CW-1.2K Checkweigher and Sorting Machine UserManual
CW-1.2K Checkweigher and Sorting Machine UserManual
&
Sorting Machine
CW-1.2K
User’s manual
(Applicable for MCGS+C01 version)
GENERAL MEASURE
531701010033 Ver A2
Contents
1. Summary ............................................................................................ 1
1.1 Product Features ......................................................................... 1
1.2.1 Precautions........................................................................ 2
2. Product installation............................................................................... 3
Overall appearance ........................................................................ 3
3. Operation .................................................................................... 11
Operation summary ..................................................................... 11
Calibration................................................................................... 19
5. IO Module ......................................................................................... 27
5.1 TEST ........................................................................................ 27
7. Communication.................................................................................. 37
7.1 Communication parameters........................................................ 37
10.1.3 Precautions...................................................................... 62
1. Summary
CW-1.2K CheckWeigher is a high speed, high precision and small range industrial
automatic weighing scale developed by our company to meet the changing technological
update. For raw food, bags, bottles, containers and so on. Can be used for sorting 5 to 10
grades of weight.
The touch screen makes the CW-1.2K weighing scale easy to operate, external
expansion of IO input and output and external serial port communication to achieve multi-
point control, monitoring and remote control of the product.
1.1Product Features
Product parameters:
Accuracy of weight
Plus or minus 0.7 g
Checking
1
CW-1.2K user’s manual
2
CW-1.2K user’s manual
2. Product installation
Overall appearance
The product appearance is shown in Figure 2-1 below.
Serial
Name Introduction
number
3
CW-1.2K user’s manual
Mechanical installation
Place the weighing scale at the installation place and remove the sensor protection
device; Adjust the levelness of the weighing scale, and the inclination shall not exceed 0.5
degree; Fix the footing of the weighing scale, the stainless steel footing contacts the ground
smoothly, and lock the screws of the footing to ensure the stability of the weighing scale.
Adjust the distance between the check weighing platform and the front and rear end
conveying mechanism is 9 ~ 11mm, and the check weighing platform shall not be in contact
with other equipment. If the front and back end conveying mechanism is not equal to the
height, it is necessary to add the oblique conveying mechanism on one side, and add the
horizontal conveying mechanism connection on the side of the oblique mechanism (to leave
a gap) to check the weight scale platform, to ensure that the check weight scale platform
level and the height of the front and back end conveying mechanism.
The electric control box can be arbitrarily installed on the left and right sides of the
weighing scale to facilitate the operation of the production process.
Electrical installation
The power supply is inserted into the three-hole socket with ground or connected to the
power supply equipment such as the electric gas cabinet according to the line mark.
1. Any wiring and disconnecting operation can only be carried out after power off. After the
operation is completed, check before power on.
2. The serial port is fixed to RS485 communication, where the 485(A) pair should be
connected to 485(A) or 485(+), and the 485(B) pair should be connected to 485(B) or
485(-).
3. The IO module input point is valid at low level (DC0V) and does not allow access to
high voltage or alternating current.
4. IO module output point access relay coil for intermediate control, so the other end of the
relay can access DC or AC power supply IO module.
4
CW-1.2K user’s manual
Serial Function
number
5
CW-1.2K user’s manual
13 Reset key
Electrical interface
Photoelectric sensor (already wired at factory) :
E24V: photoelectric sensor DC24V+.
E0V: photoelectric sensor DC24V-.
E1: Signal input of photoelectric sensor for loading of weighing scale.
E2: Check the output photoelectric sensor signal input of the weight balance.
6
CW-1.2K user’s manual
DI3: clear the alarm. When the system generates an alarm, change the input to be
effective and the alarm will be cleared.
DI4: over rejection is completed. When the input is valid, the output of over rejection is
invalid.
DI5: under rejection is complete, under rejection output is invalid when this input is
valid.
DI6: continuous packet detection. This input signal is given by the photoelectric sensor
installed on the front conveyor line of the weighing scale and used in conjunction with the
busy stop output to control the start and stop of the front conveyor line of the weighing
scale. When there is an object being detected on the weighing platform and the signal is
effective, the busy stop output is effective.
DI0V: IO module power supply DC24V-.
DI24V: IO module power supply DC24V+.
4-way transistor output ports (functions can be customized, and can be
connected on site according to actual needs):
DO1: undefined.
DO2: undefined.
DO3: undefined.
DO4: undefined.
DO0V: IO module supply power DC24V-.
DO24V: IO module power supply DC24V+.
DOCOM: IO module common end.
Sensor (already connected at factory):
EX+ : Power positive, SN+ : induction positive,
EX- : power negative, SN- : induction negative,
SIG+ : signal positive, SIG- : signal negative.
Motor speed control communication interface (RS485) :
MT A: RS485 communication A.
MT B: RS485 Communications B.
MT G: RS485 Communication (GND).
7
CW-1.2K user’s manual
8
CW-1.2K user’s manual
Figure 2-4 shows the power supply and motor interface diagram, defined as follows:
External power supply (already connected at factory) :
L: External AC power live wire.
G: External AC power ground wire.
N: External AC power neutral wire.
Frequency converter output power supply (factory has been connected) :
U: Corresponding to the U terminal connected to the motor.
V: corresponding to the V terminal connected to the motor.
W: corresponding to the W terminal connected the motor.
9
CW-1.2K user’s manual
Note: L, N and G are the external AC power supply, and U, V and W are the output
power supply of the inverter to power the motor. These two groups of power supplies have
been connected before delivery. If the frequency converter or motor needs to be
reconnected in the subsequent use and maintenance process, please be sure to connect
correctly according to the instructions, and remember not to connect it backwards,
otherwise it will cause damage to the frequency converter.
10
CW-1.2K user’s manual
3. Operation
Operation summary
Pow on
Technician
login curr
New product ent
ch
oo
Set parameters
se
Limit removal
Before use, need to install the two limit shaft sleeves from the transportation position to
the working position. The position indicated by the arrow in Figure 3-2 is the installation
position of the limit shaft sleeve.
11
CW-1.2K user’s manual
Basic operation
The main interface is used for daily weight checking production, which is used to start
and stop the weight checking belt, enter the relevant parameter interface and display the
basic information of the tested product and the weight checking result.
Button and operation frame operation instructions (applicable to all operation interfaces of
the device) :
12
CW-1.2K user’s manual
1. Click this button to enter the interface of creating products and setting product
parameters.
3. Click this button to enter the data interface to view the relevant check data.
7. Click this type of action box to modify the value of this item.
10. Click this type of operation box to perform the corresponding operation.
11. Click this type of operation box to open and close the corresponding function
Settings.
13
CW-1.2K user’s manual
User login
At the touch screen initial interface, click "Product" or "Settings" to pop up the password
login box, select the user to enter the corresponding password and click "Confirm" to log in.
The initial passwords of the operator and administrator are written in the user description.
14
CW-1.2K user’s manual
★ The new product number cannot be added during the run state of checkweigher; The
newly added product parameter values are the default initial values of the system, which
need to be set according to the actual product parameters and production requirements.
15
CW-1.2K user’s manual
16
CW-1.2K user’s manual
Name Instructions
17
CW-1.2K user’s manual
Sampling start The sampling data from the time the object is on the scale to
percentage this percentage are discarded.
Sampling usage The continuous usage percentage data from the sampling start
percentage percentage is used to calculate the checkweighing result.
When the belt is running, within this setting value, the range of
Stable Time for weight variation is judged as the stability of the scale platform
Dynamic ZERO within the range of dynamic zero determination stability. Only
when the stability allows the dynamic zero
Sorting 1~10
Set the compensation coefficient for the corresponding partition
correction factor
to calculate the packaging weight of the product, the outer packaging weight of the
product can be written into the tare weight column, and the net weight should be filled in
the standard weight column.
The product number is automatically generated by the system; The linear speed of the
belt is calculated from the detection speed, and changes with the change of the
detection speed. It cannot be filled in (the linear speed of the belt should be consistent
with the linear speed of the front and rear end conveying mechanism).
The compensation weight difference value is calculated by dynamic calibration. Under
normal circumstances, manual change is prohibited to prevent deviation between the
product weight and the actual weight.
When filling in the product parameters, attention should be paid to its value range.
Generally, if it is lower than the lower limit of the parameter range, the parameter value
will remain unchanged; if it is higher than the upper limit of the parameter range, the
upper limit of the parameter range will be written by default.
The definitions of checkweighing speed, belt speed, and correction coefficient are
introduced in detail in the product parameter help interface. If necessary, click Help to
view it.
3.5.4 Delete product parameters
On the product list page, select the product to be deleted and click "Delete Product" to
delete the product. After deleting the product, subsequent product parameters will be
moved forward in sequence, and the product number will be moved forward. Products
cannot be deleted while the checkweigher is running and checking; in order to prevent
product parameters from being deleted by mistake, the product name should be set
appropriately when setting product parameters.
Calibration
In order to ensure the correct weight of the checkweigher and the linearity of the weight
change, each checkweigher requires weight calibration and dynamic calibration. For
specific operation methods, please refer to Chapter 3.3.2 "Operation Instructions for
Buttons and Operation Boxes".
19
CW-1.2K user’s manual
Name Instructions
Calibration empty Eliminate external interference and when the scale platform is
scale at zero status and stable, click.
Put the weight on and after entering the weight of the weight,
Weight calibration
click
Empty scale voltage The voltage value of the loadcell when the top of the scale is
value emptied
Weight voltage value The voltage value of the loadcell after placing the weight
21
CW-1.2K user’s manual
Name Instructions
Get the weight Stop the belt running and put the test material on, and the
static weight value will be displayed.
The belt will run. After the statically weighed object passes, it
should be moved back to the front platform. Repeated dynamic
operation, the controller will automatically record the dynamic
Start
weight. Generally, the dynamic calibration is performed ten
times, and the checkweigher will automatically stop when the
number of dynamic calibrations reaches the checkweigher.
Average weight During the dynamic calibration process, the average value of
each check-weighing result will be updated after the number of
dynamic calibrations is completed.
Correction factor The standard value is 1000. After the number of dynamic
calibrations is completed, the controller will automatically
calculate this value based on the dynamic results and static
weight.
If it is not convenient to perform dynamic calibration, you need
to input this value manually. It can be set in the product
parameter interface. Please refer to the method explained in
the dynamic calibration parameter help interface for the size of
the value.
When calibrating, you must ensure that the checkweigher is in a stopped state,
otherwise you cannot enter the dynamic calibration interface; when calibrating, you
should ensure that there are no objects on the scale, no vibration on the scale, and no
relatively strong air flow around the checkweigher.
When the scale is empty, ensure that the scale is at the zero position and stable.
Otherwise, please eliminate external interference and perform a "zero" operation.
When placing the product, avoid the product hitting the surface of the scale platform.
Only when the weight is stable can you click "Get Static Weight"; if the product has a
gross weight value, please set the gross weight value first and then perform dynamic
calibration.
The initial value of the number of learning times is 10 by default. If the accuracy of the
learning results is poor, the number of learning times can be appropriately increased; if
22
CW-1.2K user’s manual
the production requirements are not high in accuracy, the number of learning times can
be appropriately reduced to increase the learning speed; external interference should
be avoided during the learning process. After the learning is completed, the system will
automatically Save learning results and display.
The default value of learning times is 10. If the learning result is not accurate, you can
increase the learning times appropriately.If the production requirement is not high, the
learning times can be appropriately reduced to improve the learning speed;External
interference should be avoided in the learning process, and the system will
automatically save the learning results and display them after the completion of
learning.
Changes in product checking speed require dynamic recalibration.
The principle of dynamic calibration, attention to implementation and alternative
methods are introduced in detail in the dynamic calibration parameter help interface. If
necessary, click Help to view it.
23
CW-1.2K user’s manual
4. Data Viewing
This checkweigher has data storage and query functions, making it convenient for
users to check historical checkweighing data and event information. Under the main
interface of check-weighing, click "Data" to enter the data viewing interface (no permissions
are required for the data interface).
4.2Statistics
Click "Statistics" to enter the checkweighing data statistics interface, which intuitively
displays product distribution. Click "Print Data" to print the statistical information. Click
24
CW-1.2K user’s manual
"Export Data" to export the statistical information to a USB flash drive inserted into the
touch screen. Click "Delete Data" to clear statistics. For specific operation methods, please
refer to Chapter 3.3.2 "Operation Instructions for Buttons and Operation Boxes".
Statistical information includes over-tolerance, under-tolerance, cumulative inspection
times of qualified products, weight, average value, probability distribution, etc.
Before detecting a new batch of products, you need to clear the previous statistical
information, otherwise the new products will be accumulated on the original statistical
information and generate erroneous statistical information.
4.3Alarm information
Click "alarm record" to enter the interface for viewing alarm records, and you can view
the alarm information in the process of weight checking, including alarm serial number,
alarm time, number and alarm content. For specific operation methods, please refer to "
Button and operation box operation instructions" in Section 3.3.2.
25
CW-1.2K user’s manual
4.4Statistical graph
Click "Statistical Chart" to enter the statistical chart interface to visually view the
product weight distribution during product inspection.
26
CW-1.2K user’s manual
5. IO Module
5.1TEST
Click "I/O" on the setting page to enter the IO test interface. The system provides 6
input terminals and 12 output terminals. Users can decide whether to use them according to
27
CW-1.2K user’s manual
production needs. For specific operation methods, please refer to Chapter 3.3.2 "Operation
Instructions for Buttons and Operation Boxes".
The IO test is to test whether the IO port is connected to the external device normally.
During the test, click "Switch" behind the output to output 1-8. If the corresponding relay coil
is closed (the red indicator light on the relay base is on) and the corresponding device is
active, then the connection is normal and the output point of the checkweigher is valid.
Otherwise, please check whether the connection between the output point and the device is
correct; click "Switch" behind the three-color light. If all three-color indicator lights are on,
the wiring is correct.
The input test can be carried out by setting a low-level signal (DC0V) on the input
terminal. If the corresponding input port sets a low-level signal and it is valid, the test
indicator box behind the corresponding input point on the touch screen will light up and
display "ON" (can be used when testing photoelectric input). Block the photoelectric on the
main interface, and if the corresponding incoming and outgoing materials light up, the
photoelectric input is valid). Input and output signals can be defined by yourself.
The default IO is defined as follows:
DO 1 Undefined
28
CW-1.2K user’s manual
DO 2 Undefined
DO 3 Undefined
DO 4 Undefined
I01 Input When the input is valid, it means that the input
photoelectric photoelectric sensor has sensed the measured object
I02 Output When the input is valid, it means that the output
photoelectric photoelectric sensor has sensed the object under test
I03 Run When the input is valid, the device will start into the running
state
I04 Stop When the input is valid, the device will stop running
I05 Clear alarm When the input is valid, the device will clear the current
alarm
I06 Over reject When the input is valid, the over rejection have been
completed completed
I07 Under reject When the input is valid, the under rejection has been
completed completed
29
CW-1.2K user’s manual
I11 Run/stop [edge] When the equipment is in the stopped state and this signal
input is valid, the equipment starts to enter the running
state;
When the equipment is in running state and this signal
input is valid, the equipment stops running.;
I12 Stop (level) The signal is valid and the touch screen cannot start the
device
Output paras:
O01 Over-weight If the check-weighing result is over, the output is valid and
indication will continue until the next check-weighing is completed.
O02 Over-weight If the weight check result is under, the output is valid and
indication lasts until the next weight check is completed.
O06 Over reject If the check weight result is over, it will be delayed according
to the set distance of the over rejector, and then the output
will be valid according to the set duration.
O07 Under reject The weight check result is the under, it will be delayed
according to the set distance of the under rejector, and then
the output will be valid according to the set duration.
O08 Disqualified If the check weight result is over or under, it will be delayed
Reject according to the set distance of the unqualified rejector, and
then the output will be valid according to the set duration.
O09 Batches This output is valid when the set number of batches is
completed reached.
30
CW-1.2K user’s manual
O11 Busy Stop + When the system is in a busy state, the busy detection is
Communication valid, and the output is invalid. When the busy state is invalid
and a communication command is received, the output is
valid. When the busy detection is invalid, the output is valid.
O12 Busy stop When the system is in a busy state and busy detection is
valid, this output is invalid. When the busy state is invalid,
this output is valid. When busy detection is invalid, this
output is valid.
O19 Unpartitioned
O20 Sorting 1
O21 Sorting 2
O22 Sorting 3
O23 Sorting 4
O24 Sorting 5
O25 Sorting 6
O26 Sorting 7
O27 Sorting 8
O28 Sorting 9
O29 Sorting 10
31
CW-1.2K user’s manual
6. Working Parameters
6.1Working parameter Settings
Click "Settings" to enter the working parameter interface. The user can decide whether
to turn it on according to production needs. After turning it on, if a corresponding alarm
occurs, the checkweigher will automatically alarm or shut down. You need to manually click
"Clear Alarm" or input an external "Clear Alarm" signal. Then start the checkweighing again
(after the alarm is generated and until the alarm is cleared, the checkweigher motor runs
but does not perform the judgment operation of the object on or off the scale platform, nor
does it perform the weighing operation), and the alarm information is stored in "Data" -
"Alarm Information" middle. For specific operation methods, please refer to Chapter 3.3.2
"Operation Instructions for Buttons and Operation Boxes".
Name Instructions
Over and under queue The default number of over-under queues is 20, which means
that if the elimination distance is long enough, that is, it takes a
full alarm and
long time for the products to be eliminated to reach the
shutdown elimination mechanism, there can be more than 20 products in
the middle. If there are more than or equal to 20 products in
this distance, Products that exceed the deviation and need to
be eliminated will be alarmed and shut down.
32
CW-1.2K user’s manual
Failure to remove After the next unqualified product goes through the weighing
process and the previous product has not been removed, an
alarm in time and shut
alarm will be issued and the machine will shut down.
down
Busy alarm stop Before the previous product has flowed out of the check-
weighing belt, and the next product enters the check-weighing
belt, a busy alarm will be displayed and the machine will shut
down. If there is an over-to-under-tolerance rejection
mechanism connected to the back end, the default is over-to-
tolerance elimination.
Alarm and shutdown Indicates that if the discharging photoelectric sensor continues
to sense and exceeds the blocking time set on the system
when material blocking
parameter interface, an alarm will occur and the machine will
time is exceeded shut down.
Alarm and shutdown There are two situations here; 1. If the maximum time on the
weighing platform set on the touch screen is greater than twice
when exceeding the
the time required for the object to pass through the weighing
maximum time on the platform, the maximum alarm time on the weighing platform will
be twice the time required for the object to pass through the
weighing platform
weighing platform. 2. If the maximum time on the scale set on
the touch screen is less than or equal to twice the time required
for the object to pass through the scale, the maximum alarm
time on the scale will be the maximum time on the scale set on
the touch screen.
Exceed continuous In the product parameter setting interface, you can set the
number of consecutive failure alarms. If the set value is not
failure times alarm and
zero and the switch is turned on, when the number of
shutdown consecutive failures reaches this value, an alarm will occur and
the machine will shut down.
Motor load upper limit The maximum load that the motor can bear
33
CW-1.2K user’s manual
The motor stops when The upper limit of the motor load can be set on the system
parameter interface of the product. When the weight of the
the upper load limit is
product or the object to be weighed exceeds the set upper
exceeded limit, an alarm will be issued and the machine will shut down.
Over and under The main page displays that the result of the product being
tested is out of tolerance or under tolerance and the equipment
deviation alarm and
will be shut down. If you need to use this function, you need to
shutdown move the discharging photoelectric position forward. Please
contact our technical department for details.
The main page The main page displays whether the result of the product
tested is over, under or qualified.
displays over and
under information
The main page only Only the product inspection results of this inspection are
displayed on the main page.
displays the check
weight results when
running
Auxiliary display of Display the real-time weight of the detected product on the
main page
real-time weight
Calibration stability When calibrating the scale, if the weight change range is within
this setting value, the scale platform is judged to be stable.
range
Stable range During the stability judgment time, if the weight change range
is within this setting value, the scale platform is judged to be
stable.
Zero tracking range If the weight value is within this range, it will automatically zero.
Zero range The range of zeroing of the scale platform during weighing
34
CW-1.2K user’s manual
Calibration stability During calibration, if the weight change range is within the
stability range of the calibration scale within this time, the scale
time
platform is judged to be stable.
Stable time The range of weight variation is judged to be stable within the
value
Zero tracking time During this time, if the drift of the system data does not exceed
the zero tracking range, zero tracking will be performed.
Incoming debounce No sampling will be done within this time after incoming the
object.
time
Outgoing debounce No sampling will be done within this time before outgoing the
object.
time
Blocking time Starting from the time when the outgoing photoelectric sensor
detects the material, an alarm will be issued if this time is
exceeded.
35
CW-1.2K user’s manual
Dynamic zero range The range of zeroing of the scale platform during the check-
weighing process
Photoelectric dust When the system runs to the set value, the photoelectric dust
removal interval time removal begins
Over and under The over and under alarm is included in the alarm record
deviation alarms are
included in the alarm
record
36
CW-1.2K user’s manual
7. Communication
The product has RS485 and optional network port for external communication. The
communication protocol is standard Modbus RTU, and the network port communication
includes Modbus TCP/IP and HTTP protocol. When the communication mode is set as
print, RS485 can be connected to the printer to print. For detailed operation methods, refer
to "Button and operation box operation instructions" in section 3.3.2.
7.1Communication parameters
Click "Settings" to enter the working parameter interface, and then click the next page.
The user can set the relevant serial port communication method to realize communication
between the checkweigher and external control units such as the host computer or connect
to a printer.
37
CW-1.2K user’s manual
Name Instructions
38
CW-1.2K user’s manual
High and low High word first or low word first Facilitates
bytes communication with
various host
computers
When the host computer communicates with multiple checkweighers at the same time,
the equipment codes of each checkweigher cannot be consistent, and the maximum value
is 245 (a single host computer can support a maximum of 245 checkweighers connected to
it at the same time).
Serial Instructions
number
39
CW-1.2K user’s manual
HTTP working mode is server-side mode, and the protocol content is as follows:
⒈ Send: http://IP,
Return: current weigh value (screen display value).
For example:
Send to: http://192.168.61.223
Return: 123.456kg
⒉ Send:
http://IP/szgmt.html
Return: Current weighing value (screen display value).
For example:
Send: http://192.168.10.15/szgmt.html
Return: 123.456kg
⒊ Send:
http://IP/cwrf.html
Return: Current weigh value (screen display value), new weigh data identification.
For example:
Send: http://192.168.10.15/cwrf.html
Return: 123.456kg0 (This value changes from 0 to 1 or from 1 to 0 when there is a
new check result)
⒋ Send:
http://IP/crf.html
Return: New weigh data identification.
Example:
Send to: http://192.168.10.15/crf.html
Return: 1 (change the value from 0 to 1 or from 1 to 0 when there is a new check
result)
40
CW-1.2K user’s manual
... Reserve
.15 Reserve
.0 1: Run 0: Stop
.6. 1: Qualified
Module
40002 0001 current .7. 1: Busy (for indication)
status 2
.8. 1: IO test
.13 1: Keep
41
CW-1.2K user’s manual
... reserve
.1 Busy alarm
42
CW-1.2K user’s manual
.18 Reserved
43
CW-1.2K user’s manual
40521 0520
Maximum
40522 0521
40523 0522
Minimum
40524 0523
44
CW-1.2K user’s manual
40528 0527
45
CW-1.2K user’s manual
46
CW-1.2K user’s manual
42257 2256
Sample time Readable/writable,Unit: ms
42258 2257
42259 2258
Batch Readable.
42260 2259
42261 2260
Reject action time Readable/writable,Unit: ms
42262 2261
47
CW-1.2K user’s manual
42280 2279
42280 2280
…… …… Reserve
42300 2299
42317 2316
…… …… Reserve
42320 2319
48
CW-1.2K user’s manual
42337 2336
…… …… Reserve
42340 2339
42343 2342
Correction factor Initial value:0,
42344 2343
49
CW-1.2K user’s manual
Range:0~2000
42357 2356
…… …… Reserve
42360 2359
50
CW-1.2K user’s manual
42377 2376
…… …… Reserve
42380 2379
51
CW-1.2K user’s manual
Sorting
42390 2389
cumulative weight
42397 2396
…… …… Reserve
42400 2399
52
CW-1.2K user’s manual
42417 2416
…… …… Reserve
42420 2419
53
CW-1.2K user’s manual
Initial value:0,
42436 2435
Range:0~999999
42437 2436
…… …… Reserve
42440 2439
54
CW-1.2K user’s manual
42457 2456
…… …… Reserve
42460 2459
42477 2476
…… …… Reserve
42480 2479
55
CW-1.2K user’s manual
Sorting 10 upper
42482 2481
limit
The following is readable bit status (read function code 0x01, write
function code 0x05)
56
CW-1.2K user’s manual
7.3Print content
1. When the communication mode is set to print mode, the printer is connected, and
the print button is pressed on the "Statistics Data" interface, or a print command is sent
through the communication mode, the printout content is as follows:
----------------------- 上分隔横线符
DATE: 2015.10.15 打印日期
TIME: 15:21 打印时间
PRODUCT CODE: 1 产品号
TARE WT: 0.000kg 皮重值
UP LIM: 0.030kg 超差值
REF WT: 8.135kg 目标值
LOW LIM: 0.030kg 欠差值
PASS CT: 1 合格累计次数
PASS WT: 8.140kg 合格累计重量
PASS AVR: 8.140kg 合格平均重量
PASS RATE: 100.00% 合格率
OVER CT: 0 超差累计次数
OVER WT: 0.000kg 超差累计重量
UNDER CT: 0 欠差累计次数
UNDER WT: 0.000kg 欠差累计重量
TOTAL CT: 1 总累计次数
TOTAL WT: 8.140kg 总累计重量
MIN WT: 8.140kg 最小值
MAX WT: 8.140kg 最大值
----------------------- 上分隔横线符
57
CW-1.2K user’s manual
2. When the communication mode is set to result printing, the device will actively send
data. After each check, it will actively send the content shown in the following figure through
the serial port:
20140503142100 0.0346kg
The format is timestamp + weight. If there is an external printing device, the above
content will be printed. The above content is only an example. The specific printed data is
subject to the actual test results.
Among:
2. Status ——3 bit,If an alarm occurs, status 1 is "E" (45H), status 2, and status 3
are error identifiers, otherwise the three digits are spaces 20H.
3. sign —— 1 bit. Whenever there is a new sampling mean, the data label is
incremented by 1, from 30H to 39H, and then back to 31H. Used to assist in
extracting sampling data.
4. Limit —— 1 bit, the limit of the current sampling value. The upper limit of the
sampling value is "H" (48H). If the sampling value is qualified, it is "G" (47H). If the
lower limit of the sampling value is "L" (4CH).
5. Sampling results —— 7-digit weight data (including 6-digit content, 1 decimal point
(2EH), if there is no decimal point, the high digit is a space 20H).
6. If the weight value is 3.75, it is: 30H 30H 30H 33H 2EH 37H 35H
7. Unit - 2 digits, "kg (6BH 67H)" for kilogram and "g (67H 20H)" for gram.
8. CRC - is the checksum, that is, all the previous values are added and converted to
decimal, then the last two digits are taken and converted to ASCII code.
9. CR - return flag(0DH).
10. LF -- newline flag(0AH).
58
CW-1.2K user’s manual
8. Program Upgrade
The device can upgrade the mainboard program and HMI program through the way of
pen driver. For details, please refer to "Button and operation box operation instructions" in
section 3.3.2.
After contacting our technical department, confirm that the mainboard or HMI needs to
be upgraded before proceeding. First obtain the corresponding program upgrade package.
Insert the pen-driver containing the upgrade package, click the "U disk upgrade controller"
button to enter the upgrade interface, and follow the interface instructions to perform the
corresponding program upgrade. It is recommended to upgrade the equipment program
under the guidance of our technical support to avoid equipment failure or damage.
59
CW-1.2K user’s manual
9. Size
When the equipment is installed on site, it is necessary to ensure that there is no
contact between the weighing platform and the surroundings to avoid affecting normal
weighing. The distance around the weighing platform must be greater than 10mm.
60
CW-1.2K user’s manual
* Note: The width, length and height of the scale platform of non-standard customized
products may be different from the corresponding dimensions of standard products. For
details, please refer to the technical documents or drawings confirmed by the user.
61
CW-1.2K user’s manual
The ground shakes and vibrates, such as interference from nearby machines rotating,
cars passing by, etc.
Solution: Get rid of external interference
Conveyor belt affected by sticky objects
Solution: Get rid of external interference
There is debris accumulated or stuck on the sensor base.
Solution: Get rid of external interference
The filter coefficient is set too small
Solution: Increase the filter coefficient
10.2.3 Display is always zero
The object is light and its weight falls within the zero range.
Solution: Should be solved by resetting the "zero range"
The device is reset to zero.
Solution: This can be solved by adjusting the "Automatic Zero Tracking" item in the
system's calibration options.
The sensor data cable is loose and caused by poor contact.
Solution: Connect the sensor data cable
10.2.4 Data display abnormality
The error is too big.
Solution: Recalibrate.
Wrong product number selection.
Solution: The problem should be solved by clicking "Switch Product" again and
selecting the corresponding supporting product number..
The ambient temperature exceeds the normal operating range of the sensor.
Solution: Ensure that the ambient temperature is normal
The sensor components are aging or deformed.
Solution: Replace loadcell
10.2.5 Busy alarm
After the object is fed into the material, it does not come out of the weighing platform,
and another object is placed on the weighing platform.
Solution: Adjust the feeding speed, and only allow the next material to go on the scale
after the material leaves the scale..
63
CW-1.2K user’s manual
64