SUNSHINE 3D Aligner Calibration Process 2020-8-11

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 26

CALIBRATION PROCESS

Calibration process
CALIBRATION PROCESS

When will you make the calibration …


Reason1: Change the camera.
Reason2: Move the camera position.
Reason3: Most cars measurement with same
wrong phenomenon, like steering wheel
pulling to same side, big toe values or
camber values and so on .
CALIBRATION PROCESS

1. install the calibration system according to the


manual:
CALIBRATION PROCESS

2. open the software, choose the system settings.


CALIBRATION PROCESS
3. Click “Ctrl” + “Alt” in the keyboard.
CALIBRATION PROCESS
4. Open the F11 to check the camera view, keep the
calibration system in correct height.
CALIBRATION PROCESS
Steps:
Adjust the platform to the required position, and put the
calibration system on the left platform (same direction
with the car). Small target plate in the front close to
turntable, big target
plate in the back. Keep the two
targets clearly shown in the
camera view center.
CALIBRATION PROCESS
5. Click
"Continue", then it will show
NO.1.
CALIBRATION PROCESS
6. Click “Continue”, then it will show No.2.

Note: Inaccuracy Left:8 Right :24


Stand for the Calibration target conditions. For this number, smaller is better.
Usually the number is less than 30. If the number beyond 100, the calibration
will be stopped.
CALIBRATION PROCESS
7. move the bigger calibration target outward 5cm, then
click “Continue”.

5cm
CALIBRATION PROCESS
CALIBRATION PROCESS

8. Put the calibration system on the right side


platform, just the same as the left one. Then
click “Continue” to show from NO.3 to
NO.4. after that, move the rear bigger target
inside about 5cm. If it shows “error”,
please calibrate again, and make sure when
you move, keep slowly and lightly.
then click “Continue” .
CALIBRATION PROCESS
CALIBRATION PROCESS

5cm
CALIBRATION PROCESS
CALIBRATION PROCESS

9. put the calibration system across the left


and right of the platform, small target placed
in the front near to the turntable, big one
placed in the rear, keeping the bar 45
degree.

45°
CALIBRATION PROCESS
10. adjust the two targets position to be shown
clearly in the two camera view.
CALIBRATION PROCESS
11. Click “Continue” to No.6 step.
CALIBRATION PROCESS
12. Keep the bar with 45 °angle and move the two targets
together to rear direction 10cm.

10cm
CALIBRATION PROCESS

Then click “Continue to go to No.7 step.


CALIBRATION PROCESS
13. Repeat the No.12 step procedure, move the two
targets to rear side again, … Totally eight times.
CALIBRATION PROCESS
CALIBRATION PROCESS
CALIBRATION PROCESS
CALIBRATION PROCESS
13. After final 12 steps, it will show you “OK”. Click it, then
calibration finish.
CALIBRATION PROCESS

14. Restart the software and then it will be finished.

You might also like