Professional Documents
Culture Documents
Avamar - How To Identify A Physical Gen4 - 4s Avamar Data Store Node Via The 'Chassis ID' Functionality On The Front Panel - Dell US
Avamar - How To Identify A Physical Gen4 - 4s Avamar Data Store Node Via The 'Chassis ID' Functionality On The Front Panel - Dell US
The "virtual" blue Chassis ID led should now be illuminated as in the screenshot below:
4. The virtual and physical Chassis ID LEDs will now be illuminated. To stop the illumination, have the CE physically depress the ID
LED (it doubles as a button) or run the below command:
ipmitool chassis identify 0
Example:
4. The LCD screen on the front of the node should now be flashing on and off (marked in red in the example below). To stop the
illumination, have the CE depress the grey button marked "i" next to the LCD, or run the following command:
racadm setled -l 0
Example:
Notes
Attachments
Article Properties