SAAKSHI MACHINE & TOOLS PVT LTD Title:- Design Output Verification HF 400 L Doe, No.:Doc. No.: SMTPLIDVIHF 400/01 Rev. No.: 00 Date: 01.07,2022 Scope:- This Document is created to Verify Design Parameters of HF 400. Content: ‘A. Dimensional Inspection Parameters B. General Inspection Parameters C. Functional Check Parameters D. Operational Check Parameters Inspected by :- Mr. Satyaprakash Tiwari Date of Inspection:- 01.07.2022 Instruments Used Instrument Name Instrument ID Cal Date Cal Due Date Raysafe Solo RIF a neeaae SM-QA-17 28-06-2022 28-06-2023 Measurement Tape |S-FAB-22 10.01.2022 410.01.2023-—_ TER. A. HF 400 X-Ray System Output (HF Generator and X-ray Tube integration) ([wAsTER co} SN | DESCRIPTION Hecepiance eiteria Raul x Verified by HF Generator | ~ 1 | Output Power 32kW specification label and by doing Exposure i ’a E ye mattasare Metallic powder coated Enclosure Visually Verified 3_| Operating Keypad/panel | Membrane type _ Visually Verified Verified by HF Generator 1 Phase, 220/240V AC +10% , specification label and by 4 | Input Supply 50/6012 doing Expure after giving 1 Phase, 220-240V AC +10% , _ 50Hz suppl Verified, through control 5 | kV Range 40 to 125 kV console panel of machine by increasing and decreasing kV —— ____| parameter and by doing 1|Page a Doc. F/D&D/08 Prepared by Mir. SatyaprakastyT : proved by: Mr. Shailesh Scanned with CamScanner Increment/Decrement inkv | 10, 12.5, 16, 20, | 80, 100, 125, 160 ma 25, 32, 40, 50, 63 MA stations, } | increasing and decreasing Exposure from 40 kV to 125 __ {kv Verified, through ‘ontrol console panel of machine by increasing and decreasing kV | b earameten es Verified, through control Console panel of machine by increasing and decreasing mA parameter and by doing ‘posure between 10 to 400 Verified, through control console panel of machine by mA parameter and through Small focus Indication in the control console. Verified, through control console panel of machine by Large Focus 200, 250, 320 ,400mA ma casing and decreasing i MA parameter and through | Large focus Indication in the Fe control console ea] Verified, through control | console panel of machine by 10 | Time Range 0.004s6¢ ~ 10sec increasing and decreasing I} Timer Range and by | | Exposing between the jf) Ranges. eee 9.004, 0.005. 0.006, 0.008, 0.010, | 9.013, 0.016, 0.020. 0.025. 0.032. Hey 0080, 0050, 0063, e060, 0.100. | Verited, through control 12 200, 0.250, 0.320, 11 | step 125, 0.160, 0.200, 0250, 0.320, 0.400. 0.500, 0.630, 0.800, 1.00, 1.25, 1.60, 2.00, 250, 320, 4.00, 5.00. 6.3, 8.0, 10see console panel of machine by increasing and decreasing ‘Timer station, console panel of machine by ‘ImAS ~ 630mAs, increasing and decreasing mAs parameter, 113, Verified, through control Step S16, 2.0, 2.5, 32, 40, 50, 3. 80. 10.0, 12.5, 16, 20, 25, 32, 40. 50. 63, 80. 100, 125, 160, 200 > 250, 320, 400, 500, 630mAs Verified, through control console panel of machine by increasing and decreasing mAs parameter, 2[Page Prepared by Mr SatyaprakaanT Verified by doing kV output v “SK : % Measurement, Verified in ce Lab IEC60601-2.54 mA Accuracy £10% mA Verified by doing mA Doc. F/D&D/08 PDTOV If Shailesh K amScanner kv ee _ iii E ee Verified, through control console panel of machine by increasing and decreasing kV 6 | Increment/Decrement kV inky Ue X _{ parameter, = Verified, through control console panel of machine by 7 | MA Range 10 to 400 ma increasing and decreasing ™A parameter and by doing Exposure between 10 to 400 = fe MA station i aaa | Verificd, through control console panel of machine by a :, 10, 12.5, 16, 20, 25, 32, 40, 50, 63, increasing and decreasing | mA Range Small Focus 80, 100, 125, 160 ma nA parameter and through Small focus Indication in the | control console. | Verified, through control | fonsole panel of machine by Large Focus 200, 250, 320,400mA increasing and decreasing LA Parameter and through Large focus Indication in the — 2 ee control console Verified, through control Console panel ~ sec. i Time Range increasing and ‘imer Range a a ee | 11 | step ~Apprageac’: FD&Dyns "Scanned with CamScanner [Display os 7 | Operating Tempe 17 | Range | Storage Temperate {18 | Range rature Display: | HOC to « 40% —|Visuatly Verified feedback measurement Manual -20°Ct0 + 70% Manual [49 "[ Ret nidity Range | 30% + + Range | 30% to 95761 ed in tab 20 | Line Impedane ess than Verified through Line entire __[testinozsa—*[ eee Allthe components shallbe 21 | Groundin Brovied th grounding (alow. | i] ae | 29 mm2:Green copper eable should | Verified —— |e used fe Z| 22 | Protection [verified — SRILA. spine pais. upper Ty yonnc ae 23 | Radiography for Tanparcheowerexteemitis, | Uovnlly Verified through different body parts | lungor chest soft eave wnt ag neice ee aes Product should be EMC Compliant ee ee Vesityintab | 28 | compatibiity requirements, Propare:(Refer installation Manual) ones Planned Maintenance Program. | Verified & Avalable in IFU : 2. User routine checks program | Manual 3.Cleaning & Disinfection Program Warning fequired atall critical areas Refer | 26 | labels/indication iia ee Sreas Refer | verified Visually z [-572.6mmt2mm x WAG2Smm_ | Verod Measurement ee eee Senn ar eraepn ae vein” iS 1-400mm<2mm x H-47-3mm [Verified Ty ~-Mcasunea 28 | Dimension of Console 22mm *W-198mm2im | veifcation 3)_Supply Cable : collimator SN __ tables PYCcable 2¢ Red and Black) Asqamm. Grey | Canneaiviy Wnts by doing = 63 pin MX-191 connection between HF Generator 3991549 fork Lg 1 Ssqmmx3, and Collimator & working of collimator Cables Connectivity 61327 CABLE 0.75SQMM x 6 CORE Grey (Core color 5 iv black and 1 in Yel Connectivity Verified by doing 3\Pa ‘Prepared by Mr; Sulyaprakash-T connection betwee Doc. F/D&D/08 ATO by Me Shailesh K——— Scanned with CamScanner osu iarnnaaaricable 61327 CABLE 0.75SQMM X 6 CORE Grey (Core color : 5 in black | Verified by doing connection & | [and Tube Rotor & Working of) | Ih L9915AY fork, Lug LSsqnm x 3.77002 | PVC sleeve 3mm Rotor Connectivity = | Cable(4 Core) mm. Grey (Core color : red, yellow, blue ce em iy ar or HW. yoy ingconeton 4) interconnecting Cable : 30 KVA static balancer to generator: sw | Cables i a 1 = Wire 10 5q min-RED RR ~ 2 Wire 10 5q mm-Black RR 2 era sven om tarraTaaog |. ete dong cannon & a PVC Conduit (Pipe) 32mm (103895) Gray . __and Lin Yel /Grn.)_ Working of Bucky 4 [Page Prepared by Mr. SatyaprakashT : == ratty ese vei bY: Mi. Shailesl KC Scanned with CamScanner \

You might also like