Report # K-352144-1904F02-R00 Test Report

Kinectrics Inc., 800 Kipling Avenue, Unit 2


Samples Received: Samples Tested: Toronto, Ontario, Canada
Apr-05-19 Apr-10-19 Tel: 416-207-6000, www.kinectrics.com

Tested for Contact information for item tested:


ArcWear.com Paulson Manufacturing Corporation
3018 Eastpoint Parkway 46752 Rainbow Canyon Road
Louisville, KY 40223 Temecula, California 92592
ArcTesting@ArcWear.com
Test item description
Paulson Manufacturing Corporation, Faceshield, Style AMP1-20HT-EC,
Lens: Paulson Mfg Corp, Style HT Grey Premium Coated, Polycarbonate, Grey, Thickness 0.06",
Chin Protector: HT Grey,
Hard Hat: Mfg. Mine Safety, Style MSA V-Gard, Class E,
Bracket: Mfg. Paulson Mfg Corp, Style CB2-HD,
ArcWear# 1904F02

Reference Standard
ASTM F2178-17b
Standard Test Method for Determining the Arc Rating and Standard Specification for Eye or Face Protective Products

Test Parameters: Test current: 8 kA Number of samples analysed: 20


Arc Gap: 30 cm
Distance to Fabric: 30 cm Incident Energy Range: 14 to 30 cal/cm²

Arc Rating, ATPV = 26 Cal/cm²


Heat Attenuation Factor, HAF = 92%

No variations to standard method noted.


Samples tested as received, pre-test laundering as required by standard was arranged by client.

Test Summary
The Arc Rating of this material is intended for use as part of a flame resistant garment or system for workers exposed to electric arcs. The test
result is applicable only to the test item as described; other fiber blends, weaves, finishing or dye may have different protection level. The test
articles are tested as received; no test is done to validate the fiber content or composition. The Arc Rating was calculated based on the data
obtained and analysed in accordance with the latest version of the applicable standards. The individual test sheets, graphs, photographs of
the samples and video of every test are provided in digital format to the Client for review.

The arc testing performed to the above mentioned Standard is accredited by the Standards Council of Canada (SCC) to conform to the
requirements of CAN-P-4E (ISO/IEC 17025:2005). Accreditation by the Standards Council of Canada (SCC) is a mark of competence and
reliability recognized throughout the world.

Kinectrics Inc takes reasonable steps to ensure that all work performed shall meet the industry standards as set out in Kinectrics Inc.'s Quality
Manual, and that all reports shall be reasonably free of errors, inaccuracies or omissions. KINECTRICS INC. DOES NOT MAKE ANY
WARRANTY OR REPRESENTATION WHATSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO THE MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE OF ANY INFORMATION CONTAINED IN THIS REPORT OR THE RESPECTIVE WORKS OR SERVICES SUPPLIED OR
PERFORMED BY KINECTRICS INC. Kinectrics Inc. does not accept any liability for any damages, either directly, consequentially or otherwise
resulting from the use of this report.

Note: The test performed does not apply to electrical contact or electrical shock hazard.

©Kinectrics. Partial reproduction of this report is strictly prohibited without the express written consent of Kinectrics Inc.
Prepared by: Approved by:
Yosbani Guerra Andrew Haines
2019.05.02 2019.05.02
08:51:47 -04'00' 16:29:36 -04'00'
Yosbani Guerra Andrew Haines
HCL Technologist HCL Supervising Technologist
Kinectrics Inc. Kinectrics Inc.

Note: For verification about results in this report, please forward copy of the report or inquiry to hcl@kinectrics.com

Page 1 of 4
Date: Determination of ATPV by performing logistic regression on the panel
Apr-10-19 burn response as indicated in Summary Table
Report # Test Performed in accordance with: ASTM F2178-17b
K-352144-1904F02-R00

Fabric Description:
Paulson Manufacturing Corporation, Faceshield, Style AMP1-20HT-EC,
Lens: Paulson Mfg Corp, Style HT Grey Premium Coated, Polycarbonate, Grey, Thickness 0.06",
Chin Protector: HT Grey,
Hard Hat: Mfg. Mine Safety, Style MSA V-Gard, Class E,
Bracket: Mfg. Paulson Mfg Corp, Style CB2-HD,
ArcWear# 1904F02

Determination of ATPV
100 ATPV = 26 cal/cm²
Probability Ei
90
5% 21.0
80 10% 22.3
20% 23.6
70 30% 24.5
40% 25.2
60
50% 25.9
60% 26.5
50
70% 27.3
40 80% 28.1
90% 29.5
30 (Note: ATPV is reported to nearest integer
for ratings above 10 cal/cm²)
20
Total points analyzed = 20
10 Points above Stoll = 5
Points above mix zone = 3
Points below mix zone = 6
0 # Pts within 20% = 14
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 # Pts in mix zone = 11
Incident Energy (cal/cm²)

Determination of HAF
100
HAF = 92 %
95 Confidence Intervals
95% CI = 91.6 , 92.4
90

85

80

75
Data pts
70
Best Fit
65
95% CI
60
95% CI pts
55

50
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Incident Energy (cal/cm²)

Page 2 of 4
Date: Summary of Measured Energy and Observations
Apr-10-19
Test Performed in accordance with : ASTM F2178-17b
Report #
K-352144-1904F02-R00

Fabric Paulson Manufacturing Corporation, Faceshield, Style AMP1-20HT-EC,


Description: Lens: Paulson Mfg Corp, Style HT Grey Premium Coated, Polycarbonate, Grey, Thickness 0.06",
Chin Protector: HT Grey,
Hard Hat: Mfg. Mine Safety, Style MSA V-Gard, Class E,
Bracket: Mfg. Paulson Mfg Corp, Style CB2-HD,
ArcWear# 1904F02

Test # Panel Test Cycles Ei SCD HAF >Stoll Break Ablation After Omit Comment
Current of 60Hz Cal/cm² Cal/cm² % Y/N Open Y/N Flame Y/N
A Y/N sec.
1 K-352144-2176 A 8178 30.2 22.1 0.2 91.9 Yes - - 0 No Exceeded Stoll curve on Chin sensor.
2 K-352144-2176 B 8178 30.2 23.9 0.5 91.2 Yes - - 0 No Exceeded Stoll curve on Chin sensor.
3 K-352144-2177 A 8190 25.2 19.0 -0.1 91.2 No - - 0 No
4 K-352144-2177 B 8190 25.2 19.5 -0.2 91.2 No - - 0 No
5 K-352144-2178 A 8193 23.2 13.6 -0.1 88.2 No - - 0 No
6 K-352144-2178 B 8193 23.2 16.8 -0.1 91.1 No - - 0 No
7 K-352144-2179 A 8131 28.2 22.5 -0.4 93.7 No - - 0 No
8 K-352144-2179 B 8131 28.2 20.2 -0.3 93.5 No - - 0 No
9 K-352144-2180 A 8129 32.2 24.2 -0.2 93.5 No - - 0 No
10 K-352144-2180 B 8129 32.2 20.2 -0.2 91.7 No - - 0 No
11 K-352144-2181 A 8113 36.2 29.0 0.4 92.4 Yes - - 0 No Exceeded Stoll curve on Chin sensor.
12 K-352144-2181 B 8113 36.2 23.3 -0.3 92.5 No - - 0 No
13 K-352144-2182 A 8140 34.2 23.8 -0.3 93.1 No - - 0 No
14 K-352144-2182 B 8140 34.2 22.1 -0.4 93.0 No - - 0 No
15 K-352144-2183 A 8108 38.2 29.5 0.4 92.4 Yes - - 0 No Exceeded Stoll curve on Chin sensor.
16 K-352144-2183 B 8108 38.2 28.3 0.1 93.1 Yes - - 0 No Exceeded Stoll curve on Chin sensor.
17 K-352144-2184 A 8127 35.2 26.3 -0.2 93.6 No - - 0 No
18 K-352144-2184 B 8127 35.2 22.4 -0.2 91.9 No - - 0 No
19 K-352144-2185 A 8138 33.2 24.3 -0.1 92.4 No - - 0 No
20 K-352144-2185 B 8138 33.2 23.2 -0.4 92.7 No - - 0 No
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
There was no evidence of afterflame, breakopen, melting, dripping or ignition in any of the samples tested.