CALCULATED RESULTS:
Individual nozzles: (SM-23 para 8.4.6.1) Limit = (500 / 3) . De . fn
EACH NOZZLE: Resultant Resultant FR + (MR/3) Allowable Load
Force Moment (English Units) (English Units)
N. Nm. De Allowable
Nozzle 1: 7874, 8775, 3927,3 10,000 5000, ....Passed
Nozzle 2: 1870,8 3741,7 1340,4 8,667 4333,3 ....Passed
Nozzle 3: 2692,6 3278,7 1411,3 9,333 4666,7 ....Passed
Nozzle 4: 1952,6 2193,7 978,2 8,000 4000, ....Passed
DIRECTIONAL RESULTANTS AT BALANCE POINT (NEMA SM-23 para 8.4.6.2): Allowable values referenced to the GLOBAL axis.
Resultant Forces Resultant Moments
Actual Allowable Actual Allowable
N. N. Nm. Nm.
X dir. Fx <= 50.Dc.fn.fc - 7500, 8996,1 ....Passed Mx <= 250.Dc.fn.mc 7875, 13712,5 ....Passed
Y dir. Fy <= 125.Dc.fn.fc 5750, 22490,2 ....Passed My <= 125.Dc.fn.mc - 4450, 6856,3 ....Passed
Z dir. Fz <= 100.Dc.fn.fc - 1500, 17992,1 ....Passed Mz <= 125.Dc.fn.mc 4625, 6856,3 ....Passed
fc = 4.448
mc = 1.356
Calculated 'equivalent circular opening' Dc = 13 in.