INTRODUCTION
We use and distribute our water for many purposes via a public water supply network that is becoming increasingly
more complex. Consumers from all walks of life are connected to this network, which entails significant
contamination risks for drinking water supply and distribution systems. This calls for innovative and watertight
security solutions that meet today’s demands. For this, Watts Industries is exactly what you’re looking for.
INTRODUCTION
The European Ministry of Health have issued There are two conditions which can give rise to a similar
regulations and acts providing local administrations contamination:
and private individuals with preventive and control s CONTACT BETWEEN NON DRINKABLE WATER AND DRINKING
measures against pollution of drinking water. water 5
s RISK OF RETURN OF POLLUTANTS TO THE DRINKING WATER SUPPLY
'ENERAL COMMENT lTTINGS WITH ATMOSPHERIC AERATION EG !! "! #! MAY NOT BE USED IF THERE IS A RISK OF mOODING
● eliminates the risk or allowed as safety fitting
DOES NOT ELIMINATE THE RISK NOT ALLOWED AS SAFETY lTTING
O eliminates the risk only if p = atm
X not applicable
Liquid classes *
* With regard to contact between drinking water and contamination, it is assumed that the connection is always permanent. This means that the situation Pc (Permanent/
continuous) should always be assumed for the risk analysis method.
** LD = Lethal Dose
DRINKING WATER PROTECTION
AB PROTECTION
Standardisation
The AB Break Unit is developed in accordance with EN 1717
and EN 13077.
Installation instructions
Install this Break Unit in accordance with EN 1717.
Dimensions HUV1 DPV(M)E Material specifications AB Break Unit for drinking water
Reservoir in Pump type DPV or DPV(M)E
stainless steel H1 H2 H3 B1 B2 Suction pipe copper / brass
PN10 RVS 150 L 1,040 90 490 550 850 Pressure pipe stainless steel 304
PN10 RVS 500 L 1,705 130 1,242 700 900 Storage tank Stainless steel 316
PN10 RVS 1000 L 1,703 130 1,242 680 1,450 Membrane tank suitable for drinking water
"ACKmOW PREVENTION THE UNIT COMES WITH A SPRING LOADED
Specifications AB Break Unit control panel (functions) BACKmOW PREVENTION SYSTEM
Thermal motor protection
-ANUAL AUTOMATIC SWITCH Technical specifications AB Break Unit for drinking water
%LECTRODE RELAY FOR LEVEL CONTROL AND DRY RUN PROTECTION Liquid temperature up to 60 °C
Fault indicator “thermally off” and “no water” Pump discharge head depends on the selected pump
!DJUSTABLE mOAT TIME Pressure reference switch 30 kPa differential gap
Pressure class of entire system PN 10
DRINKING WATER PROTECTION
AB PROTECTION
4HIS PROTECTION UNIT WITH THE HIGHEST RISK COVERING CAPACITY ENSURES
that a class 5 liquid can never come into contact with the water in the
drinking water supply pipe.
Standardisation
The AB HUV1 DPV(M)E and AB HUV1 DPJ Break Units are
developed in accordance with EN 1717 and EN 13077.
Technical specifications AB HUV1 DPV(M)E and HUV1 DPJ Material specifications AB HUV1 DPV(M)E and HUV1 DPJ
Liquid temperature type DPV(M)E up to 60 °C !LL PARTS IN CONTACT WITH DRINKING WATER CORROSION FREE MATERIALS
type DPJ up to 45 °C Reservoir HDPE (process water)
Pump discharge head depends on the SS (drinking water)
selected pump Reservoir cover + inspection hatch HDPE
Pressure reference switch 30 kPa differential gap
Pressure class of entire unit PN 10 Technical specifications AB HUV1 DPV(M)E and HUV1 DPJ control panel (functions)
Pressure connection 22 mm Thermal motor protection
$RINKING WATER SUPPLY PIPE MALE -ANUAL AUTOMATIC SWITCH
/VERmOW MM 06# ,EVEL CONTROL AND DRY RUN PROTECTION TYPE $06- % ELECTRODE RELAYS
&ILLINGDRAIN TAP X MM HOSE TYPE $0* mOAT SWITCH
Hose on filling/drain tap 15 mm Fault indication “thermally off” and “no water”
Input voltage 230 V AC !DJUSTABLE mOAT TIME
Reservoir volume depends on the capacity
DRINKING WATER PROTECTION
AB PROTECTION
30
DPJ 45 0,45 kW
25
20
15
10
0
0 0.25 0.5 0.75 1 1.25 1.5 Q [l/s]
202
1087
822
605
693
380
325
300
45
50
90 125
AB PROTECTION
800
This protective device can therefore be used, 2/30 2,2 kW
2/22 2,2 kW
Advantages 150
2/20 1,5 kW
2/18 1,5 kW
s COMPACT DIMENSIONS DUE TO MODULAR Total Dynamic Head
(TDH) 2/16 1,5 kW
400
100
s CAPACITIES SEE PUMP CURVE 2/12 1,1 kW
2/11 1,1 kW
[ft]
2/10 0,75 kW
$IFFERING MODELS AVAILABLE ON REQUEST 2/9 0,75 kW
s FAVOURABLE PRICING 50
2/7 0,55 kW
2/6 0,55 kW
2/5 0,37 kW
2/4 0,37 kW
[m] 2/3 0,37 kW
2/2 0,37 kW
0 0
0.0 0.5 [m³/h] 1.0 1.5 2.0 2.5 3.0 3.5
Eta %
0
0.08
0.1
Power Input
[kW]
0.05 [hp]
0.04
0.02
0.0 0.5 [m³/h] 1.0 1.5 2.0 2.5 3.0 3.5
= 1000.0 kg/m³ Flow 20090370-C/0
0 5 [IM.gpm] 10 15 20 25 0 10 [IM.gpm] 20 30
250 270
800
6/26 5,5 kW
4/26 4,0 kW
250
800
4/24 4,0 kW 6/24 5,5 kW
6/22 5,5 kW
200 4/22 4,0 kW
600
4/18 3,0 kW 6/18 4,0 kW
0 0 0 0
0 1 [m³/h] 2 3 4 5 6 7 0 2 [m³/h] 4 6 8 10
0.0 0.5 [l/s] 1.0 1.5 0.0 0.5 [l/s] 1.0 1.5 2.0 2.5
5 4
10
NPSHR [m] NPSHR [m]
[ft] [ft]
0 0 0 0
80 80
Eta % Eta %
0 0
Power Input
0.2
0.2
Power Input 0.2
0.3
Graphs according to:
[kW]
[hp] [kW] [hp] DIN 2548 class C
= 1000.0 kg/m³
0.0
0 1 [m³/h] 2 3 4 5 6
20090372-C/0
7
0.0
= 1000.0 kg/m³
0.0
0 2 [m³/h] 4 6 8
20090374-D/0
10
0.0
(Z MIN
Flow Flow
DRINKING WATER PROTECTION
AB PROTECTION
1175
B1
10 80
80
H1
159
159
H2
B2 B3 L1
BA PROTECTION
Complete
The new BA BM range is also available as a complete BA protection unit,
including tundish, strainer and two stop valves in a single package. As a
result, you the user will have all the components required for installation,
which saves valuable time and money.
DRINKING WATER PROTECTION
BA PROTECTION
12 4HE "! "3 BACKmOW PREVENTION DEVICE IS SPECIALLY DESIGNED FOR LOW
mOW RATE APPLICATIONS 4HE "! "3 FOR EXAMPLE IS HIGHLY SUITABLE FOR
dentists’ chairs and soap dispensers.
Standardisation
The BA BS is developed in accordance with EN 1717 and EN 12729.
Installation instructions
Install the BA BS according to EN1717.
150
140
BS006 BS008
130
120
BS010
110
100
90
80
70
60
50
40
30
20
10
0
0 0,2 0,4 0,6 0,8 1 1,2 1,4
Flow [m3/h]
EN 12729 BS 006 BS 008 BS 010
BA PROTECTION
Standardisation
The BA BM is developed in accordance with EN 1717 and
EN 12729.
Installation instructions
Install the BA BM according to EN 1717.
150
140
130
120
110
100
90
80
BM 015-020 BM 025-032 BM 040-050
70
60
50
40
L2 30
20
10
2 0
0 1 10 100
1 3 Flow [m3/h]
EN 12729 BM 015-020 BM 025-032 BM 040-050
H3
R
R
H1
H2
BA PROTECTION
Standardisation
Dimensions BA 4760 The BA 4760 is developed in accordance with EN 1717 and EN 12729.
Installation instructions
Install the BA 4760 in accordance with EN1717. A BA device should
BE MOUNTED WITH STRAINER AND SHUT OFF VALVES TO ENABLE A PERIODIC
functional testing.
Sylax lug type butterfly valve Y333P strainer with relief valve
Article number Type Article number Type
600011686 Sylax lug DN65 600003282 Y333P DN65
600011691 Sylax lug DN80 600003283 Y333P DN80
600011696 Sylax lug DN100 600003284 Y333P DN100
600041489 Sylax lug DN150 600003286 Y333P DN150
600041490 Sylax lug DN200 600003287 Y333P DN200
600041491 Sylax lug DN250 600003288 Y333P DN250
BA PROTECTION
Inlet Outlet
Relief valve
009DN65
100
90 009DN80
80
70
60
50
40
30
20
10
0
0 10 20 30 40 50 60 70 80
Flow [m3/h]
009DN65 009DN80
Sylax lug type butterfly valve Y333P strainer with relief valve
Article number Type Article number Type
600011686 Sylax lug DN65 600003282 Y333P DN65
600011691 Sylax lug DN80 600003283 Y333P DN80
Article numbers BA 009 DN65 and DN80 Material specifications BA 009 DN65 and DN80
Article number Type Weight in kg Body cast iron with epoxy coating
406065000 BA 009 DN65 39,0 &LANGE BORE ACCORDING TO %. $).
406080000 BA 009 DN80 39,5 Check valve seats plastic
Seals rubber
Approvals BA 009 DN65 en DN80 (device) Relief valve seat stainless steel
UNI, NF, Belgaqua, Kiwa
Technical specifications BA 009 DN65 and DN80
Max. system pressure PN 10 (10 bar)
Nom. operating temperature 60 °C
DRINKING WATER PROTECTION
BA PROTECTION
Basic principle
The BA 909 functions on the basis of maintaining a pressure level in
THE MIDDLE CHAMBER REDUCED PRESSURE ZONE WHICH LIES BELOW THE
pressure on the inlet side of the device.
The picture on the left presents an overview of the most serious
situation that may occur in practice, namely:
s BACKPRESSURE IS PRESENT ON THE OUTLET SIDE
s BACK SIPHONING IS CREATED ON THE INLET SIDE
s BOTH CHECK VALVES ARE UNABLE TO CLOSE COMPLETELY DUE TO DIRT
140
D Flow [m3/h]
909 DN 20 909 DN 25
BA PROTECTION
Delta P [kPa]
120
110 909 DN 65
909 DN 80
100
90
80
70
60
50
40
Vlinderklep Sylax lug type 30
20
Artikelnummer Type 10
Flow [m3/h]
600011691 Sylax lug DN80 909 DN 65 909 DN 80
600011696 Sylax lug DN100
600028006 Sylax lug DN150 Pressure loss curves BA 909 DN100 and DN150
600041489 Sylax lug DN200 130
Delta P [kPa]
120
80
Flow [m3/h]
600003286 Y333P DN150 909 DN 100 909 DN 150
600003287 Y333P DN200
600003288 Y333P DN250 Pressure loss curves BA 909 DN200 and DN250
100
Delta P [kPa]
90 909 DN 200
80
70 909 DN 250
60
50
A D C
40
30
20
10
0
B 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750
Flow [m3/h]
909 DN 200 909 DN 250
Material specifications BA 909 DN65 - 250 Technical specifications BA 909 DN65 - 250
Body cast iron with epoxy coat Max. system pressure PN 10 (10 bar)
Check valve seats plastic Max. operating temperature 45 °C
4EST VALVES BRONZE Peak temperature 60 °C (for 1 hour per day)
2ELIEF VALVE BRONZE
Relief valve guide plastic Approvals BA 909 DN65 - 250
Tundish plastic Belgaqua, KIWA, NF, SVGW, UNI
DRINKING WATER PROTECTION
CA PROTECTION
Standardisation
The CA 9C protection device is developed in accordance with
EN 1717 and EN 14367 (CAa).
Installation instructions
Screen First check Second
Install the CA 9C protection device according to EN 1717.
valve check valve
Inspection
According to national norms, the correct functioning of a CA
BACKmOW PREVENTION DEVICE MUST BE TESTED PERIODICALLY
Functional testing
Provided that the CA9C is installed as a unit, it is possible to check
the correct functioning of the CA 9C.
The integrated sieve on the inlet side of the unit makes sure that the
check valves and relief valve are protected from unnecessary dirt.
! SHUT OFF VALVE WITH A DRAIN TAP MUST BE INSTALLED BEFORE THE
CA 9C. The relief opening must be connected to a drainpipe using
Relief valve Outlet the supplied tundish.
Dimensions
CA 9C DN15 and DN20
H 2
3
Flow rate m3/h debiet M /H
CA PROTECTION
Standardisation
The CA unit is developed in accordance with EN1717 and EN14367
(CAa).
Installation instructions
Install the CA protection device according to EN 1717.
4HE UNIT SHOULD BE INSTALLED HORIZONTALLY WITH THE RELIEF VALVE OPENING
pointed downwards. This opening should be connected to a drain.
4HE VALVE MUST NOT BE LIABLE TO mOODING
Functional testing
A CA device should be checked on its functioning periodically, in
accordance with national standards.
Article numbers and dimensions CA DN15 - DN20 Material specifications CA DN15 - DN20
DN A B C W Body Brass (DZR)
Article number Type DN mm mm mm kg Spring Stainless steel
407015295 #! & v 15 52 99 202 0,85 Seal rubber
407020295 CA F ¾” 20 57 99 204 1,08 Tundish plastic
CA PROTECTION
Standardisation
The CAb protection device is developed in accordance with EN 1717
Dimensions CAb and EN 14367 (CAb).
+0.8 +0.8
74.6 -0.2 63.6 -0.2
Functional testing
M10x1
M10x1
8 8.5 model:
6
model: periodically.
9.5
39 71
7.5
40.4 34.2
27.4 36.2
Installation in OEM applications
The must be installed between two valves. The integrated sieve on
Model 30839 Model 30871
the inlet side of the device ensures that the check valves and relief
+0.8 +0.8
valve are protected from contamination. The six basic models are
58.6 -0.2 71.6 -0.2
G1/4
G1/4
6 6
model: 8 6 model: contact Watts Industries for examples).
48 9.5 7.5 92
7.5 7.5
+0.8
68 -0.2
+0.8
61.6 -0.2
Examples of CAb installation kits
M10x1
Ø11
G1/4
G1/4
model:
model: 6 8.5
54
6 62 7.5
7.5
36.8 31.2 27.4 34.2
Body brass
120
Spring stainless steel
DN6 DN8 DN10
Check valves plastic 100
Seals rubber
80
DP [kPa]
Approvals CAb 60
NF
40
Belgaqua
Kiwa 20
0
Technical specifications CAb 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
Flow [m3/h]
Medium drinking water
EN 14367 30862 30846 30848
.OMINAL DIAMETER $. $.
Nom. operating temperature 65 °C
Peak temperature 90 °C for 1 hour per day
Max. system pressure 1,000 kPa (10 bar)
DRINKING WATER PROTECTION
DA PROTECTION
Advantages
$UE TO ITS SMALL SIZE THE $! !# IS ALSO HIGHLY SUITABLE FOR USE
WITH SMALL mOW RATES FOR EXAMPLE IN LABORATORY EQUIPMENT 4HE USE
OF SPECIAL MATERIALS ALSO MAKES THIS ANTI SIPHON VACUUM BREAKER
suitable for temperatures of up to 85°C. The large, streamlined
DIAMETER ENSURES MAXIMUM mOW AND MINIMUM PRESSURE LOSS 4HE
LIGHTWEIGHT VALVE PREVENTS SPILLAGE FOR ALL mOW CAPACITIES
Installation instructions
s )NSTALL THE $! !# ACCORDING
to the EN 1717.
s 4HE $! MUST BE INSTALLED AFTER
THE SHUT OFF VALVE AND MUST NOT
be under pressure all the time.
s .O SHUT OFF DEVICES MAY BE min.
300 mm
installed downstream from
the DA.
s 4HE $! !# MUST BE
mounted in an accessible
location, to allow the correct
performance of inspections and
maintenance and to prevent
water leaks from causing
nuisance.
Dimensions DA 288A(C)
DN10 - DN65
A
C
2
1
4
B
EA & EB PROTECTION
Design
The check valve consists of:
s BRASS BODY WITH DRAINING AND TEST PORTS
s IF REQUIRED WITH NUTS AND CONNECTION UNIONS
s PLASTIC CHECK VALVE MODULE
s LIP SEAL SEALING PRINCIPLE
s SPLIT VALVE STEM
1 2 3
4
meet EN 13959.
Installation instructions
Druckdifferenz [kPa]
1
0,1 1 10 100 1000
Flow [l/min]
2OUGH VALUES ACCURATE CURVES PER VALVE AVAILABLE ON REQUEST
EA protection Installation
Install the EA protection device after cleaning the pipework in the
prescribed manner. Install the EA protection device in front of the
HAZARDOUS DEVICE 4HIS PREVENTS DIRTY WATER FROM mOWING BACK INTO
the drinking water system.
EB protection
In accordance with the installation instructions of EN 1717,
A SHUT OFF VALVE MUST BE INSTALLED IN FRONT OF THE %! PROTECTION DEVICE
EA PROTECTION
!RTICLE NUMBER 4YPE .OMINAL #ONNECTION SIZES 4OTAL !PPROVALS IF"T 7EIGHT
width length reference kg
DN Inlet x outlet mm
MU Male x female, chrome-plated 23
X +IWA"ELGAQUA
X +IWA"ELGAQUA
PU Male x female
X +IWA"ELGAQUA$6'7 0 )8)
X +IWA"ELGAQUA$6'7 0 )8)
X +IWA"ELGAQUA$6'7 0 )8)
X +IWA"ELGAQUA$6'7 0 )8)
X +IWA"ELGAQUA$6'7
X +IWA"ELGAQUA$6'7
PI Female x female
222010162 10 3⁄ 8 X 3⁄ 8 +IWA"ELGAQUA$6'7 0 )8L
X +IWA"ELGAQUA$6'7 0 )8)
X +IWA"ELGAQUA$6'7 0 )8)
X +IWA"ELGAQUA$6'7 0 )8)
X +IWA"ELGAQUA$6'7 0 )8)
X +IWA"ELGAQUA$6'7
X +IWA"ELGAQUA$6'7
W Male x female
X +IWA$6'7"ELGAQUA
X +IWA$6'7"ELGAQUA
X +IWA$6'7"ELGAQUA
WF Nut x male
X +IWA"ELGAQUA.&
X +IWA"ELGAQUA.&
X +IWA"ELGAQUA.&
X +IWA"ELGAQUA.&
X +IWA"ELGAQUA.&
WH Nut x male
X X +IWA"ELGAQUA.&
X X +IWA"ELGAQUA.&
KF Compression fitting
FOR PIPE SIZE MM +IWA"ELGAQUA
FOR PIPE SIZE MM +IWA"ELGAQUA
FOR PIPE SIZE MM +IWA"ELGAQUA
DRINKING WATER PROTECTION
EA PROTECTION
EB PROTECTION
W Female x male
X +IWA"ELGAQUA$6'7
SHORT X +IWA"ELGAQUA$6'7
LONG X +IWA
Watts Industries can also supply a very wide range of plastic EB check valves:
For more information about these plastic check valves, please refer to the brochure ‘Watts Plastic check valves’.
DRINKING WATER PROTECTION
EA PROTECTION
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8
Flow [m3/h]
CC015 CC020 CC025
EA PROTECTION
EA protection EA CC Basic
The EA CC Basic is a complete EA protection unit, with an
26 integrated closing valve and a test cock at the supply side.
The CC Basic can be used in all places where EA protection is
required.
90
Drukverlies [kPa]
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8
Flow [m3/h]
CC020 Basic CC015 Basic
EA PROTECTION
Installation instructions Pressure loss curve flanged check valves FC065 - FC250
Install the EA FC according to EN 1717. 45
DN65 DN80 DN100 DN125 DN150 DN200 DN250
Delta P [kPa]
40
35
30
25
20
15
0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050
Flow [m³/h]
EN13959 FC065-080-100 FC125-150 FC200-250
Dimensions EA FC
A
C E
D F
CV
B
B
G
B
H
C
402 VALVE
50 1,0
0,9
40 0,8
0,7
[ bar ]
Widerstandsbeiwert
p (bar)
Resistance Coefficient
30 0,6
Pressure loss p
max
0,5
Druckverlust
Resistance
20 0,4 p
0,3
10 0,2
0,1
3
0 10 DN 250
400
DN 50
3 DN 200
DN
5 300
DN
DN 150
DN 125
DN 100
100
[ m /h ]
DN 80
3
Flow Rate [ m /h ] 3
DN 65
50
Flow rate (m /h)
Durchflussmenge
3
DN 50
DN 40
10
1
0,5 0,6 0,7 0,8 0,9 1 2 3 4 5
Flow velocity v (m/s)
DRINKING WATER PROTECTION
30
1
d
d 3
2
d
b
HA PROTECTION
2 2
2
3 3 3
1 1 1
37
HA S8C in closed "EFORE THE mOW STARTS THE Due to the loss of
position. Valve 1 closes openings 3 are closed. pressure in the network,
1 " onto membrane 2. Only than valve 1 opens. valve 1 tightly closes
2
HD PROTECTION
B1
HD NLF9
31 Hot Cold
H > 200 mm
Mixed
Drain
Watts HD N9
Drain
25
32
Technical specifications HD N9 and HD NLF9 Article numbers and material specifications HD N9 en HD NLF9
Max. pressure 10 bar Article number Type DN Model
Max. temperature 60 °C 409003000 HD N9 10 brass 3/8 FEMALE X 3/8 FEMALE
($ .# CHROME PLATED BRASS 3/8 FEMALE X 3/8 FEMALE
($ .,& CHROME PLATED BRASS 3/8 FEMALE X 3/8 MALE
DRINKING WATER PROTECTION
TUNDISH
Tundish BA BM
4UNDISH IN ACCORDANCE WITH %. FOR "! "- BACKmOW PREVENTION
devices. 33
Tundish CA 9C
4UNDISH IN ACCORDANCE WITH %. FOR #! # BACKmOW PREVENTION
devices.
Tundish CA
4UNDISH IN ACCORDANCE WITH %. FOR #! BACKmOW PREVENTION
devices.
STRAINERS
D
N
25
1”
B
Material specifications strainer SMY DN10 - DN50 3PECIlCATIONS lLTER 3-9 $. $.
Body brass !RTICLE NUMBER $. , " -ESH SIZE 7EIGHT
Cover brass mm mm per mm g
Strainer screen stainless steel 900566210 10 55 40 0,40 135
900566215 15 58 40 0,40 145
900566220 20 70 48 0,40 225
900566225 25 87 56 0,40 420
900566232 32 96 64 0,50 605
900566240 40 106 73 0,50 825
900566250 50 126 89 0,50 1,325
Material specifications flanged strainer Y333 Flanged strainer Y333 DN40 - DN400 Screen
$. $. Article number connection A C D Mesh Weight
Body Cast iron with epoxy coating Ø PN mm mm mm mm kg
Strainer stainless steel
Technical specifications flanged strainer Y333
$. $.
Max. system pressure PN10 or PN16
Max. operating temp. 100 °C
&ILTRATION $. MICRONS 900566408
DN65: 800 microns, 900566458
$. MICRONS 900566508
$. MICRONS 900566558
#OVER DELIVERED WITH PLUG ' $. $. AND 900066608
' $. AND
Approvals flanged strainer Y333 DN40 - DN400
72!3 EXCEPT $.
DRINKING WATER PROTECTION
STRAINERS
Material specifictions flanged strainer Y333P Flanged strainer Y333P DN40 - DN400 Screen
$. $. Article number connection A C D Mesh Weight
Body GJL Cast iron with epoxy Ø PN mm mm mm mm kg
coating (DN40 to DN50) 600003280 1 40 16 200 130 35 0,50 6,5
GJS Ductile iron with epoxy 600003281 2 50 16 230 145 50 0,50 8,5
coating (DN60 to DN400)
Strainer stainless steel 600003283 3** 80 16 310 159 75 1,25 13,5
$RAIN COCK BRASS 600003284 4 100 16 350 187 90 1,25 18
600003285 5 125 16 400 249 125 1,25 27,5
Technical specifictions flanged strainer Y333P 600003286 6 150 16 480 301 170 1,25 43
$. $. 600003287 8 200 10 600 403 220 1,25 83
Max. system pressure PN10 of PN16 600003288 10 250 10 730 472 200 1,60 112
Max. operating temp. 100 °C 600003289 12 300 10 850 508 250 1,60 160
&ILTRATION $. MICRONS 600003788 14 350 10 980 587 315 1,60 297
DN65: 800 microns, 600003791 16 400 10 1100 658 370 1,60 406
$. MICRONS * Double drilling DN 65 / DN60
$. MICRONS ** Double drilling: 4 and 8 holes
#OVER DELIVERED WITH PLUG ' $. $. AND
' $. $. Approvals flanged strainer Y333 DN40 - DN400
72!3 EXCEPT $. $.
DRINKING WATER PROTECTION
BUTTERFLY VALVES
Sylax lug
36
C
E
DN
B
A
Approvals butterfly valve Sylax lug type DN50 - DN300 Specifications butterfly valve Sylax lug type DN50 - DN300
In progress: Kiwa, NF Article number connection A B C D E Weight
DN PN mm mm mm mm kg
600028008 50 62 169 200 43 45 3,7
600011686 65 70 178 200 46 45 4,2
600011691 80 89 184 200 46 45 5,1
600011696 100 106 208 200 52 45 7,6
600028007 125 120 223 290 56 65 10,2
600028006 150 131 236 290 56 65 11,7
600041489 200 164 293 450 60 86 23,0
600041490 250 200 318 450 68 86 30,0
600041491 300 235 343 450 78 86 32,2
DRINKING WATER PROTECTION
0.5 0.75
0.25
0 1
differential
pressure gauge BAR
low
high pressure hose pressure (blue)
(yellow) hose
(red)
test valves
1 2 3
shut off valve shut off valve
4 5
The photographs and descriptions in this brochure are purely informative and in no way binding, Watts Industries reserves the right to make any
technical or exterior changes to their products deemed necessary, without prior notification.
DRINKING WATER PROTECTION
38
DRINKING WATER PROTECTION
39
Product range Watts Industries