Heat transmission coefficient for an offshore SinglePipe

Doc. No.: 7411-10010-THP-00A-001-00 Date: 04-04-2017


Project: Balongan bends Technical calculation - End of life properties with Temp: 85 °C, WD: 30 m
Project ID: 7411-10010 SinglePipe 85 SW

Dimensions [mm] [in] Material data


Diameter of steel pipe 812,0 31,97 Thermal conductivity inner liner PE 0,450 [W/(m K)]
Wall thickness steel pipe 20,32 0,800 Thermal conductivity, inner pipe (steel) 45,0 [W/(m K)]
Wall thickness inner liner PE 0 0,000 Thermal conductivity, anti corosion coating 0,450 [W/(m K)]
Thickness of AC coating: 3LPE 3,50 0,138 Thermal conductivity, insulation (PUR) initial 0,027 [W/(m K)]
Diameter of HDPE casing 1000 39,37 Thermal conductivity, HDPE casing 0,450 [W/(m K)]
Thickness of HDPE casing 20,0 0,79 Thermal conductivity, Field Joint, Hyperlast SPU 0,195 [W/(m K)]
Insulation layer, initial 70,5 2,78 Density, insulation (PUR) initial 80 [kg/m3] 0,2
Insulation layer, End of life 60,6 2,39 Creep PU foam by volume 15,00 %
R_inner liner PE [mK/W] 0,00000 Creep PU foam by thickness 14,04 %
R_inner pipe [mK/W] 0,00018 Creep total coating thickness 10,53 %
R_anti corrosion coating [mK/W] 0,00304 Density, insulation (PUR) EOL 94 [kg/m3]
R_insulation [mK/W] 0,75703 Thermal conductivity, Insulation (PUR) EOL 0,029 [W/(m K)]
R_casing [mK/W] 0,01474
Density of liquid (Sea Water) 1015 [kg/m3]
R_field joint [mK/W] 0,16297
R_water [mK/W] 0,00081 Control measures:
D : external diameter, EOL 0,9802 [m]
Heat Transfer Coefficient Pipe Joint U [W/(m K)] 1,2890 D_i : internal diameter, casing pipe EOL 0,9402 [m]
[W/(m² K)] 0,5053 d : external diameter, inner pipe 0,8120 [m]
d_i : internal diameter, inner pipe 0,7714 [m]
Heat Transfer Coefficient Hyperlast Field Joint U [W/(m K)] 5,988 d_a : external diameter, anti corrosion coating 0,8190 [m]
[W/(m² K)] 2,347 D_c: external diameter of coating system 1,0000 [m]
Coating system OD 1,0000 [m]
Note:
Length media pipe m 12,20 Assumption: Heat transfer coefficient, water 400 [W/(m² K)] mm
Insulation cutback (mid slope) mm 415,00 Assumption: U-value based on inner steel pipe (OD/ID): OD 812
Insulated pipe length m 11,37

Buoyancy
End of life: Wall thickness of concrete coating 0 mm
OHTC including Field Joint U [W/(m² K)] 0,63 Safety factor, empty pipeline 0,62
Calculation tool version 1,9 [W/(m K)] 1,609 Safety factor, full liquefied pipeline (Sea Water) 1,21

Calculation methods in accordance with ASTM C680 and ISO 12241 Print date 04-04-2017