CB6024A Battery Charger

Battery Type selection Led Diag


Led Batt Fault Input: Single-phase 115 – 230 - 277 Vac
Fast Charge
Battery Connection Output Jumper Selectable: 24 Vcd 5A
Battery Fault Power Supply Function: (Optional)
Suited for the following battery types: Open Lead Acid, Sealed
Lead Acid, lead Gel, Ni-Cd (Option)
Battery Care: automatic diagnosis, battery status
Charging curve IUoU, constant voltage and current
Switching technology Fixed - Frequency
Charging type: Boost, Absorption, Float, Recovery.
Protected against short circuit, inverted polarity, over Load.
Signal output (Free Switch Contact): Fault battery state,
Main/BackUp
Protection degree IP20 - DIN rail – Wall Mount
Input: 110 – 277 Vac

Technical features
The CB series is a “Switching technology” and “Battery Care philosophy”, since years parts of Type of Signal Output Contact (free switch
the core know-how at ADEL system, led to the development of this advanced multi-stage
battery charging method, completely automatic and suited to meet the most advanced
contact)
requirements of battery manufacturers. The Battery Care concept is based on algorithms that Max. current can be switched (EN60947.4.1):
implement rapid and automatic charging, battery charge optimization during time, flat batteries Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A Resistive load
recovery and real time diagnostic during installation and operation. The Real Time Auto- Min.1mA at 5 Vdc Min. load
diagnostic system, monitoring battery faults such as, elements in short circuit, accidental
reverse polarity connection, disconnection of the battery, they can easily be detected and
General Data
removed by help of Blink Code of Diagnosis Led; during the installation and after sell. Each Insulation voltage (In / Out) 4000 Vac
device is suited for all battery types. It is possible setting predefined curves for Open Lead Protection Class (EN/IEC 60529) IP20
Acid, Sealed Lead Acid, Gel, Ni-Cd and. A rugged casing with bracket for DIN rail mounting Protection class II
and wall mount. Reliability: MTBF IEC 61709 > 300.000 h
Input Data Pollution Degree Environment 2
Nominal Input Voltage (2 x Vac) 115 – 230 – 277 Connection Terminal Blocks screw Type 2,5mm(24–14AWG)
Input Voltage range (Vac) 90 – 305 Housing material Polycarbonate
Inrush Current (Vn and In Load) I2t £ 16 A £ 5 msec. Dimensions (w-h-d) 72x90x61 mm
Frequency 47 – 63 Hz ± 6% Weight 0.30 Kg approx.
Input Current (115 – 270 Vac) 1.6 – 1.9 A Safety Standard Approval CE
Internal Fuse 4A Climatic Data
External Fuse (recommended) 10 A (MCB curve B) Ambient temperature (operation) -25 ÷ +70°C
Battery Charger Output De Rating Ta > 50°C - 2.5%(In) / °C
Fast Charge - Boost Charge 28.2 Vdc Ambient temperature Storage -40 ÷ +85°C
Fast Charge - Boost Charge Ni-Cd (option) 29 Vdc Humidity at 25 °C no condensation 95% to 25°C
Recovery Charge 2 – 20 Vdc Cooling Auto Convention
Charging Current Max Ibatt < 30°C (In) 5 A ± 5% Auto Derating Yes Up to 30 °C
Charging Current Max Ibatt > 30°C (In) 5 - 2.5 A ± 5% Norms and Certifications
Battery Tester Conforming to: IEC/EN 60335-2-29, EN60950/UL1236, Electrical safety,
Short circuit Element Detection Yes 89/336/EEC, EMC Directive, 2014/35/UE (Low Voltage), Emission: IEC 61000-
Battery Impendency (Life test) No 6-4, Immunity: IEC 61000-6-2.CE
Reverse polarity protection Yes Charging
Battery Disconnected (Protection No Spark) Yes Type of charging it is Voltages and current stabilized IUoU in conformity to
Battery Voltage Wrong Yes DIN41773. The state of charging battery and Auto-diagnosis of the systems are
identified by a blinking code on a Diagnosis LED and Battery Fault LED:
End of charge control Yes
State LED Green LED Yellow
Generic Output Data Diagnosis Battery Fault
Max. time Bust Charge (typ. At In) 16 h Recovery 5 Blink/sec OFF
Min. time Bust Charge (typ. At In) 2 min. Charging Boost – Bulk 2 Blink/sec OFF
Max.Time Bulk charge (Typ. at IN) 16 h Type Absorption 1 Blink/sec OFF
Min.Time Bulk charge (Typ. at IN) 2 min. Float 1 Blink/2 sec OFF
Float Charge: Depend on Battery type 2.23; 2,25; 2,3; 1.4 V Reverse polarity 1Blink
Float Charge Ni-Cd: V/cell (Jumper Config Battery
type) Auto Battery No connect 2Blink
End of charging current (Bulk & Absorption charge) 6% charging current Diagnosis Element in Short C. 3Blink
Charging current limiting Iadj 20 ÷ 100 % / In Replace Battery 5Blink
Quiescent Current ≤5mA
Remote Charge Input Control Boost / Float
Power Supply function Yes
Fast / Boost charge Enabling Terminal Blocks
Efficiency (50% of In) 87%
Dissipation Power load max (W) 9
Residual Ripple £ 60 mVpp
Quiescent Current £ 5 mA
Charging Curve automatic: IuoUo 4 stage
Detection of element in short circuit Yes
Short-circuit protection) Yes
Over Load protection Yes
Overheating Thermal Protection Yes
Over Voltage Output protection (Typ. 35Vdc)
Connection and Monitoring
Signal Output (free switch contact)
Main or Backup Input Power Yes
Low Battery Yes
Fault Battery Yes

All specifications are subject to change without notice