Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

5

4318

75
2000 2000
51 108108 108 108 51 150

193 80
SPLICE HOLE
(23*29)

546
850±20

193
SLOTTED HOLE

)
YP
(19*65)

(T
18
Ø
FGL

2000

2000
1150
ELEVATION CRF CHANNEL POST
(150*75*5, LG-2000)

NOTE:-
1. MATERIAL :
81±2 a. FOR T BEAM & SPACER - HOT ROLLED MS PLATE
CONFIRMS TO IS 2062:2011 / IS 5986:2017 / IS 10748:2004
FOR ISMC POST CONFIRMS TO IS 808
FOR FASTENERS CONFIRMS TO IS 1367, PART-13(HOT DIPPED GALVANIZED)
P)

2. MATERIAL PROTECTION :
a. HOT DIPPED GALVANIZED CONFIRMS TO IS 4759 : 1996 / IS 2629 : 1985
5
TY

HEX HEAD BOLT(M16) BUTTEN HEAD BOLT(M16)


75

3. DIMENSION TOLERANCE :
8(

SLOTTED HOLE THICKNESS TOLERANCE CONFIRMS TO IS 1852-1985

(19*65) 150 ( TO FIT SPACER WITH POST ) ( TO FIT BEAM WITH SPACER AND IN LINEAR & ANGULAR DIMENSION TOLERANCE CONFIRMS TO IS 2102 (PART - 1) GIVEN IN
Ø1

TABLE - 1 & 3 (TOLERANCE CLASS DESIGNATION - V)


SPLICE JOINT OF TWO ADJACENT BEAM ) 4. WEIGHT TOLLERANCE :
193 80

a. THE TOLERANCE ON WEIGHT OF INDIVIDUAL BUNDLES AND CONSIGNMENT FOR STRAIGHT


502+10

LENGTH UP TO AND INCLUDING 5 TONNES SHALL BE ±7 PERCENT OF THE THEORETICAL


-0

WEIGHT. THE THEORETICAL WEIGHT OF STRIP IS SPECIFIED IN IS : 1730 (PART-3) - 1974.


b. THE TOLERANCE ON WEIGHT OF INDIVIDUAL CONSIGNMENT ABOVE 5 TONNES SHALL BE ±5
PERCENT OF THE THEORETICAL WEIGHT.
546
3

80 193

(Arrjavv Square, 95A, Elliot Road, Kolkata - 700016)


** ALL DIMENSIONS ARE IN mm.
** UNLESS OTHERWISE SPECIFIED. DESCRIPTION: SINGLE SIDE SINGLE THRIE BEAM CRASH BARRIER

CRF CHANNEL SPACER CLIENT : -


THRIE BEAM SECTION (150*75*5, LG-546) DRAWING NO. -
UIL/23-24/ENQ/GA/SSSTBCB-3-5-2000-21-07-2023-546 PO. NO.
(502*81*3, LG-4318)
0 FOR FIRST SUBMISSION 21.07.2023 S.B DRAWN BY S.BHOWMIK DATE: 21.07.2023 PO DATE -
REV. REMARKS. DATE BY CHECKED BY DATE: - SCALE N.T.S