Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

1 EU-TYPE EXAMINATION CERTIFICATE

2 Equipment intended for use in Potentially Explosive Atmospheres Directive 2014/34/EU


3 Certificate Number: Sira 05ATEX2084X Issue: 9
4 Equipment: IS-mA1 Sounder, IS-mB1 Beacon, IS-mC1 Combined Sounder/Beacon,
IS-mA2 Sounder, IS-mA3 Sounder and IS-mA1M Sounder
5 Applicant: European Safety System Limited
6 Address: Impress House
Mansell Road
Acton
London W3 7QH
UK
7 This equipment and any acceptable variation thereto is specified in the schedule to this certificate and
the documents therein referred to.
8 CSA Group Netherlands B.V., Notified Body Number 2813 in accordance with Articles 17 and 21 of
Directive 2014/34/EU of the European Parliament and of the Council, dated 26 February 2014, certifies
that this equipment has been found to comply with the Essential Health and Safety Requirements relating
to the design and construction of equipment intended for use in potentially explosive atmospheres given
in Annex II to the Directive.
The examination and test results are recorded in the confidential reports listed in Section 14.2.
9 Compliance with the Essential Health and Safety Requirements, with the exception of those listed in the
schedule to this certificate, has been assured by compliance with the following documents:
EN IEC 60079-0:2018 EN 60079-11:2012 IEC 60079-26:2014 Ed 3.0
10 If the sign ‘X’ is placed after the certificate number, it indicates that the equipment is subject to Specific
Conditions of Use identified in the schedule to this certificate.
11 This EU-Type Examination Certificate relates only to the design and construction of the specified
equipment. If applicable, further requirements of this Directive apply to the manufacture and supply of
this equipment.
12 The marking of the equipment shall include the following:
IS-mA1 Sounder, IS-mB1 Beacon, IS-mC1 Combined IS-mA1M Sounder
Sounder/Beacon, IS-mA2 Sounder and IS-mA3 Sounder

II 1 G I M1
Ex ia IIC T4 Ga (-40°C ≤ Ta ≤ +60°C) Ex ia I Ma (-40°C ≤ Ta ≤ +60°C)

Project Number 80019157 Signed: J A May

Title: Director of Operations


This certificate and its schedules may only be CSA Group Netherlands B.V.
reproduced in its entirety and without change Utrechtseweg 310,
6812 AR, Arnhem,
Netherlands

Page 1 of 7
DQD 544.09 Rev 2018-04-20
SCHEDULE

EU-TYPE EXAMINATION CERTIFICATE Sira 05ATEX2084X


Issue 9

13 DESCRIPTION OF EQUIPMENT
The IS-mA1 Sounder is designed to provide an audible warning when activated. It consists of the
following mounted in an IP 65, flame retardant, ABS enclosure:
• Sounder printed circuit board assembly • Inductive sounder transducer
External connections are made to terminals mounted on the sounder printed circuit board via cable entry
devices mounted in the wall of the enclosure. The parameters for the IS-mA1 Sounder are as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Terminal + w.r.t. Terminal - 28 V 93 mA 660 mW 0 0
Terminals S2 and S3 w.r.t. Terminal - 28 V 0 - - -
The IS-mB1 Beacon is designed to provide a flashing warning when activated. It consists the following
mounted inside an IP 65, flame retardant, ABS enclosure that is fitted with a transparent polycarbonate ‘lens’:
• Beacon main printed circuit board assembly • Beacon LED printed circuit board assembly
External connections are made to terminals mounted on the beacon main printed circuit board via cable entry
devices mounted in the walls of the enclosure. The parameters for the IS-mB1 Beacon are as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Terminal + w.r.t. Terminal - 28 V 660 mA 1.2 W 0 0
The IS-mC1 Combined Sounder/Beacon is designed to provide an audible and a flashing warning
when activated. It consists of the following mounted inside an IP 65, flame retardant, ABS enclosure
that is fitted with a transparent polycarbonate ‘lens’:
• Sounder printed circuit board assembly • Beacon main printed circuit board assembly
• Inductive sounder transducer • Beacon LED printed circuit board assembly
External connections are made to terminals mounted on the sounder printed circuit board assembly and
the beacon main printed circuit board assembly via cable entry devices mounted in the walls of the
enclosure. The IS-mC1 Combined Sounder/Beacon may be supplied with internal wiring connections
between Sounder Terminals + / - and Beacon Terminals + / -, alternatively these connections may be
fitted by the user/installer. The parameters for the IS-mC1 Combined Sounder/Beacon are as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Without internal Sounder Terminals + w.r.t. Sounder Terminals - 28 V 93 mA 660 mW 0 0
connections: Sounder Terminals S2 & S3 w.r.t. Sounder Terminals - 28 V 0 - - -
Beacon Terminal + w.r.t. Beacon Terminal - 28V 660 mA 1.2 W 0 0
With internal Sounder Terminal + w.r.t. Sounder Terminal - 28 V 93 mA 660 mW 0 0
connections Sounder Terminals S2 & S3 w.r.t. Sounder Terminals - 28 V 0 - - -

This certificate and its schedules may only be CSA Group Netherlands B.V.
reproduced in its entirety and without change Utrechtseweg 310,
6812 AR, Arnhem Netherlands

DQD 544.09 Rev 2018-04-20 Page 2 of 7


SCHEDULE

EU-TYPE EXAMINATION CERTIFICATE Sira 05ATEX2084X


Issue 9

Variation 1 - This variation introduced the following change:


i. The introduction of two new types of sounder; these are designated the IS-mA2 Sounder and the
IS-mA3 Sounder.
The IS-mA2 Sounder is similar to the original IS-mA1 Sounder, the differences being that it has
a new printed circuit board layout and a new ‘low profile’ enclosure base. Cable entry is via a
‘knockout’ in the bottom of the enclosure base, this enclosure base, and thus the sounder, being
designed for attachment to other equipment.
The parameters of the IS-mA2 Sounder are as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Terminal + w.r.t. Terminal - 28 V 93 mA 660 mW 0 0
Terminals S2 and S3 w.r.t. Terminal - 28 V 0 - - -
The IS-mA3 Sounder is similar to the original IS-mA1 Sounder, the differences being the addition
of several components to the circuit, a different connection arrangement, a new printed circuit board
layout and a new ‘low profile’ enclosure base. Cable entry is via a ‘knockout’ in the bottom of the
enclosure base, this enclosure base, and thus the sounder, being designed for attachment to other
equipment.
The parameters of the IS-mA3 Sounder are as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Terminal + w.r.t. Terminals S2 and S3 28 V 93 mA 660 mW 0 0
Variation 2 - This variation introduced the following change:
i. The introduction of a group I, category M1 version of the IS-mA1M Sounder, this version is known
as the IS-mA1M Sounder and is marked as detailed in section 12, the parameters are as follows:
Terminals Parameters
Ui Ii Pi Ci Li
Terminal + w.r.t. Terminals S2 and S3 28 V 93 mA 660 mW 0 0
Terminals S2 & S3 w.r.t. Terminal - 28 V - - - 0
Variation 3 - This variation introduced the following change:
i. The review and upgrade of the certificates listed to the latest standards: EN 60079-0:2006,
EN 60079-11:2007, EN 60079-26:2007, IEC 60079-0:2007 Ed 5, IEC 60079-11:2006 Ed 5 and
IEC 60079-26:2006.
Variation 4 - This variation introduced the following change:
i. Following appropriate assessment to demonstrate compliance with the latest technical knowledge,
the documents previously listed, EN 60079-0:2006, EN 60079-11:2007and EN 60079-26:2007 were
replaced by EN 60079-0:2012, EN 60079-11:2012 and IEC 60079-26:2014 Ed 3.0.

This certificate and its schedules may only be CSA Group Netherlands B.V.
reproduced in its entirety and without change Utrechtseweg 310,
6812 AR, Arnhem Netherlands

DQD 544.09 Rev 2018-04-20 Page 3 of 7


SCHEDULE

EU-TYPE EXAMINATION CERTIFICATE Sira 05ATEX2084X


Issue 9

Variation 5 - This variation introduced the following change:


i. Following appropriate assessment to demonstrate compliance with the latest technical knowledge, EN
60079-0:2012 was replaced by EN IEC 60079-0:2018.
14 DESCRIPTIVE DOCUMENTS
14.1 Drawings
Refer to Certificate Annexe.
14.2 Associated Sira Reports and Certificate History
Issue Date Report no. Comment
0 4 August 2005 R52A13291A The release of the prime certificate.
1 14 October 2005 R52A14095A Issued to introduce the changes described in report
number R52A14095A.
2 15 November 2005 R52A14305A Re-issued to introduce the changes described in report
number R52A14305A.
3 18 August 2006 R52A15304A Issued to introduce the changes described in report
number R52A15304A.
4 7 November 2006 R52A15480A The introduction of Variation 1.
5 15 January 2007 R52A15912A The introduction of Variation 2.
6 23 November 2009 R20910A This Issue covers the following changes:
• All previously issued certification was rationalised
into a single certificate, Issue 6, Issues 0 to 5
referenced above are only intended to reflect the
history of the previous certification and have not
been issued as documents in this format.
• The introduction of Variation 3.
7 23 February 2015 R70006449C The introduction of Variation 4.
8 15 October 2019 1699 • Transfer of certificate Sira 05ATEX2084X from Sira
Certification Service to CSA Group Netherlands B.V..
• EC Type-Examination Certificate in accordance with
94/9/EC updated to EU Type-Examination
Certificate in accordance with Directive 2014/34/EU.
(In accordance with Article 41 of Directive 2014/34/EU, EC Type-
Examination Certificates referring to 94/9/EC that were in
existence prior to the date of application of 2014/34/EU (20 April
2016) may be referenced as if they were issued in accordance
with Directive 2014/34/EU. Variations to such EC Type-
Examination Certificates may continue to bear the original
certificate number issued prior to 20 April 2016.)
9 10 December 2019 R80019157A The introduction of Variation 5.

This certificate and its schedules may only be CSA Group Netherlands B.V.
reproduced in its entirety and without change Utrechtseweg 310,
6812 AR, Arnhem Netherlands

DQD 544.09 Rev 2018-04-20 Page 4 of 7


SCHEDULE

EU-TYPE EXAMINATION CERTIFICATE Sira 05ATEX2084X


Issue 9

15 SPECIFIC CONDITIONS OF USE (denoted by X after the certificate number)


15.1 Conditions for IS-mA1 Sounder
• The equipment has an ingress protection rating of IP65. However, if it has been supplied without
cable entry devices, then the user shall ensure that the devices that are fitted will provide an ingress
protection that is appropriate to the environment in which it is installed i.e. IP20 or better. If only
one of the two cable entries are used, then the unused entry ‘knockout’ shall be left intact or fitted
with a blanking device that ensures ingress protection appropriate to the environment in which it is
installed i.e. IP20 or better.
• The total capacitance connected to Terminals + wrt – (i.e. the capacitance of the cable plus any
other capacitance) shall not exceed 83 nF.
• The enclosure is non-conducting and may generate an ignition-capable level of electrosatic charges
under certain extreme conditions. The user should ensure that the equipment is not installed in a
location where it may be subjected to external conditions that might cause a build-up of electrostatic
charges on non-conducting surfaces, additionally, cleaning of the equipment should be done only
with a damp cloth.
• The equipment shall only be supplied via Terminals + w.r.t. Terminals – from a barrier having a
maximum open circuit voltage Uo that is ≤28 V and a maximum short circuit current Io that is
≤93 mA, where Io is resistively limited. The barrier shall be ATEX certified by a notified body.
15.2 Conditions for IS-mB1 Beacon
• The equipment has an ingress protection rating of IP65. However, if it has been supplied without
cable entry devices, then the user shall ensure that the devices that are fitted will provide an ingress
protection that is appropriate to the environment in which it is installed i.e. IP20 or better. If only
one of the two cable entries are used, then the unused entry ‘knockout’ shall be left intact or fitted
with a blanking device that ensures ingress protection appropriate to the environment in which it is
installed i.e. IP20 or better.
• The enclosure is non-conducting and may generate an ignition-capable level of electrosatic charges
under certain extreme conditions. The user should ensure that the equipment is not installed in a
location where it may be subjected to external conditions that might cause a build-up of electrostatic
charges on non-conducting surfaces, additionally, cleaning of the equipment should be done only
with a damp cloth.
15.3 Conditions IS-mC1 Combined Sounder/Beacon
• The equipment has an ingress protection rating of IP65. However, if it has been supplied without
cable entry devices, then the user shall ensure that the devices that are fitted will provide an ingress
protection that is appropriate to the environment in which it is installed i.e. IP20 or better. If only
one of the two cable entries are used, then the unused entry ‘knockout’ shall be left intact or fitted
with a blanking device that ensures ingress protection appropriate to the environment in which it is
installed i.e. IP20 or better.
• The total capacitance connected to Sounder Terminals + wrt – (i.e. the capacitance of the cable plus
any other capacitance) shall not exceed 83 nF.
• The enclosure is non-conducting and may generate an ignition-capable level of electrosatic charges
under certain extreme conditions. The user should ensure that the equipment is not installed in a
location where it may be subjected to external conditions that might cause a build-up of electrostatic
charges on non-conducting surfaces, additionally, cleaning of the equipment should be done only
with a damp cloth.
This certificate and its schedules may only be CSA Group Netherlands B.V.
reproduced in its entirety and without change Utrechtseweg 310,
6812 AR, Arnhem Netherlands

DQD 544.09 Rev 2018-04-20 Page 5 of 7


SCHEDULE

EU-TYPE EXAMINATION CERTIFICATE Sira 05ATEX2084X


Issue 9

• The equipment shall only be supplied via Sounder Terminals + w.r.t. Sounder Terminals – from a
barrier having a maximum open circuit voltage Uo that is ≤28 V and a maximum short circuit current
Io that is ≤93 mA, where Io is resistively limited. The barrier shall be ATEX certified by a notified
body.
• If not already fitted, optional internal wiring connections between Sounder Terminals + / - and
Beacon Terminals + / - may be fitted by the user. The wiring used for such connections shall have a
minimum radial thickness of insulation of 0.5 mm.
15.4 Conditions for IS-mA2 Sounder
• The equipment has an ingress protection rating of IP65. However, as cable entry is via a ‘knockout’
in the bottom of the enclosure base, the user shall ensure that this enclosure base is sealed to
whatever it is attached by a method that provides ingress protection appropriate to the environment
in which it installed i.e. IP20 or better. An ‘O’ ring fitted within the outer rim of the bottom of the
enclosure base may be used for this purpose.
• The total capacitance connected to Terminals + w.r.t. – (i.e. the capacitance of the cable plus any
other capacitance) shall not exceed 83 nF.
• The enclosure is non-conducting and may generate an ignition-capable level of electrosatic charges
under certain extreme conditions. The user should ensure that the equipment is not installed in a
location where it may be subjected to external conditions that might cause a build-up of electrostatic
charges on non-conducting surfaces, additionally, cleaning of the equipment should be done only with
a damp cloth.
• The equipment shall only be supplied via Terminals + w.r.t. Terminals – from a barrier having a
maximum open circuit voltage Uo that is ≤28 V and a maximum short-circuit current Io that is
≤93 mA, where Io is resistively limited. The barrier shall be ATEX certified by a notified body.
15.5 Conditions for IS-mA3 Sounder
• The equipment has an ingress protection rating of IP65. However, as cable entry is via a ‘knockout’
in the bottom of the enclosure base, the user shall ensure that this enclosure base is sealed to
whatever it is attached by a method that provides ingress protection appropriate to the environment
in which it installed i.e. IP20 or better. An ‘O’ ring fitted within the outer rim of the bottom of the
enclosure base may be used for this purpose.
• The total capacitance connected to Terminals + w.r.t. Terminals S2 and S3 (i.e. the capacitance of
the cable plus any other capacitance) shall not exceed 83 nF.
• The enclosure is non-conducting and may generate an ignition-capable level of electrosatic charges
under certain extreme conditions. The user should ensure that the equipment is not installed in a
location where it may be subjected to external conditions that might cause a build-up of electrostatic
charges on non-conducting surfaces, additionally, cleaning of the equipment should be done only with
a damp cloth.
• The equipment shall only be supplied via Terminals + w.r.t. Terminals S2 and S3 from a barrier having
a maximum open circuit voltage Uo that is ≤28 V and a maximum short-circuit current Io that is ≤93
mA, where Io is resistively limited. The barrier shall be ATEX certified by a notified body.

This certificate and its schedules may only be CSA Group Netherlands B.V.
reproduced in its entirety and without change Utrechtseweg 310,
6812 AR, Arnhem Netherlands

DQD 544.09 Rev 2018-04-20 Page 6 of 7


SCHEDULE

EU-TYPE EXAMINATION CERTIFICATE Sira 05ATEX2084X


Issue 9

15.6 Conditions for IS-mA1M Sounder


• The equipment has an ingress protection rating of IP65. However, if it has been supplied without
cable entry devices, then the user shall ensure that the devices that are fitted will provide an ingress
protection that is appropriate to the environment in which it is installed i.e. IP20 or better. If only
one of the two cable entries are used, then the unused entry ‘knockout’ shall be left intact or fitted
with a blanking device that ensures ingress protection appropriate to the environment in which it is
installed i.e. IP20 or better.
• The total capacitance connected to Terminals + wrt – (i.e. the capacitance of the cable plus any
other capacitance) shall not exceed 83 nF.
• The enclosure is non-conducting and may generate an ignition-capable level of electrosatic charges
under certain extreme conditions. The user should ensure that the equipment is not installed in a
location where it may be subjected to external conditions that might cause a build-up of electrostatic
charges on non-conducting surfaces, additionally, cleaning of the equipment should be done only
with a damp cloth.
• The equipment shall only be supplied via Terminals + w.r.t. Terminals – from a barrier having a
maximum open circuit voltage Uo that is ≤28 V and a maximum short circuit current Io that is
≤93 mA, where Io is resistively limited. The barrier shall be ATEX certified by a notified body.
16 ESSENTIAL HEALTH AND SAFETY REQUIREMENTS OF ANNEX II (EHSRs)
The relevant EHSRs that are not addressed by the standards listed in this certificate have been identified
and individually assessed in the reports listed in Section 14.2.

This certificate and its schedules may only be CSA Group Netherlands B.V.
reproduced in its entirety and without change Utrechtseweg 310,
6812 AR, Arnhem Netherlands

DQD 544.09 Rev 2018-04-20 Page 7 of 7


Certificate Annexe

Certificate Number: Sira 05ATEX2084X


Equipment: IS-mA1 Sounder, IS-mB1 Beacon, IS-mC1 Combined Sounder/Beacon, IS-
mA2 Sounder, IS-mA3 Sounder and IS-mA1M Sounder
Applicant: European Safety System Limited

Issue 0 to 2 (The drawings listed with these Issues were rationalised and superseded by those detailed in Issue 3)
Issue 3
Drawing Sheets Rev. Date Title
CD 5011 1 of 1 A 09 May 05 Circuit Diagram - Sounder Board
CD 5012 1 of 1 A 09 May 05 Circuit Diagram - Beacon Board
D 5014 1 of 1 A 03 Jun 05 Certification Label - Sounder - ATEX
D 5015 1 of 1 C 21 Apr 06 Certification Label - Beacon - ATEX
D 5016 1 of 1 C 21 Apr 06 Certification Label - Combined Sounder / Beacon - ATEX
D 5017 1 of 1 A 01 Aug 05 General Assembly - Sounder
D 5018 1 of 1 A 03 Jun 05 General Assembly - Beacon
D 5019 1 of 1 A 01 Aug 05 General Assembly - Combined Sounder / Beacon
D 5021 1 of 1 A 24-Jun-05 PCB Assembly - Sounder
PL 5021 1 of 1 A 03 Jun 05 Parts List - Sounder PCB
D 5022 1 of 1 A 24 Jun 05 PCB Assembly - Beacon
PL 5022 1 of 1 A 03 Jun 05 Parts List – Beacon PCB
D 5032 1 of 1 A 29 Jun 06 Certification Label – Sounder – ATEX/IECEx/FM
D 5033 1 of 1 A 29 Jun 06 Certification Label – Beacon - ATEX/IECEx/FM
D 5034 1 of 1 A 29 Jun 06 Certification Label – Combined Sounder/Beacon - ATEX/IECEx/FM
Issue 4
Drawing Sheets Rev. Date Title
CD 5041 1 of 1 A 17-Oct-06 Circuit Diagram - IS-mA2 and IS-mA3 Sounders
D 5041 1 of 1 A 17-Oct-06 PCB Assembly - IS-mA2 and IS-mA3 Sounders
PL 5041 1 of 1 A 02 Aug 06 Parts List - IS-mA2 Sounder
D 5042 1 of 1 A 02 Aug 06 General Assembly - IS-mA2 and IS-mA3 Sounders
PL 5042 1 of 1 A 02 Aug 06 Parts List IS-mA3 Sounder
D 5043 1 of 1 A 02 Aug 06 Certification Labels - IS-mA2 Sounder
D 5044 1 of 1 A 02 Aug 06 Certification Labels - IS-mA3 Sounder
Issue 5
Drawing Sheets Rev. Date Title
CD 5011 1 of 1 A 09 May 05 Circuit Diagram - Sounder Board
D 5017 1 of 1 A 01 Aug 05 General Assembly - Sounder
D 5021 1 of 1 A 24 Jun 05 PCB Assembly - Sounder
PL 5021 1 of 1 A 03 Jun 05 Parts List - Sounder PCB
D 5051 1 of 1 A 12 Dec 06 Certification Label ATEX - IS-mA1M Sounder
Issue 6
Drawing Sheets Rev. Date (Sira stamp) Title
D 5032 1 of 1 B 11 Nov 09 IS-mA1 Sounder Label (ATEX, IECEx, FM)
D 5033 1 of 1 B 11 Nov 09 IS-mB1 Beacon Label (ATEX, IECEx, FM)
D 5034 1 of 1 B 11 Nov 09 IS-mC1 Combined Label (ATEX, IECEx, FM)
D 5043 1 of 1 B 11 Nov 09 IS-mA2 Sounder Label (ATEX, IECEx, FM)
This certificate and its schedules may only be CSA Group Netherlands B.V.
reproduced in its entirety and without change Utrechtseweg 310,
6812 AR, Arnhem,
Netherlands

DQD 544.09 Rev 2018-04-20 Page 1 of 2


Certificate Annexe

Certificate Number: Sira 05ATEX2084X


Equipment: IS-mA1 Sounder, IS-mB1 Beacon, IS-mC1 Combined Sounder/Beacon, IS-
mA2 Sounder, IS-mA3 Sounder and IS-mA1M Sounder
Applicant: European Safety System Limited

Drawing Sheets Rev. Date (Sira stamp) Title


D 5044 1 of 1 B 11 Nov 09 IS-mA3 Sounder Label (ATEX, IECEx, FM)
D 5051 1 of 1 B 11 Nov 09 IS-mA1M Sounder Label (ATEX, IECEx, FM)
Issue 7 - No new drawings were introduced.
Issue 8 - No new drawings were introduced.
Issue 9 - No new drawings were introduced.

This certificate and its schedules may only be CSA Group Netherlands B.V.
reproduced in its entirety and without change Utrechtseweg 310,
6812 AR, Arnhem,
Netherlands

DQD 544.09 Rev 2018-04-20 Page 2 of 2