetted relay, uni-directional 1
Solid-state, bi-directional, WH, RH 2
Hg wetted relay, bi-directional, WH, RH 3
Solid-state, bi-directional, WRH 4
Hg wetted relay, bi-directional, WRH 5
Special X
15
Power Factor and
Phase Angle Transducers
mTech offers these devices for producing a DC output
linearly proportional to the phase angle difference
between two inputs. Outputs are bipolar, so leading and
lagging signals can be differentiated. The transducers are
single-phase; however, they can be used on three phase,
four-wire systems with balanced loads.
Phase Angle: These transducers compare two voltage
inputs.
Power Factor: For comparing one voltage and one
current input*.
*Conversion is required for linear phase
angle information.
A table is available on request.
16
Available Models – Power Factor/ G. SUFFIX (If Applicable)
25 - 125% Calibration Adjustment A
Phase Angle Transducers 50 Hz C
400 Hz D
To Order, Specify: External Power, 120 VAC E
A. ENCLOSURE External Power, 230 VAC F
Extruded Aluminum Metal, Surface Mount (no prefix) Case ground terminal ① G
ABS DIN, Rail Mount D DC Aux Power (Please Specify) K
L-L Calibration, Delta Systems L
B. MODEL
4 - 20 mA two-wire loop output T
Phase Angle PA
Special X
Power Factor PF ① Metal case models only.
C. NOMINAL INPUT VOLTAGE (± 25%)
EXAMPLE: DPA-1-2-0-2-3-D is the ordering code for a
120 V 0
Phase Angle Transducer in a DIN rail mount case, 69 VAC
69 V 1
input voltage, 240 V, ± 90°, 0 ± 50 mV 10 Ohms min.
240 V 2
output, 400 Hz power.
460 V 3
600 V 4 See page 36 for connections.
Special X
D. PA - NOMINAL INPUT VOLTAGE
120 V 0
69 V 1
240 V 2
460 V 3
600 V 4
Special X
PF - INPUT CURRENT
1-5A 0
0.2 - 1 A 1
0.4 - 2 A 2
2 - 10 A 3
5 - 25 A 4
Special X
E. Power Factor Phase Angle
±1 ± 90° 0
± .7 ± 60° 1
± .5 ± 45° 2
± .3 ± 30° 3
± .2 ± 15° 4
Special Special X
F. OUTPUT
0 - 1 mA (0 - 10,000 Ohms) 0
0 ± 1 mA (0 - 10,000 Ohms) 1
0 ± 0.5 mA (0 - 20,000 Ohms) 2
0 ± 50 mV (2,000 Ohms min.) 3
0 ± 100 mV (2,000 Ohms min.) 4
0±1V (2,000 Ohms min.) 5
0 ± 10 V (2,000 Ohms min.) 6
1-5V (2,000 Ohms min.) 7
4-20 mA (0-750 Ohms) 8
0 ±10 mA (0-1,000 Ohms) 9
Special X
17
Frequency Transducers
18
RTD and Slidewire Transducers
20
Line Post Sensor Transducers/Fault Alarms
Alarm Function: An alarm can be triggered if the input either Surge Withstand: ANSI C37.90a (IEEE 472)
exceeds or goes below the set point. As a result, the Response Time: 200 msec to 90%; 400 msec to 99%; alarm
transducer can monitor either overvoltage or undervoltage. If - 10 msec minimum (actual trip time depends on magnitude
used for monitoring current through the line, the transducer of fault and operating level prior to fault)
should have its alarm set for overcurrent. The neutral alarm Calibration Adjustment: Span, ±10% standard; zero, ±2%
should be set to detect either any unbalance or excess of the standard; alarm, ±25% standard
neutral current limits.
Operating Frequency: 60 Hz ±10% with accuracy unless
Alarm Contact: Users can specify either Normally Open (NO) specified otherwise by suffix to part number
or Normally Closed (NC) contacts for the alarm outputs.
Power Requirements: 8 VA maximum
These outputs are isolated from each other, the inputs, the
power supply, and the analog outputs.
21
Available Models – Line Post Sensor H. AUXILIARY POWER
120 VAC 0
Transducers/Fault Alarms 240 VAC 1
To Order, Specify: 24 Vdc 2
48 Vdc 3
A. MODEL
125 Vdc 4
Line Post Sensor Transducer (Supplied in
Special X
Extruded Aluminum Metal, Surface Mount) LP
I. ALARM CONTACT
B. INPUT TYPE
Normally Open NO
AC Current A
Normally Closed NC
AC Voltage V
If not applicable Z
C. CONFIGURATION
J. ALARM FUNCTION
4 Analog Outputs & 3 Alarms 3
Overvoltage/Overcurrent O
3 Analog Outputs & 4 Alarms 4
Undervoltage U
3 Analog Outputs & 3 Alarms 5
If not applicable Z
4 Analog Outputs Only 6
3 Analog Outputs Only 7 K. SAFETY FEATURE
4 Alarms Only 8 On Power Supply Failure, Relays
3 Alarms Only 9 Switch to ALARM A
On Power Supply Failure, Relays
D. INPUT TO TRANSDUCER
Switch to NORMAL N
5A 0
If not applicable Z
10.00 V 1
2.00 V 2 L. SUFFIX
3.00 V 3 25% - 125% Adjustment (analog output only) A
4.00 V 4 50 Hz C
5.00 V 5 Case Ground Terminal G
120 V 6 Special X
Special X EXAMPLE: LP-A-4-0-2-3-5-0-NO-O-A-G is the ordering
E. NEUTRAL % OF PHASE code for a Line Post Sensor Transducer in a metal
33% 0 surface mount case, an AC current input, a 3 analog
10% 1 outputs/4 alarms configuration, a 5 A input to transducer,
20% 2 20% neutral % of phase, 0-10 mA 0-1,500 Ohms analog
25% 3 output, 33% alarm % of full scale, 120 VAC auxiliary
50% 4 power, a Normally Open alarm contact,
75% 5 overvoltage/overcurrent alarm function, power supply
100% 6 failure relays that switch to ALARM, and a case ground
Special X terminal.
If not applicable Z See page 38 for connections.
F. ANALOG OUTPUT
0 - 1 mA 0 - 15,000 Ohms 0
0 - 3 mA 0 - 5,000 Ohms 1
0 - 5 mA 0 - 3,000 Ohms 2
0 - 10 mA 0 - 1,500 Ohms 3
4 - 20 mA 0 - 750 Ohms. 4
0 - 100 mV 20 Ohms min. 5
0-1V 200 Ohms min. 6
0-5V 1,000 Ohms min. 7
0 - 10 V 2,000 Ohms min. 8
1-5V 1,000 Ohms min. 9
Special X
G. ALARM % OF FULL SCALE
133% 0
150% 1
100% 2
75% 3
50% 4
33% 5
25% 6
Special X
22
Line Post Sensor Transducer System
23
Available Models – Line Post
Sensor Transducer System
To Order, Specify:
A. MODEL
Line Post Sensor Transducer System LPAV3
B. SENSOR INPUT CURRENT
600 A: 10 V 0
600 A: 6 V 1
Special X
C. SENSOR INPUT VOLTAGE
INPUTS RATIO
0-15 kV 0 1400: 1 V 0
0-25 kV 1 2200: 1 V 1
0-35 kV 2 3300: 1 V 2
Special X Special X
D. POWER FACTOR
±0.5 0
±0.3 1
±0.2 2
Special X
E. NEUTRAL % OF PHASE CURRENT
33% 0
10% 1
20% 2
25% 3
50% 4
75% 5
100% 6
Special X
F. OUTPUT
0-1 mA (0-10,000 Ohms) 0
0-100 mV (20 Ohms min.) 1
0-1 V (200 Ohms min.) 2
0-5 V (1,000 Ohms min.) 3
0-10 V (2,000 Ohms min.) 4
1-5 V (1,000 Ohms min.) 5
Special X
G. AUXILIARY POWER
120 VAC 0
240 VAC 1
12 Vdc 2
24 Vdc 3
48 Vdc 4
125 Vdc 5
Special X
H. SUFFIX
50 Hz C
400 Hz D
Case Ground Terminal G
Special X
EXAMPLE: LPAV3-1-22-0-4-5-3-D is the ordering code for
a Line Post Sensor Transducer System in a metal surface
mount case, 600 A: 6 V sensor input current, 0-35 kV
sensor input voltage with a 3300: 1 V ratio, ±0.5 power
factor, 50% neutral % of phase current, 1-5 V (1,000
Ohms min.) output, 24 Vdc auxiliary power, 400 Hz.
See page 38 for connections.
24
Portable Test Set for
Power Transducers
As a leading international manufacturer of power transducers, Built for ease of use and to last in the field: The TCS-914
mTech knows precisely what is required to maintain the is completely self-contained and mounted inside a rugged,
highest possible accuracies of these devices. Combined environmentally sealed, polycarbonate carrying case. The
instrumentation expertise has led to the development of a case comes with a hinged cover and storage compartment.
portable transducer test set the equivalent of seven different At only 47 cm (18.5") long by 37 cm (14.6") wide by 19 cm
instruments in one self-contained field unit. The Model (7.5") high and 12 kg (26.5 lbs), it is both compact and
TCS-914 provides field technicians with an easy and highly lightweight.
accurate, on-site means of testing all of the transducers The controls have been designed with the operator in mind.
throughout their plant or power system. All test procedures are easy to learn and perform. The front
Tests a wide range of models: The system is designed panel incorporates thumbwheel switches and percent of
for maximum versatility. It will test most mTech power setting controls for selecting current, voltage, and power
transducers (watt, VAR, voltage, current, expanded scale factor. In addition, there are facilities for full scale calibrating
voltage, and power factor models), as well as models of the of watts, VAR, volts, and amps, plus a frequency selector
same types made by other manufacturers. More specifically, switch for 50 Hz and 60 Hz.
it will measure, and indicate on a digital display, current, The solid-state TCS-914 is easily programmable, making it
voltage, watts, VAR, Q, VA, and it includes a second display extremely versatile. It generates voltage and current from a
to indicate null balance percent error and actual transducer stable internal distortion-free source and is independent of
output in engineering units. The TCS-914 also has special source frequency and distortion. All internal standards and
features such as expanded scale voltage testing and the parameters measured are true RMS and have an accuracy of
capability of monitoring a wide range of outputs. In fact, no 0.1% or higher for measuring: 0 ± 500 watts per element;
external adaptors are needed for transducers with outputs 0 ± 500 VAR per element; 0-300 volts; 0-10 amps; and field
such as 0-1 mA, 4-20 mA, 0-5 mA, 0-10 V, and others. adjustable zero and span for expanded scale volts. All digital
meters have an accuracy of 0.05% or higher for measuring:
0-300 volts; 0-19.99 amps; 0 ± 3,000 watts/VAR, true RMS;
and 0 ± 19.99 percent error.
25
Specifications OUTPUT DISPLAY:
Type: 3-1/2 digit LED
VOLTAGE OUTPUT: Metering Mode:
Range: 0-300 V Accuracy: ±(0.03% of reading + 0.02% full scale +
Accuracy: ±(0.05% of setting + 0.05% of range) 1 count)
Resolution: 1 V Null-Balance Mode:
Burden: 0-180 V: 100 mA Range: 0-±19.99%
180-300 V: 50 mA Accuracy: ± 0.1% ± 1 count
CURRENT OUTPUT: AMBIENT:
Range: 0-9.99 A Temperature: 25°C ± 15°C
Accuracy: ±(0.05% of setting + 0.05% of range) Humidity: 0-90%, non-condensing
Resolution: 0.01 A POWER-TO-OPERATE:
Compliance: 0-2.8 A: 4.0 V 100, 120 VAC +10% 60 Hz
2.8-9.99 A: 2.0 V 220, 240 VAC +10% 50 Hz
POWER FACTOR: DIMENSIONS:
Range: Full four quadrant in steps of 0.1 P.F. 47 cm (18.5") L x 37 cm (14.6") W x 19 cm (7.5") H
Accuracy: ±0.1 degrees
WEIGHT:
FREQUENCY OF OUTPUTS: 12 kg (26.5 lbs)
50 Hz: 50 Hz ±0.1%
60 Hz: 60 Hz ±0.1%
Sync: Line ±0.5%
External: External source ±0.5%
INTERNAL STANDARDS:
VOLTAGE:
Range: 0-300 V, true RMS
Accuracy: ±(0.05% of reading + 0.05% of range)
CURRENT:
Range: 0-10 A, true RMS
Accuracy: ±(0.05% of reading + 0.05% of range)
WATT:
Range: 0-3,000 W
Accuracy: ±(0.05% of reading + 0.05% of range)
CosQ
VAR:
Range: 0-3,000 VAR
Accuracy: ±(0.05% of reading + 0.05% of range)
SinQ
Q:
Range: 0-3,000 Q
Accuracy: ±(0.05% of reading + 0.05% of range)
Cos (Q-60°)
VA:
Range: 0-3,000 VA
Accuracy: ±(0.05% of reading + 0.05% of range)
STANDARDS OUTPUT:
Range: 0-4 V, automatically adjustable
Accuracy: ±0.1% full scale
OUTPUT PARAMETER DISPLAY:
Type: 4-1/2 digit LED
Accuracy: ±(0.03% of reading + 0.02% full scale
+ 2 counts)
TRANSDUCER INPUT:
Ranges: 0-1 mA, 0-10 mA, 4-20 mA, 4-12-20 mA
0-1 V, 0-10 V
Other ranges available upon request
26
Dimensions
55 105
(2.17") (4.13")
DIN-1 DIN-2
All single Current and Voltage and RTD/Slidewire models All multiple Current and Voltage and Power, Power Factor/Phase Angle,
Frequency, DC Voltage/Current models
102 (4.00")
89 (3.50")
38 104 38 104 38 104
79 (3.10")
(1.50") (4.10") (1.50") (4.10") (1.50") (4.10")
38 53
(1.50") (2.10")
160
(6.30") 142
120.7 104 (5.60") 120.7
(4.75") (4.10") (4.75") 104
(4.10")
98 79
(3.85") (3.10")
27
Dimensions
123.2
123.9 127.0 104.1 (5.85")
(4.88") (5.00") (4.10")
Size 5 Size 6
AC Energy Line Post Sensor Transducer/Fault Alarm: All
228.6 (9.00")
95.25 (3.75")
213.36 (8.40")
48.26
(1.90")
101.6 197.87
(4.00") (7.79")
Special Case:
Line Post Sensor Transducer System
28
Connections
Current Transducers
DIN Rail Mount Cases
LOOP PWR.
24 V(dc) -OUTPUT+
-
-OUTPUT+ + -OUTPUT+ -OUTPUT+ -OUTPUT+ -OUTPUT+
0-750 ohms A B C
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
CD-1 CD-2 CD-3 CD-4 CD-5
6 7 8 9 10 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 11 12 13 14 15 16 17 18 19 20 11 12 13 14 15 16 17 18 19 20
• • • • • A (R) (R)(L1)
• • B (W)(S)(L2)
• C (B) (T) (L3)
N
Notes:
1. All 4-20 mA, 1-5 V and any other live zero output transducer must have an 2. Third phase of connection drawing (CD-3) is shown as direct connect. It is
external (auxiliary) source of power. typical for any transducer where the incoming signal will not exceed the
rated intput of the transducer.
• • • • A (R) (R)(L1)
•
• • • B (W)(S)(L2)
• • C (B) (T) (L3)
• N
Notes:
1. For supply connections use No. 14 AWG or larger wires rated for at least 75°C 4. CD-3 is shown directly connected to the measured source. This is typical for
(167°F). Use copper conductors only. any configuration where CTs and PTs are not used.
2. All 4-20 mA and 1-5 V transducer outputs require an external (auxiliary) source Attention:
of power. If the transducer is mounted on a non-metallic or ungrounded surface the installer
3. Bi-directional Current transducer (CD-3) must be supplied with a source of AC must provide the means for grounding and bonding as per NEC (National Electric
power that is in phase with the measured current at unity power factor. Code) requirements.
29
Connections
Voltage Transducers
DIN Rail Mount Cases
LOOP PWR.
24 V(dc) -OUTPUT+
-
-OUTPUT+ + -OUTPUT+ -OUTPUT+ -OUTPUT+ -OUTPUT+
0-750 ohms A B C
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5
CD-1 CD-2 CD-3 CD-4
6 7 8 9 10 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 11 12 13 14 15 16 17 18 19 20 6 7 8 9 10
- + - + - + - +
AUX. PWR. AUX. PWR. AUX. PWR. AUX. PWR.
•
IF REQUIRED IF REQUIRED IF REQUIRED IF REQUIRED
• • • • • • •
• • • • • • •
A (R) (R)(L1)
B (W)(S)(L2)
C (B) (T) (L3)
N
Notes:
1. For supply connections use No. 14 AWG or larger wires rated for at least 3. Third phase of connection drawing (CD-3) is shown as direct connect. It is
75°C (167°F). Use copper conductors only. typical for any transducer where the input will not exceed the rated input of
2. All 4-20 mA, 1-5 V and other live zero outputs, transducer must have an the transducer.
external (auxiliary) source of power.
Notes: Attention:
1. For supply connections use No. 14 AWG or larger wires rated for at least If the transducer is mounted on a non-metallic or ungrounded surface the installer
75°C (167°F). Use copper conductors only. must provide the means for grounding and bonding as per NEC (National Electric
2. All 4-20 mA and 1-5 V transducer outputs require an external (auxiliary) source Code) requirements.
of power.
3. CD-3 is shown with phase A directly connected to the power line; this is
typical for any transducer where the input voltage does not exceed the
input rating.
30
Connections
•
•
•
•
•
•
•
•
LOAD
•
•
A B C
•
•
•
•
•
•
•
•
EXT. PWR. EXT. PWR.
IF REQUIRED +OUTPUT- IF REQUIRED +OUTPUT-
•
+ - + -
2 5 8 11 13 14 15 16 2 5 8 11 13 14 15 16
Va Vc Va Vb Vc Vb
Ia• Ia Ic• Ic Ia• Ia Ic• Ic
1 3 4 6 7 9 1 3 4 6 7 9
•
•
•
LOAD LOAD
LINE
R S T
LINE 2 ⁄ ELEMENT
12
LINE 2 ⁄ ELEMENT
12
A B C N 3 ELEMENT
3F, 3 W 3F, 4 W 3F, 4 W
R S T R S T
A B C A B C N
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
+ - + - + -
2 5 8 11 13 14 15 16 2 5 8 11 13 14 15 16 2 5 8 11 13 14 15 16
Va N Vc N Va N Vc N Va Vb Vc N
Ia• Ia Ic• Ia Ia• Ia Ib• Ib Ic• Ic Ia• Ia Ib• Ib Ic• Ic
1 3 4 6 7 9 1 3 4 6 7 9 1 3 4 6 7 9
•
•
•
•
•
LOAD
LOAD LOAD
•
•
•
•
•
•
•
+ - + -
2 5 8 11 13 14 15 16 2 5 8 11 13 14 15 16
Va Vb Vc N Va Vb Vc N
Ia• Ia Ib• Ib Ic• Ic Ia• Ia Ib• Ib Ic• Ic
1 3 4 6 7 9 1 3 4 6 7 9
•
•
•
AC Power Transducers
(Single Output)
Metal Surface Mount Cases
•
•
•
•
•
•
•
•
•
•
1 2 3 4 5 6 1 2 3 4 5 6
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Vc Va Vc Va
-OUTPUT+ EXT. PWR. -OUTPUT+ EXT. PWR.
V V• I I• V V• I I• IF REQUIRED IF REQUIRED
-OUTPUT+ EXT. PWR. -OUTPUT+ EXT. PWR. •
Ia Ic• Ia Ic Ia• Ic• Ia Ic
IF REQUIRED 7 8 9 10 11 12 7 8 9 10 11 12
•
•
•
LOAD LOAD LOAD LOAD
2 ELEMENT
3F, 3 W
21⁄2 ELEMENT 21⁄2 ELEMENT 3 ELEMENT
3F, 3 W 3F, 4 W LINE 3F, 4 W
A B C N
•
•
LINE LINE LINE
A B C A B C A B C N
•
•
•
•
•
•
•
•
•
•
•
•
•
1 2 3 4 5 6 1 2 3 4 5 6 6A 1 2 3 4 5 6 6A 1 2 3 4 5 6 6A
Va Vb Vc Vb N Va Vc N N Va Vc N N
Va Vb Vc
-OUTPUT+ EXT. PWR. -OUTPUT+ EXT. PWR. -OUTPUT+ EXT. PWR. -OUTPUT+ EXT. PWR.
IF REQUIRED IF REQUIRED IF REQUIRED IF REQUIRED
Ia• Ic• Ia Ic Ia• Ic• Ib• Ia Ic Ib Ia• Ic• Ib• Ia Ic Ib Ia• Ic• Ib• Ia Ic Ib
7 8 9 10 11 12 7 8 9 10 11 12 12A 7 8 9 10 11 12 12A 7 8 9 10 11 12 12A
•
•
•
•
•
•
LOAD LOAD
•
LOAD LOAD
LINE
A B C
LINE
A B C
•
•
•
•
1 2 3 4 5 6
Va Vb Vc Vb 1 2 3 4 5 6
-OUTPUT+ EXT. PWR.
IF REQUIRED Va Vb Vc Vb
Ia• Ic• Ia Ic -OUTPUT+ EXT. PWR.
7 8 9 10 11 12 IF REQUIRED
Ia• Ic• Ia Ic
7 8 9 10 11 12
•
Attention:
If the transducer is mounted on a non-metallic or ungrounded surface the installer
•
must provide the means for grounding and bonding as per NEC (National Electric
LOAD Code) requirements.
LOAD
32
Connections
AC Power Transducers
(Combined W/R/Q)
Metal Surface Mount Cases
•
•
•
•
•
•
•
•
•
•
1 2 3 4 5 6 6A 1 2 3 4 5 6 6A
1 2 3 4 5 6 6A 1 2 3 4 5 6 6A Vb Va Vc Va
WATT VAR OR Q EXT. PWR. WATT VAR OR Q EXT. PWR.
V V• I I• V V• I I• -OUTPUT+ -OUTPUT+ IF REQUIRED -OUTPUT+ -OUTPUT+ IF REQUIRED
WATT
VAR OR Q EXT. PWR.
WATT
VAR OR Q EXT. PWR. Ia• Ic• Ia Ic Ia Ic
-OUTPUT+ -OUTPUT+
-OUTPUT+ IF REQUIRED -OUTPUT+ IF REQUIRED 7 8 9 10 11 12 12A 7 8 9 10 11 12 12A
7 8 9 10 11 12 12A 7 8 9 10 11 12 12A
•
•
•
LOAD LOAD LOAD LOAD
•
•
LINE LINE LINE
A B C A B C A B C N
•
•
•
•
•
•
•
•
•
•
•
•
1 2 3 4 5 6 6A 1 2 3 4 5 6 6A 6B 1 2 3 4 5 6 6A 6B 1 2 3 4 5 6 6A 6B
Vb Va Vc Vb N Va Vc N N Va Vc N N Va Vb Vc
WATT EXT. PWR. WATT VAR OR Q - EXT. PWR. WATT VAR OR Q - EXT. PWR. WATT VAR OR Q - EXT. PWR.
-OUTPUT+ VAR OR Q IF REQUIRED -OUTPUT+ OUTPUT + IF REQUIRED -OUTPUT+ OUTPUT + IF REQUIRED -OUTPUT+ OUTPUT + IF REQUIR
Ia• Ic• -OUTPUT+ Ia• Ic• Ib• Ia Ic Ib Ia• Ic• Ib• Ia Ic Ib Ia• Ic• Ib• Ia Ic Ib
7 8 9 10 11 12 12A 7 8 9 10 11 12 12A 12B 7 8 9 10 11 12 12A 12B 7 8 9 10 11 12 12A 12B
•
•
•
•
•
LOAD LOAD
•
LOAD LOAD
LINE LINE
A B C A B C
•
•
•
•
1 2 3 4 5 6 6A 1 2 3 4 5 6 6A
Vb Va Vc Vb Vb Va Vc Vb
WATT EXT. PWR. WATT EXT. PWR.
-OUTPUT+ VAR OR Q IF REQUIRED -OUTPUT+ VAR OR Q IF REQUIRED
Ia• Ic• -OUTPUT+ -OUTPUT+
Ia• Ic•
7 8 9 10 11 12 12A 7 8 9 10 11 12 12A
•
Attention:
If the transducer is mounted on a non-metallic or ungrounded surface the installer
•
must provide the means for grounding and bonding as per NEC (National Electric
LOAD LOAD Code) requirements.
33
Connections
AC Energy Transducers
(Single Output)
Metal Surface Mount Cases
LINE 1 ELEMENT LINE 11⁄2 ELEMENT LINE 2 ELEMENT
A B C A B C
1F, 2 W 3F, 3 W 3F, 3 W
•
•
•
•
•
•
•
•
UP UP
UP 1 2 3 4 5 6 6A 6B 1 2 3 4 5 6 6A 6B
6C 6C
1 2 3 4 5 6 6A 6B Vc Va Va Vb Vc Vb
-OUTPUT+ EXT. PWR. 6D -OUTPUT+ EXT. PWR. 6D
6C
V V• I I• IF REQUIRED 12B IF REQUIRED 12B
-OUTPUT+ 6D Ia• Ic• Ia Ic Ia• Ic• Ia Ic
EXT. PWR. 12C 12C
IF REQUIRED 12B 7 8 9 10 11 12 12A 7 8 9 10 11 12 12A
12D 12D
12C
7 8 9 10 11 12 12A 12D
•
•
•
•
LOAD LOAD LOAD
•
•
LINE LINE
A B C A B C N
•
•
•
•
•
•
•
•
UP UP UP
1 2 3 4 5 6 6A 6B 1 2 3 4 5 6 6A 6B 1 2 3 4 5 6 6A 6B
6C 6C 6C
N Va Vc N N Va Vc N
-OUTPUT+ 6D -OUTPUT+ 6D -OUTPUT+ 6D
EXT. PWR. EXT. PWR. EXT. PWR.
IF REQUIRED 12B IF REQUIRED 12B IF REQUIRED 12B
Ia• Ic• Ib• Ia Ic Ib 12C Ia• Ic• Ib• Ia Ic Ib 12C Ia• Ic• Ib• Ia Ic Ib 12C
7 8 9 10 11 12 12A 12D 7 8 9 10 11 12 12A 12D 7 8 9 10 11 12 12A 12D
•
•
•
•
LOAD
•
LOAD LOAD
UP Attention:
1 2 3 4 5 6 6A 6B If the transducer is mounted on a non-metallic or
6D
+15V 3 8 6C
2+ 5 6D ungrounded surface the installer must provide the
-OUTPUT+ 6D
12B
means for grounding and bonding as per NEC
12C (National Electric Code) requirements.
7 8 9 10 11 12 12A 12D
LOAD
34
Connections
AC Energy Transducers
(Combined W/R/Q)
Metal Surface Mount Cases
1 ELEMENT 11⁄2 ELEMENT 2 ELEMENT
1F, 2 W 3F, 3 W 3F, 3 W
•
•
UP 6B 6B
6C 6C
•
6B
6D 6D
•
6C
•
12B 12B
6D
•
12C 12C
•
12B
12D 12D
12C
12D 1 2 3 4 5 6 6A 6B 1 2 3 4 5 6 6A 6B
1 2 3 4 5 6 6A 6B Vc V Vb Va Vc Vb
WATT VAR OR Q - EXT. PWR. WATT VAR OR Q - EXT. PWR.
V V• I I• -OUTPUT+ OUTPUT + IF REQUIRED -OUTPUT+ OUTPUT + IF REQUIRED
WATT VAR OR Q - EXT. PWR. Ia• Ic• Ia Ic Ia• Ic• Ia Ic
-OUTPUT+ OUTPUT + IF REQUIRED 7 8 9 10 11 12 12A 12B 7 8 9 10 11 12 12A 12B
6B 6B
7 8 9 10 11 12 12A 12B
6C 6C
•
•
6B
6D 6D
6C
12B 12B
6D
12C 12C
•
•
12B
12D 12D
12C
LOAD 12D LOAD LOAD
•
•
LINE LINE
A B C A B C N
UP UP UP
•
•
•
•
6B 6B 6B
6C 6C 6C
6D 6D 6D
•
•
•
•
12B 12B 12B
12C 12C 12C
12D 12D 12D
1 2 3 4 5 6 6A 6B 1 2 3 4 5 6 6A 6B 1 2 3 4 5 6 6A 6B
N Va Vc N N Va Vc N N Va Vb Vc
WATT VAR OR Q - EXT. PWR. WATT VAR OR Q - EXT. PWR. WATT VAR OR Q - EXT. PWR.
-OUTPUT+ OUTPUT + IF REQUIRED -OUTPUT+ OUTPUT + IF REQUIRED -OUTPUT+ OUTPUT + IF REQUIRED
Ia• Ic• Ib• Ia Ic Ib Ia• Ic• Ib• Ia Ic Ib Ia• Ic• Ib• Ia Ic Ib
7 8 9 10 11 12 12A 12B 7 8 9 10 11 12 12A 12B 7 8 9 10 11 12 12A 12B
6B 6B 6B
6C 6C 6C
•
6D 6D 6D
12B 12B 12B
12C 12C 12C
•
LOAD LOAD
+15V
OUTPUT 1
1 The arrow shows the direction of the mercury
wetted relay output.
2+ 5 6B UP
3 8 6B 6B 2 The reverse direction is used only for bi-
directional pulse outputs.
6C
6D For supply connections use No. 14 AWG or larger
6C 6C 12B
•
2
35
Connections
•
• •
• •
•
•
•
-16 +15 1 3 2 5 +13 -14 -16 +15 1 3 2 5 +13 -14 -16 +15 1 3 2 5 +13 -14
I• I V• V I• I V• V Va• Va Vb• Vb
-OUTPUT+ EXT. PWR. OUTPUT EXT. PWR. -OUTPUT+ EXT. PWR.
IF REQUIRED IF REQUIRED IF REQUIRED
N1 L1 N2 L2
LINE LINE
POWER FACTOR POWER FACTOR PHASE ANGLE
DIRECT CONNECTION DIRECT CONNECTION DIRECT CONNECTION
SINGLE PHASE THREE PHASE 3 WIRE SINGLE PHASE
OR LOAD OR LOAD
THREE PHASE 4 WIRE THREE PHASE 4 WIRE
C C
B B
LINE A LOAD LINE A LOAD
N
-16 +15 1 3 2 5 +13 -14 -16 +15 1 3 2 5 +13 -14 -16 +15 1 3 2 5 +13 -14
I• I V• V I• I V• V Va• Va Vb• Vb
-OUTPUT+ EXT. PWR. -OUTPUT+ EXT. PWR. -OUTPUT+ EXT. PWR.
IF REQUIRED IF REQUIRED IF REQUIRED
N1 L1 N2 L2
LINE LINE
•
•
•
•
•
1 2 3 4 5 6 7 8
1 2 3 4 5 6 1 2 3 4 5 6 V• V I• I
Va• Va Vb• Vb Va• Va Vb• Vb -OUTPUT+ EXT. PWR.
-OUTPUT+ -OUTPUT+
N1 L1 N2 L2 N1 L1 N2 L2
LINE LINE LINE LINE
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
V• V I• I V• V I• I V• V I• I
-OUTPUT+ EXT. PWR. -OUTPUT+ EXT. PWR. -OUTPUT+ EXT. PWR.
36
Connections
Frequency Transducers
DIN Rail Mount Cases Metal Surface Mount Cases
LOAD
LOAD
DC AUX. PWR.
+15 -16 2 5 +13 -14 OUTPUT IF REQUIRED
L N
L N LINE
LINE
RTD/Slidewire Transducers
DIN Rail Mount Cases Metal Surface Mount Cases
6 7 8 9 10 6 7 8 9 10
5 6 7 8 5 6 7 8
- -
INPUT INPUT - -
VARIABLE RESISTOR RTD INPUT INPUT
VARIABLE RESISTOR RTD
16 15 5 2 14 13 -1 +2 -3 +4 -5 +6 -1 +2 -3 +4 5 6 -7 +8
GRND. REF.
ALARM
- FAULT RESET + FAULT
Notes: Attention:
1. For supply connections use No. 14 AWG or larger wires rated for at least 75°C If the transducer is mounted on a non-metallic or ungrounded surface the installer
(167°F). Use copper conductors only. must provide the means for grounding and bonding as per NEC (National Electric
Code) requirements.
37
Connections
LINE ALARM
CBA ANALOG OUTPUTS ALARM OUTPUTS RESET (N.O)
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25 26
•
•
•
SENSOR OR PT - +
LOAD AUXILIARY POWER
Notes:
1. All transducers need an auxiliary power source. 5. The negative terminals of all analog outputs and the alarm reset are common
2. Not all connections are available on all models. Unused terminals are left internally.
unconnected internally. Attention:
3. The polarity indicated for the alarm reset terminals applies to solid-state If the transducer is mounted on a non-metallic or ungrounded surface the installer
switching device. must provide the means for grounding and bonding as per NEC (National Electric
4. The polarity indicated for the auxiliary power applies to DC sources. Code) requirements.
+ -
PHASE POWER NEUTRAL
CURRENT FACTOR ALARM
ALARM + CONNECTIONS FOR PHASE B AND C IDENTICAL TO PHASE A
- OUTPUT + -
CURRENT VOLTAGE ALARM
OUTPUT OUTPUT RESET
38
mTech: measurement technologies for
the power and process industries.
WARRANTY
Measurement Technologies, Ltd. (mTech) warrants this
product to be free from all latent defects in material and
workmanship under normal use and service. Should this
product be found within one (1) year from date of shipment
to be defective, mTech will repair such part and return to
buyer FOB mTech’s plant or will furnish FOB mTech’s plant a
similar product to replace it, provided written notice of such
defect is given to mTech within ten (10) days after discovery
of such defect and provided the original part is returned to
mTech’s plant with transportation charges prepaid.