FIQ Should this VFD be

4121 controlled by tank level with


HS
an LIC?
4121A
FIT HS
4121 4121B
SW: Sensor Vibration
ST: Sensor Temperature
Include vibration and temperature sensor in motor
TAH
TI
4122
TIT
FIQ
4122
4122
SW
FIT ST
4122
How is this split and
controlled? Are there
supposed to be valves before
the centrifuges or 2 separate
outlets from the tank with
dart valves?
Centrifuge feed often
controlled on torque, but here
it looks like they will have to
take all of the incoming feed AE
from the tank. 4135
HS
4135A
HS
4135B
WIT WIQ
4135 4135 ®