ANSI / FCI 70-3

Regulator Seat Leakage2

Leakage Class Maximum Seat Leakage


lo7bC1-ঞomo=-m‹Ѵ-vvķou(ˆ-Ѵˆ;‰_;u;7;vb]mbm|;m|bv|_;v-l;-v|_;
Ѵ-vv
basic class, but by agreement between user and supplier, not test is required.
Ѵ-vv 0.5% of rated valve capacity
Ѵ-vv 0.1% of rated valve capacity
Ѵ-vv( 0.01% of rated valve capacity
Ѵ-vv( Leakage per the following table as expressed in ml per minute versus seat diameter
Ѵ-vv( Leakage per the following table as expressed in ml per minute versus seat diameter
No observable bubbles for a period of one (1) minute using test methodology in Note
Ѵ-vv(
1 below

Nominal Seat Diameter


m1_;vŐbѴѴbl;|;uvő ml per minute Bubbles per minute
≤ 1 (25) 0.15 1
1.5 (38) 0.30 2
2 (51) 0.45 3
2.5 (64) 0.60 4
3 (76) 0.90 6
4 (102) 1.70 11
6 (152) 4.00 27
8 (203) 6.75 45
10 (250) 11.1 -
12 (300) 16.0 -
14 (350) 21.6 -
16 (400) 28.4 -

o|;Ɛŋ†00Ѵ;vr;ulbm†|;-v|-0†Ѵ-|;7-u;-v†]];v|;7-Ѵ|;um-ঞˆ;0-v;7om-v†b|-0Ѵ;1-Ѵb0u-|;7
measuring device in this case a 6 mm (0.24 inch) O.D. x 1 mm (0.04 inch) wall tube submerged in water
to a depth of from 3 to 6 mm (0.12 to 0.24 inch)

1
Ѵ†b7om|uoѴvmvঞ|†|;"|-m7-u7ķ"ņ ƕƏŊƑķom|uoѴ(-Ѵˆ;";-|;-h-];

 Ѵ†b7om|uoѴvmvঞ|†|;"|-m7-u7ķ"ņ ƕƏŊƒŊƑƏƐѵķ!;]†Ѵ-|ou";-|;-h-];
2

JORDAN 13 13