r

ACU
r 6 CO
5
4

S3

CO CO CO
S1
P P P

S1 S1

S2
S1 CO

CO CO
1
ACU

S2
WP

LIGHTING LAYOUT PLAN POWER LAYOUT PLAN


SCALE 1:75 SCALE 1:75

TITLE: NAME: COURSE AND SECTION: SHEET NO.

ELECTRICAL PLAN OF A RESIDENTIAL BUNGALOW HOUSE SOLANOY, JILIANE LUISZ S. BSCE 2-1

PUP SUBJECT:

ELECTRICAL UTILITIES
PROFESSOR:

ENGR. MICHAEL GONZALES


DATE:

FEBRUARY 13, 2024


1
SERVICE ENTRANCE

KWHM
ENTRANCE CAP POWER SERVICE
ENTRANCE 230V,
1Ø, 3W 60HZ

VERIFY
3/4" Ø RSC

R.C. TERMINAL 13-100w LIGHTING 2GANG -CONVENIENCE


POST 1 15A 20A 2
OUTLET OUTLET

KILOWATT
M HOUR METER ACU OUTLET 1.5 HP 3 30A 30A 4 ACU OUTLET 1.5 HP

REF OUTLET 1HP 5 30A 30A 6 RANGE OUTLET


1.50

LP
7 8
SPARE SPARE
GRADE LINE

15mm Ø x 3.0 M COPPER


1.20

CLAD GRD ROD


0.25

900 mm X 900 mm RC
FOOTING WITH
5-16mm O RSB BOTHWAY

PANEL DIAGRAM
SINGLE LINE DIAGRAM SCALE 1:100
SCALE 1:100

TITLE: NAME: COURSE AND SECTION: SHEET NO.

ELECTRICAL PLAN OF A RESIDENTIAL BUNGALOW HOUSE SOLANOY, JILIANE LUISZ S. BSCE 2-1

PUP SUBJECT:

ELECTRICAL UTILITIES
PROFESSOR:

ENGR. MICHAEL GONZALES


DATE:

FEBRUARY 13, 2024


2
ELECTRICAL SYMBOLS
SYMBOL DESCRIPTION SYMBOL DESCRIPTION

P
PIN LIGHT S1 SINGLE GANG SWITCH

CEILING LIGHT S2 DOUBLE GANG SWITCH

WALL LAMPS S3 THREE GANG SWITCH

FLOURESCENT SWITCH LINE

CONVENEINCE OUTLET CIRCUIT LINE RUN INSIDE WALL OR UNDER FLOOR BREAKER LOAD COPPER COPPER CONDUIT
CO
CAPACITY ALLOWED WIRE(mm²) THWN 75° C THWN 90° C (mm)
WEATHER PROOF OUTLET CIRCUIT LINE RUN INSIDE WALL OR OVER CEILING
WP 15 12 2.0 20 25 15
REFRIGERATOR OUTLET LOAD PANEL 20 16 3.5 25 30 15 HOUSEPOWER 230 VOLTS WATTS
Ref LP
30 24 5.5 35 40 15 1/6 2.2 506
RANGE OUTLET SERVICE ENTRANCE
r SE
40 32 8.0 50 60 20 1/4 2.9 677
ACU
AIRCONDITION UNIT OUTLET M METER BOARD / KILO WATT HOUR
1/3 3.6 828
60 48 14 65 75 25
1/5 4.9 1127
75 56 22 85 95 25
CIRCUIT HOMERUN 2/4 6.9 1587
100 80 30 100 115 32 1 8.0 1840
125 96 38 115 130 32 1 1/2 10 2300
150 120 50 140 150 40 2 12 2760
140 170 3 17 3910
175 60 155 40
5 28 6440
LEGENDS 200 160 80 190 205 50
7 1/2 40 9200
SCALE NTS 225 180 100 220 240 50
10 50 11500
250 200 125 255 285 65
275 220 150 285 320 65
SHEDULE OF LOAD & COMPUTATION 240
300 175 305 345 65
CKT. DEMAND LOAD VOLTAGE CURRENT CB RATING 260 360
DESCRIPTION WIRE & CONDUIT SIZE 325 200 325 65
NO. (VA) (V) (A)
AT P AF
350 280 250 425 425 80
1 13-100w LIGHTING OUTLET 1300 230 5.65 15 2 50 2-2.0mm² THWN IN 15mmØ PVC

2 2GANG -CONVENIENCE OUTLET 2880 230 12.52 20 2 50 2-3.5mm² THWN IN 15mmØ PVC

3 ACU OUTLET 1.5 HP 2300 230 10 30 2 50 2-5.5mm² THWN IN 15mmØ PVC

4 ACU OUTLET 1.5 HP 2300 230 10 30 2 50 2-5.5mm² THWN IN 15mmØ PVC

5 REF OUTLET 1HP 1840 230 8 30 2 50 2-5.5mm² THWN IN 15mmØ PVC

6 RANGE OUTLET 5000 230 21.73 30 2 50 2-5.5mm² THWN IN 15mmØ PVC

TOTAL CONNECTION LOAD 15,620 77.9


CIRCUIT BREAKER
ALLYING DEMAND FACTOR OF 80%IN EXCESS FOR MAIN PANEL PROTCTION USED :
SCALE NTS
IT: 15,620 x 0.80 =12,496 MINIMUM AMPACITY OF MAIN FEEDER: 2P-75 AMP ACB
12,496/230 = 54.33 I=75AMP (0.80)
IT : 54.33AMP. I=56AMP FOR MAIN FEEDER WIRE LINE
USED :2-22mm² THWN IN 25mm Ø RSC

SCHEDULE OF LOADS AND COMPUTATION


SCALE NTS

TITLE: NAME: COURSE AND SECTION: SHEET NO.

ELECTRICAL PLAN OF A RESIDENTIAL BUNGALOW HOUSE SOLANOY, JILIANE LUISZ S. BSCE 2-1

PUP SUBJECT:

ELECTRICAL UTILITIES
PROFESSOR:

ENGR. MICHAEL GONZALES


DATE:

FEBRUARY 13, 2024


3