Professional Documents
Culture Documents
Astm C585
Astm C585
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 07:34:58 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.
C 585 – 90 (2004)
5.3.1 Nominal outer diameters for nominal sizes of pipe are 6. Keywords
shown in Table 3 and Table 4 and tubing in Table 5 and Table 6.1 pipe thermal insulation diameter; pipe thermal insula-
6. It should be noted that these values for both pipe and tubing tion dimension; pipe thermal insulation thickness; thermal
are identical with iron pipe outer diameters as shown in insulation; thermal insulating materials-pipe; thermal insulat-
Columns 2 and 3 of Table 3 and Table 4. Table 3, Table 4, Table ing materials-rigid; tubing thermal insulation thickness
5, and Table 6 are for nesting purposes only. When product is
to be nested, it shall be so stated on order.
5.3.2 Suggested maximum outer diameters for nominal
sizes of pipe are shown in Table 7 and Table 8 and tubing in
Table 9 and Table 10. Table 7, Table 8, Table 9, and Table 10
are for jacketing purposes only.
5.4 Approximate Insulation Wall Thickness:
5.4.1 For information purposes, the wall thicknesses of pipe
insulation obtained by subtracting inner diameters in Table 1
from corresponding outer diameters in Table 3 and Table 4, and
dividing the results by two, are shown in Table 11. Correspond-
ing values for tubing are shown in Table 12.
2
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 07:34:58 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.
C 585 – 90 (2004)
3
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 07:34:58 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.
C 585 – 90 (2004)
TABLE 2 Inner Diameter of Insulation Tubes
Tube Insulation
Tolerance
Nominal Size Outer Diameter Inner Diameter
Minus Plus
in. in. mm in. mm in. mm in. mm
38 ⁄ 0.500 12.7 0.52 13 0 0 ⁄
1 16 1.6
12 ⁄ 0.625 15.9 0.64 16 0 0 ⁄
1 16 1.6
34 ⁄ 0.875 22.2 0.89 23 0 0 ⁄
1 16 1.6
1 1.125 28.6 1.14 29 0 0 1⁄16 1.6
11⁄4 1.375 34.9 1.39 35 0 0 1⁄16 1.6
11⁄2 1.625 41.3 1.64 42 0 0 1⁄16 1.6
2 2.125 54.0 2.16 55 0 0 1⁄16 1.6
21⁄2 2.625 66.7 2.66 68 0 0 1⁄16 1.6
3 3.125 79.4 3.16 80 0 0 1⁄16 1.6
31⁄2 3.625 92.1 3.66 93 0 0 1⁄16 1.6
4 4.125 104.8 4.16 106 1⁄32 0.8 3⁄32 2.4
5 5.125 130.2 5.16 131 1⁄32 0.8 3⁄32 2.4
6 6.125 155.6 6.20 157 1⁄32 0.8 3⁄32 2.4
TABLE 3 Outer Diameters of Insulation for Nominal Pipe Sizes (NPS), in.
Pipe Insulation, Nominal Thickness
4
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 07:34:58 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.
C 585 – 90 (2004)
TABLE 4 Outer Diameters of Insulation for Nominal Pipe Sizes (NPS), mm
Pipe Insulation, Nominal Thickness
5
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 07:34:58 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.
C 585 – 90 (2004)
TABLE 6 Outer Diameters of Insulation for Tubes, mm
Tube Insulation, Nominal Thickness
TABLE 7 Outer Diameters of Insulation for Nominal Pipe Sizes (NPS), maximum, in.
Pipe Insulation, Nominal Thickness
Nominal in. 1 11⁄2 2 21⁄2 3 31⁄2 4 41⁄2 5
Size
mm 25 38 51 64 76 89 102 114 127
in. Outer Diameter, in.A
⁄
12 3.25 4.38 5.38 7 8 9 10 11.13 12.13
⁄
34 3.25 4.38 5.38 7 8 9 10 11.13 12.13
1 3.88 4.88 6 7 8 9 10 11.13 12.13
11⁄4 3.88 5.38 6 7 8 9 10 11.13 12.13
11⁄2 4.38 5.38 7 8 9 10 11.13 12.13 13.13
2 4.88 6 7 8 9 10 11.13 12.13 13.13
21⁄2 5.38 7 8 9 10 11.13 12.13 13.13 14.38
3 6 7 8 9 10 11.13 12.13 13.13 14.38
31⁄2 7 8 9 10 11.13 12.13 13.13 13.13 14.38
4 7 8 9 10 11.13 12.13 13.13 14.38 15.38
41⁄2 8 9 10 11.13 12.13 13.13 14.38 14.38 15.38
5 9 9 10 11.13 12.13 13.13 14.38 15.38 16.38
6 9 10 11.13 12.13 13.13 14.38 15.38 16.38 17.38
7 ... 11.13 12.13 13.13 14.38 15.38 16.38 17.38 18.38
8 ... 12.13 13.13 14.38 15.38 16.38 17.38 18.38 19.38
9 ... 13.13 14.38 15.38 16.38 17.38 18.38 19.38 20.38
10 ... 14.38 15.38 16.38 17.38 18.38 19.38 20.38 21.38
11 ... 15.38 16.38 17.38 18.38 19.38 20.38 21.38 22.38
12 ... 16.38 17.38 18.38 19.38 20.38 21.38 22.38 23.38
14B ... 17.50 18.50 19.50 20.50 21.50 22.50 23.50 24.50
A
These are identical with pipe outer diameters (see Table 1, Columns 2 and 3).
B
Larger sizes through 36 in., in 1-in. (25.4-mm) increments.
6
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 07:34:58 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.
C 585 – 90 (2004)
TABLE 8 Outer Diameters of Insulation for Nominal Pipe Sizes (NPS), maximum, mm
Pipe Insulation, Nominal Thickness
Nominal in. 1 11⁄2 2 21⁄2 3 31⁄2 4 41⁄2 5
Size
mm 25 38 51 64 76 89 102 114 127
in. Outer Diameter, mmA
⁄
12 83 112 137 178 203 229 254 283 308
⁄
34 83 112 137 178 203 229 254 283 308
1 99 124 153 178 203 229 254 283 308
11⁄4 99 137 153 178 203 229 254 283 308
11⁄2 112 137 178 203 229 254 283 308 334
2 124 153 178 203 229 254 283 308 334
21⁄2 137 178 203 229 254 283 308 334 365
3 153 178 203 229 254 283 308 334 365
31⁄2 178 203 229 254 283 308 334 365 391
4 178 203 229 254 283 308 334 365 391
41⁄2 203 229 254 283 308 334 365 391 416
5 229 229 254 283 308 334 365 391 416
6 229 254 283 308 334 365 391 416 441
7 ... 283 308 334 365 391 416 441 467
8 ... 308 334 365 391 416 441 467 492
9 ... 334 365 391 416 441 467 492 518
10 ... 365 391 416 441 467 492 518 543
11 ... 391 416 441 467 492 518 543 568
12 ... 416 441 467 492 518 543 568 594
14B ... 445 470 495 521 546 572 597 622
A
These are identical with pipe outer diameters (see Table 1, Columns 2 and 3).
B
Larger sizes through 36 in. in 1-in. (25.4-mm) increments.
7
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 07:34:58 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.
C 585 – 90 (2004)
TABLE 10 Outer Diameters of Insulation for Tubes, Maximum, mm
Tube Insulation, Nominal Thickness
8
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 07:34:58 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.
C 585 – 90 (2004)
TABLE 12 Approximate Wall Thickness of Insulation for Tubes
Tube Insulation, Nominal Thickness
in. 1 11⁄2 2 21⁄2 3 31⁄2 4 41⁄2 5
Nominal
mm 25 38 51 64 76 89 102 114 127
Size
Approximate Wall Thickness
in. in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm
⁄
38 0.93 24 1.49 38 1.99 51 2.52 64 3.05 77 ... ... ... ... ... ... ... ...
1⁄2 1.12 28 1.43 36 1.93 49 2.46 62 2.99 76 ... ... ... ... ... ... ... ...
3⁄4 1.00 25 1.56 40 2.06 52 2.86 73 3.36 85 3.87 98 4.37 111 4.93 125 5.43 138
1 0.87 22 1.43 36 1.93 49 2.74 70 3.24 82 3.74 95 4.24 108 4.81 122 5.31 135
11⁄4 1.06 27 1.56 40 2.08 53 2.62 67 3.12 79 3.62 92 4.12 105 4.68 119 5.18 132
11⁄2 0.93 24 1.43 36 1.96 50 2.49 63 2.99 76 3.49 89 3.99 101 4.55 116 5.06 129
2 0.92 23 1.42 36 2.23 57 2.73 69 3.23 82 3.73 95 4.30 109 4.80 122 5.30 135
21⁄2 0.92 23 1.45 37 1.98 50 2.48 63 2.98 76 3.48 88 4.04 103 4.55 116 5.05 128
3 0.92 23 1.73 44 2.23 57 2.73 69 3.23 82 3.80 97 4.30 109 4.80 122 5.42 138
31⁄2 0.95 24 1.48 38 1.98 50 2.48 63 2.98 76 3.54 90 4.04 103 4.55 116 5.17 131
4 1.23 31 1.73 44 2.23 57 2.73 69 3.30 84 3.80 97 4.30 109 4.92 125 5.42 138
5 1.23 31 1.73 44 2.23 57 2.80 71 3.30 84 3.80 97 4.42 112 4.92 125 5.42 138
6 1.21 31 1.71 43 2.28 58 2.78 71 3.28 83 3.90 99 4.40 112 4.90 125 5.40 137
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org).
9
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 07:34:58 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.