Technical Data Sheet - Air Blower For Aeration Tank

Project Name: Data Sheet No: HRL/22/WWTP/TDS/AB/07


0.88 MGD Sewage Treatment Plant
Smart City, Lahore

Revision: A
Project No. 22/3WS/HRL/WWTP/04/AMA-639/00 Dated: 17/04/2023

Location: Aeration Tank

Equipment Name: Rotary Lobe Air Blower

Manufacturer ROBUSCHI (Italy)


Series ES ( with sound enclosure)
Model ES 46/2 C

Quantity 3
Operating 2
Stand By 1

Service Conditions:
Medium Atmospheric Air
Maximum Air temperature 45 C
Minimum Air temperature 5 C
Altitude 233 m
Atmospheric Pressure 985.000 mbar
Relative Humidity 30~65 %
Installation Indoor

Specification:
Type Rotary Lobe Blower
Flow Rate (FAD) 621 m3/hr at 233 m and 45C
Differential Pressure 650 mbar
Blower Speed 3134 rpm
Performance tolerance ±5 %

Material:
Casing Cast Iron
Rotary lobe Cast Iron
Base frame MS painted

Drive:
Rated Power 18.5 kw
Power Supply 400V / 50 Hz / 3~
Starting VFD
Motor Speed 2925 rpm
Insulation Class F
IP 54

Accessories:
1-Acoustic Hood
2-Anti-vibrations mounts
3-One discharge rubber flexible connector
4-One wafer type check valve - single disk
5-One butterfly valve
6-Suction and discharge silencer
7- Pressure relief valve

Smart City Lahore Page 1 of 1 3W Systems (pvt) Limited